Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Polarization angle requirements for CMB B-mode experiments. Application to the LiteBIRD satellite

A methodology to provide the polarization angle requirements for different sets of detectors, at a given frequency of a CMB polarization experiment, is presented. The uncertainties in the polarization angle of each detector set are related to a given bias on the tensor-to-scalar ratio r parameter. The approach is grounded in using a linear combination of the detector sets to obtain the CMB polarization signal. In addition, assuming that the uncertainties on the polarization angle are in the small angle limit (lower than a few degrees), it is possible to derive analytic expressions to establish the requirements. The methodology also accounts for possible correlations among detectors, that may originate from the optics, wafers, etc. The approach is applied to the LiteBIRD space mission. We show that, for the most restrictive case (i.e., full correlation of the polarization angle systematics among detector sets), the requirements on the polarization angle uncertainties are of around 1 arcmin at the most sensitive frequency bands (i.e., ≈ 150 GHz) and of few tens of arcmin at the lowest (i.e., ≈ 40 GHz) and highest (i.e., ≈ 400 GHz) observational bands. Conversely, for the least restrictive case (i.e., no correlation of the polarization angle systematics among detector sets), the requirements are ≈ 5 times less restrictive than for the previous scenario. At the global and the telescope levels, polarization angle knowledge of a few arcmins is sufficient for correlated global systematic errors and can be relaxed by a factor of two for fully uncorrelated errors in detector polarization angle. The reported uncertainty levels are needed in order to have the bias on r due to systematics below the limit established by the LiteBIRD collaboration.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyper-Raman spectroscopy of CeO 2

Cerium dioxide (CeO 2 ) belongs to the fluorite structure group (Oh 5 point group) resulting in one Raman active T 2g mode and two IR active T 1u TO and LO modes. The T 2g Raman band in CeO 2 has been used to probe the symmetric Ce-O vibrational mode of different sized nanoparticulates. Far infrared studies of the Ce-O interactions are difficult to conduct due to low optical transmission, efficiency of the detector and water absorption bands interfering with the measurements. The selection rules of hyper-Raman spectroscopy (HRS) allow the study of IR bands in the far infrared spectral region, such as the motion of the Ce atoms. For the first time, HRS was used to investigate the T 1u TO and LO IR modes in CeO 2 . The position and full-width half-maximum (FWHM) of the TO and LO bands in the HRS spectrum were used to investigate the spectral response in relation to particle size (i.e., phonon confinement). The investigation of CeO2 with HRS provides a research platform for future work in the study of ThO 2 , UO 2 and PuO 2 IR modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Seeing structural evolution of organic molecular nano-crystallites using 4D scanning confocal electron diffraction (4D-SCED)

Abstract Direct observation of organic molecular nanocrystals and their evolution using electron microscopy is extremely challenging, due to their radiation sensitivity and complex structure. Here, we introduce 4D-scanning confocal electron diffraction (4D-SCED), which enables direct in situ observation of bulk heterojunction (BHJ) thin films. 4D-SCED combines confocal electron optic setup with a pixelated detector to record focused spot-like diffraction patterns with high angular resolution, using an order of magnitude lower dose than previous methods. We apply it to study an active layer in organic solar cells, namely DRCN5T:PC 71 BM BHJ thin films. Structural details of DRCN5T nano-crystallites oriented both in- and out-of-plane are imaged at ~5 nm resolution and dose budget of ~5 e − /Å 2 . We use in situ annealing to observe the growth of the donor crystals, evolution of the crystal orientation, and progressive enrichment of PC 71 BM at interfaces. This highly dose-efficient method opens more possibilities for studying beam sensitive soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Analysis of WIRE-21 SPND and Optical Fiber Sensor Measurements

The Wireless Instrumented RB Experiment 2021 (WIRE-21) was a highly instrumented experiment designed to test prototype wireless temperature and pressure sensors developed by Westinghouse Electric Corporation (WEC) in the High Flux Isotope Reactor (HFIR). In addition to these sensors, a suite of other sensors was also integrated into the experiment capsule, including various types of distributed optical fiber sensors and self-powered neutron detectors (SPNDs). This report presents an analysis of the data generated by the SPNDs and optical fiber sensors that were tested under the highest reported neutron flux. The distributed optical fiber sensor results demonstrate that F-doped optical fibers, particularly those inscribed with fs fiber Bragg gratings (FBGs), are capable of surviving fast neutron fluences on the order of 1021 n fast /cm 2 at temperatures relevant to light-water reactors (between 200 and 400°C). However, a significant blue-shift in the optical spectra of these sensors was observed over the course of irradiation which cannot be explained based on the current understanding of radiation-induced compaction in fused silica glass. A mechanistic understanding of this drift has not yet been developed and is proposed as future scope under the Advanced Sensors and Instrumentation program. Of the four SPNDs, only one appeared to operate normally during three cycles of irradiation. A radiation transport model of the experiment in HFIR was used to determine time-dependent neutron flux in this SPND and to calculate the neutron sensitivity of the device. Results showed a cycle averaged sensitivity of 1.5 ×10 -22 and 1.4 ×10 -22 A/nν for the first and third cycles of irradiation, respectively. Additional details pertaining to the optical fibers and SPNDs are included herein.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for all optical electrode interface for bioengineering application

The present disclosure relates to an electro-optical modulator system having a source laser which generates an input optical signal. The input optical signal is received by an electro-optical module. The electro-optical module is implantable into an anatomy and includes a plurality of pixels. Each pixel has associated therewith an electrode and an optical modulator subsystem. The electrode receives electrical signals from the anatomy. The optical modulator subsystem receives the input optical signal and modulates the input optical signal to generate modulated optical output signals in relation to the received electrical signals. A detector subsystem may be used to receive and collect the modulated optical output signals.

Patra, Susant K.↗

Time-Domain Extreme-Ultraviolet Diffuse Scattering Spectroscopy of Nanoscale Surface Phonons

Here, we report the observation of dynamic fringe patterns in the diffuse scattering of extreme ultraviolet light from surfaces, following femtosecond optical excitation. At each point on the detector, the diffuse scattering intensity exhibits oscillations at well-defined frequencies that correspond to surface phonons with wave vectors determined by the scattering geometry, indicating that the optical excitation generates coherent surface phonons propagating in all directions and spanning a wavelength range from 60 to 300 nm. This phenomenon is observed on a variety of samples, including single-layer and multilayer metal films, as well as bulk semiconductors. The measured surface phonon dispersions show good agreement with theoretical calculations. By comparing signal amplitudes from samples with different surface morphologies, we find that the excitation mechanism is linked to the natural surface roughness of the samples. However, the signal is still detectable on extremely smooth surfaces with subnanometer roughness. Our findings demonstrate a simple and effective method for optically exciting coherent surface phonons with nanoscale wavelengths on a wide range of solid samples and establish a foundation for surface phonon spectroscopy in a wave vector range well beyond the limit of conventional surface Brillouin scattering.

Capotondi, F. [Elettra-Sincrotrone Trieste (Italy)↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

Highly efficient terahertz photoconductive metasurface detectors operating at microwatt-level gate powers

Despite their wide use in terahertz (THz) research and technology, the application spectra of photoconductive antenna (PCA) THz detectors are severely limited due to the relatively high optical gating power requirement. This originates from poor conversion efficiency of optical gate beam photons to photocurrent in materials with sub-picosecond carrier lifetimes. Here we show that using an ultra-thin (160 nm), perfectly absorbing low-temperature grown GaAs metasurface as the photoconductive channel drastically improves the efficiency of THz PCA detectors. This is achieved through perfect absorption of the gate beam in a significantly reduced photoconductive volume, enabled by the metasurface. This Letter demonstrates that sensitive THz PCA detection is possible using optical gate powers as low as 5 µW—three orders of magnitude lower than gating powers used for conventional PCA detectors. We show that significantly higher optical gate powers are not necessary for optimal operation, as they do not improve the sensitivity to the THz field. This class of efficient PCA THz detectors opens doors for THz applications with low gate power requirements.

47 OTHER INSTRUMENTATION↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗