Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NbS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Results from the Balloon Ozone Intercomparison Campaign (BOIC)

In the Balloon Ozone Intercomparison Campaign (BOIC), several in situ UV absorption photometers, two solar UV absorption photometers, electrochemical sondes, and a mass spectrometer were intercompared in three flight missions. Concurrent data from Umkehr and satellite observations are also intercompared. The National Bureau of Standards provided a 'standard' ozone source for intercomparing the in situ instruments and ground pressure. Preliminary findings indicate that the standard deviation of the sensitivities among 17 instruments against the NBS reference was about 11 percent. These differences appear in flight at the lower levels and change at higher altitudes, indicating height-dependent errors. The difference among five in-situ UV photometers flown together ranged by plus or minus 8 percent during ascent to about 41 km. During float at 42 km, the difference nearly doubled. During descent, the difference decreased to about 4 percent, which is much closer to the expected accuracy of these instruments. Results from UV solar radiometers have been systematically higher than those from UV photometers by 15 to 20 percent - a very important disagreement that needs to be resolved.

Hilsenrath, E.↗

Air- and oxygen-broadening coefficients for the O2 rotational line at 60.46/cm

Using an NBS laser-based tunable far-infrared spectrometer, the air- and oxygen-broadening coefficients were measured for the J = 10 - 10, N = 11 - 9 O2 rotational transition at 60.46/cm (1.812 THz). The air-broadening coefficient is 5.04 + or - 0.38 x 10 to the -7th/cm/Pa (0.0511 + or - 0.0039/cm/atm) (HWHM) at 245 + or - 6 K; the oxygen-broadening coefficient is 4.92 + or - 0.47 x 10 to the -7th/cm/Pa (0.0499 + or - 0.0048/cm/atm) (HWHM) at 259 + or -2 K. These direct experimental measurements of the air-broadening coefficient should improve the accuracy of retrieval calculations for far-infrared stratospheric balloon experiments which use O2 rotational lines to calibrate the viewing geometry.

Jennings, D. A.↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Radiometric calibrations of portable sources in the vacuum ultraviolet

The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.

Klose, Jules Z.↗

Theoretical studies of the monoxides and monosulfides of Y, Zr, and Nb

Modified-CPF and CASSCF/multireference-CI theoretical calculations are presented for the ground and low-lying states of YO and YS, ZrO and ZS, and NbO and NbS. The techniques employed are explained, and the calculated spectroscopic constants are presented in extensive tables. Good agreement is found with published experimental data on the oxides, and it is inferred that the sulfide results are accurate as well. Particular attention is given to the high-lying quartet manifold of states in YO and the (1) 3Pi-a3Delta transition of ZrS (possibly the source of the IR Keenan bands seen in S-star spectra).

Langhoff, Stephen R.↗

Radiance standards

Two radiometric calibration sources that are utilized by various groups are maintained and operated. One source is a 6-ft diameter sphere and the other a 4-ft diameter hemisphere. Both are internally coated with multiple layers of barium sulfate and house an array of 12 tungsten filament-quartz iodine lamps that provide a uniform diffuse target of radiance traceable to NBS. The lamps are baffled and arranged so that they are not part of the scene during calibrations. Both systems have a 10-inch viewing aperture. The hemisphere is somewhat more versatile in that the aperture can be changed and the system is movable so calibrations can be done at other sites. Together, these systems have supported numerous GSFC projects and missions during this review period. They are listed.

Lester, D. L.↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

Laboratory calibration of field reflectance panels

A method used for calibrating field reflectance panels in the visible and shortwave infrared wavelength range is described. The directional reflectance factor of painted barium sulfate (BaSO4) panels is determined. The reference for this method is the hemispherical reflectance of pressed polytetrafluoroethylene (halon) powder prepared according to National Bureau of Standards (NBS) directions. The panels and a radiometer are mounted on rotation stages to measure the reflectance factor at different incidence and view angles. The sensor can be any laboratory or field filter radiometer small enough to mount on the apparatus. The method is used to measure the reflectance factors of halon and BaSO4 panels between 0.45 and 0.85 micrometers. These reflectance factors are compared to those measured by a field apparatus. The results agree to within 0.013 in reflectance at incidence angles between 15 and 75 degrees.

Biggar, S. F.↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

NASA/GSFC split-rail parallel gripper

The current state of development of the NASA/GSFC (Goddard Space Flight Center) Split-Rail Parallel Gripper (SRPG) is described. The SPRG has been shown to be a high performance gripper for industrial robots. It has a precise wide throw and at the same time, it is light, simple, compact, rugged, and jam-proof against side loads. Originated at the National Bureau of Standards (NBS), this gripper is undergoing further development at NASA/GSFC in pursuit of two goals: as a potential gripper for robots in space and as the basis for sensory-interactive industrial gripper as part of NASA's technology utilization program. The gripper design features, its principles of operation and how it is constructed are described. Test results are included.

Vranish, John M.↗

Program Supplies Properties Of Parahydrogen

National Bureau of Standards Parahydrogen Properties Database (NBS+_PH2) computer program developed to provide selected thermal and transport properties of parahydrogen matching 1981 parahydrogen data of National Bureau of Standards (now called National Institute of Standards and Technology). Created to be linked with propulsion-simulation programs, which require mathematical model of parahydrogen covering wide range of pressures and temperatures. Provides data on parahydrogen for pressures from 10 kPa to 16 MPa and temperatures from 20 to 104 K. Provides following properties: density, thermal conductivity, viscosity, Prandtl number, enthalpy, specific heat, and speed of sound. Written in FORTRAN 77.

Walton, J. T.↗

Comparison of GPS and GLONASS common-view time transfers

It was already shown than even with a simple daily averaging of GLONASS data at each site, continental GLONASS time transfer can be achieved at a level of several tens of nanoseconds. A further step is to carry out observations of GLONASS satellites by the common-view method. A comparison of GPS and GLONASS common-view time transfers between Russia and Western Europe are reported. At each site, a GPS receiver and a GLONASS receiver are connected to the same atomic clock. Both GPS receivers are of NBS type and the GLONASS receivers are of type A-724. As GPS common-view time transfer between Sevres and Mendeleevo is accomplished at a level of a few nanoseconds in precision, it gives an excellent reference with which to evaluate the performance of GLONASS common-view time transfer.

Lewandowski, W.↗

Simulation of cryogenic turbopump annular seals

San Andres employed the NBS software package MIPROPS to account for density's dependence on pressure in the simulation of liquid annular seals. His example on a LH2 seal showed a significant change in the mass coefficient compared to a constant density model. San Andres, Yang, and Childs extended this analysis by including the pressure and temperature dependence of density, specific heat, viscosity, volumetric expansion, and thermal conductivity in a coupled solution of the energy, momentum, and continuity equations. Their example showed very significant changes in stiffness and inertia for a high speed (38,000 rpm), large L/D ratio (0.5) LOX seal, as compared to their constant temperature results. The current research rederived the San Andres-Yang-Childs (SYC) analysis and extended it to include not only the Moody friction model of SYC but also the Hir's friction model. The derivation begins with obtaining the local differential equations of continuity, momentum, and energy conservation in the seal. These equations are averaged across the film thickness to obtain the resulting 'bulk flow' differential equations. Shear stress and convective heat loss through the stator (seal) and rotor are related to the Moody and Hir's friction factor model. The Holman analogy is employed to relate heat conduction in or out of the fluid film's boundary layer to the friction induced shear stress.

Palazzolo, Alan B.↗

The US Geological Survey, digital spectral reflectance library: version 1: 0.2 to 3.0 microns

We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 500 spectra of 447 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 microns. The spectral resolution (Full Width Half Maximum) of the reflectance data is less than or equal to 4 nm in the visible (0.2-0.8 microns) and less than or equal 10 nm in the NIR (0.8-2.35 microns). All spectra were corrected to absolute reflectance using an NBS Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from sulfide, oxide, hydroxide, halide, carbonate, nitrate, borate, phosphate, and silicate groups are represented. X-ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses.

Clark, Roger N.↗

Stable isotope analysis of molecular oxygen from silicates and oxides using CO2 laser extraction

A laser-excited system for determination of the oxygen isotope composition of small quantities of silicate and oxide minerals was constructed and tested at JSC. This device is the first reported to use a commercially available helium cryostat to transfer and purify oxygen gas quantitatively within the system. The system uses oxygen gas instead of the conventional CO2 for mass spectrometer analyses. This modification of technique permits determination of all three stable oxygen isotopes, an essential requirement for oxygen isotope analysis of meteoritic material. Tests of the system included analysis of standard silicate materials NBS 28 and UWMG2 garnet, six SNC meteorites, and inclusions and chondrules from the Allende meteorite. Calibration with terrestrial standards was excellent. Meteorite values are close to published values and show no evidence of terrestrial oxygen contamination. The one limitation observed is that, in some runs on fine-grained SNC matrix material, sample results were affected by other samples in the sample holder within the reaction chamber. This reemphasizes the need for special precautions in dealing with fine-grained, reactive samples. Performance of the JSC instrument compares favorably with that of any other instrument currently producing published oxygen isotope data.

Perry, Eugene↗

Launch Deployment Assembly Extravehicular Activity Neutral Buoyancy Development Test Report

This test evaluated the Launch Deployment Assembly (LDA) design for Extravehicular Activity (EVA) work sites (setup, igress, egress), reach and visual access, and translation required for cargo item removal. As part of the LDA design, this document describes the method and results of the LDA EVA Neutral Buoyancy Development Test to ensure that the LDA hardware support the deployment of the cargo items from the pallet. This document includes the test objectives, flight and mockup hardware description, descriptions of procedures and data collection used in the testing, and the results of the development test at the National Aeronautics and Space Administrations (NASA) Marshall Space Flight Center (MSFC) Neutral Buoyancy Simulator (NBS).

Loughead, T.↗

Spectral Emittance of Uncoated and Ceramic-Coated Inconel and Type 321 Stainless Steel

The normal spectral emittance of Inconel and type 321 stainless steel with different surface treatments was measured at temperatures of 900, 1,200, 1,500, and 1,800 F over a wavelength range of 1.5 to 15 microns. The measurements involved comparison of the radiant energy emitted by the heated specimen with that emitted by a comparison standard at the same temperature by means of a recording double-beam infrared spectrophotometer. The silicon carbide comparison standard had previously been calibrated against a laboratory black-body furnace. Surface treatments included electropolishing, sandblasting, electro-polishing followed by oxidation in air for 1/2 hour at 1,800 F, sandblasting followed by oxidation in air for 1/2 hour at 1,800 F, application of National Bureau of Standards coating A-418, and application of NBS ceramic coating N-143. The normal spectral emittance of both alloys in the electropolished condition was low and decreased very slightly with increasing wavelength while in the sandblasted condition it was somewhat higher and did not vary appreciably with wavelength. The oxidation treatment greatly increased the normal spectral emittance of both the electropolished and sandblasted type 321 stainless steel specimens and of the electropolished Inconel specimens and introduced some spectral selectivity into the curves. The oxidation increased the normal spectral emittance of the sandblasted Inconel specimens only moderately. Of the specimens to which a coating about 0.002 inch thick was applied, those coated with A-418 had higher emittance at all wavelengths than did those coated with N-143, and the coated specimens of Inconel had higher spectral emittance at all wavelengths than did the corresponding specimens of type 321 stainless steel. Both coatings were found to be partially transparent to the emitted energy at this thickness but essentially opaque at a thickness of 0.005 inch. Coated specimens with 0.005 inch or more of coating did not show the effect of the underlying metal on spectral emittance, and there was no significant difference at wavelengths greater than about five microns in the normal spectral emittance of specimens having the two coatings. At shorter wavelengths the normal spectral emittance of specimens coated with A-418 was greater than that of specimens coated with N-143.

Richmond, Joseph C.↗