Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PCC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CO2 Capture Strategies via Mineralization with Industrial Waste Brines

Large coal-fired power plants (>500 MW) account for 30% of global CO2 emissions, and long-term management of this CO2 to is urgently needed mitigate global temperature increases. Sequestration of CO2 within stable mineral carbonates (e.g., CaCO3) represents an attractive emission reduction strategy because it offers a leakage-free alternative to geological storage of CO2 in an environmentally friendly form. We have previously described a mineralization process in which divalent cations are sourced from various waste streams (e.g., produced water and brackish water) and alkalinity is induced via regenerable ion-exchange materials (Bustillos et. al. Frontiers in Energy Research. 2020, 8, 352). In our process, aqueous carbonate-bearing streams with pH > 8 are produced by contacting fresh water and carbon dioxide with various ion-exchange materials (e.g., Na form zeolites or ion exchange resins). These streams are mixed with produced water containing varying concentrations (~0.01 – 1.0 M) of Ca2+ leading to the precipitation of solid calcium carbonate (PCC). This process has the advantages of using regenerable solids in a simple and continuous process to increase the pH of water by ion exchange instead of relying on the consumption of costly and unsustainable sources of alkalinity (e.g., sodium hydroxide). While once-through column experiments showed the above benefits, the same were yet to established in a steady-state process with recycle streams. In this work, we set up a process simulation to quantify the energy requirements and CO2 emissions associated with the process and seek optimal produced water compositions and CO2 concentrations (5 – 20 vol%). The process simulation was set up in ASPEN Plus using eRNTL as the thermodynamic property method and sequential modular strategy. Ion exchange alkaline solution was simulated using sodium hydroxide and validated against the experimental data obtained from once-through kinetic experiments. Nanofiltration and reverse osmosis membrane steps were also implemented for the separation of divalent cations and production of fresh water and a regeneration stream following mineralization. Sensitivity analysis was carried out using a range of produced water compositions (0.01 – 1.0 M Ca2+, 0.001 – 0.15 M Mg2+, 0.5 – 3.5 M Na+ and 0.0004 – 0.002 M Fe2+) according to the United States Geological Survey (USGS) database. Calcium carbonate yields increased with increasing CO2 concentrations and were maximized using produced water compositions with larger Ca2+ concentrations. Maximum calcium carbonate yields produced at 5 vol%, 12 vol% and 20 vol% CO2 were 2.3 mmol/L, 5.5 mmol/L, and 9.3 mmol/L, respectively, with the formation of brucite (a magnesium hydroxide phase, Mg(OH)2) and goethite (an iron hydroxide phase, FeOOH) as the primary contaminant phases (99% calcite, 0.6% brucite, 0.4% goethite), which agree with phases detected by XRD experimentally. These results indicate high purity calcium carbonate can be precipitated using industrial waste streams. Consequentially, energy consumption and net CO2 emissions were minimized where precipitated calcium carbonate was maximized for all produced water compositions and CO2 concentrations. Minimum energy consumptions were 0.21 kWh/ton CO2 processed, with 98% of the energy input required coming from the membrane filtration steps. Produced water compositions with large Na+ concentrations (> 0.5 M) were effective at reducing energy consumptions due to faster regeneration time of ion exchange materials. Additionally, calculated net CO2 emissions were negative for the process and ranged from -0.02 kg/ton CO2 to -0.15 kg/ton CO2 processed, indicating a low emission process. We will also present techno-economic assessment showing the economic benefits of the current process as an alternative to the addition of stoichiometric bases to induce alkalinity for the precipitation of CaCO3.

Simonetti, Dante↗

CERES: CRISPR Engineering for the Rapid Enhancement of Strains

Previous strain development efforts for cyanobacteria have failed to achieve the necessary productivities needed to support economic biofuel production. We proposed to develop CRISPR Engineering for Rapid Enhancement of Strains (CERES). We developed genetic and computational tools to enable future high-throughput screening of CRISPR interference (CRISPRi) libraries in the cyanobacterium Synechococcus sp. PCC 7002, including: (1) Operon- SEQer: an ensemble of algorithms for predicting operon pairs using RNA-seq data, (2) experimental characterization and machine learning prediction of gRNA design rules for CRISPRi, and (3) a shuttle vector for gene expression. These tools lay the foundation for CRISPR library screening to develop cyanobacterial strains that are optimized for growth or metabolite production under a wide range of environmental conditions. The optimization of cyanobacterial strains will directly advance U.S. energy and climate security by enabling domestic biofuel production while simultaneously mitigating atmospheric greenhouse gases through photoautotrophic fixation of carbon dioxide.

09 BIOMASS FUELS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant

A comprehensive front-end engineering design (FEED) study has been undertaken for a post-combustion capture (PCC) unit located at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in a full and unredacted FEED study report with all supporting documents, numbering over 150, also publicly available.

20 FOSSIL-FUELED POWER PLANTS↗

Photovoltaic Plant and Battery Energy Storage System Integration at NREL's Flatirons Campus

Although utility-scale solar photovoltaic (PV) power plants are becoming a cost-effective energy resource, there is belief within the energy industry that the increasing penetrations of PV technologies could potentially impact grid reliability. This is due to the variability across timescales, the forecast uncertainty of the solar energy resource, and the impacts on both distribution and transmission systems. This can cause utilities to severely limit PV installations or to assign PV integration costs when considering a least-cost portfolio of resources. As California and other regions in the United States are marching toward fulfilling - and probably exceeding - their renewables portfolio standards goals, grid operators are beginning to face operational challenges that could have implications for existing renewable and nonrenewable generators and that will shape opportunities for future projects. In this work, we focused on developing controls and conducting demonstrations for AC-coupled PV-battery energy storage systems (BESS) in which PV and BESS are collocated and share a point of common coupling (PCC).

14 SOLAR ENERGY↗

Front End Engineering Design of Linde-BASF Advanced Post-Combustion CO 2 Capture Technology at a Southern Company Natural Gas-Fired Power Plant (Final Scientific/Technical Report)

This document details the execution of Cooperative Agreement DE-FE0031847, “Front End Engineering Design of Linde-BASF Advanced Post-Combustion Carbon Dioxide (CO 2 ) Capture Technology at a Southern Company Natural Gas-Fired Power Plant” during the period of 10/1/2019 to 6/30/2022. The project was funded by the U.S. Department of Energy’s Office of Fossil Energy and Carbon Management (FECM) and managed by the National Energy Technology Laboratory (NETL). Southern Company Services, Inc. (SCS) was the prime recipient and led the project team. Other members of the project team included Linde, Inc. (Linde), Linde Engineering – Dresden (LED), and BASF. The overall goal of the project was to complete a front-end engineering design (FEED) study for installing the Linde-BASF post-combustion capture (PCC) technology at an existing domestic natural gas-fired combined cycle (NGCC) power plant within Southern Company’s portfolio of assets. The CO 2 capture plant was to be of commercial scale (at least 375 MWe) and include process units for pre-conditioning of the flue gas system, the CO 2 capture plant island, storage vessels, the CO 2 compression train, and any necessary components for integration into the NGCC plant. Mississippi Power’s Plant Daniel Unit #4 was chosen as the host site for the FEED with the target of capturing 90% of CO 2 emissions from the existing combustion turbines. The information produced by the FEED was used to develop a cost estimate of +/- 15% accuracy. Capital costs, excluding financing, are estimated at approximately $\$752$ million dollars (2021). The execution of a project based on this FEED study has an estimated duration of almost five years.

03 NATURAL GAS↗

Representative-cell-based Modeling of HTTF in SAM

Although the current nuclear power market is primarily occupied by the light water reactors (LWRs), the TRISO-fueled helium-cooled graphite-moderated high temperature gas reactors (HTGRs) are drawing growing attention as the nuclear power industry marches towards more advanced systems. Compared to that of conventional LWRs, the thermal hydraulics of HTGR cores show extra complexity from their multi-scale heat transfer mechanisms with varying importance during different operation modes or transient stages. The modeling of HTGR cores for the system analysis purpose therefore faces the challenge of reaching reasonable fidelity and accuracy while maintaining sufficient simplicity. Previous development and validation efforts have demonstrated that a “2-D ring model” with reasonable performance can be implemented in the System Analysis Module (SAM) for prismatic HTGR cores. In the current project, an alternative modeling methodology based on “representative cells” is proposed for the typical prismatic core of HTGRs. Different from the previous ring model approach, the proposed methodology first separately models and then combines the small- and large-scale thermal conductions, by connecting representative local heat transfer units (cells) with effective core- wise thermal resistance. A modeling practice for an integral high-temperature test facility (HTTF) elaborates the modeling details. Steady-state validation of the resultant candidate model is performed against a higher-resolution benchmark from a 3D-1D coupled simulation, which shows satisfactory prediction with reasonably captured global parameters and well-represented temperature fields. A postulated pressurized conduction cooldown (PCC) is also simulated and analyzed, demonstrating the model’s capability of transient prediction with physically captured phenomena resolved in both small and large temporal and spatial scales. In general, the current work achieves a preliminary success in proposing a methodology using representative cells to model prismatic HTGR cores in SAM. Future efforts are envisioned with more validation activities and with potential modeling improvements to eventually achieve the high confidence on a high-fidelity robust modeling methodology with reasonable accuracy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Gas-Cooled Pebble-Bed Reactors Running In And Transient Modeling Capabilities Demonstration

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor (HTGR) applications. The first part of this effort focuses on the running-in verification of Griffin's multiphysics capabilities, specifically for simulating the evolution of Pebble Bed reactor cores from startup to equilibrium. In the absence of validation data, code-to-code comparisons are conducted with Kugelpy, showing good agreement for key quantities like maximum power density and fresh core k-eigenvalue predictions. However, discrepancies in equilibrium core predictions suggest potential issues with cross sections, underscoring the need for further refinement and evaluation. The HTTF system analysis code benchmark involves RELAP5-3D, SAM, and GAMMA+ to assess their predictive capabilities for HTTF behavior under both normal operation and pressurized conduction cooldown (PCC) transient conditions. While there is good agreement in predicting major parameters such as coolant temperature, solid temperature, and flow distribution, discrepancies in transient behavior highlight differences in modeling approaches, nodalizations, and heat transfer models. The HTTF lower plenum CFD benchmark employs nekRS to simulate flow mixing phenomena, successfully capturing relevant flow physics and demonstrating mesh independence in complex geometries. Preliminary results suggest a relatively uniform temperature field but significant unsteadiness in the flow, requiring time-averaging analyses. The GPBR200 system analysis code benchmark uses SAM's core channel and porous media models, incorporating an RCCS loop for decay heat removal. During steady-state and transient conditions, including protected de-pressurized and pressurized loss of forced cooling (DLOFC and PLOFC), both models show good agreement in predicting temperature profiles and key parameters. Notably, while the core channel model underpredicts convective heat transfer effects, both models maintain temperatures well below the TRISO fuel safety limit. These benchmarking efforts collectively enhance the predictive capabilities of the tools used in HTGR design and safety analysis, guiding developments to improve their accuracy and applicability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital Droplet PCR and Mesocosm-Based Methods to Evaluate Biocontainment Strategies in a Native Soil Ecosystem

Genetically modified industrial production microbes and their associated bioproducts have emerged as an integral component of a sustainable bioeconomy. However, the rapid development of these innovative technologies raises biosecurity concerns, namely, the risk of environmental escape. Thus, the realization of a bioeconomy hinges not only on the development and deployment of microbial production hosts, but also on the development of secure biosystems and biocontainment designs. Current laboratory-based biocontainment testing systems do not accurately reflect the complexities found in natural environments, necessitating an environmentally relevant analysis pipeline that allows for the detection of rare escapees within a complex soil microbiome and differentiation between closely related strains. To this end, we have developed an approach that utilizes soil mesocosms and integrated digital droplet PCR (ddPCR) system to evaluate the efficacy of novel biocontainment strategies. We demonstrate the utility of this approach by modeling contamination with industrial microbial chasses versus their biocontained counterparts. Here we demonstrate the broad utility of this system by highlighting findings from strains of Saccharomyces cerevisiae that are contained with an inducible toxin anti-toxin system, strains of Synechocystis sp. PCC 6803 contained via gene knockout or toxin anti-toxin system, and strains of Escherichia coli that are contained via genomic recoding. We also show that ddPCR can be used to detect gene copies from E. coli equal to those counted by traditional spot plating assays. The resultant data demonstrates that this system has broad utility across diverse microbial chassis and biocontainment strategies and enables researchers to track the fate of our contaminating microbe with high sensitivity in the soil. The findings presented here support the use of this mesocosm-based approach to assess the environmental impact of industrial microbes and to validate biocontainment strategies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phenomena Identification and Ranking Tables for High Temperature Gas-Cooled Microreactors

Micro-scaled high-temperature gas-cooled reactors (micro-HTGRs) offer a promising option for reliable power in remote or off-grid locations. While the safety characteristics of modular HTGRs have been widely studied, a micro-HTGR configuration alters several key thermal-fluid phenomena that govern both normal operation and passive decay-heat removal. In many proposed concepts, the reactor vessel is oriented horizontally and integrated into an ISO shipping container to enhance transportability and modular deployment. This report documents a Phenomena Identification and Ranking Table (PIRT) exercise focused on the thermal hydraulic safety phenomena relevant to all micro-HTGRs. The objective is to systematically identify, describe, and rank the importance, uncertainty, and modeling complexity of the key phenomena that control core and vessel temperatures during normal operation, pressurized conduction cooldown (PCC), and depressurized conduction cooldown (with air ingress) conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Timestamp Error Detection and Estimation for PMU Data based on Linear Correlation between Relative Phase Angle and Frequency

Time synchronization is essential to synchro-phasor-based applications. However, Timestamp Error (TE) in synchrophasor data can result in application failures. This paper proposes a method for TE detection based on the linear correlation between frequency and relative phase angle. The TE converts the short-term relative phase angle from noise-like signal to one that linear with the frequency. Pearson Correlation Coefficient (PCC) is applied to measure the linear correlation and then detect the timestamp error. The time error is estimated based on the variation of frequency and relative phase angle. Case studies with actual synchrophasor data demonstrate the effectiveness of TE detection and excellent accuracy of TE estimation.

Yu, Wenpeng↗

Microbial Co-Culture Control Proteomics (MC-DP1)

Co-cultured S. elongatus PCC 7942 CscB/SPS and R. toruloides IFO0880 presented as an effective photosynthesis-driven biofuel production platform. The goal of this experiment was to understand the molecular mechanism of this co-culture system at redox post-translational modification level. The redox proteome of the co-cultured strains was compared to a mono-cultured S. elongatus in light or dark conditions. Samples were processed using a resin-assisted capture (RAC) workflow with TMT labeling to enrich and quantify modified cysteines at proteome level. The datasets were generated by a Q Exactive Plus Orbitrap Mass Spectrometer coupled with a Waters nanoAcquity UPLC, then searched by MSGF+ for downstream redox PTM analysis.

Source record↗

The survivor strain: isolation and characterization of Phormidium yuhuli AB48, a filamentous phototactic cyanobacterium with biotechnological potential

Despite their recognized potential, current applications of cyanobacteria as microbial cell factories remain in early stages of development. This is partly due to the fact that engineered strains are often difficult to grow at scale. This technical challenge contrasts with the dense and highly productive cyanobacteria populations thriving in many natural environments. It has been proposed that the selection of strains pre-adapted for growth in industrial photobioreactors could enable more productive cultivation outcomes. Here, we described the initial morphological, physiological, and genomic characterization of Phormidium yuhuli AB48 isolated from an industrial photobioreactor environment. P. yuhuli AB48 is a filamentous phototactic cyanobacterium with a growth rate comparable to Synechocystis sp . PCC 6803. The isolate forms dense biofilms under high salinity and alkaline conditions and manifests a similar nutrient profile to Arthrospira platensis ( Spirulina ). We sequenced, assembled, and analyzed the P. yuhuli AB48 genome, the first closed circular isolate reference genome for a member of the Phormidium genus. We then used cultivation experiments in combination with proteomics and metabolomics to investigate growth characteristics and phenotypes related to industrial scale cultivation, including nitrogen and carbon utilization, salinity, and pH acclimation, as well as antibiotic resistance. These analyses provide insight into the biological mechanisms behind the desirable growth properties manifested by P. yuhuli AB48 and position it as a promising microbial cell factory for industrial-scale bioproduction[221, 1631].

59 BASIC BIOLOGICAL SCIENCES↗