Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Natural circulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigation of Abnormal Heat Transfer and Flow in a VHTR Reactor Core

The main objective of this project was to identify and characterize the conditions under which abnormal heat transfer phenomena would occur in a Very High Temperature Reactor (VHTR) with a prismatic core. High pressure/high temperature experiments have been conducted to obtain data that could be used for validation of VHTR design and safety analysis codes. The focus of these experiments was on the generation of benchmark data for design and off-design heat transfer for forced, mixed and natural circulation in a VHTR core. In particular, a flow laminarization phenomenon was intensely investigated since it could give rise to hot spots in the VHTR core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Analysis of the Passive Residual Heat Removal System of an Integral Reactor

A demand for small modular reactors (SMRs) is gradually emerging worldwide, especially in Middle East Asia and Africa. SMART (System-integrated Modular Advanced ReacTor) developed by KAERI (Korea Atomic Energy Research Institute) is the first mover among several SMRs. It is designed to produce 100 MW of electricity, or 90 MW of electricity and 40,000 tons of desalinated water concurrently, which is sufficient for 100,000 residents. SMART is currently holding the initiative as the first licensed integral reactor in the world since 4 July 2012, when the standard design approval (SDA) was officially issued by the Nuclear safety and security commission (NSSC). After that, the SMART safety enhancement project was successfully conducted with intense support of the Government, resulting in an in-depth development of the most advanced safety features including the passive residual heat removal system (PRHRS). Recently, an agreement between KAERI and King Abdullah city for atomic and renewable energy (K.A. CARE) was officially signed for the pre-project engineering (PPE) in pursuit of the construction of SMART and developing human resources capability. Both parties are currently conducting a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. KAERI also takes responsibility to train R and D personnel chosen from Kingdom of Saudi Arabia. Sooner or later, SMART will open the global market of SMR and be the best competitive pioneer. Since the Fukushima accident, the passive cooling system of a nuclear reactor has received a great amount of attention. SMART is designed with passive systems in order to ensure the safety of the reactor. The PRHRS is one of the passive safety systems, which is activated after an accident to remove the residual heat from the core and the sensible heat of the reactor coolant system (RCS) through the steam generators (SGs) until the condition of the RCS reaches a safe shutdown condition. In the present study, the thermal performance of the PRHRS is predicted by using in-house code. Temperature of the RCS and the cooling rate of the RCS are traced with time to see if it is satisfactorily designed to meet the design requirements of the PRHRS. The dependency of the mass flow rate of the natural circulation on the filling ratio (FR) is also discussed. The FR is arbitrarily chosen from 0.22 to 0.50 and further parametric study is needed in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gravity Scaling of a Power Reactor Water Shield

Water based reactor shielding is being considered as an affordable option for use on initial lunar surface power systems. Heat dissipation in the shield from nuclear sources must be rejected by an auxiliary thermal hydraulic cooling system. The mechanism for transferring heat through the shield is natural convection between the core surface and an array of thermosyphon radiator elements. Natural convection in a 100 kWt lunar surface reactor shield design has been previously evaluated at lower power levels (Pearson, 2007). The current baseline assumes that 5.5 kW are dissipated in the water shield, the preponderance on the core surface, but with some volumetric heating in the naturally circulating water as well. This power is rejected by a radiator located above the shield with a surface temperature of 370 K. A similarity analysis on a water-based reactor shield is presented examining the effect of gravity on free convection between a radiation shield inner vessel and a radiation shield outer vessel boundaries. Two approaches established similarity: 1) direct scaling of Rayleigh number equates gravity-surface heat flux products, 2) temperature difference between the wall and thermal boundary layer held constant on Earth and the Moon. Nussult number for natural convection (laminar and turbulent) is assumed of form Nu = CRa(sup n). These combined results estimate similarity conditions under Earth and Lunar gravities. The influence of reduced gravity on the performance of thermosyphon heat pipes is also examined.

Reid, Robert S.↗

The Phenix ultimate natural convection test

The French sodium cooled fast reactor Phenix was shut down in 2009 after 35 years of operation. Before decommissioning, a final set of tests were performed by the CEA during 9 months. Several topics were involved such as thermal hydraulics, core physics and fuel behaviour. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip of one secondary pump and a natural convection test in the primary circuit. Recognizing the unique opportunity offered by these Phenix ultimate tests, IAEA decided in 2007 to launch a Coordinated Research Project (CRP) devoted to benchmarking analyses with system codes on the Phenix natural convection test. One objective of the natural convection test in Phenix reactor is the assessment of the CATHARE system code for safety studies on future and advanced sodium cooled fast reactors. The aim of this paper is to describe this test, which was performed on June 22-23, 2009, and the associated benchmark specifications for the CRP work. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. After that, the test scenario is described: - initial state at a power of 120 MWth, - test beginning resulting from a manual dry out of the two steam generators, - manual scram, - manual trip on the three primary pumps without back-up by pony motors, - setting and development of natural convection in the primary circuit, in a first phase without significant heat sink in the secondary circuits and in a second phase with significant heat sink in the secondary circuits, by opening the casing of steam generators to create an efficient heat sink, by air natural circulation in the steam generators casing. The benchmark case ends after this second phase, which corresponds to the experimental test duration of nearly 7 hours. The paper presents also the benchmark specifications data supplied by the CEA to all participants of this CRP in order to perform calculations (core, primary circuit, primary pumps, IHX, shutdown system, operating parameters, test scenario and real test conditions). Finally, main test results and analyses are presented including the evolution of the core and of the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The natural convection has been easily set up in the pool type reactor Phenix with different boundary conditions at the secondary side, with or without heat sink. The data obtained during this unique test represent some very useful and precious results for the development of SFR in a wide range of thematic such as numerical methods dedicated to thermal-hydraulics safety analyses (system codes, CFD codes and coupling system and CFD codes) and instrumentation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of in-vessel corium retention through external reactor vessel cooling for integral reactor

In-vessel corium retention through external reactor vessel cooling (IVR-ERVC) for a small integral reactor has been evaluated to determine the thermal margin for the prevention of a reactor vessel failure. A thermal load analysis from the corium pool to the outer reactor vessel wall in the lower plenum of the reactor vessel has been performed to determine the heat flux distribution. The critical heat flux (CHF) on the outer reactor vessel wall has been determined to fix the maximum heat removal rate through the external coolant between the outer reactor vessel and the insulation of the reactor vessel. Finally, the thermal margin has been evaluated by comparison of the thermal load with the maximum heat removal rate of the CHF on the outer reactor vessel wall. The maximum heat flux from the corium pool to the outer reactor vessel is estimated at approximately 0.25 MW/m{sup 2} in the metallic layer because of the focusing effect. The CHF of the outer reactor vessel is approximately 1.1 MW/m{sup 2} because of a two phase natural circulation mass flow. Since the thermal margin for the IVR-ERVC is sufficient, the reactor vessel integrity is maintained during a severe accident of a small integral reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dust divertor for a tokamak fusion reactor

Micron-size tungsten particulates find equilibrium position in the magnetized plasma sheath in the normal direction of the divertor surface, but are convected poloidally and toroidally by the sonic-ion-flow drag parallel to the divertor surface. The natural circulation of dust particles in the magnetized plasma sheath can be used to set up a flowing dust shield that absorbs and exhausts most of the tokamak heat flux to the divertor. The size of the particulates and the choice of materials offer substantial room for optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DNC Simulation Results and Risk Assessment

The performance of Dynamic Natural Circulation (DNC) systems during a station blackout in a pressurizer water reactor was evaluated. Thermal-hydraulic calculations of a PWR with passive DNC systems were performed using RELAP5-3D. The effects of the DNC systems on the cumulative core damage frequency during a station blackout was evaluated using probabilistic and risk assessment methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Supercritical CO2 direct cycle Gas Fast Reactor (SC-GFR) concept.

This report describes the supercritical carbon dioxide (S-CO{sub 2}) direct cycle gas fast reactor (SC-GFR) concept. The SC-GFR reactor concept was developed to determine the feasibility of a right size reactor (RSR) type concept using S-CO{sub 2} as the working fluid in a direct cycle fast reactor. Scoping analyses were performed for a 200 to 400 MWth reactor and an S-CO{sub 2} Brayton cycle. Although a significant amount of work is still required, this type of reactor concept maintains some potentially significant advantages over ideal gas-cooled systems and liquid metal-cooled systems. The analyses presented in this report show that a relatively small long-life reactor core could be developed that maintains decay heat removal by natural circulation. The concept is based largely on the Advanced Gas Reactor (AGR) commercial power plants operated in the United Kingdom and other GFR concepts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integral Effect Test of ATLAS Facility on Multiple Failure in a Prolonged Station Blackout

Since the Fukushima accident, the design extension conditions (DECs) in a nuclear power plant (NPP) have attracted more importance with respect to nuclear reactor safety, and a consensus has been developed such that these high-risk multiple failure accidents should be revisited from the viewpoint of a reinforcement of the 'defense in depth' concept. In particular, a station blackout (SBO) is one of the most important DECs because a loss of the heat sink without an appropriate accident measure might lead to a core uncovery, core damage, and ultimately, a core meltdown under high pressure. SBO has been recognized to be one of the risk-contributing sequences when combined with additional failure of components such as a reactor coolant pump (RCP) seal leakage or a steam generator tube rupture (SGTR). The RCP seal failure could occur due to a loss of continuous cooling through the seal during SBO. The SGTR during SBO can be a potentially important risk due to the release of the fission product with bypassing the containment boundary. The objective of this study is to experimentally simulate and analyze a prolonged SBO scenario in a thermal hydraulic integral effect test facility, ATLAS. As test items in OECD-ATLAS project, two tests for the SBO condition were conducted with additional failures, that is, a RCP seal failure (A2.1 test) and a SGTR (A2.2 test). In those tests, both the effect of the additional failure on reactor safety and the natural circulation characteristics during prolonged SBO conditions could be investigated. The present test can provide physical insight into the system response during the prolonged SBO scenario combined with the multiple failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary safety analysis of Pb-Bi cooled 800 MWt modified CANDLE burn-up scheme based fast reactors

Pb-Bi Cooled fast reactors with modified CANDLE burn-up scheme with 10 regions and 10 years cycle length has been investigated from neutronic aspects. In this study the safety aspect of such reactors have been investigated and discussed. Several condition of unprotected loss of flow (ULOF) and unprotected rod run-out transient over power (UTOP) have been simulated and the results show that the reactors excellent safety performance. At 80 seconds after unprotected loss of flow condition, the core flow rate drop to about 25% of its initial flow and slowly move toward its natural circulation level. The maximum fuel temperature can be managed below 1000°C and the maximum cladding temperature can be managed below 700°C. The dominant reactivity feedback is radial core expansion and Doppler effect, followed by coolant density effect and fuel axial expansion effect.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inherent Prevention and Mitigation of Severe Accident Consequences in Sodium-Cooled Fast Reactors

Safety challenges for sodium-cooled fast reactors include maintaining core temperatures within design limits and assuring the geometry and integrity of the reactor core. Due to the high power density in the reactor core, heat removal requirements encourage the use of high-heat-transfer coolants such as liquid sodium. The variation of power across the core requires ducted assemblies to control fuel and coolant temperatures, which are also used to constrain core geometry. In a fast reactor, the fuel is not in the most neutronically reactive configuration during normal operation. Accidents leading to fuel melting, fuel pin failure, and fuel relocation can result in positive reactivity, increasing power, and possibly resulting in severe accident consequences including recriticalities that could threaten reactor and containment integrity. Inherent safety concepts, including favorable reactivity feedback, natural circulation cooling, and design choices resulting in favorable dispersive characteristics for failed fuel, can be used to increase the level of safety to the point where it is highly unlikely, or perhaps even not credible, for such severe accident consequences to occur.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of strong-sense validation benchmarks for the fluoride salt-cooled high-temperature reactor

The Fluoride salt-cooled High-temperature Reactor (FHR) is a class of reactor concepts currently under development for the U. S. Dept. of Energy. The FHR is defined as a Generation IV reactor that features low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. Recent experimental work using simulant fluids have been performed to demonstrate key 'proof of principle' FHR concepts and have helped inform the reactor design process. An important element of developing FHR technology is to sufficiently validate the predictive accuracy of the computer codes used to model system response. This paper presents a set of thermal-hydraulics experiments, defined as Strong-Sense Benchmarks (SSB's), which will help establish the FHR validation domain for simulant fluid suitability. These SSB's are more specifically designed to investigate single-phase natural circulation which is the dominant mode of FHR decay heat removal during off-normal conditions. SSB s should be viewed as engineering reference standards and differ from traditional confirmatory experiments in the sense that they are more focused on fundamental physics as opposed to reproducing high levels of physical similarity with the prototypical design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CATHARE thermal-hydraulic system code for HLM preliminary validation in natural convection tests

The innovative nuclear systems cooled by Heavy Liquid Metal (HLM) are the subject of an ongoing interest both in Europe and outside, evidenced by a number of projects in progress. In the frame of the European Framework Programmes have been evidenced the need to adopt a thermalhydraulic system code capable to treat lead and Lead-Bismuth Eutectic (LBE) systems, with a particular interest in developing a 'European' code. Considering this scenario, within a specific collaboration between ENEA and CEA, the CATHARE French system code has been modified extending its capabilities to simulate HLM systems. In the present paper, the state of the validation process of CATHARE-HLM is discussed. The activity aims to assess the capabilities and limitations of the code to simulate the behavior of integral facilities, in particular in natural circulation conditions. The experimental data come from NACIE LBE-cooled facility sited at the ENEA Brasimone laboratories. The results obtained show a good capability in reproducing the systems behavior, despite some uncertainties on the experimental measurements. Future improvements on the code are going to be planned within the collaboration ENEA/CEA. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mixed effects associated with air ingress in graphite channels

The next generation of nuclear power plants, such as Modular High Temperature Gas-Cooled Reactors (MHTGR), have passive safety design features to overcome transients during off-normal operation but it is unproven whether their safety systems will perform as per design requirements. The design and construction of a facility, to investigate the passive safety response of the complete reactor system will require significant resources. Therefore, a practical approach is to improve the understanding of this multi-physics or mixed effect problem in laboratory scale set-ups and computational models. The HTGR related separate effects experiments at academic institutions and other laboratories have been developed to provide validation data and complement computational efforts to identify critical issues related to passive safety design. There are several separate effect experimental studies currently under investigation or recently conducted by several academic institutions in U.S and throughout the world. The High Temperature Test Facility (HTTF) has been constructed at Oregon State University to conduct integral thermal-hydraulics experiments for the development of HTGRs. For Depressurized Conduction Cooling (DCC) experiments in HTTF, a mixture of nitrogen and helium gas is used to study internal natural convection up to 650?C. Similarly many other experimental studies have emphasized on HTGR core and plenum-to-plenum thermal-hydraulic behavior but with inert gases such as nitrogen or non-oxidizing solid substitutes for graphite. There is limited experimental data of mixed oxidation effects upon air ingress in nuclear grade graphite leading changes to thermal properties, heat generation due to chemical reactions and natural convection of air-helium mixture inside core at high temperatures (above 900?C). This work describes a unique experimental set-up developed by authors to conduct these mixed effect experiments. The current work is equally relevant to the designs well known by other names or geometries such as Very High Temperature Reactors (VHTRs) and Pebble Bed Modular Reactors (PBMRs). A common feature of HTGRs with passive safety design is that under certain accident conditions the decay heat is dissipated passively from the core by radiation/conduction/convection heat transport to the surrounding environment. Passive decay heat removal is one of the prime passive safety features of HTGRs and the heat conduction through the internal core region, graphite matrix, to the periphery is one of the major mechanisms of passive safety in HTGRs. The conduction and radiation heat transfer provide long-term heat removal but, during a Depressurized Loss of Forced Coolant (DLOFC) accident, the anticipated break in the coolant system will allow air ingress into the hot core region and can lead to graphite oxidation, which will negatively impact the core thermal behavior. In addition, air will also impact natural circulation of Helium and thus diminish the heat removal rate, which can further increase the graphite temperature. Therefore, both air ingress can eventually give rise to thermal instabilities and then to possible situations for breaching the safety envelope of TRISO fuel. This research summary is organized to present the background on oxidation studies, description of experimental setup and discussion of results in the following sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Minimization of Nuclear Waste using AHWR Reactor Technology

Nuclear sciences have grown from creating reactors to a greater understanding of how to dispose off the waste exhibited by the nuclear activities. Various methodologies have been proposed and are being used in order to do the same. This poster poses great attention to 'Using a fuel cycle dedicated to the production of the lower quantity of minor actinides, is one of the key targets in reducing nuclear waste in india'. A significant fraction of thorium is utilized as a fertile host in the Advanced Heavy Water Reactor (AHWR300-LEU) fuel. Being lower in the periodic table, it leads to a reduction of minor actinides. It produces only half of the minor actinides as a waste as compared to modern LWRs. As thorium oxide has inert nature, it benefits in its prolonged storage. Therefore, safe disposal of spent fuel is achieved due to the inert matrix, on completion of one fuel cycle mode. AHWR is a 300 MWe, vertical, pressure-tube type, boiling light water-cooled, and heavy water-moderated reactor. Employs natural circulation for removal of heat from the reactor core. In-situ conversion of {sup 232}Th into {sup 233}U. The reactor design permits flexible fuel cycle options. There are two types of AHWR depending upon the fuel cycle options. Uses thorium-based oxide fuels: two fuel cycle options. With the adoption of thorium fuel cycle, AHWR300-LEU produces less minor actinides. As compared to modern LWRSs, it produces almost 37% less amount of actinides for the same amount of energy production, which in turn minimizes the burden on waste disposal requirements. But, it is associated with radionuclides such as {sup 231}Pa (produced through absorption of one neutron and emission of two neutrons). Since, the reaction rate of (n,2n) reactions is very low in thermal neutron reactors, thus making the fuel cycle the favorable one. Thorium oxide (ThO{sub 2}) is chemically stable and is the highest oxidation state of thorium, therefore the inert nature of the matrix is advantageous for safe disposal of spent fuel in case of adoption of open fuel cycle mode and offers prolonged storage of spent fuel. The AHWR is thorium fueled Indian nuclear reactor that assimilates several new features with diminished environmental concern due to reduced waste generation. Since thorium fuel cycle produces less long lived nuclear waste, thus it can possibly bring the world cleaner and more sustainable nuclear energy. Currently, India being the only country with large scale research program of thorium nuclear power serves a platform for the development and demonstration of all technologies and advanced safety systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification of Analytical Test Based Thermohydraulic Systems Codes for One- and Two-Phase Liquid-Metal Flows

This work is devoted to the development of a system of analytical tests for verification of the thermohydraulic codes used in modeling the flow of one- and two-phase flows of liquid metals. The change of temperature in constant and variable flow of coolant, effect of axial heat conduction of the coolant on the temperature distribution, development of natural circulation in a closed loop, motion of a two-phase mixture under gravity, and fluctuations of the gas volume and distribution of the true process steam content in the presence of boiling/condensation are studied. The developed system of tests was used to verify the HYDRA-IBRAE/LM thermohydraulic code and the thermohydraulic module of the SOKRAT-BN code. The computational errors in the individual thermohydraulic parameters are obtained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Confirmatory Survey Results for Portions of the Materials and Equipment from Units 1 and 2 at the Humboldt Bay Power Plant, Eureka, California

The Pacific Gas & Electric Company (PG&E) operated the Humboldt Bay Power Plant (HBPP) Unit 3 nuclear reactor near Eureka, California under Atomic Energy Commission (AEC) provisional license number DPR-7. HBPP Unit 3 achieved initial criticality in February 1963 and began commercial operations in August 1963. Unit 3 was a natural circulation boiling water reactor with a direct-cycle design. This design eliminated the need for heat transfer loops and large containment structures. Also, the pressure suppression containment design permitted below-ground construction. Stainless steel fuel claddings were used from startup until cladding failures resulted in plant system contamination—zircaloy-clad fuel was used exclusively starting in 1965 eliminating cladding-related contamination. A number of spills and gaseous releases were reported during operations resulting in a range of mitigative activities (see ESI 2008 for details).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗