A Novel Multi-Agent Deep Reinforcement Learning-enabled Distributed Power Allocation Scheme for mmWave Cellular Networks

We consider the power allocation problem over shared spectrum for millimeter-Wave (mmWave) cellular downlink. Existing approaches usually find sub-optimal solutions by solving a non-convex optimization which leads to scalability issues due to centralized control. Therefore, distributed and adaptive approaches are desirable. Recently, model-free Deep Reinforcement Learning (DRL) has achieved success in such wireless resource management tasks. By modeling the radio environment as a Markov Decision Process (MDP) with the base stations (BSs) being the agents, power allocation can be automated at the agent level with comparable throughput performance to conventional centralized schemes. The multi-agent setting presents new challenges as the radio environment is impacted by the joint actions of the agents and is no longer stationary from any individual agent’s perspective. Existing literature bypasses this non-stationarity violation by ignoring it which may cause performance degradation. To tackle this issue, we propose a distributed continuous power allocation scheme based on a modified version of multi-agent Deep Deterministic Policy Gradient (MADDPG) that is tailored for the distributed multiple-agent setting. The proposed scheme employs a centralized-training distributed-execution framework where Q-functions are trained over subsets of BSs while each BS determines its transmit power based only on its own local observation. It admits constant per-BS communication and computation complexity and is thus scalable to large networks. Numerical evaluation shows that the proposed scheme adapts well to a wide range of interference conditions and can achieve comparable or better performance than several state-of-the-art non-learning approaches.

99 GENERAL AND MISCELLANEOUS↗

Space power distribution system technology. Volume 1: Reference EPS design

The multihundred kilowatt electrical power aspects of a mannable space platform in low Earth orbit is analyzed from a cost and technology viewpoint. At the projected orbital altitudes, Shuttle launch and servicing are technically and economically viable. Power generation is specified as photovoltaic consistent with projected planning. The cost models and trades are based upon a zero interest rate (the government taxes concurrently as required), constant dollars (1980), and costs derived in the first half of 1980. Space platform utilization of up to 30 years is evaluated to fully understand the impact of resupply and replacement as satellite missions are extended. Such lifetimes are potentially realizable with Shuttle servicing capability and are economically desirable.

Decker, D. K.↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

Photovoltaic Power System and Power Distribution Demonstration for the Desert RATS Program

A stand alone, mobile photovoltaic power system along with a cable deployment system was designed and constructed to take part in the Desert Research And Technology Studies (RATS) lunar surface human interaction evaluation program at Cinder Lake, Arizona. The power system consisted of a photovoltaic array/battery system. It is capable of providing 1 kW of electrical power. The system outputs were 48 V DC, 110 V AC, and 220 V AC. A cable reel with 200 m of power cable was used to provide power from the trailer to a remote location. The cable reel was installed on a small trailer. The reel was powered to provide low to no tension deployment of the cable. The cable was connected to the 220 V AC output of the power system trailer. The power was then converted back to 110 V AC on the cable deployment trailer for use at the remote site. The Scout lunar rover demonstration vehicle was used to tow the cable trailer and deploy the power cable. This deployment was performed under a number of operational scenarios, manned operation, remote operation and tele-robotically. Once deployed, the cable was used to provide power, from the power system trailer, to run various operational tasks at the remote location.

Colozza, Anthony↗

Survey and Benchmark of Benefits of High Voltage SiC Applications in Medium Voltage Power Distribution Grids

The main objective of this survey and benchmark study is to identify and document potential high-impact applications in today's and future medium voltage (MV) distribution grids that will significantly benefit from high voltage (HV) (i.e. > 3.3 kV) SiC-based power electronics equipment. In particular, it is desirable to identify applications that can utilize the high switching speed and high control bandwidth enabled by SiC-based equipment. Specifically, the benefits of using SiC are quantified through the benchmark analysis and design using simulation for the selected high-impact applications. In addition, to provide grid support services, it is necessary to consider grid requirements in the grid-connected converter's design. Therefore, the impact of grid requirements on the HV SiC-based grid-connected converter is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Layered Coordination Architecture for Resilient Restoration of Power Distribution Systems

The current practices for restoring critical services in the distribution system during a disaster, align with the traditional centralized ideology of distribution systems operations. A central processor evaluates the distribution system after a disruption and attains a restoration plan. However, the centralized operational paradigm is susceptible to single-point failures, requires full situational awareness of the distribution system, and poses scalability challenges for large multifeeder distribution systems. This motivates a distributed decision-making paradigm where multiple agents solve smaller subproblems and jointly coordinate their individual decisions to achieve the global/network-level objective. Toward this goal, we propose a layered architecture for distributed algorithms for resilience and a two-stage distributed algorithm for distribution system restoration. The proposed distributed decision-making framework enables the bottom-up restoration of the distribution system using all available resources, including distributed generation, while only requiring local awareness and limited communications with neighboring connected regions. The proposed framework is robust to single-point failures, enables autonomy using distributed algorithms, and had reduced computational cost compared to centralized optimization solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Signal-Based Fast Tripping Protection Schemes for Electric Power Distribution System Resilience

This report is a summary of a 3-year LDRD project that developed novel methods to detect faults in the electric power grid dramatically faster than today’s protection systems. Accurately detecting and quickly removing electrical faults is imperative for power system resilience and national security to minimize impacts to defense critical infrastructure. The new protection schemes will improve grid stability during disturbances and allow additional integration of renewable energy technologies with low inertia and low fault currents. Signal-based fast tripping schemes were developed that use the physics of the grid and do not rely on communication to reduce cyber risks for safely removing faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Synthetic U.S. Electric Power Distribution System Data Sets

There is a strong need for synthetic yet realistic distribution system test data sets that are as diverse, large, and complex to solve as real systems. Such data sets can facilitate the development of advanced algorithms and the assessment of emerging distributed energy resources while avoiding the need to acquire proprietary critical infrastructure or private data. Such synthetic data sets, however, are useful only if they are realistic enough to look and behave similarly to actual systems. This paper presents a comprehensive framework for validating synthetic distribution data sets using a three-pronged statistical, operational, and expert validation approach. Furthermore, it also presents a set of statistical and operational metric targets for achieving realistic data sets based on detailed characterization of more than 10,000 real U.S. utility feeders. The paper demonstrates the use of the proposed validation approach to validate three large-scale synthetic data sets developed by the authors representing Santa Fe, New Mexico; Greensboro, North Carolina; and the San Francisco Bay Area, California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High frequency power distribution system

The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

Patel, Mikund R.↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Advanced Propulsion Power Distribution System for Next Generation Electric/Hybrid Vehicle: Preliminary System Studies - Phase 1

The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.

Bose, Bimal K.↗

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.