At least 181 records · Page 10

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational characterization and experimental validation of the thermal neutron source for neutron capture therapy research at the University of Missouri

Parameter studies, design calculations and neutronic performance measurements have been completed for a new thermal neutron beamline constructed for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. Validation protocols based on neutron activation spectrometry measurements and rigorous least-square adjustment techniques show that the beam produces a neutron spectrum that has the anticipated level of thermal neutron flux and a somewhat higher than expected, but radio-biologically insignificant, epithermal neutron flux component. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

Neutron time-of-flight diagnostics have long been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d + t → n + α (DT) and d + d → n + {sup 3}He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (T{sub ion}) and cold fuel areal density. We report on novel methodologies used to determine neutron yield, apparent T{sub ion}, and DSR. These methods invoke a single temperature, static fluid model to describe the neutron peaks from DD and DT reactions and a spline description of the DT spectrum to determine the DSR. Both measurements are performed using a forward modeling technique that includes corrections for line-of-sight attenuation and impulse response of the detection system. These methods produce typical uncertainties for DT T{sub ion} of 250 eV, 7% for DSR, and 9% for the DT neutron yield. For the DD values, the uncertainties are 290 eV for T{sub ion} and 10% for the neutron yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fission Product Yields from 232Th, 238U, and 235U Using 14 MeV Neutrons

Neutron-induced fission yield studies using deuterium-tritium fusion-produced 14 MeV neutrons have not yet directly measured fission yields from fission products with half-lives on the order of seconds (far from the line of nuclear stability). Fundamental data of this nature are important for improving and validating the current models of the nuclear fission process. Cyclic neutron activation analysis (CNAA) was performed on three actinide targets–thorium-oxide, depleted uranium metal, and highly enriched uranium metal–at the University of Michigan's Neutron Science Laboratory (UM-NSL) using a pneumatic system and Thermo-Scientific D711 accelerator-based fusion neutron generator. This was done to measure the fission yields of short-lived fission products and to examine the differences between the delayed fission product signatures of the three actinides. The measured data were compared against previously published results for 89Kr, -90, and -92 and 138Xe, -139, and -140. The average percent deviation of the measured values from the Evaluated Nuclear Data Files VII.1 (ENDF/B-VII.1) for thorium, depleted-uranium, and highly-enriched uranium were -10.2%, 4.5%, and -12.9%, respectively. In addition to the measurements of the six known fission products, 23 new fission yield measurements from 84As to 146La are presented.

Pierson, Bruce D.↗

Neutron imaging with the short-pulse laser driven neutron source at the TRIDENT Laser Facility

Emerging approaches to short-pulse laser-driven neutron production offer a possible gateway to compact, low cost, and intense broad spectrum sources for a wide variety of applications. They are based on energetic ions, driven by an intense short-pulse laser, interacting with a converter material to produce neutrons via breakup and nuclear reactions. Recent experiments performed with the high-contrast laser at the Trident laser facility of Los Alamos National Laboratory have demonstrated a laser-driven ion acceleration mechanism operating in the regime of relativistic transparency, featuring a volumetric laser-plasma interaction. This mechanism is distinct from previously studied ones that accelerate ions at the laser-target surface. The Trident experiments produced an intense beam of deuterons with an energy distribution extending above 100 MeV. This deuteron beam, when directed at a beryllium converter, produces a forward-directed neutron beam with ~5x10 9 n/sr, in a single laser shot, primarily due to deuteron breakup. The neutron beam has a pulse duration on the order of a few nanoseconds with an energy distribution extending from a few hundreds of keV to almost 80 MeV. For the experiments on neutron-source spot-size measurements, our gated neutron imager was setup to select neutrons in the energy range of 2.5 to 35 MeV. The spot size of neutron emission at the converter was measured by two different imaging techniques, using a knife-edge and a penumbral aperture, in two different experimental campaigns. The neutron-source spot size is measured ~1 mm for both experiments. The measurements and analysis reported here give a spatial characterization for this type of neutron source for the first time. In addition, the forward modeling performed provides an empirical estimate of the spatial characteristics of the deuteron ion-beam. Finally, these experimental observations, taken together, provide essential yet unique data to benchmark and verify theoretical work into the basic acceleration mechanism, which remains an ongoing challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed neutron detection with an integrated differential die-away and delayed neutron instrument

The Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy (DOE) has funded a multilab/university collaboration to quantify the plutonium (Pu) mass and detect the diversion of pins from spent nuclear fuel. The first two years of this NGSI effort was focused on quantifying the capability of a range of nondestructive assay (NDA) techniques with Monte Carlo (MCNPX) modeling and the second current phase involves measuring Spent Fuel. One of the techniques of interest in this paper involves measuring delayed neutrons. A delayed neutron instrument using 36 fission chambers and a 14 MeV neutron generator so called DT generator (Deuterium + Tritium) surrounding the fuel was previously studied as part of the NGSI effort. This paper will quantify the capability of a standalone delayed neutron instrument using 4 {sup 3}He gas filled tubes and a DT generator with significant spectrum tailoring, located far from the fuel. So that future research can assess how well a delayed neutron instrument will function as part of an integrated NDA system. A new design is going to be used to respond to the need of the techniques. This design has been modeled for a water media and is currently being optimized for borated water and air media as part of ongoing research. This new design was selected in order to minimize the fission of {sup 238}U, to use a more realistic neutron generator design in the model, to reduce cost and facilitate the integration of a delayed neutron (DN) with a differential die-away (DDA) instrument. Since this paper will focus on delayed neutron detection, the goal is to quantify the signal from {sup 235}U, {sup 239}Pu and {sup 241}Pu, which are the isotopes present in Spent Fuel that respond significantly to a neutron interrogation. This report will quantify the capability of this new delayed neutron design to measure the combined mass of {sup 235}U, {sup 239}Pu and {sup 241}Pu for 16 of the 64 assemblies of the NGSI Spent Fuel library in one of the three media, water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-level measuring techniques for neutrons: High accuracy neutron source strength determination and fluence rate measurement at an underground laboratory

We report on measuring techniques for neutrons that have been developed at the Physikalisch-Technische Bundesanstalt (PTB), the German National Metrology Institute. PTB has characterized radioactive sources used in the BOREXINO and XENON100 experiments. For the BOREXINO experiment, a {sup 228}Th gamma radiation source was required which would not emit more than 10 neutrons per second. The determination of the neutron emission rate of this specially designed {sup 228}Th source was challenging due to the low neutron emission rate and because the ratio of neutron to gamma radiation was expected to be extremely low, of the order of 10{sup −6}. For the XENON100 detector, PTB carried out a high accuracy measurement of the neutron emission rate of an AmBe source. PTB has also done measurements in underground laboratories. A two month measurement campaign with a set of {sup 3}He-filled proportional counters was carried out in PTB's former UDO underground laboratory at the Asse salt mine. The aim of the campaign was to determine the intrinsic background of detectors, which is needed for the analysis of data taken in lowintensity neutron fields. At a later time, PTB did a preliminary measurement of the neutron fluence rate at the underground laboratory Felsenkeller operated by VKTA. By taking into account data from UDO, Felsenkeller, and detector calibrations made at the PTB facility, it was possible to estimate the neutron fluence rate at the Felsenkeller underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing neutron-skin thickness with free spectator neutrons in ultracentral high-energy isobaric collisions

We show that the yield ratio of free spectator neutrons produced in high-energy 96 Zr+ 96 Zr to 96 Ru+ 96 Ru collisions is a clean probe of the neutron-skin thickness of colliding nuclei and the slope parameter L of the symmetry energy. The idea is demonstrated based on the proton and neutron density distributions via a state-of-the-art Skyrme-Hartree-Fock-Bogolyubov calculation. Among spectator nucleons given by the Glauber model, free spectator neutrons include those from direct production that survive from clusterization as well as those from deexcitation of heavy clusters described by the popular GEMINI model. More free neutrons are produced in collisions of 96 Zr nucleus due to its larger neutron skin, compared to those produced in collisions of 96 Ru nucleus with a smaller neutron skin. The difference of the free spectator neutron yield is further increased with the increasing difference of the neutron-skin thickness between 96 Zr and 96 Ru with a larger L value, and the increase in ultracentral collisions is particularly insensitive to model details and experimental uncertainties. Since the production of free spectator neutrons is not affected by the complicated dynamics in the mid-rapidity region, the ratio of their multiplicities in ultracentral isobaric collisions is a robust observable for constraining the neutron skin and L value.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing high-momentum protons and neutrons in neutron-rich nuclei

The atomic nucleus is one of the densest and most complex quantum-mechanical systems in nature. Nuclei account for nearly all the mass of the visible Universe. The properties of individual nucleons (protons and neutrons) in nuclei can be probed by scattering a high-energy particle from the nucleus and detecting this particle after it scatters, often also detecting an additional knocked-out proton. Analysis of electron- and proton-scattering experiments suggests that some nucleons in nuclei form close-proximity neutron–proton pairs with high nucleon momentum, greater than the nuclear Fermi momentum. However, how excess neutrons in neutron-rich nuclei form such close-proximity pairs remains unclear. In this study we measure protons and, for the first time, neutrons knocked out of medium-to-heavy nuclei by high-energy electrons and show that the fraction of high-momentum protons increases markedly with the neutron excess in the nucleus, whereas the fraction of high-momentum neutrons decreases slightly. This effect is surprising because in the classical nuclear shell model, protons and neutrons obey Fermi statistics, have little correlation and mostly fill independent energy shells. These high-momentum nucleons in neutron-rich nuclei are important for understanding nuclear parton distribution functions (the partial momentum distribution of the constituents of the nucleon) and changes in the quark distributions of nucleons bound in nuclei (the EMC effect). They are also relevant for the interpretation of neutrino-oscillation measurements and understanding of neutron-rich systems such as neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments with neutron induced neutron emission from U-235, Pu-239, and graphite

A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress in the Measurement of Prompt Neutron Output in Neutron-Induced Fission of 239 Pu: The Chi-Nu Project

Knowledge of the prompt neutron output from neutron-induced fission of 239 Pu is essential to nuclear defense and energy applications. Because the experimental data base is inadequate to constrain models of the spectrum of neutrons from fission, we have embarked on a multi-year program of new measurements of the prompt fission neutron spectrum as a function of the energy of the incident neutron that induces the fission. This is a joint LANL-LLNL project with participation by four university groups in advanced detector development. In the past year much progress has been achieved. The building housing the experiment has been completed and the flight paths including one for this experiment are now constructed. A parallel-plate avalanche counter (PPAC) containing 235 U is installed and working in the beam line. Neutron detectors for both low (<1 MeV) and high (> 0.5 MeV) neutrons have been assembled. The data acquisition system based on waveform digitizers has undergone extensive development and now can handle 10 PPAC channels and 10 neutron detectors simultaneously. In addition, a detector test station centered on a 252 Cf spontaneous fission chamber has been commissioned so that we can characterize our neutron detectors in a well understood experimental environment. Analysis of experiments at this facility has helped us understand the performance of several types of neutron detectors. In addition, the analysis work uncovered that the “standard” 252 Cf fission neutron spectrum in MCNPX disagrees significantly from that presently accepted by the international standards community. One year ago we submitted a report (LA-UR-11-05576) on the accuracies that could be reached under certain assumptions. Several sources of possible systematic uncertainties were identified, and procedures to control these uncertainties were suggested. This report is included as an appendix to this report. One element missing from these estimates was the contribution of backgrounds. It could not be quantified because, at that time, the building and flight path for the experiments had not been constructed. We now have made some measurements of the background and can now add this component to the accuracy projections. This report summarizes the progress in the past year. It also discusses measurements reported in the literature and some factors that should be considered when using these data to optimize parameters in nuclear model codes used in constructing evaluated nuclear data bases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

U.S. Fusion D-Li Neutron Irradiation Facility: Fusion Prototypic Neutron Source (FPNS) Technology Study

A primary engineering challenge for the realization of fusion energy involves the development of high-performance structural and plasma-facing materials with dimensional stability and resistance to neutron degradation of mechanical properties. The harsh fusion environment, including high levels of helium production and other transmutation products along with high operating temperatures, poses an extreme challenge for materials. Identifying materials that can withstand these conditions is a high priority for fusion energy research. Critical to resolving this gap in scientific understanding is developing a neutron source facility with the ability to mimic the extreme conditions in a fusion reactor. Working with the Department of Energy (DOE) Office of Fusion Energy Sciences (FES), Oak Ridge National Laboratory (ORNL) and the Virtual Laboratory for Technology (VLT) organized a workshop to discuss the need for a Fusion Prototypic Neutron Source (FPNS). [1] While there are a variety of uses for FPNS neutrons, the main driver of US interest is expanding the scientific understanding of materials degradation in the deuterium-tritium (D-T) fusion environment. FPNS will help build the scientific foundation required to enable design of a next step fusion device. Using specifications from previous projects as a guide, key parameters were agreed upon for a near term, moderate cost US facility that would be complementary to the more extensive plans of the International Fusion Materials Irradiation Facility (IFMIF). Types of facilities that could potentially meet those criteria were identified. A scoping study for three technologies was initiated to answer three critical questions: 1) Can the concept meet the key parameters, 2) What is the estimated cost, and 3) What is the estimated schedule. One approach selected for the scoping study is a D-Li stripping source similar to the design of the IFMIF but at a lower beam power and atomic displacement rate for cost and schedule reasons. The purpose of this report is to document the results of the D-Li stripping source option study, providing answers to the three questions. The approach to generating a fusion prototypic neutron source using a deuteron beam incident on a flowing lithium target has been studied for more than 40 years. As a result of the research and development recently executed primarily in Europe and Japan, the ability of this approach to meet key parameters (damage parameters, irradiation volume) outlined in the US workshop for a near-term, moderate cost fusion prototypic neutron source facility is not in doubt. The main question that must be answered is the cost of such a facility. As a result, a strong focus was placed on understanding alternatives for developing the facility and their relative costs. The project was broken into four components for the cost estimate: the ion source, accelerator, lithium target system, and conventional facilities. The cost of the accelerator is an important cost driver for the D-Li stripping concept. To fully understand the range of the accelerator cost, multiple alternatives were considered including normal conducting and superconducting linacs and the frequency of the radiofrequency quadrupole. Multiple previous design studies dating from 1989 through 2017 were examined (costs were escalated to 2019 dollars) and compared. After analysis, two options were selected for costing, one superconducting and one room temperature. We found similar project costs for the two accelerator options, on the order of $100M including design and project management but excluding contingency. Including everything except the conventional facilities, the estimate for the neutron source facility is estimated to be $220M without contingency. Additional significant costs for the facility are the conventional costs arising from the need to construct buildings for the accelerator and target facilities, bringing electrical power to the site including a new substation, and removing the heat from the facility using heat exchangers. While ORNL would oversee this work, much of the effort would be executed by contractors. Estimates for this effort was based on similar projects that are currently being executed at ORNL or were executed at ORNL in the recent past. The estimate for conventional facilities for the neutron facility is $173M without contingency, bringing the total project cost to $393M without contingency. With a 50% contingency, the estimated cost is $589M. The estimate range was established using guidance from the Association for the Advancement of Cost Engineering (AACE). Specifically, guidance from recommended practice 17R-97 provides insight on the expected accuracy range of estimates based on the degree of project definition and the position of the project in the stage-gate process or maturity timeline. An AACE Class 5 type estimate is appropriate for concept screening. The expected accuracy range includes a low end of -50% to -20% and a high end of +30% to +100% around the estimated cost. For the D-Li stripping neutron source, a -20% to +100% cost range was applied for a recommended cost range of $471M to $1,179M. Less emphasis was placed on determining the project schedule due to the fact that the project costs were large and may eliminate this option from consideration. The development of the accelerator facility may require on the order of five years without contingency. A more realistic schedule with contingency may be seven years. However, this estimate should be scrutinized in a preconceptual design activity if a more realistic estimate is needed. Finally, one lesson learned in this process is that the requirements for a near-term, moderate cost facility drives the alternative selection toward existing facilities and infrastructure. The D-Li stripping neutron source option requires a green field site due to the lack of existing buildings and infrastructure that can be reused for this effort. As a result, the conventional facilities costs are a significant fraction of the total facility cost. Other neutron source options where buildings, electrical power, and cooling infrastructure already exist may be able to meet the requirements for a near term, moderate cost facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron rich matter in the laboratory and in the heavens after GW170817

The historic observations of the neutron star merger GW170817 advanced our understanding of r-process nucleosynthesis and the equation of state (EOS) of neutron rich matter. Simple neutrino physics suggests that supernovae are not the site of the main r-process. Instead, the very red color of the kilonova associated with GW170817 shows that neutron star (NS) mergers are an important r-process site. We now need to measure the masses and beta decay half-lives of very neutron rich heavy nuclei so that we can more accurately predict the abundances of heavy elements that are produced. This can be done with new radioactive beam accelerators such as the Facility for Rare Isotope Beams (FRIB). GW170817 provided information on the deformability of NS and the equation of state of dense matter. The PREX II experiment will measure the neutron skin of {sup 208}Pb and help constrain the low density EOS. As the sensitivity of gravitational wave detectors improve, we expect to observe many more events. We look forward to exciting advances and surprises!.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Dependence of Fission Product Yields from {sup 235}U, {sup 238}U and {sup 239}Pu for Incident Neutron Energies Between 0.5 and 14.8 MeV

Fission Product Yields (FPY) have historically been one of the most observable features of the fission process. They are known to have strong variations that are dependent on the fissioning species, the excitation energy, and the angular momentum of the compound system. However, consistent and systematic studies of the variation of these FPY with energy have proved challenging. This is caused primarily by the nature of the experiments that have traditionally relied on radiochemical procedures to isolate specific fission products. Although radiochemical procedures exist that can isolate all products, each element presents specific challenges and introduces varying degrees of systematic errors that can make inter-comparison of FPY uncertain. Although of high importance in fields such as nuclear forensics and Stockpile Stewardship, accurate information about the energy dependence of neutron induced FPY are sparse, due primarily to the lack of suitable monoenergetic neutron sources. There is a clear need for improved data, and to address this issue, a collaboration was formed between Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL) and the Triangle Universities Nuclear Laboratory (TUNL) to measure the energy dependence of FPY for {sup 235}U, {sup 238}U and {sup 239}Pu. The measurements have been performed at TUNL, using a 10 MV Tandem Van de Graaff accelerator to produce monoenergetic neutrons at energies between 0.6 MeV to 14.8 MeV through a variety of reactions. The measurements have utilized a dual-fission chamber, with thin (10-100 μg/cm2) reference foils of similar material to a thick (100-400 mg) activation target held in the center between the chambers. This method allows for the accurate determination of the number of fissions that occurred in the thick target without requiring knowledge of the fission cross section or neutron fluence on target. Following activation, the thick target was removed from the dual-fission chamber and gamma-ray counted using shielded HPGe detectors for a period of 1-2 months to determine the yield of various fission products. To the extent possible all irradiation and counting procedures were kept the same to minimize sources of systematic errors. FPY have been determined at incident neutron energies of 0.6, 1.4, 2.4, 3.5, 4.6, 5.5, 8.9 and 14.8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron activation diagnostics at the National Ignition Facility (invited)

Neutron yields are measured at the National Ignition Facility (NIF) by an extensive suite of neutron activation diagnostics. Neutrons interact with materials whose reaction cross sections threshold just below the fusion neutron production energy, providing an accurate measure of primary unscattered neutrons without contribution from lower-energy scattered neutrons. Indium samples are mounted on diagnostic instrument manipulators in the NIF target chamber, 25-50 cm from the source, to measure 2.45 MeV deuterium-deuterium fusion neutrons through the {sup 115}In(n,n'){sup 115m} In reaction. Outside the chamber, zirconium and copper are used to measure 14 MeV deuterium-tritium fusion neutrons via {sup 90}Zr(n,2n), {sup 63}Cu(n,2n), and {sup 65}Cu(n,2n) reactions. An array of 16 zirconium samples are located on port covers around the chamber to measure relative yield anisotropies, providing a global map of fuel areal density variation. Neutron yields are routinely measured with activation to an accuracy of 7% and are in excellent agreement both with each other and with neutron time-of-flight and magnetic recoil spectrometer measurements. Relative areal density anisotropies can be measured to a precision of less than 3%. These measurements reveal apparent bulk fuel velocities as high as 200 km/s in addition to large areal density variations between the pole and equator of the compressed fuel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗