Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Wellbore detector with azimuthal and spectral energy resolution

A wellbore inspection device includes a radiation generation source operable to emit neutrons, and a radiation detector fixed relative to the radiation generation source and operable to detect backscattered neutron radiation from a surrounding environment. The radiation detector includes a plurality of individually addressable detector elements arranged in one or more concentric rings. Respective amounts of backscattered neutron radiation detected by the individually addressable detector elements within a ring is indicative of the azimuthal direction of the detected backscattered neutron radiation, and the respective amount of backscattered neutron radiation detected by the individually addressable detector elements of two or more concentric rings is indicative of an energy level of the backscattered neutron radiation. The inspection device determines whether a potential anomaly is present in or around the wellbore, based at least in part on the respective amounts of backscattered radiation detected by the individually addressable detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying modeling uncertainties when combining multiple gravitational-wave detections from binary neutron star sources

Here, with the increasing sensitivity of gravitational-wave detectors, we expect to observe multiple binary neutron-star systems through gravitational waves in the near future. The combined analysis of these gravitational-wave signals offers the possibility to constrain the neutron-star radius and the equation of state of dense nuclear matter with unprecedented accuracy. However, it is crucial to ensure that uncertainties inherent in the gravitational-wave models will not lead to systematic biases when information from multiple detections is combined. To quantify waveform systematics, we perform an extensive simulation campaign of binary neutron-star sources and analyze them with a set of four different waveform models. For our analysis with 38 simulations, we find that statistical uncertainties in the neutron-star radius decrease to ± 250 m (2% at 90% credible interval) but that systematic differences between currently employed waveform models can be twice as large. Hence, it will be essential to ensure that systematic biases will not become dominant in inferences of the neutron-star equation of state when capitalizing on future developments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Detectability of subsolar mass neutron stars through a template bank search

Here, we study the detectability of gravitational-wave signals from subsolar-mass binary neutron star systems by the current generation of ground-based gravitational-wave detectors. We find that finite size effects from large tidal deformabilities of the neutron stars and lower merger frequencies can significantly impact the sensitivity of the detectors to these sources. By simulating a matched-filter based search using injected binary neutron star signals with tidal deformabilities derived from physically motivated equations of state, we calculate the reduction in sensitivity of the detectors. We conclude that the loss in sensitive volume can be as high as 78.4% for an equal mass binary system of chirp mass 0.17M ⊙ , in a search conducted using binary black hole template banks. We use this loss in sensitive volume, in combination with the results from the search for subsolar-mass binaries conducted on data collected by the LIGO-Virgo observatories during their first three observing runs, to obtain a conservative upper limit on the merger rate of subsolar-mass binary neutron stars. Since the discovery of a low-mass neutron star would provide new insight into formation mechanisms of neutron stars and further constrain the equation of state of dense nuclear matter, our result merits a dedicated search for subsolar-mass binary neutron star signals.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of active neutron interrogation of special nuclear materials using a high-intensity short-pulse-laser-driven neutron source

Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

6 Li-loaded liquid scintillators produced by direct dissolution of compounds in diisopropylnaphthalene (DIPN)

Here, this paper describes preparation of 6 Li-loaded liquid scintillators by methods involving direct dissolution of 6Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of 6 Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic and aliphatic 6 Li salts in DIPN can be easily achieved at 0.1%–0.3% by weight of atomic 6 Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of 6 Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient 6 Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.

36 MATERIALS SCIENCE↗

System and method for fissionable material detection with a short pulse neutron source

A system and method is disclosed for detecting fissionable materials. In one embodiment the system may incorporate a neutron pulse generator configured to generate multiple short pulses of neutrons, or a single pulse of sufficient intensity, in a vicinity of an object of interest. The source pulse of neutrons includes neutrons which each have a full width half maximum time duration of less than about 100 ns and a peak energy level no greater than about 20 MeV. A fast response detector is used which is able to detect single neutron events indicative of fission neutrons having been produced by the source pulse of neutrons interacting with fissionable material associated with the object of interest, and which arrive at the fast response detector within a predetermined time window immediately before arrival of the source neutron pulses.

Podpaly, Yuri↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗