Delayed Gamma-Ray Spectroscopy for Spent Nuclear Fuel Assay
High-energy, beta-delayed gamma-ray spectroscopy is investigated as a nondestructive assay technique for the determination of plutonium mass in spent nuclear fuel. This approach exploits the unique isotope-specific signatures contained in the delayed gamma-ray emission spectra detected following active interrogation with an external neutron source. A high fidelity modeling approach that couples radiation transport, analytical decay/depletion, and a newly developed gamma-ray emission source reconstruction code is described. Initially simulated and analyzed was a “one-pass” delayed gamma-ray assay that focused on the long-lived signatures. Also presented are the results of an independent study that investigated “pulsed mode” measurements to capture the more isotope-specific, short-lived signatures. The initial modeling results outlined in this paper suggest that delayed gamma-ray assay of spent nuclear fuel assemblies can be accomplished with a neutron generator of sufficient strength and currently available gamma-ray detectors.