Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Advanced Simulation and Computing (FY22 Implementation Plan Rev 0)

The DOE National Nuclear Security Administration (NNSA) Stockpile Stewardship Program (SSP) is an integrated technical program for maintaining the safety, surety, and reliability of the U.S. nuclear stockpile. The SSP incorporates nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. The suite of data analyzed comes from activities including stockpile surveillance, experimental research, and development and engineering programs. This integrated national program requires the continued use of experimental facilities and the computational capabilities to support the SSP missions. These component parts, in addition to an appropriately scaled production capability, enable NNSA to support stockpile requirements. The ultimate goal of the SSP, and thus of the Advanced Simulation and Computing (ASC) Program, is to ensure that the U.S. maintains a safe, secure, and effective strategic deterrent. Specific work activities and scope contained in this Implementation Plan (IP) represent the full-year annual operating plan for FY22. The Initial IP, effective , should be consistent with the Department’s Base Table when operating under a Continuing Resolution (CR). The final IP, effective date TBD, is consistent with the final, enacted appropriation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Discriminating Underground Nuclear Explosions Leading To Late-Time Radionuclide Gas Seeps

Utilizing historical data from the U.S. nuclear test program and freely available barometric pressure data, we performed an analytical barometric-pumping efficiency analysis to determine factors resulting in late-time radionuclide gas seeps from underground nuclear explosions. In this work, we considered 16 underground nuclear explosions with similar geology and test setup, of which five resulted in the measurement of late-time radionuclide gas concentrations at the ground surface. Additionally, the factors we considered include barometric frequency and amplitude, depth of burial, air-filled porosity, intact-rock permeability, fracture aperture, and fracture spacing. The analysis indicates that the best discriminators of late-time radionuclide gas seeps for these explosions are barometric frequency and amplitude and air-filled porosity. While geologic information on fracture aperture and spacing is not available for these explosions, the sensitivity of barometric-pumping efficiency to fracture aperture indicates that it would likely also be a good discriminator.

58 GEOSCIENCES↗

169 Tm(n,$\gamma$) cross section measured at DANCE

During the US nuclear testing program, known tracer materials could be loaded into the device prior to detonation. If those materials had activation products from nuclear reactions, they could be recovered and counted post-test to study how they transmuted during the neutron exposure. This information may be used to try to infer information about the physical conditions during the detonation. These materials are often referred to as “radiochemical detectors” or “radiochemical tracers”. Thulium, which has only one stable isotope, thulium-169, is one such material that may be employed as a detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nondestructive Evaluation (NDE) of Cable Moisture Exposure using Frequency Domain Reflectometry (FDR)

This Pacific Northwest National Laboratory (PNNL) milestone report assesses the capability of frequency domain reflectometry (FDR) to determine electrical cable submergence using PNNL’s Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable/motor test bed. This work includes a review of relevant literature as well as experimental tests. Nuclear power facilities have experienced various electrical cable failures related to water exposure. The current industry response involves actions to de-water cable vaults, manholes, and other cable locations. These efforts require considerable expenditure of resources, which makes it desirable for the industry to have information on cable condition and history regarding their submergence and water exposure (Mantey 2012). Two tests that are gaining favor within the nuclear industry are time-domain reflectometry (TDR) and FDR. These are low-voltage nondestructive tests that can be applied at a cable end. Testing from the cable end is important because local inspection along the cable length is very difficult due to cables being routed within trays, conduits, underground, and through walls. Both TDR and FDR techniques have been shown to locate cable insulation damage due to thermal, radiation, and mechanical damage. FDR measurements are also more sensitive than TDR to temperature changes, low-bend radius bends, and cable contact with various materials, including conductive materials like steel and water. This work evaluates the feasibility to extend FDR testing to characterizing whether an electrical cable is submerged or not and where it may be submerged using PNNL’s ARENA cable/motor test bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Finding of Effect, And Mitigation Documentation for Building 23-620, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15283), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-620 was built in 1968 as office space for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons. In the 1990s, it became a maintenance facility for Reynolds Electrical & Engineering Company (REECo), and eventually, it became the Real Estate Services building in 2004. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-620 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-620 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation Report: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-620 (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) in the Mercury Historic District (MHD, SHPO Resource No. D230). This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

The ASD Scorpius Accelerator at the NNSS. Recruitment Slides for the University of Nevada, Reno [Slides]

The Scorpius Accelerator: Supports the maintenance of the US nuclear stockpile, helps the US not return to nuclear testing, is one of four diagnostics being installed 963 feet below ground, probes subcritical implosions of nuclear material, and supports the validation of LANL and LLNL computer codes. We are searching engineers and scientists with experienced in: Mechanical Engineering, Electrical Engineering, Pulsed Power, Plasma Physics, Controls, Diagnostics, and Fluids and pressure systems.

42 ENGINEERING↗

Testing of an Ultrasonic Thermometer Developed at the Idaho National Laboratory

Ultrasonic thermometry has great potential to improve temperature measurements in irradiation experiments performed in nuclear test reactors. The flexibility of the measurement makes it applicable to a wide range of potential test conditions, in terms of temperature, radiation, and chemical environment. However, the range of several typical ultrasonic thermometer configurations are not well defined. The research described in this document attempts to define an operational envelop for multiple configurations and sensor materials.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Definitions for Testing Whether Evaluated Nuclear Data Relative Uncertainties are Realistic in Size

This document describes various tests that can be used to check whether evaluated relative uncertainties stored in nuclear-data covariances are realistic. To be more specific, these tests check whether nuclear-data uncertainties could be either over- or under-estimated given the input that usually enters the evaluation of nuclear-data mean values and covariances. Warning and error messages on the reliability of nuclear-data uncertainties will result from these tests. If uncertainties of one specific nuclear-data observable trigger warning messages from multiple tests, an evaluator should counter-check the reliability of the relative uncertainties of this particular nuclear-data covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation↗

Electrochemical hydrogen isotope fractionation - fundamental insights leading to process scale up

Introduction Deuterium and tritium, the two isotopes of hydrogen besides protium, are utilized in many industries. Deuterium is routinely used as a nuclear reactor moderator and molecular labeling agent, while tritium is used as an autoradiography label in medical imaging, and in an emerging market for self-powered lighting for watches, exit signs, firearm night-sights and future fusion fuel. Tritium is produced naturally at very low steady-state levels due to cosmic rays, natural nuclear decay reactions, as well as commercial nuclear fission reactors, and terrestrial nuclear testing conducted primarily in the mid-twentieth century. Tritium often accumulates in the heavy water used in nuclear fission reactors and sometimes appears in groundwater near nuclear reactors due to slight leakage from water sources in the reactor. Because of the health and environmental impacts from tritium leaking into the water sources, as well as the value of this precious material, it is desirable to remove and recover as much tritium as reasonably possible from contaminated water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Weapons Radiochemistry: Trinity and Beyond

On July 16, 1945, the Trinity nuclear test exploded in the desert near Alamogordo, New Mexico. A variety of new diagnostic experiments were fielded in an effort to understand the detailed performance of the nuclear device. This paper describes a series of radiochemical experiments that were designed to measure the efficiency and neutron fluence of the test. These experiments, and the scientists who led them, laid the foundation of weapons radiochemistry for decades to come.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A decadal view of the LANL HED/ICF Program [Slides]

The vast majority of nuclear weapon yield is generated in a regime of extreme temperature, pressure, and density. Without explosive nuclear testing, HED experiments on ICF facilities are the only way to approach and probe these extreme conditions that affect nuclear weapon performance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

2020 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The CNTA is the site of an underground nuclear test in 1968 that resulted in residual contamination near the detonation depth of 3200 feet (ft); the contamination requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from DOE’s National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the amended 1996 Nevada Federal Facility Agreement and Consent Order (FFACO) (State of Nevada et al. 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (DOE 2018), also called the Closure Report, originally was completed in January 2016 and revised in October 2018; it describes LM’s plan for long-term postclosure monitoring. This includes monitoring of the radioisotopes of interest and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2018).

54 ENVIRONMENTAL SCIENCES↗

Global Nuclear Explosion Discrimination Using a Convolutional Neural Network

Using P-wave seismograms, we trained a seismic source classifier using a Convolutional Neural Network. We trained for three classes: earthquake P-wave, underground nuclear explosion (UNE) P-wave, and noise. With the current absence of nuclear testing by countries that have signed the Comprehensive Test Ban Treaty, high quality seismic data from UNEs is limited. Even with limited training data, our model can accurately characterize most events recorded at regional and teleseismic distances, finding over 95% signals in the validation set. We applied the model on holdout datasets of the North Korean test explosions to evaluate the performance on unique region and station-source pairs, with promising results. Additionally, we tested on the Source Physics Experiment events to investigate the potential for chemical explosions to act as a surrogate for nuclear explosions. We anticipate that machine-learning models like our classifier system can have broad application for other seismic signals including volcanic and non-volcanic tremor, anomalous earthquakes, ice-quakes or landslide-quakes.

58 GEOSCIENCES↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Mcnab, 2009; Tompson, 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015b) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Carle et al., 2009; Mcnab, 2009; Tompson et al., 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗