Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Quantifications of growth rate and particle size of magnesium silicate hydrate cement using small‐angle X‐ray scattering

The focus of recent research on cement binders has shifted to alternatives such as magnesium silicate hydrate (M-S-H) to mitigate the environmental impact of conventional concrete production. However, a detailed understanding of the morphology and growth rate of M-S-H, which informs its applicability as a cementing agent, is lacking. These properties are important as they influence cement hydration and consequently the development of macroscopic properties. Here, in this study, the particle size distribution and growth rate of M-S-H synthesized by mixing aqueous stock solutions were analyzed using synchrotron-based small-angle X-ray scattering. The reaction solutions contained dissolved magnesium and silicon with concentrations ranging from 2 to 500 mM, corresponding to saturation indices with respect to M-S-H endmembers, M 0.75 -S-H and M 1.50 -S-H, between 5.8 and 10.3. The precipitation rates of M-S-H align with affinity-based kinetic models and can be described by the following equations: For M 0.75 -S-H: 𝑟 M 0.75 −S−H =10 −9.54±0.70 ⁢(Ω$^{0.59±0.08}_{M_{0.75}⁢\textrm{SH}}$−1), and for M 1.50 -S-H: 𝑟 M 1.50 −S−H =10 −7.56±0.37 ⁢(Ω$^{0.34±0.04}_{M_{1.50}⁢\textrm{SH}}$−1), where 𝑟 is the rate in mol/L/s, and Ω represents the saturation ratio with respect to M-S-H. Moreover, we observed that changing the [Mg]/[Si] ratio affects particle size, a trend that cannot be fully explained by changes in the saturation index alone. These insights are critical for improving the predictability and control of cementation in concrete that utilizes M-S-H-based binders.

M-S-H↗

Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of ~1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

Cooper, Bonnie L.↗

Apolipoprotein A-I modulates HDL particle size in the absence of apolipoprotein A-II

Human high-density lipoproteins (HDLs) are a complex mixture of structurally related nanoparticles that perform distinct physiological functions. We previously showed that human HDL containing apolipoprotein A-I (APOA1) but not apolipoprotein A-II (APOA2), designated LpA-I, is composed primarily of two discretely sized populations. Here, we isolated these particles directly from human plasma by antibody affinity chromatography, separated them by high-resolution size-exclusion chromatography and performed a deep molecular characterization of each species. The large and small LpA-I populations were spherical with mean diameters of 109 Å and 91 Å, respectively. Unexpectedly, isotope dilution MS/MS with [ 15 N]-APOA1 in concert with quantitation of particle concentration by calibrated ion mobility analysis demonstrated that the large particles contained fewer APOA1 molecules than the small particles; the stoichiometries were 3.0 and 3.7 molecules of APOA1 per particle, respectively. MS/MS experiments showed that the protein cargo of large LpA-I particles was more diverse. Human HDL and isolated particles containing both APOA1 and APOA2 exhibit a much wider range and variation of particle sizes than LpA-I, indicating that APOA2 is likely the major contributor to HDL size heterogeneity. We propose a ratchet model based on the trefoil structure of APOA1 whereby the helical cage maintaining particle structure has two “settings”—large and small—that accounts for these findings. This understanding of the determinants of HDL particle size and protein cargo distribution serves as a basis for determining the roles of HDL subpopulations in metabolism and disease states.

59 BASIC BIOLOGICAL SCIENCES↗

A correction procedure for self-induced velocity of a finite-sized particle in two-way coupled Euler–Lagrange simulations

The importance of incorporating a correction to undo the self-induced perturbation velocity of a particle, when its size becomes comparable to the Eulerian grid, in a two-way coupled Euler–Lagrange (EL) simulation is now well appreciated. The present work improves upon the prior correction procedures in a few important ways. First, the past correction procedures have been scalar-based with the assumption that the quasi-steady force is the source of self-induced velocity perturbation. Here we generalize to a vector correction procedure and thereby the directions of feedback force and relative velocity can be different. This allows the correction procedure to be used even in the presence of added-mass, history, and lift forces. Second, the effect of a nearby wall has been systematically included in the correction procedure. The correction procedure depends on fundamental Oseen solutions of streamwise and transverse regularized feedback forces. We present a Fourier transform-based analytical approach to obtaining these regularized Oseen solutions. We also present a step-by-step numerical procedure for obtaining the Oseen solutions in any EL code. With the analytical or numerical Oseen functions, the correction procedure can be easily implemented in any EL code. Iterations are required in solving the implicit correction equations and it is demonstrated that the correction procedure converges rapidly within three or four iterations. In conclusion, a simple empirical approach is also presented to account for unsteady effects in the correction procedure.

97 MATHEMATICS AND COMPUTING↗

Particle size and velocity measurement by laser anemometry

The use of a forward scattering Laser Anemometer system for the measurement of particle diameters larger than the fringe spacing is investigated. A systematic calibration experiment demonstrates a direct relationship between signal amplitude and particle diameter for transparent particles between 30 microns and 240 microns in diameter. A light scattering analysis confirms these measurements and indicates how the range of particles which can be measured using the peak (mean) signal depends on the optical arrangement and particle properties. On the basis of this work a real time Laser Anemometer signal processor is modified so that the peak of the mean of each signal can be measured. A method of correcting data for the effect of particles which do not go through the center of the measurement volume is derived. Good agreement is found between particle size distributions measured in sprays by using the Laser Anemometer and size distributions measured by collecting the particles on a slide and using an image analysis computer.

Yule, A. J.↗

Particle Size Distributions in Atmospheric Clouds

In this note, we derive a transport equation for a spatially integrated distribution function of particles size that is suitable for sparse particle systems, such as in atmospheric clouds. This is done by integrating a Boltzmann equation for a (local) distribution function over an arbitrary but finite volume. A methodology for evolving the moments of the integrated distribution is presented. These moments can be either tracked for a finite number of discrete populations ('clusters') or treated as continuum variables.

Paoli, Roberto↗

Predicting Particle-Size Distributions in Fuel-Cell Inks

Prediction of the catalyst-activated carbon particle sizes of fuel-cell inks remains a critical challenge in enhancing the performance and durability of fuel cells. The performance and structural integrity of the catalyst layers in the cell depend not only on the properties of the ionomer, but also on the carbon supports that host the catalyst. To investigate how these carbon aggregate structures form, we present a model that calculates the cooperative size distributions of ionomer and carbon aggregates in various water/alcohol mixtures and compares those results to available experimental data. Aggregation of both the suspended ionomers and the carbon particles is interwoven as the carbon aggregation depends heavily on the ionic strength of its environment, namely protons dissociating from the ionomer’s sulfonic-acid-group side chains. We demonstrate that the surrounding mixed solvent as well as Nafion TM binder concentration strongly influence the degree of aggregation for carbon particles. The validated model provides a framework for exploring aggregation under a wide range of conditions for various electrochemical-technology inks.

Srivastav, Harsh [University of California, Berkel↗

A global data set of soil particle size properties

A standardized global data set of soil horizon thicknesses and textures (particle size distributions) was compiled. This data set will be used by the improved ground hydrology parameterization designed for the Goddard Institute for Space Studies General Circulation Model (GISS GCM) Model 3. The data set specifies the top and bottom depths and the percent abundance of sand, silt, and clay of individual soil horizons in each of the 106 soil types cataloged for nine continental divisions. When combined with the World Soil Data File, the result is a global data set of variations in physical properties throughout the soil profile. These properties are important in the determination of water storage in individual soil horizons and exchange of water with the lower atmosphere. The incorporation of this data set into the GISS GCM should improve model performance by including more realistic variability in land-surface properties.

Webb, Robert S.↗

Laser diffraction particle sizing: Instrument probe volume relocation and elongation

The effective probe volume of laser diffraction particle sizing instruments depends on many instrument parameters. In particular the probe volume axial boundaries and its location along laser beam are essentially defined by the onset of a vignetting effect where light scattered at large angles from small particles misses the transform lens. This vignetting effect results in a probe volume that must be inconveniently close to the lens in order to detect smaller diameter particles (less than 100 micrometers). With the addition of an appropriately designed Keplerian telescope, the probe volume may be relocated and elongated. The theory of operation of this supplemental optical system is described. Design considerations for these supplemental optical systems are described, including recommendations for lens specifications, assembly and use. An image transfer system is described which has been designed for use on a Malvern 2600HSD instrument. Experimental validation of this image transfer system is described.

Anderson, Robert C.↗

An Initial Analysis of the Pixel-Level Uncertainties in Global MODIS Cloud Optical Thickness and Effective Particle Size Retrievals

Moderate Resolution Imaging Spectroradiometer (MODIS) retrievals of cloud optical thickness and effective particle radius employ well-known solar reflectance techniques using pre-calculated reflectance look-up tables. We evaluate the quantitative uncertainty in simultaneous retrievals of cloud optical thickness and particle size for this type of algorithm. The technique uses sensitivity calculations derived from the reflectance look-up tables, coupled with estimates for the effect of various error terms on the uncertainty in inferring the actual cloud-top reflectance. The error terms include the effects of instrument calibration, surface spectral albedo, and atmospheric corrections on both water and ice cloud retrievals. Because particle shapes in ice clouds are highly variable, the effect of particle shape is analyzed separately with a more approximate method. Results will deal exclusively with pixel-level uncertainties associated with plane-parallel clouds; real-world radiative departures from a plane-parallel model are an additional consideration. While we demonstrate the uncertainty technique with operational 1 km MODIS retrievals from the Terra and Aqua satellite platforms, the technique is applicable to any reflectance-based satellite- or air-borne sensor retrieval using similar spectral channels.

Platnick, S.↗

Subcentimeter-size particle distribution functions in planetary rings from Voyager radio and photopolarimeter occultation data

Analysis of measurements of the scattered and direct components of Voyager 1 radio occultation signals at 3.5 and 13 cm wavelengths yield estimates of the distribution functions of supracentimeter-size particles and thickness of relatively broad regions in Saturn's rings. If mearurements of signal amplitude at a shorter wavelength are combined with the previously analyzed data, the shape of the distribution functions characterizing the smaller particles can be constrained. If size distributions of arbitrary form were considered, many solutions are found that are consistent with the three available observations of signal amplitude. The best-fit power law was calculated to the three observations at three wavelengths for several of the embedded Saturn ringlets. Mie scattering theory predicts that the measured phase of the radio occultation signal is highly sensitive to particles ranging from 0.1 to 1.0 wavelengths in size, thus additional constraints on the subcentimeter-size distribution functions for both the Saturn and Uranus rings can in principle be derived from radio phase measurements.

Zebker, Howard A.↗

Development of Parameters for the Particle Size Distribution of TATB

Laser light scattering (LLS), manual counting of scanning electron microscopy (SEM) images, and reduction of SEM images using ImageJ (open source program) to determine Feret (caliper) diameters were applied to determine particle size distribution (PSD) of four preparations of 1,3,5‐triamino‐2,4,6‐trinitrobenzene (TATB) and yttria‐stabilized zirconia (YSZ), an SEM certified standard. Mie theory was used to reduce the LLS data. The spherical nature of the YSZ made it a good candidate for LLS. Variations in n , the refractive index, and iκ, the imaginary component, produced very little change in the PSD. However, changing the carrier liquid from H 2 O to a 40% aqueous sucrose solution, thereby changing the carrier refractive index, n 0 , substantially affected the PSD. The Mie complex refractive indices for the YSZ were n = 2.200, iκ = 0.100, with a 40% aqueous sucrose solution, n 0 = 1.400. The triclinic crystal structure of TATB made refractive index determinations more difficult, so a study was conducted varying Mie parameters and comparing them to the same data reduced using the Fraunhofer theory. Changing the n and κ parameters produced PSD with a small concentration of particles less than 1 µm in size or none in this range. SEM images, Feret data, manual counting, and Fraunhofer data reduction indicate particles less than 1 µm are probably < 5% in concentration. The final selection of Mie parameters for TATB was n = 2.283, iκ = 0.1, and suspension medium, n 0 = 1.330. Finally, computations, using density functional theory produced similar parameters.

Feret diameter↗

Computer measurement of particle sizes in electron microscope images

Computer image processing techniques have been applied to particle counting and sizing in electron microscope images. Distributions of particle sizes were computed for several images and compared to manually computed distributions. The results of these experiments indicate that automatic particle counting within a reasonable error and computer processing time is feasible. The significance of the results is that the tedious task of manually counting a large number of particles can be eliminated while still providing the scientist with accurate results.

Hall, E. L.↗

Let’s Stick Together: Interplay of Moisture, Particle Size, and Anatomical Fraction in the Flowability of Corn Stover Crumbles

Handling of agricultural waste biomass feedstocks (such as corn stover) is a persistent challenge in the production of biofuels and chemicals at integrated biorefineries. Inconsistent flowability and high feedstock variability creates equipment downtime and processing challenges. This work investigates the influence of anatomical fractionation and moisture content on the bulk solids handling behavior of corn stover crumbles. A combination of rotational shear testing, tribological measurements, and surface and sorption characterization techniques (inverse gas chromatography (IGC), dynamic vapor sorption (DVS), and electron microscopy) were used to evaluate the contributions of particle composition, size, and surface properties to flow behavior. Shear and frictional testing revealed that moisture content has the greatest effect on flowability, significantly increasing unconfined yield strength (ƒ c ) and reducing the flow function coefficient (F F C), regardless of anatomical fraction. While differences in surface energy were observed between fractions, particularly in polar contributions (γ AB ), these did not correspond to meaningful differences in flow behavior. Coarser 6 mm particles exhibited poorer flow performance than 4 mm crumbles, likely due to broader particle size distributions and increased particle interlocking. Taken together, these results suggest that anatomical fractionation provides minimal benefit from a bulk handling perspective. Moisture content and particle size heterogeneity dominate handling behavior, reinforcing the utility of unfractionated corn stover in processing environments. These insights can inform the design of more efficient and reliable feedstock processing systems for agricultural biomass in integrated biorefineries.

09 BIOMASS FUELS↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM&rsquo;s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 &micro;m. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗