Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Multiplication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Magnetic Bearing Pumps for Molten Salt Fusion Energy Devices

The Commonwealth Fusion Systems (CFS) ARC reactor will employ a novel liquid immersion blanket design that uses a molten lithium salt as both the tritium-breeding material and the vacuum vessel coolant. fluoride lithium beryllium (FLiBe) (a lithium fluoride–beryllium difluoride mixture) is currently the leading salt candidate. Its low-Z components provide good moderation, it has adequate heat transfer properties and low electrical conductivity, and it has good neutron multiplication properties, which further enhance tritium production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility Study for a Proposed Subcritical Assembly at Oak Ridge National Laboratory

Nuclear Criticality Safety (NCS) staff use the guidelines in the ANSI/ANS-8.26 standard to establish and maintain their training and qualifications. Section 7.4 of the standard requires NCS staff to participate in hands-on experiments meant to “…demonstrate how varying the properties of a fissionable material system can affect neutron multiplication.” This training is performed to ensure NCS and operations staff are aware of the risks involved with conducting operations with fissionable materials outside reactors. A new, inherently safe, subcritical assembly, to be housed at Oak Ridge National Laboratory (ORNL) is being considered to augment the current training capabilities of the US Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP), which conducts hands-on subcritical and critical experiments to support the training and qualifications of NCS staff. This paper reports the results of a feasibility study performed by ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Swarm Optimization Algorithm for Critical Experiment Design

Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization Algorithm for Criticality Experiment Design Using Whisper

Many criticality experiments performed to aid in nuclear data evaluation are designed to maximize the sensitivity of the system’s effective neutron multiplication factor to a certain nuclide reaction pair over an energy region of interest. This is typically done by evaluating possible designs in a transport code such as MCNP and selecting the one with the highest desired sensitivity. A designer has many tools to try to maximize this sensitivity such as different moderators, reflectors, fuels, and geometries. This balancing act of identifying a critical and maximally sensitive system become very computationally expensive as more variables are added and higher precisions are desired. In order to identify these optimal configurations more efficiently a Particle Swarm Optimization (PSO) algorithm coupled with MCNP has been developed by Los Alamos National Laboratory (LANL). This algorithm has been used to design two upcoming criticality experiments that will be performed at the National Criticality Experiments Research Center (NCERC), located at the Nevada National Security Site, and operated by LANL, the only general-purpose critical experiments laboratory in the United States. PSO uses a population (swarm) of candidate solutions (particles) on a search space of dimensions such as moderator and reflector thicknesses or enrichments and concentrations. These particles move around the search space from generation to generation according to simple rules. Eventually, the swarm converges on the configuration that is both critical and maximally sensitive to a piece of nuclear data. PSO is well suited for criticality experiments as the algorithm is agnostic to the underlying physics, meaning it is effective on many different experimental setups. This algorithm has been modified to maximize the nuclear data similarity coefficient between an application case and an experiment aimed at replicating the application case using WHISPER, a nuclear criticality safety analysis tool. This allows for the efficient design of critical experiments informed by nuclear data sensitives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of particle tracking methods for stochastic media

Random media emerge in several applications involving particle transport, encompassing e.g. photon propagation through Rayleigh-Taylor instabilities in fuel pellets for inertial confinement fusion, or neutron multiplication problems related to the assessment of re-criticality risk following severe accidents with fuel degradation. Reference calculations in such material configurations by means of Monte Carlo transport codes are particularly challenging, since high-density stochastic media might involve several hundreds of thousands of volumes and thus make particle tracking routines extremely cumbersome. In order to cope with these issues, two distinct strategies have been proposed so far: the use of neighbor maps, or the use of delta tracking. In this work we will compare these methods and illustrate their specific merits and drawbacks, as taken both alone and in combination with each other. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reference Fuel Development for Non-Aluminum Spent Nuclear Fuel Management

The Savannah River Site (SRS) L Area Facility provides for the safe receipt, storage, handling, and shipping of spent nuclear fuel (SNF) and has received more than 47,000 SNF assemblies since 1964. In order to consolidate receipt and storage analysis, L Area criticality safety has historically used several aluminum-clad “reference fuels” to establish bounding storage, handling, and cask loading limits and then applied a reactivity comparison approach to demonstrate that candidate fuels may be processed under the reference fuel limits. Currently, only aluminum-clad SNF from off-site research reactors are transferred on-site. The Accelerated Basin De-Inventory (ABD) program will begin the removal of bundled Non-Aluminum Spent Nuclear Fuel (NASNF) from the L Area disassembly basin for dissolution and disposition, which has driven the need for a non-aluminum reference fuel. This paper discusses the process and results of creating a new fictional homogenous NASNF highly enriched uranium reference fuel, “MITZ,” to be used in nuclear criticality safety evaluations for upcoming SNF disposition operations. Data demonstrating the relationship between neutron multiplication behavior and fuel spacing is generated for the new reference fuel MITZ as well as existing reference fuels representing several types of SNF assemblies.

Reference Fuel↗

Reference Fuel Development for Non-Aluminum Spent Nuclear Fuel Management

The Savannah River Site (SRS) L Area Facility provides for the safe receipt, storage, handling, and shipping of spent nuclear fuel (SNF) and has received more than 47,000 SNF assemblies since 1964. In order to consolidate receipt and storage analysis, L Area criticality safety has historically used several aluminum-clad “reference fuels” to establish bounding storage, handling, and cask loading limits and then applied a reactivity comparison approach to demonstrate that candidate fuels may be processed under the reference fuel limits. Currently, only aluminum-clad SNF from off-site research reactors are transferred on-site. The Accelerated Basin De-Inventory (ABD) program will begin the removal of bundled Non-Aluminum Spent Nuclear Fuel (NASNF) from the L Area disassembly basin for dissolution and disposition, which has driven the need for a non-aluminum reference fuel. This paper discusses the process and results of creating a new fictional homogenous NASNF highly enriched uranium reference fuel, “MITZ,” to be used in nuclear criticality safety evaluations for upcoming SNF disposition operations. Data demonstrating the relationship between neutron multiplication behavior and fuel spacing is generated for the new reference fuel MITZ as well as existing reference fuels representing several types of SNF assemblies.

Reference Fuel↗

Revisiting Source Convergence Diagnostics in the KENO Monte Carlo Neutron Transport Codes [Abstract]

Monte Carlo criticality transport codes, which rely on the power iteration procedure, are a fundamental tool for nuclear criticality safety practitioners in assessing the neutron multiplication factor (k eff ) for problems involving fissile material. In these calculations, ensuring the convergence of both the fission source distributions and the k eff estimate for accurate results is crucial. However, a converged k eff estimate does not necessarily mean the fission source distribution is also converged because the fission source and flux distribution may continue to evolve even after k eff convergence. Therefore, most Monte Carlo transport criticality codes now offer various diagnostic tests to assess fission source convergence in addition to the k eff convergence by analyzing the trends of these quantities over multiple generations.

AZURE↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Nuclear Data Libraries Sensitivity Studies for ORSA Using SCALE

Subcritical assemblies offer valuable training capabilities in nuclear criticality safety (NCS) for individuals handling fissile material. At Oak Ridge National Laboratory(ORNL), the Oak Ridge Subcritical Assembly (ORSA), a new experimental facility, is being established to provide hands-on training for the Nuclear Criticality Safety Program (NCSP).It is essential to accurately determine the neutron multiplication factor (keff) to ensure that ORSA remains subcritical and safe during operations. This study investigated the sensitivity of keff to variations across Evaluated Nuclear Data File (ENDF/B) libraries, consisting of ENDF/B-VII.1, ENDF/B-VIII.0, and ENDF/B-VIII.1. The analysis was conducted using the CSAS6 sequence in the SCALE-6.3 code system. Individual isotopes in the ORSA model were replaced one at a time with ENDF/B-VII.1 as the base library and changing to ENDF/B-VIII.0or ENDF/B-VIII.1. The results demonstrated that the changes in keffof the nuclides associated with the ORSA model were mostly within the uncertainty of the base model (~24 pcm), except for primary nuclides like Uranium-235and H-poly with few other nuclides. The relative delta keff values of Uranium-235 and H-poly, expressed in pcm, were +280 and -212 in ENDF/B-VIII.0 and +332 and -275 in ENDF/B-VIII.1, respectively, which were notable changes in reactivity. These results demonstrated that ORSA was largely insensitive to variations across these nuclear data libraries.

Hong, Evan [North Carolina State University]↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Integration and performance of large area picosecond photodetectors in the accelerator neutrino neutron interaction experiment

ANNIE, the Accelerator Neutrino Neutron Interaction Experiment, is a 26-ton Gadolinium-loaded water Cherenkov detector located at the Booster Neutrino beam line at Fermilab to mainly measure neutron multiplicity of neutrino interactions and test the performance of Large Area Picosecond Photodetectors (LAPPD). This thesis presents the integration of LAPPD at ANNIE and the preliminary performance analysis. LAPPDs achieved 2.48ns bunch structure resolution, even considering the time of flight and the intrinsic bunch width. The analysis also achieves better than 100ps intrinsic timing resolution, sub-mm position resolution for a single photoelectron, and cm-level resolution in conditional muon track reconstruction.

Feng, Yue [Iowa State U.] (ORCID:0000000332021351)↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗