Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High vacuum measurements and calibrations, molecular flow fluid transient effects

High vacuum pressure measurements and calibrations below 1 × 10 -8 Torr are problematic. Specifically, measurement accuracies change drastically for vacuum gauges when pressures are suddenly lowered in vacuum systems. How can gauges perform like this? A brief system description is first required to answer this question. Calibrations were performed using a vacuum calibration chamber with attached vacuum gauges. To control chamber pressures, vacuum pumps decreased the chamber pressure while nitrogen tanks increased the chamber pressure. By balancing these opposing pressures, equilibrium in the chamber was maintained at selected set point pressures to perform calibrations. When pressures were suddenly decreased during set point adjustments, a sudden rush of gas from the chamber also caused a surge of gas from the gauges to decrease the pressures in those gauges. Gauge pressures did not return to equilibrium as fast as chamber pressures due to the sparse distribution of gas molecules in the system. This disparity in the rate of pressure changes caused the pressures in different gauges to be different than expected. This discovery was experimentally proven to show that different gauge designs return to equilibrium at different rates, and that gauge accuracies vary for different gauge designs due to fluid transients in molecular flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward an international practical pressure scale: A proposal for an IPPS ruby gauge (IPPS-Ruby2020)

At the 26 th AIRAPT conference in 2017, a task group was formed to work on an International Practical Pressure Scale (IPPS). This report summarizes the activities of the task group toward an IPPS ruby gauge. We have selected three different approaches to establishing the relation between pressure ( P ) and ruby R1-line shift ( Δλ ) with three groups of optimal reference materials for applying these approaches. Using a polynomial form of the second order, the recommended ruby gauge (referred as Ruby2020) is expressed by: P [ G P a ] = 1.87 ( ± 0.01 ) × 10 3 Δ λ λ 0 1 + 5.63 ( ± 0.03 ) Δ λ λ 0 , where λ 0 is the wavelength of the R1-line near 694.25 nm at ambient condition. In June of 2020, the Executive Committee of AIRAPT endorsed the proposed Ruby2020. Finally, we encourage high-pressure practitioners to utilize Ruby2020 within its applicable pressure range (up to 150 GPa), so that pressure data can be directly compared across laboratories and amended consistently as better scales emerge in the future.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Power, Wide Dynamic Range Carbon Nanotube Vacuum Gauges

This slide presentation presents carbon nanotube vacuum pressure sensor gauges that operate at low power and exhibit a wide-dynamic range based on microelectromechanical systems (MEMS) technology. The fabrication facility, and the formation process are shown. Pressure sensitivity was found to increase rapidly as the bias power was increased. In addition, by etching part of the thermal SiO2 beneath the tubes and minimizing heat conduction through the substrate, pressure sensitivity was extended toward lower pressures. Results are compared to a conventional thin film meander resistor, which was fabricated and whose pressure response was also measured for comparative purposes.

JEOL E-beam aligner↗

Cryogenic Technology Development for Exploration Missions

This paper reports the status and findings of different cryogenic technology research projects in support of the President s Vision for Space Exploration. The exploration systems architecture study is reviewed for cryogenic fluid management needs. It is shown that the exploration architecture is reliant on the cryogenic propellants of liquid hydrogen, liquid oxygen and liquid methane. Needs identified include: the key technologies of liquid acquisition devices, passive thermal and pressure control, low gravity mass gauging, prototype pressure vessel demonstration, active thermal control; as well as feed system testing, and Cryogenic Fluid Management integrated system demonstration. Then five NASA technology projects are reviewed to show how these needs are being addressed by technology research. Projects reviewed include: In-Space Cryogenic Propellant Depot; Experimentation for the Maturation of Deep Space Cryogenic Refueling Technology; Cryogenic Propellant Operations Demonstrator; Zero Boil-Off Technology Experiment; and Propulsion and Cryogenic Advanced Development. Advances are found in the areas of liquid acquisition of liquid oxygen, mass gauging of liquid oxygen via radio frequency techniques, computational modeling of thermal and pressure control, broad area cooling thermal control strategies, flight experiments for resolving low gravity issues of cryogenic fluid management. Promising results are also seen for Joule-Thomson pressure control devices in liquid oxygen and liquid methane and liquid acquisition of methane, although these findings are still preliminary.

Chato, David J.↗

Analysis of Completion Design Impact on Cluster Efficiency and Pressure-Based Well Communication in HFTS-2 Delaware Basin

The Hydraulic Fracturing Test Site 2 (HFTS-2) is a joint industry project in the Delaware basin to advance hydraulic fracturing understanding and improve productivity in shale reservoirs. The project integrates multi-disciplinary approaches to evaluate different completion designs, well spacing, inter-well communication, and stimulated rock volume, among other factors. This paper focused on two major areas related to hydraulic fracture performance. First, an analysis of different completion designs on cluster efficiency based on near well Distributed Acoustic Sensing (DAS). Second, an evaluation of well and completion designs on inter-well fracture driven interactions (FDIs) based on downhole pressure monitoring. Fluid/sand distribution and cluster efficiency analyses were based on near wellbore DAS data collected from two adjacent horizontal wells completed in two different landing zones in the Wolfcamp formation. These wells had different completion designs aiming to evaluate the effect of normal vs. extended stage lengths, perforation hole tapering and limited entry. Standard deviation from ideal fluid/sand distribution and waterfall plots were used to evaluate cluster efficiency for each design and stage. Inter-well FDIs analysis was conducted among the horizontal wells and a vertical monitor well. One horizontal well served as the monitor well while the other horizontal well was being treated. The vertical well was instrumented with downhole pressure and temperature gauges to aid monitoring fracture height growth. The pressure response during and after fracturing was characterized based on maximum pressure increase value and slope. Pressure response vs. FDIs trigger factors such distance, cluster efficiency and stage fluid volume were also analyzed. Based on the different completion and perforation designs tested, DAS analysis suggests that limited entry design worked best. Extreme limited entry showed the potential of high perforation erosion and reduced cluster efficiency. Here, the limited entry and tapered perforation design demonstrated potential to improve the cluster efficiency for extended stage lengths. Pressure monitoring across formation units proved to be critical to understand fracture interactions and fracture vertical growth. Pressure communication across different formation units during hydraulic fracturing operation indicate fractures grew upwards during Wolfcamp wells fracturing. However, this pressure communication dissipated over time. High intensity FDIs were recorded when the frac stages Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/1-21URTC/D011S018R001/2477607/urtec-2021-5289-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5289 were closer to the pressure gauge location in the monitor wells. Some of these stages that produced high intensity FDIs also had high fluid volume per cluster and low cluster efficiency. The multi-disciplinary and high-quality data collected from HFTS-2 helped to further understand why completion approaches such as limited entry and tapered perforation design are successful in improving cluster efficiency. The DAS data combined with downhole high-resolution pressure measurements also helped to quantify the effect of lower cluster efficiency data on the incidence and intensity of FDIs.

58 GEOSCIENCES↗

Pressure effect on the sensitivity of quartz Bourdon tube gauges.

The sensitivity change for a commercial fused quartz Bourdon tube precision pressure gauge, due to a change in absolute pressure level, has been analytically computed and experimentally confirmed. The computed differential pressure error is 2.5% of full scale at a 100 atm absolute pressure level. The experimental method compared the fused quartz Bourdon tube gauge digital output to the results obtained from a nitrogen gas pressure system which had a high pressure, well-type mercury manometer as the differential pressure reference.

Szaniszlo, A. J.↗

Hydraulic Fracturing Test Site (HFTS) – Project Overview and Summary of Results

The Hydraulic Fracture Test Site (HFTS) is a field-based hydraulic fracturing research experiment performed in the West Texas Permian (Midland) Basin. The HFTS includes $25 million of hydraulic fracturing research that is centralized around eleven horizontal wells fractured with over 400 stages in the Upper and Middle Wolfcamp formations as well as two recompleted legacy wells. As part of the HFTS experiment, and in addition to the comprehensive field data that was collected, approximately 600 feet of excellent quality, whole core was obtained by drilling a high-angle core well through the induced hydraulic fractures at the test site. Based upon observations of the acquired core, the understanding of hydraulic fracture propagation and effectiveness of proppant placement is challenging current thinking. Well interference testing and in-situ reservoir pressure measurements using bottom hole gauges in producing wells and discrete multilevel pressure gauges in an offset monitor well aid in understating fracture connectivity and conductivity over time.

Ciezobka, Jordan↗

Pressure Testing of a Minimum Gauge PRSEUS Panel

Advanced aircraft configurations that have been developed to increase fuel efficiency require advanced, novel structural concepts capable of handling the unique load conditions that arise. One such concept is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) developed by the Boeing Company. The PRSEUS concept is being investigated by NASA s Environmentally Responsible Aviation (ERA) Program for use in a hybrid-wing body (HWB) aircraft. This paper summarizes the analysis and test of a PRSEUS panel subjected to internal pressure, the first such pressure test for this structural concept. The pressure panel used minimum gauge skin, with stringer and frame configurations consistent with previous PRSEUS tests. Analysis indicated that for the minimum gauge skin panel, the stringer locations exhibit fairly linear response, but the skin bays between the stringers exhibit nonlinear response. Excellent agreement was seen between nonlinear analysis and test results in the critical portion at the center of the panel. The pristine panel was capable of withstanding the required 18.4 psi pressure load condition without exhibiting any damage. The impacted panel was capable of withstanding a pressure load in excess of 28 psi before initial failure occurred at the center stringer, and the panel was capable of sustaining increased pressure load after the initial failure. This successful PRSEUS panel pressure panel test was a critical step in the building block approach for enabling the use of this advanced structural concept on future aircraft, such as the HWB.

Lovejoy, Andrew J.↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gauge calibration by diffusion

Vacuum gage calibration by diffusing a known quantity of gas through a heated barrier into a gauge is examined. The gas flow raises the pressure in the gauge to known level and is then compared with the gauge's pressure reading.

Brock, F. J.↗

Portable self-contained pressure testing manifold and associated methods

A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.

Milholland, Roger A.↗