Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Boron-10 Based Neutron Coincidence Counter for Safeguards

The shortage of 3He has triggered the search for effective alternative neutron detection technologies for national security applications, including international nuclear safeguards. Any alternative neutron detection technology must satisfy two basic criteria: it must meet a neutron detection efficiency requirement, and it must be insensitive to gamma-ray interference at a prescribed level while still meeting the neutron detection requirement. For nuclear safeguards, a system must perform measurements in the field with a prescribed precision in a specified time. This paper describes an effort to design, model and test an alternatives-based neutron coincidence counter for nuclear safeguards applications. The technology chosen for use in an alternatives-based uranium neutron coincidence collar was boron-lined proportional counters. Extensive modeling was performed of various system configurations and comparisons were made to measurements on a commercial prototype boron-10 based uranium neutron coincidence collar.

alternative neutron detectors↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

The detection of fast neutrons has important applications in several fields including solar, Geospace and planetary physics. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High-energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement is limited by short flight paths and small detector sizes characteristic of small satellite platforms. It is now possible to perform high-energy neutron measurements inside a large monolithic detector by imaging the recoil proton tracks, thus eliminating the need for a measure of the time-of-flight. The concept is based on a spectrometer assembled from numerous thin hydrogenous scintillating fibers that allow ionization track imaging. Fine grained readout is now possible with arrays of1-mm pitch silicon photomultipliers (SiPMs). The Solar Neutron TRACking (SONTRAC) instrument, equipped with scintillating fibers readout with SiPMs sensors, provides high-resolution, fine grained, imaging of fast (between 20-200 MeV) neutron scatters in a compact, low-power design ideal for small satellite(and aircraft) platforms. We discuss below applications of this technology and performance characteristics of the prototype SONTRAC instrument.

de Nolfo, Georgia A.↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of B-10 based detectors

Helium-3 gas-filled detectors have been used in nuclear safeguards applications, in homeland security neutron detection modules and in research for over 30 years. With the current shortage of {sup 3}He gas, GE's Reuter-Stokes business developed a {sup 10}B lined proportional counter and a {sup 10}B hybrid detector, in which a small amount of {sup 3}He is added to a 10B detector to enhance the neutron sensitivity. In 2010, GE's Reuter-Stokes successfully developed a commercial alternative to 3He gas-filled detectors for homeland security neutron detection modules based on 10B lined proportional counters. We will present the concept behind the {sup 10}B neutron detection modules, as drop-in replacement to existing 3He neutron detection modules deployed, and the timeline and development needed to get a fully commercial application. To ensure the highest quality, each {sup 10}B neutron detection unit is put through a series of tests: temperature cycles from -40 deg. C to +55 deg. C, vibration testing at levels up to 2.5 g from 10 Hz to 50 Hz in every direction, neutron sensitivity reaching up to 4.5 cps/(ng {sup 252}CF at 2 m), and gamma insensitivity with field reaching 1 Sv/hr. In 2013, GE's Reuter-Stokes developed the B10Plus+{sup R} detector, in which a small amount of {sup 3}He is added to a {sup 10}B lined proportional counter. Depending on the amount of {sup 3}He added, the B10Plus+{sup R} can more than double the neutron sensitivity compared to a {sup 10}B lined proportional counter. {sup 10}B lined proportional counters and B10Plus+{sup R} have excellent gamma rejection and excellent performance even at very high neutron flux. The gamma rejection and high neutron flux performance of these detectors are comparable, if not better, than traditional {sup 3}He proportional counters. GE's Reuter-Stokes business modelled, designed, built and tested prototype coincidence counters using the {sup 10}B lined detectors and the {sup 10}B hybrid detectors. We will present these systems and their applications for non-destructive assay. We will also show other examples of applications where {sup 10}B lined proportional counters and B10Plus+{sup R} detectors can be used. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and Photon Background Measurements at the Spallation Neutron Source Facility - Paper 67

The Spallation Neutron Source facility is a short-pulsed spallation source for condensed matter research using slow neutron scattering. Neutron beams with useful energies ranging from 0.1 meV to 10 eV are brought from a target-moderator-reflector assembly down neutron beamlines to scatter from a variety of materials under study. As of early 2014, SNS routinely provides 1.4 MW (time-averaged) proton power at around 940 MeV to a mercury spallation target at 60 Hz in sub-microsecond pulses. In nearly all cases, the pulsed nature of the neutron source is used, via time-of-flight techniques, to precisely identify the energy of each neutron detected. These neutrons are frequently of such low energy, and consequent slow velocity, that they are not detected until several additional accelerator pulses have taken place. A time-dependent background feature, commonly called the 'prompt pulse,' can contaminate the recorded data. This prompt pulse arises in part from fast and high-energy neutrons and photons produced during the various source reactions, and appears at the same apparent time as the proton pulse striking the target (that is, with negligible time-of-flight delay), often obscuring the data of interest in the individual experiment. We describe here measurements of the fast and high-energy neutron and photon background around the SNS neutron scattering instruments appearing in time with the SNS accelerator pulse structure. Our measurements to date indicate that the liquid scintillator array we have deployed can satisfactorily function in the SNS environment and provide neutron-photon discriminated time/energy spectra of background sources contribution to observed, problematic SNS scattering instrument backgrounds. We will continue measurements and analysis to provide unfolded neutron energy spectra, and through longitudinal studies correlate observed changes in those spectra to external changes at SNS. (authors)

43 PARTICLE ACCELERATORS↗

Hexagonal boron nitride neutron detectors with high detection efficiencies

Here, neutron detectors fabricated from 10B enriched hexagonal boron nitride (h- 10 BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm 2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer on both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h- 10 BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6 LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Above-ground Antineutrino Detection for Nuclear Reactor Monitoring

Antineutrino monitoring of nuclear reactors has been demonstrated many times, however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detector media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6 LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of lithium-6. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron’s annihilation gammas, which are absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe this technology will ultimately be applicable to potential safeguards scenarios such as those recently described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First (p,n) reaction measurement in inverse kinematics with SECAR

Nucleosynthesis in the νp-process occurs in regions of slightly proton-rich nuclei in the neutrino-driven wind of core-collapse supernovae. The process proceeds via a sequence of (p,γ) and (n,p) reactions, and depending on the conditions, may produce elements between Ni and Sn. Recent studies show that a few key (n,p) reactions regulate the efficiency of the neutrino-p process (νp-process). We performed a study of one of such (n,p) reactions via the measurement of the reverse (p,n) in inverse kinematics with SECAR at NSCL/FRIB.Such proton-induced reaction measurements are particularly challenging, as the recoils and the unreacted projectiles have nearly identical masses. An appropriate separation level can be achieved with SECAR, and along with the incoincidence detection of neutrons these measurements become attainable. The preparation of the SECAR system for accommodating its first (p,n) reaction measurement, including the development of alternative ion beam optics, and the setup of the in-coincidence neutron detection, along with discussion on preliminary results from the p(58Fe,n)58Co reaction measurement are presented and discussed.

Tsintari, P↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.

T A Livengood↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

Past 3He shortages led to investigations into replacement options for neutron detectors in systems that previously used 3He-based technologies. The goal of this research was to investigate the feasibility of a full-scale lithium fluoride with silver activated zinc sulfide (LiF/ZnS) based neutron multiplicity counter. The LiF/ZnS based neutron multiplicity counter (LiNMC) was developed based on an iterative process between modeling and experimental measurements. Each active region of the LiNMC contains five sheets of LiF/ZnS sandwiched between six sheets of wavelength shifting plastic to form neutron detection stacks. The wavelength shifted scintillation light was collected by photomultiplier tubes located on each end of the stacks. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high density polyethylene blocks in the corners to reflect high energy neutrons and capture low energy neutrons. Preliminary calibration with a 252Cf neutron source showed that the LiNMC was able to achieve 36% neutron detection efficiency (ε) and an 11.7 μs neutron die-away time (τ) for a doubles Figure-of-merit (ε2/ τ) of 109. This is the highest doubles Figure-of-merit performance measured to-date for a 3He-free neutron multiplicity counter system. By the end of this project, the LiNMC’s basic components were integrated into a single laboratory scale system capable of proof-of-concept measurements.

3He-free↗

Fissile material detection using neutron time-correlations from photofission

The detection of special nuclear materials (SNM) in commercial cargoes is a major objective in the field of nuclear security. In this work we investigate the use of two-neutron time-correlations from photo-fission using the Prompt Neutrons from Photofission (PNPF) detectors in Passport Systems Inc.’s (PSI) Shielded Nuclear Alarm Resolution (SNAR) platform for the purpose of detecting ~5 kg quantities of fissionable materials in seconds. The goal of this effort was to extend the secondary scan mode of this system to differentiate fissile materials, such as highly enriched uranium, from fissionable materials, such as low enriched and depleted uranium (LEU and DU). Experiments were performed using a variety of material samples, and data were analyzed using the variance-over-mean technique referred to as Y 2F or Feynman-α. Results were compared to computational models to improve our ability to predict system performance for distinguishing fissile materials. Simulations were then combined with empirical formulas to generate receiver operating characteristics (ROC) curves for a variety of shielding scenarios. We show that a 10 second screening with a 200 μA 9 MeV X-ray beam is sufficient to differentiate kilogram quantities of HEU from DU in various shielding scenarios in a standard cargo container.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Crystal growth of LiIn 1–x Ga x Se 2 crystals

Lithium containing chalcogenide single crystals have become very promising materials for photonics and radiation detection. Detection applications include nuclear nonproliferation, neutron science, and stellar investigations for the search of life. Synthesis and single crystal growth methods for lithium containing chalcogenide, specifically LiIn 1-x Ga x Se 2 , single crystals are discussed. This study elucidates the possibility of improving neutron detection by reducing the indium capture contribution; with the incorporation of the lithium-6 isotope, gallium substitution may overcome the neutron detection efficiency limitation of 6 LiInSe 2 due to appreciable neutron capture by the indium-115 isotope. As a figure of merit, the ternary parent compounds 6 LiInSe 2 and 6 LiGaSe 2 were included in this study. Quality crystals can be obtained utilizing the vertical Bridgman method to produce quaternary compounds with tunable optical properties. Here, quaternary crystals of varying quality depending on the gallium concentration, approximately 5 x 5 x 2 mm 3 or larger in volume, were harvested, analyzed and revealed tunable absorption characteristics between 2.8-3.4 eV.

36 MATERIALS SCIENCE↗