Effects of an unbalanced magnetron in a unique dual-cathode, high rate reactive sputtering system

Simple plasma and magnetic field measurements are presented to illustrate the opportunities afforded by using unbalanced magnetrons in a dual-cathode system. The system employs a pair of opposed cathodes, 38 cm x 13 cm, placed 27.5 cm apart, to coat specimens mounted on a rotational substrate holder. Comparisons are drawn between the original 'balanced' magnetron and several unbalanced configurations in terms of field strengths, deposition rates, etching characteristics, and substrate ion current densities for the growth of TiN films. The effects of 'unbalancing' on the nature of the plasma within the 3D geometry of the deposition chamber are elucidated via plasma probe and magnetic field studies performed under a variety of conditions. All the unbalanced configurations examined provided enhanced ion bombardment at the surface of the growing film. The closed-field or opposed magnet geometry resulted in a threefold or greater increase in current density when compared with that obtained using the corresponding mirrored geometry under the same conditions.

Rohde, S. L.↗

On Ba(+) production in the CRIT 2 experiment

Analysis of partical data from the CRIT 2 experiment, studying Alfven's critical ionization velocity (CIV) effect, shows that the density of newly created ions (presumably Ba(+) from the shaped-charge beam) is consistent with the increase in total plasma density measured by the independent RF plasma probe on board (Swenson et al., 1990) at the most active time period. We model this ion production using the measured electron flux data and the neutral barium model of Stenbaek-Nielsen et al. (1990a). To identify the main source mechanisms which may contribute most to the barium ionization, a simple model for the barium ion density at the payload location is developed based on Liouvilles theorem. We estimate that the electron impact ionization is responsible for 90% of the barium ion production observed by CRIT 2 in the first release and up to 45% in the second release. By employing a two-state approximation calculation (Rapp and Francis, 1962), the Ba-O(+) charge exchange cross section is found to range from about 2.0 X 10(exp -17) sq cm at a velocity of 4 km/s to 2.0 X 10(exp -15) sq cm at a velocity of 20 km/s. This result suggests that the Ba-O(+) charge exchange is probably dominant among all the non-CIV ionization processes. By considering the charge exchange process in our density model, the barrium ion densities are calculated for the two releases on CRIT II. The comparison between the model results and the observed data is found to be resonably consistent if the cross sections, as calculated above, are multiplied by 0.3 for the first release and 1.0 for the second release. Our result suggests that the charge exchange process could be the most important non-CIV ionization mechanism in the CRIT II experiment and it should be considered carefully case by case in CIV experiments.

Liou, K.↗

Validation of ISS Floating Potential Measurement Unit Electron Densities and Temperatures

Validation of the Floating Potential Measurement Unit (FPMU) electron density and temperature measurements is an important step in the process of evaluating International Space Station spacecraft charging issues .including vehicle arcing and hazards to crew during extravehicular activities. The highest potentials observed on Space Station are due to the combined VxB effects on a large spacecraft and the collection of ionospheric electron and ion currents by the 160 V US solar array modules. Ionospheric electron environments are needed for input to the ISS spacecraft charging models used to predict the severity and frequency of occurrence of ISS charging hazards. Validation of these charging models requires comparing their predictions with measured FPMU values. Of course, the FPMU measurements themselves must also be validated independently for use in manned flight safety work. This presentation compares electron density and temperatures derived from the FPMU Langmuir probes and Plasma Impedance Probe against the independent density and temperature measurements from ultraviolet imagers, ground based incoherent scatter radar, and ionosonde sites.

Coffey, Victoria N.↗

Investigation of a Gallium MPD Thruster with an Ablating Cathode

Arc impedance, exhaust velocity, and plasma probe measurements are presented. The thruster is driven by a 50 microsecond pulse from a 6.2 milliohm pulse forming network, and gallium is supplied to the discharge by evaporation of the cathode. The arc voltage is found to vary linearly with the discharge current with an arc impedance of 6.5 milliohms. Electrostatic probes yield an exhaust velocity that is invariant with the discharge current and has a peak value of 20 kilometers per second, which is in reasonable agreement with the value (16 plus or minus 1 kilometer per second) calculated from the mass bit and discharge current data. Triple probe measurements yield on axis electron temperatures in the range of 0.8-3.8 eV, electron densities in the range of 1.6 x 10(exp 21) to 2.1 x 10(exp 22) per cubic meter, and a divergence half angle of 16 degrees. Measurements within the interelectrode region yield a peak magnetic field of 0.8 T, and the observed radial trends are consistent with an azimuthally symmetric current distribution. A cathode power balance model is coupled with an ablative heat conduction model predicting mass bit values that are within 20% of the experimental values.

Thomas, Robert E.↗

Electric Field Double Probe Measurements for Ionospheric Space Plasma Experiments

Double probes represent a well-proven technique for gathering high quality DC and AC electric field measurements in a variety of space plasma regimes including the magnetosphere, ionosphere, and mesosphere. Such experiments have been successfully flown on a variety of spacecraft including sounding rockets and satellites. Typical instrument designs involve a series of trades, depending on the science objectives, type of platform (e.g., spinning or 3-axis stabilized), expected plasma regime where the measurements will be made, available telemetry, budget, etc. In general, ionospheric DC electric field instruments that achieve accuracies of 0.1 mV/m or better, place spherical sensors at large distances (10m or more) from the spacecraft body in order to extend well beyond the spacecraft wake and sheath and to achieve large signal-to-noise ratios for DC and long wavelength measurements. Additional sets of sensors inboard of the primary, outermost sensors provide useful additional information, both for diagnostics of the plasma contact potentials, which particularly enhance the DC electric field measurements on non-spinning spacecraft, and for wavelength and phase velocity measurements that use the spaced receiver or "interferometer" technique. Accurate attitude knowledge enables B times V contributions to be subtracted from the measured potentials, and permits the measured components to be rotated into meaningful geophysical reference frames. We review the measurement technique for both DC and wave electric field measurements in the ionosphere discussing recent advances involving high resolution burst memories, multiple baseline double probes, new sensor surface materials, biasing techniques, and other considerations.

Pfaff, R.↗

Experimental studies of the difference between plasma potentials measured by Langmuir probes and emissive probes in presheaths

The plasma potential measured by cylindrical and planar Langmuir probes has been shown to differ from the plasma potential measured by emissive probes in the neighborhood of the presheath near a negatively biased electrode immersed in a weakly collisional low temperature argon plasma. There are two principal results demonstrated in this paper. First, while it is well known that Langmuir probes cannot reliably measure plasma potentials inside of sheaths, results presented here demonstrate that the problem persists in presheaths, the quasineutral plasma bordering sheaths. It is known that emissive probes analyzed in the limit of zero emission accurately measure the plasma potential in the sheath. It is now clear that they are the only known electrostatic probe technique able to measure the plasma potential accurately throughout the presheath. Second, it is shown that the difference between potential measurements made by Langmuir probes and emissive probes in the body of the plasma, farther than a presheath distance from the boundary, is not proportional to T e , as has been previously claimed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using rf impedance probe measurements to determine plasma potential and the electron energy distribution

Earlier work has demonstrated the usefulness of a network analyzer in plasma diagnostics using spherical probes in the thin sheath limit. The rf signal applied to the probe by the network analyzer is small in magnitude compared to probe bias voltages, and the instrument returns both real and imaginary parts of the complex plasma impedance as a function of frequency for given bias voltages. This information can be used to determine sheath resistance, sheath density profiles, and a technique for measuring electron temperature. The present work outlines a method for finding plasma potential and the electron energy distribution within a limited energy range. The results are compared to those using conventional Langmuir probe techniques. The rf method has general application to diverse areas of plasma investigations when the plasma is uniform and probe dimensions are much less than the size of the plasma. These applications include laboratory and space environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the Plasma near the Plasma Electrode by Probes and Photodetachment in ECR-driven Negative Ion Source

The effect of the plasma electrode bias on the plasma characteristics near the extraction aperture in a large volume hybrid multicusp negative ion source, driven by 2.45 GHz microwaves, is reported. Spatially resolved negative ion and electron density measurements were performed under various pressures (1-4 mTorr) by means of electrostatic probe and photodetachment technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

Detailed plasma potential measurements in a radio-frequency expanding plasma obtained from various electrostatic probes

On-axis plasma potential measurements have been made with an emissive probe in a low pressure (0.044 Pa) rf expanding plasma containing an ion beam. The beam is detected with a retarding field energy analyzer (RFEA), and is seen to disappear at high pressure (0.39 Pa). The emissive probe measurements are in very good agreement with corresponding measurements made with two separate RFEAs, and the results indicate that the floating potential of the strongly emitting probe gives an accurate measure of the plasma potential under the present conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density and electron temperature measurement in a bi-Maxwellian electron distribution using a derivative method of Langmuir probes

In plasma diagnostics with a single Langmuir probe, the electron temperature T{sub e} is usually obtained from the slope of the logarithm of the electron current or from the electron energy probability functions of current (I)-voltage (V) curve. Recently, Chen [F. F. Chen, Phys. Plasmas 8, 3029 (2001)] suggested a derivative analysis method to obtain T{sub e} by the ratio between the probe current and the derivative of the probe current at a plasma potential where the ion current becomes zero. Based on this method, electron temperatures and electron densities were measured and compared with those from the electron energy distribution function (EEDF) measurement in Maxwellian and bi-Maxwellian electron distribution conditions. In a bi-Maxwellian electron distribution, we found the electron temperature T{sub e} obtained from the method is always lower than the effective temperatures T{sub eff} derived from EEDFs. The theoretical analysis for this is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative measurements of plasma potential with ball-pen and Langmuir probe in low-temperature magnetized plasma

The ball-pen probe (BPP) is used for direct plasma potential measurements in magnetized plasma. The probe can adjust the ratio of the electron and ion saturation currents I{sub sat}{sup −}/I{sub sat}{sup +} to be close to one and therefore its I-V characteristic becomes nearly symmetric. If this is achieved, the floating potential of the BPP is close to the plasma potential. Because of its rather simple construction, it offers an attractive probe for measurements in magnetized plasma. Comparative measurements of plasma potential by BPPs of different dimensions as well as one Langmuir probe (LP) in an argon discharge plasma of a cylindrical magnetron were performed at various experimental conditions. An additional comparison by an emissive probe was also performed. All these types of probes provide similar values of plasma potential in a wide range of plasma parameters. Our results for three different BPP dimensions indicate that the BPP can be operated in a cylindrical magnetron DC argon discharge if the value of the ratio of the magnetic field and neutral gas pressure, B/p, is greater than approximately 10 mT/Pa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic Probe Measurements of Plasma Surrounding Three 25,000 Foot Per Second Reentry Flight Experiments

A high-altitude electrostatic probe experiment is described and data are presented for three RAM C reentries at velocities of approximately 25 OOO feet per second. The electron density profiles inferred from the probe measurements are compared with theoretical calculations, and the probable cause of significant disagreement is briefly discussed. Probe measurements during material-addition sequences for radio-blackout alleviation are presented, and comparisons of probe measurements with other pertinent diagnostic measurements are made.

W Linwood Jones, Jr↗