Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PREAMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Magnetic quench antenna for MQXF quadrupoles

High-field MQXF-series quadrupoles are presently under development by LARP and CERN for the upcoming LHC luminosity upgrade. Quench training and protection studies on MQXF prototypes require a capability to accurately localize quenches and measure their propagation velocity in the magnet coils. The voltage tap technique commonly used for such purposes is not a convenient option for the 4.2-m-long MQXF-A prototype, nor can it be implemented in the production model. We have developed and tested a modular inductive magnetic antenna for quench localization. The base element of our quench antenna is a round-shaped printed circuit board containing two orthogonal pairs of flat coils integrated with low-noise preamplifiers. The elements are aligned axially and spaced equidistantly in 8-element sections using a supporting rod structure. The sections are installed in the warm bore of the magnet, and can be stacked together to adapt for the magnet length. We discuss the design, operational characteristics and preliminary qualification of the antenna. Lastly, axial quench localization capability with an accuracy of better than 2 cm has been validated during training test campaign of the MQXF-S1 quadrupole.

43 PARTICLE ACCELERATORS↗

Characterization of Amplification Properties of the Superconducting-Ferromagnetic Transistor

Here we report on the measurement results of the superconducting-ferromagnetic transistors (SFTs). The devices were made at Northwestern University and Hypres (SeeQC), Inc. (Nevirkovets et al., 2014; 2015). SFT is a multiterminal device with the SIS'FIFS (or SFIFS'IS) structure (where S, I, and F denote a superconductor, an insulator, and a ferromagnetic material, respectively) exploiting intense quasiparticle injection in order to modify the nonlinear I-V curve of a superconducting tunnel junction. SFT is capable of providing voltage, current, and power amplification while having good input/output isolation. We characterized the devices using different measurement techniques. We measured S parameters of the single- and double-acceptor devices at frequencies up to 5 MHz. Importantly, we confirmed that the isolation between the input and output of the device is quite good. However, the techniques typically employed to characterize semiconductor devices do not allow for revealing the full potential of our low-resistive SFT devices, especially those having two acceptors. In the latter case, we also tested the devices using the battery-powered current sources with floating grounds. Analyzing double-acceptor I-V curves recorded at different levels of injection currents, for an optimal load, we deduced a small-signal voltage gain of 33 and a power gain of 2.4. We suggest that further improvement of the SFT device parameters is possible in optimized devices, so that the device potentially may serve as a preamplifier for readout of output signals of cryogenic detectors and be useful as an element of other superconductor-based circuits. In addition, we used scanning transmission electron microscopy to identify some problems in the fabrication of the devices without any planarization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensor Authentication: Embedded Processor Code

Described is the c code running on the embedded Microchip 32bit PIC32MX575F256H located on the INL developed noise analysis circuit board. The code performs the following functions: -Controls the noise analysis circuit board preamplifier voltage gains of 1, 10, 100, 000 -Initializes the analog to digital conversion hardware, input channel selection, Fast Fourier Transform (FFT) function, USB communications interface, and internal memory allocations -Initiates high resolution 4096 point 200 kHz data acquisition -Computes complex 2048 point FFT and FFT magnitude. -Services Host command set -Transfers raw data to Host -Transfers FFT result to host -Communication error checking

Svoboda, John↗

Optical parametric amplification of spectrally incoherent pulses

The optical parametric amplification of spectrally incoherent signals is analyzed and simulated using a set of normalized equations describing phase-matched three-wave nonlinear mixing. Varying the amplifier’s properties and the seeding conditions reveals different amplification regimes. In particular, the relative temporal walk-off of the signal, idler, and pump has a strong impact on the temporal and spectral properties of the amplified signal. The amplification efficiency for spectrally incoherent signals is not significantly lower than that of a coherent monochromatic signal, provided that the phase-matching bandwidth is sufficient. Here, the results obtained with the normalized set of equations are in good agreement with simulations based on the full description of the crystals’ dispersion for high-gain LBO and BBO preamplifiers and a low-gain DKDP power amplifier.

47 OTHER INSTRUMENTATION↗

Design and Implementation of an Underwater Sound Recording Device

The purpose of this study was to design and build two versions of an underwater sound recording device. The device designed is referred to as the Underwater Sound Recorder (USR), which can be connected to one or two hydrophones or other underwater sound sensors. The URS contains a 26 dB preamplifier and a user selectable gain that permits additional amplification of input to the system from 26 dB to 46 dB. Signals within the frequency range up to 15 kHz may be recorded using the USR. Examples of USR applications are monitoring underwater processes that have the potential to create large pressure waves that could potentially harm fish or other aquatic life, such as underwater explosions or pile driving. Additional applications are recording sound generated by vessels or the vocalizations of some marine mammals, such as the calls from many species of whales.

47 OTHER INSTRUMENTATION↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. Among the different cryogenic detector types, Magnetic Micro-Calorimeters (MMCs) have the potential of faster count rates and better linearity. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. MMC gamma detectors measure the energy of absorbed gamma rays form the resulting change in magnetization of an erbium-doped gold (Au:Er) sensor. The signal is read out with a SQUID preamplifier and processed digitally with room temperature electronics (see inset figure 2). The objective of this project is to develop ultra-high energy resolution γ-detectors based on magnetic micro-calorimeters (MMCs) for accurate non-destructive isotope analysis (NDA). Since MMCs, like other cryogenic γ-detector technologies with operating temperatures <0.1 K, are intrinsically slow and have to be small for high resolution, special emphasis will be placed on questions that determine sensitivity and the potential for scaling to arrays. Objectives for FY14 were therefore to fabricate an improved version of MMC γ-detectors and test their energy resolution, maximum count rate, readout noise, crosstalk between pixels and linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗

Fabrication of Gamma Detectors Based on Magnetic Ag:Er Microcalorimeters

This report discusses the photolithographic fabrication of ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs). The MMC uses a novel Er-doped silver sensor (Ag:Er) that is expected to have higher sensitivity than the Er-doped gold (Au:Er) sensors currently in use. The MMC also integrates the first-stage SQUID preamplifier on the same chip as the MMC gamma detector to increase its signal-to-noise ratio. In addition, the MMC uses a passive Ta-Nb heat switch to replace one of the common long-term failure points in earlier detectors. This report discusses the fabrication process we have developed to implement the proposed improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Dry Dilution Refrigerator for MMC Gamma Detector Arrays

The goal of this LCP is to develop an ultra-high resolution gamma detector based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material to replace current Au:Er sensors. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers. MMC detectors require operating temperatures of ~15 mK and thus the use of a dilution refrigerator, and the desire for user-friendly operation without cryogenic liquids requires that this refrigerator use pulse-tube pre-cooling to ~4 K. For long-term reliability, we intend to re-design the heat switch that is needed to apply the magnetizing current to the Ag:Er sensor and that used to fail in earlier designs after months of operation. A cryogenic Compton veto will be installed to reduce the spectral background of the MMC, especially at low energies where ultra-high energy resolution is most important. The goals for FY16 were 1) to purchase a liquid-cryogen-free dilution refrigerator and adapt it for MMC operation, and 2) to fabricate Ag:Er-based MMC γ-detectors with improved performance and optimize their response. This report discusses the design of the instruments, and progress in MMC detector fabrication. Details of the MMC fabrication have been discussed in an April 2016 report to DOE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-Low Noise Germanium Neutrino Detection system (ULGeN).

Monitoring nuclear power plant operation by measuring the antineutrino flux has become an active research field for safeguards and non-proliferation. We describe various efforts to demonstrate the feasibility of reactor monitoring based on the detection of the Coherent Neutrino Nucleus Scattering (CNNS) process with High Purity Germanium (HPGe) technology. CNNS detection for reactor antineutrino energies requires lowering the electronic noise in low-capacitance kg-scale HPGe detectors below 100 eV as well as stringent reduction in other particle backgrounds. Existing state- of-the-art detectors are limited to an electronic noise of 95 eV-FWHM. In this work, we employed an ultra-low capacitance point-contact detector with a commercial integrated circuit preamplifier- on-a-chip in an ultra-low vibration mechanically cooled cryostat to achieve an electronic noise of 39 eV-FWHM at 43 K. We also present the results of a background measurement campaign at the Spallation Neutron Source to select the area with sufficient low background to allow a successful first-time measurement of the CNNS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiscal Year (FY) 2017 Activities for the Spent Fuel Nondestructive Assay Project

The main focus of research in the NA-241 spent fuel nondestructive assay (NDA) project in FY17 has been completing the fabrication and testing of two prototype instruments for upcoming spent fuel measurements at the Clab interim storage facility in Sweden. One is a passive instrument: Differential Die-away Self Interrogation-Passive Neutron Albedo Reactivity (DDSI), and one is an active instrument: Differential Die-Away-Californium Interrogation with Prompt Neutron (DDA). DDSI was fabricated and tested with fresh fuel at Los Alamos National Laboratory in FY15 and FY16, then shipped to Sweden at the beginning of FY17. Research was performed in FY17 to simplify results from the data acquisition system, which is complex because signals from 56 different 3He detectors must be processed using list mode data. The DDA instrument was fabricated at the end of FY16. New high count rate electronics better suited for a spent fuel environment (i.e., KM-200 preamplifiers) were built specifically for this instrument in FY17, and new Tygon tubing to house electrical cables was purchased and installed. Fresh fuel tests using the DDA instrument with numerous configurations of fuel rods containing depleted uranium (DU), low enriched uranium (LEU), and LEU with burnable poisons (Gd) were successfully performed and compared to simulations.1 Additionally, members of the spent fuel NDA project team travelled to Sweden for a “spent fuel characterization and decay heat” workshop involving simulations of spent fuel and analysis of uncertainties in decay heat calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma detectors based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material, and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. Since best MMC performance requires detector operation at ~10 mK, we will purchase a dilution refrigerator with a base temperature <10 mK and adapt it for MMC operation. The detector performance will be tested with radioactive sources of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Requirements for the Implementation of a Fused Silica Debris Shield

The National Ignition Facility (NIF) is the world’s largest and most energetic laser. It consists of 192 individual laser beams that, when first fired from the master oscillator room, are no more energetic than a typical laser pointer. After the initial firing, the lasers are sent through a preamplifier where the energy is increased by a factor of 10 billion. The laser light is amplified even further in the NIF laser bays by “stretching”each individual laser to a cross sectional area of approximately one square foot and passing them through the NIF power amplifiers, then multiple times through the NIF main amplifiers inside the NIF Laser bays. The laser beams make one final pass through the through the power amplifiers before they are reflected out of the laser bays.

42 ENGINEERING↗

MagMicro with Ultra-High Energy Resolution (Progress Report Q4 FY18)

We are performing extensive simulations of the MMC detector response to optimize their energy resolution, detection efficiency and count rate based on the data we took in FY17/18. The optimized layout separates the MMC detector chip from the SQUID preamplifier chips coupled to the MMCs through Al wire bonds to avoid heating the MMC with the power dissipation of the SQUID. The goal is to design MMC gamma detectors with a limiting energy resolution below ~25 eV FWHM up to >100 keV and ~1 ms decay times for maximum count rates of several tens of counts/s per pixel. The simulations, which were done at the Supercomputing Center of the University of New Mexico, are taking significantly longer than expected. The difficulty is that the device performance depends intricately on the design parameters, and each simulation is quite involved because it needs to cover the frequency range well into the GHz range to account for the ac Josephson effect. This is delaying the start of the detector array fabrication, and we have not been able to complete the fabrication and the testing of the 32-pixel MMC arrays by September 30. We have therefore requested a no-cost extension of the project to March 31, 2019.

42 ENGINEERING↗

MagMicro with Ultra-High Energy Resolution (FY19 Q3 Progress Report)

The fabrication of the MMC detector arrays involves two photolithographic procedures. The first is to fabricate the Nb magnetization coil and pick-up coils, the SQUID preamplifiers and the associated wiring. This is done on a full 4” Si wafer, which is subsequently diced into ~0.5 cm2 SQUID chips and ~1 cm2 detector chips. The detector chips are then processed separately by depositing and patterning the paramagnetic Ag:Er sensor and support structures and then electroplating the Au absorber. In Q3, we have successfully completed the full wafer processing for the 32-pixel MMC detector arrays, diced the 4” wafer into the smaller chips and tested the individual components. The coils have the required critical current, the heat switches have a critical temperature in the desired range, and the SQUIDs have the required low noise. Unfortunately, the sputter deposition of the paramagnetic Ag:Er sensor failed several times. We spent considerable time to trace the problem to contaminations of the purifier for the Ar sputtering gas that had been exposed to atmosphere for an extended time during an earlier clean room upgrade. We then determined that the purifier is not essential for high-quality Ag:Er sensor films (Fig. 1), and successfully deposited the Ag:Er sensor film on the ~1 cm 2 detector chip.

42 ENGINEERING↗

X-Ray Monitor for SuperKEKB HER/LER to Monitor Vertical Beam Size Bunch-by-Bunch

The beginning of the period of performance for this grant began after we had designed a Printed Circuit Board (PCB) for biasing and transporting signals from a new, thin Silicon strip sensor made at the Stanford Nanofabrication facility. This complex PCB was manufactured in mid-2017, and then work began on a preamplifier design that would take signals from the sensor and provide sufficient gain while maintaining fidelity, in terms of noise figure and signal speed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗