Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical constants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

Crystal Growth of Quaternary RE 2 EuSi 2 S 8 ( RE = Ce–Nd, Sm, Gd, Tb) Using Flux-Assisted Boron Chalcogen Mixture (BCM) Method: Investigation of Magnetic and Luminescence Properties

A series of quaternary rare-earth containing thiosilicates with the general formula RE 2 EuSi 2 S 8 (RE = Ce–Nd, Sm, Gd, Tb) has been synthesized via the flux-assisted boron chalcogen mixture (BCM) crystal growth method. High-quality single crystals were obtained, and their crystal structures were determined by single-crystal X-ray diffraction. The RE 2 EuSi 2 S 8 series crystallizes in the trigonal system, adopting the space group R-3c. Polycrystalline samples were employed for physical property measurements, including magnetic susceptibility measurements, UV–visible diffuse reflectance, and photoluminescent response. Magnetic data of RE 2 EuSi 2 S 8 ( RE = Ce, Nd, and Gd) were collected over the 2–300 K temperature range. The samples were paramagnetic behavior with negative Weiss constants (θ W = −11.05, −10.55, and −1.35 K respectively). Their thermal stability was investigated using thermogravimetric analysis (TGA). Optical band gaps, estimated from diffuse reflectance spectra, were determined to be 2.2(1) eV for Ce 2 EuSi 2 S 8 , 1.8(1) eV for Nd 2 EuSi 2 S 8 , and 1.7(1) eV for Gd 2 EuSi 2 S 8 respectively. Finally, photoluminescence measurements were collected on Ce 2 EuSi 2 S 8 and Tb 2 EuSi 2 S 8 single crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Process Parameter and Build Rate Variations on Defect Formation in Laser Powder Bed Fusion SS316L

Laser powder bed fusion (LPBF) is an additive manufacturing process that has gained interest for its material fabrication due to multiple advantages, such as the ability to print parts with small feature sizes, good mechanical properties, reduced material waste, etc. However, variations in the key process parameters in LPBF may result in the instantiation of porosity defects and variation in build rate. Particularly, volumetric energy density (VED) is a variable that encapsulates a number of those parameters and represents the amount of energy input from the laser source to the feedstock. VED has been traditionally used to inform the quality of the printed part but different values of VED are presented as optimal values for certain material systems. An optimal VED value can be maintained by changing the key process parameters so that various combinations yield a constant value. In this study, an optimal constant VED value is maintained while printing SS316L with variable key processing parameters. Porosity analysis is performed using optical microscopy, as well as X-ray computed tomography, to reveal the volume density and distribution of those pores. Two primary defect categories are identified, namely lack of fusion and porosity induced by balling defects. The findings indicate that, even at optimal VED, variations in process parameters can significantly influence defect type, underscoring the sensitivity of defect formation to the variation of these parameters. Furthermore, a minor change in the build rate, driven by adjustments in process parameters, was found to influence defect categories. These findings emphasize that fine tuning the process parameters and build rate is essential to minimize defects. Finally, fiducial marks have been identified as a source of unintentional porosity defects. These results enable the refinement of process parameters, ultimately optimizing LPBF to achieve enhanced material density and expedite the printing.

36 MATERIALS SCIENCE↗

Polariton panorama

Abstract In this brief review, we summarize and elaborate on some of the nomenclature of polaritonic phenomena and systems as they appear in the literature on quantum materials and quantum optics. Our summary includes at least 70 different types of polaritonic light–matter dressing effects. This summary also unravels a broad panorama of the physics and applications of polaritons. A constantly updated version of this review is available at https://infrared.cni.columbia.edu .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-temperature superconductivity in LaH 10

The recent discovery of a high critical temperature $T_c$ in compressed H 3 S has been followed by the prediction of Liu et al. of $T_c$ ≈ 250 K in the clathrate LaH 10 structure. This report has been confirmed experimentally by Somayazulu et al. and Drozdov et al. Additional theoretical work by Wang et al. and Quan et al. further established the mechanism of electron-phonon interaction and the dominant role of hydrogen. In the present Rapid Communication we follow the classic McMillan paper, which separates the electron and phonon contributions to the electron-phonon coupling λ. We first compute the numerator of McMillan's expression, the Hopfield parameter η, using the theory of Gaspari and Gyorffy (GG), and obtain the force constants in the denominator from Wang et al. and Quan et al. The resulting λ is used in the Allen-Dynes equation to calculate $T_c$. The value of $T_c$ reaches a maximum in the range of 236–263 K at pressures of 255 GPa and decreases for smaller or larger pressures. Further, we provide a thorough analysis of the different terms of the GG equation and draw the conclusion that the $\textit{sp}$ channel of the hydrogen is the most important contribution to obtain high values of $T_c$ in this material. Consistent with Wang et al., we find large values of λ that decrease with increasing pressure. In addition, we find that the hydrogen sites are the largest contributors to the total value of the coupling constant λ. That is, the acoustic mode associated with La contributes only 2% to the total λ, while the optic modes associated with H contribute 18% for the H1 site and 80% for the H2 site. These relative contributions to λ are consistent with those given by Wang et al. and by Quan et al. Thus, our results strongly support the view that LaH 10 is a metallic hydrogen superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak

An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v ⊥ and v || , while the X2 mode is dominantly sensitive to suprathermal electrons of a high v ⊥ . Finally, the modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Transport in Stochastic Media with Random Chord Length Distributions

Thermal radiation transport computations in binary Markovian random mixtures rely almost exclusively on the Levermore-Pomraning (LP) model which is obtained by applying a heuristic closure to the ensemble averaged random medium transport equation. The validity of this model has been extensively tested by comparing numerical results over a broad parameter range (material types and mixing parameters) against benchmark solutions in planar geometry. The conditions under which the LP-model provides useful results and when it breaks down are now well established, but work to date has been largely restricted to homogeneous mixing statistics, i.e., the mean chord lengths of both materials are taken to be spatially constant. In recent work, this limitation was relaxed by allowing the mean chord lengths and, in a consistent fashion, the volume fractions in the LP-model to vary spatially and in a follow-up investigation benchmark solutions were obtained by ensemble averaging results over material realizations sampled from a nonhomogeneous Poisson process (NHPP). Numerical experiments in rod geometry with specifically linear and quadratic spatial dependence of chord lengths showed that the material averaged radiation intensities vary nonmonotonically with depth into the medium, in stark contrast to solutions obtained assuming uniform chord lengths. Moreover, depending on the local optical thickness and strength of scattering, the LP-model results showed locally more nuanced deviations from the benchmark solutions than was the case with constant chord lengths. These limited numerical investigations highlight the nontrivial qualitative and quantitative consequences of nonhomogeneous mixing statistics, in particular that closure approximations may not be uniformly valid or invalid over the problem domain.

42 ENGINEERING↗

The effect of WAAM process parameters on process conditions and production metrics in the fabrication of single-pass multi-layer wall artifacts

The present work seeks to understand the impact of varying dwell time and input deposition power on part quality and overall production time for wire arc additive manufacturing. In this work, multi-layer wall geometries were deposited under different input power conditions without affecting the material deposition rate by setting traverse speed and wire feed speed constant and varying the contact tip-to-workpiece distance and the deposition power settings. Current and voltage data and optical imaging of the deposition zone were captured in situ, and wall geometry was characterized using laser scanning, so to understand the applicability of these methods for determining part height in situ. Furthermore, the present results demonstrate that alternating dwell times with lower input deposition power can result in significantly reduced overall production time and minimal material underbuilding, despite increased deposition geometry width. Furthermore, it is shown that while elimination of process dwell results in severe underbuilding of the deposition, it also yields the highest production rate for a hybrid-finished (e.g., deposited, machined) wall in terms of mm in build direction per minute and the highest buy-to-fly ratio.

36 MATERIALS SCIENCE↗

Paraxial, Thin-Lens Analysis of Fixed-Tune, Non-Scaling FFAs with Two Magnets per Cell

Fixed-field accelerators (FFAs) have closed orbits that change as a function of beam momentum. It is sometimes useful to avoid various resonances by keeping the tunes constant as these orbits change. A well-known example is the scaling FFA where the entire beam orbit and optics are geometrically scaled as a function of momentum. However, this is stricter than necessary: cells with three or more lenses can have fixed tunes even when the focussing strengths in the lenses change. Recently, Dejan Trbojevic has found a pair of nonlinear magnets that produce fixed tunes and fixed beta functions while not being a scaling FFA. This improves on a more approximate solution in. Notably a scaling FFA would require one magnet to be entirely reverse-bending, whereas the Trbojevic solution does not do this and instead resembles an intermediate point between the traditional scaling field profiles and the nonscaling profiles centred around a momentum with equal and positive fields. This suggests there are at least three levels of stringency that one can apply to a fixed-tune FFA design: 1. Fixed cell tunes (in both planes) as a function of momentum; 2. Fixed optics (beta functions) as a function of momentum; 3. Similarity of all orbits via a scaling symmetry law ↔ traditional scaling FFA. This note studies the interesting case #2 above (#3 being fully characterised by the orbit at a single energy) in the simplest possible example: a cell of two thin lenses in the small angle (paraxial) approximation.

43 PARTICLE ACCELERATORS↗

Improved optical standing-wave beam splitters for dilute Bose–Einstein condensates

Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. Here, in simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

Direct observation of two-dimensional magnons in atomically thin CrI 3

Magnons are collective spin excitations in crystals with long-range magnetic order. The emergent van der Waals magnets provide a highly tunable platform to explore magnetic excitations in the two-dimensional limit with intriguing properties, manifesting from their honeycomb lattice structure and switchable magnetic configurations. Here, we report the direct observation of two-dimensional magnons through magneto-Raman spectroscopy with optical selection rules determined by the interplay between crystal symmetry, layer number and magnetic states in atomically thin CrI 3 . In monolayers, we observe an acoustic magnon mode at ~0.3 meV. It has strict cross-circularly polarized selection rules locked to the magnetization direction that originates from the conservation of angular momentum of photons and magnons dictated by three-fold rotational symmetry. Additionally, we reveal optical magnon modes at ~17 meV. This mode is Raman silent in monolayers, but optically active in bilayers and bulk due to a relaxation of the parity criterion resulting from the layer index. In the layered antiferromagnetic states, we directly resolve two degenerate optical magnon modes with opposite angular momentum and conjugate optical selection rules. From these measurements, we quantitatively extract the spin-wave gap, magnetic anisotropy and intralayer and interlayer exchange constants, and establish two-dimensional magnets as a new platform for exploring magnon physics.

36 MATERIALS SCIENCE↗

High density optical waveguide using hybrid spiral pattern

A hybrid spiral waveguide geometry is proposed that exhibits essentially zero curvature (i.e., infinite bend radius) at the center of the spiral (similar to a Fermat spiral), with the curvature then increasing in value as the spiral moves outward. Advantageously, as the spiral moves away from the center, the spacing between adjacent waveguides quickly approaches a constant value (similar to an Archimedean spiral). This hybrid spiral structure has been found to allow for a high density waveguide to be created with lower loss and requiring a smaller size than many conventional spiral configurations and finds use in optical delay lines, amplifiers and arrayed waveguide gratings.

42 ENGINEERING↗

Metalens formed by structured arrays of atomic emitters

Abstract Arrays of atomic emitters have proven to be a promising platform to manipulate and engineer optical properties, due to their efficient cooperative response to near‐resonant light. Here, we theoretically investigate their use as an efficient metalens. We show that, by spatially tailoring the (subwavelength) lattice constants of three consecutive two‐dimensional arrays of identical atomic emitters, one can realize a large transmission coefficient with arbitrary position‐dependent phase shift, whose robustness against losses is enhanced by the collective response. To characterize the efficiency of this atomic metalens, we perform large‐scale numerical simulations involving a substantial number of atoms (N∼ 5 × 10 5 ) that is considerably larger than comparable works. Our results suggest that low‐loss, robust optical devices with complex functionalities, ranging from metasurfaces to computer‐generated holograms, could be potentially assembled from properly engineered arrays of atomic emitters.

Materials Science↗

The Dark Energy Spectrographic Instrument (DESI) Corrector Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with University College London (UCL) involved both research planning for eventual observing on the DESI telescope; and in the build of the optical corrector, a major part of the instrument. The key major goals of this CRADA were achieved. For survey planning, Drs. Lahav, Abdalla, Peiris, Pontzen and Dr. Farihi were all important contributors to the working groups to which they were assigned. Their modelling efforts, cosmological simulations, target selection and analyses of imaging surveys have been vital in the early planning for targets during commissioning. The major role UCL played in the development of the instrument was performed by Drs. Doel and Brooks. The optical corrector components were developed by scientists and engineers at Lawrence Berkeley National Laboratory and at Fermi National Accelerator Laboratory. UCL was assigned the arduous responsibility for creating the instrumentation necessary to take all the separate components (lenses, cells, rings) and incorporate them, while precisely aligning the optics. Following that, they installed the corrector inside the barrel and shipped everything to the Mayall. It was a great success that the optical barrel arrived safely in good condition. Drs. Doel and Brooks were involved in every step of the fabrication and kept in constant contact with the LBNL DESI Project Manager and Project Director. They were extremely successful in their alignment, which was proved by early observations. First light on the telescope was achieved on October 22, 2020. The first spectrum was taken of a random star at zenith. Shortly thereafter, the telescope slewed to M33 and several spectra were taken there and later in the Persus nebula. It was a major accomplishment for the project.

79 ASTRONOMY AND ASTROPHYSICS↗