Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Muon System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Octopus processor for the CMS L1 muon trigger for High Luminosity LHC

The upgraded L1 muon trigger system of the CMS experiment in the High Luminosity Large Hadron Collider is based on custom processors featuring large Field Programmable Gate Arrays (FPGAs) connected by large numbers of optical links. These provide the I/O bandwidth and power necessary to process the complex algorithms used during the collection of physics data. The design and performance requirements of these processors creates significant challenges in signal integrity, power delivery, and thermal management. In this paper we describe the Octopus processor, featuring a large Xilinx Virtex Ultrascale+ FPGA and up to 128 links interfaced to optics through high quality twin-ax copper cables. Results on signal integrity at 25 Gb/s and the first demonstration of 50+ Gb/s links with pluggable optics in CMS are also shown, demonstrating bit error rates below 10 –15 at a 95% confidence level. The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. Future improvements are mentioned, potentially allowing operation at up to 300 W.

Instruments & Instrumentation↗

Numerical Study of a Passive Wedge Absorber System for Momentum Selection of Muon Beams

The Muon g-2 experiment aims to measure the anomalous magnetic moment of the muon with higher precision than previous experiments. In order to do this muons are created from protons hitting the target and are then sent to the M4 and M5 lines to be injected into the storage ring. The storage ring only accepts muons with momentum within 0.2% of 3094 MeV/c. In order to decrease the number of lost muons a wedge was placed in the M5 beam line to utilize the properties of ionization cooling to create a more uniform momentum spread. Previous simulations predicted a much larger gain of storable muons than the experimental results showed. In order to determine the cause of this discrepancy, simulations were run using a GEANT4 based code to track muons through the M4 and M5 lines, the inflector, and the storage ring while adjusting the orientation, material, geometrical parameters and studying the performance of this wedge for a wide range of incoming muon energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

Design and Fabrication of the Mu2e Cryogenic Distribution System

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the design and construction stage and is expected to begin operations in 2022. The Mu2e experiment uses four large superconducting solenoid magnets including a Production Solenoid (PS), an Upstream and Downstream Transport Solenoid (TSu and TSd) and a Detector Solenoid (DS). This paper will focus on the cryogenic distribution system for these four solenoid magnets. Liquid helium will be supplied from two re-purposed Tevatron satellite refrigerators. A large cryogenic distribution box (DB) is located in the Mu2e building to distribute the required cryogens to each of the four solenoid magnets. Each solenoid magnet will have a dedicated transfer line and cryogenic feed box (FB). The solenoid magnets each require two liquid helium circuits and two liquid nitrogen circuits. The most unique feature about this cryogenic system is that the assemblies for the start of the superconducting portion of the power leads are mounted in feed boxes that are in the range of 23 m to 31 m away from the solenoid magnets. The cryogenic feed boxes are located remotely to provide protection from radiation damage and high magnetic fields. The power leads are NbTi superconducting cable stabilized with high conductivity aluminum. The 6061-T6 aluminum grade was selected for the transfer line piping so that the piping would thermally contract at the same rate as the power lead. A major concern for this transfer line is that a small helium leak could create an electric discharge arc due to the Paschen effect. This paper includes a description of the design features and testing done to ensure that the power leads are protected from the Paschen effect while still being adequately cooled to liquid helium temperatures.

43 PARTICLE ACCELERATORS↗

Imaging Shielded Configurations Using Near-Horizontal and Near-Vertical Trajectory Cosmic-Ray Muons

This work will describe the proof-of-concept research applying muon tomography technologies based on drift tube systems to create images using near–horizontal trajectory muons. To date, the majority of imaging studies using cosmic-ray muons have used near–vertical trajectory muons. This work compares imaging results using near–vertical trajectory muons with results using near–horizontal trajectory muons. The muon flux is much lower for the near–horizontal trajectory muons, so requiring longer imaging times, but the average muon energy is higher, so the horizontal results are expected to better differentiate high-Z materials. The muon tracking system is easily configurable and can be oriented to capture near–vertical trajectory or near– horizontal trajectory cosmic-ray muons. The software can track each muon passing through the system, and generate 3-D images of the scene. The experimental design and preliminary results will be presented, including the comparisons of detection efficiency, image resolution, and integration times.

muon, passive, imaging, tomography, cosmic↗

Design of Helical Solenoid Combined with RF Cavity

Helical Solenoids (HS) were proposed for a muon beam ionization cooling. There are substantial energy losses, up to 30 MeV/m, during the passing of the muon beam through the absorber. The main issue of such a system is the muon beam energy recovery. A conventional RF cavity is too large to be placed inside HS. In the paper the results of a dielectric-filled RF cavity design is presented. The proposed RF cavity has a helical configuration. Helical Cooling Channel (HCC) module design which includes high pressure vessel, RF cavity, and superconducting HS is presented. The parameters of these module sub-systems are discussed, and the results of muon beam tracking in combined magnetic and electric 3D fields are shown.

43 PARTICLE ACCELERATORS↗

Electron-Muon Ranger: Performance in the MICE muon beam

The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. Lastly, the EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100–280 MeV/c.

43 PARTICLE ACCELERATORS↗

Imaging and sensing based on muon tomography

Techniques, apparatus and systems for detecting particles such as muons for imaging applications. Subtraction techniques are described to enhance the processing of the muon tomography data.

47 OTHER INSTRUMENTATION↗

20 years of cosmic muons research performed in IFIN-HH

During the last two decades a modern direction in particle physics research has been developed in IFIN-HH Bucharest, Romania. The history started with the WILLI detector built in IFIN-HH Bucharest in collaboration with KIT Karlsruhe (formerly Forschungszentrum Karlsruhe). The detector was designed for measurements of the low energy muon charge ratio (< 1GeV) based on a delayed coincidence method, measuring the decay time of the muons stopped in the detector: the positive muons decay freely, but the negative muons are captured in the atom thus creating muonic atoms and decay depending on the nature of the host atom. In a first configuration, the WILLI detector was placed in a fixed position for measuring vertical muons. Further WILLI has been transformed in a rotatable device which allows directional measurements of muon charge ratio and muon flux. The results exhibit a pronounced azimuthal asymmetry (East-West effect) due to the different in fluence of the geomagnetic field on the trajectories of positive and negative muons in air. In parallel, flux measurement, taking into account muon events with nergies > 0.4GeV, show a diurnal modulation of the muon flux. The analysis of the muon events for energies < 0.6GeV reveals an aperiodic variation of the muon flux. A new detection system performing coincidence measurements between the WILLI calorimeter and a small array of 12 scintillators plates has been installed in IFIN-HH starting from the autumn of 2010. The aim of the system is to investigate muon charge ratio from individual EAS by using the mini-array as trigger for the WILLI calorimeter. Such experimental studies could provide detailed information on hadronic interaction models and primary cosmic ray composition at energies around 10{sup 15}eV. Simulation studies and preliminary experimental tests, regarding the performances of the mini-array, have been performed using H and Fe primaries, with energies in a range 10{sup 13}eV - 10{sup 15}eV. The results show detailed effects of the direction of EAS incidence relative to the geomagnetic field, depending, in particular, of the primary mass. Based on the results, we can say that WILLI-EAS experiment could be used for testing the hadronic interaction models. Measurements of the high energy muon flux in underground of the salt mine from Slanic Prahova, Romania was performed using a new mobile detector developed in IFIN-HH, Bucharest. Consisting of 2 scintillator plates measuring in coincidence, the detector is installed on a van which facilitates measurements on different positions at surface or in underground. The detector was used to measure muon fluxes in different locations at surface or in underground. The detector was used to measure muon fluxes at different sites of Romania and in the underground of the salt mines from Slanic Prahova, Romania where IFIN-HH has a modern underground laboratory. New methods for the detection of cosmic ray muons are investigated in our institute based on scintillator techniques using optical fiber and MPPC photodyodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

Final Cooling for a Muon Collider

To explore the new energy frontier, a new generation of particle accelerators is needed. Muon colliders are a promising alternative, if muon cooling can be made to work. Muons are 200 times heavier than electrons, so they produce less synchrotron radiation, and they behave like point particles. However, they have a short lifetime of 2.2 $\mathrm{\mu s}$ and the beam is more difficult to cool than an electron beam. The Muon Accelerator Program (MAP) was created to develop concepts and technologies required by a muon collider. An important effort has been made in the program to design and optimize a muon beam cooling system. The goal is to achieve the small beam emittance required by a muon collider. This work explores a final ionization cooling system using magnetic quadrupole lattices with a low enough $\beta^{\star} $ region to cool the beam to the required limit with available low Z absorbers.

43 PARTICLE ACCELERATORS↗

Realization of a high luminosity muon beam at the Jefferson Lab

The proton is the major component of the visible matter of our universe, so being able to determine its fundamental properties, such as its charge radius, is of vital importance. In recent years, several experiments have been performed for the accurate measurement of the proton radius with different experimental techniques. The main and most common are based on two different techniques: ep scattering and Lamb shift spectroscopy of regular hydrogen atoms. The latter can also be performed on muonic hydrogen atoms with a significant improvement in accuracy. Recent measurements that use this method have highlighted a discrepancy between the results obtained with the diffusion of electrons and those obtained with the spectroscopic technique leading to the so-called ?proton radius puzzle?. The explanation of why this difference between the measured values exists is still a matter of discussion. The last attempt to address the puzzle was the PRad Experiment. It was performed with a unique experimental setup that gave the scientists an excellent control on the systematic errors that are usually present in electron-proton scattering experiments. This has significantly increased the precision of the measurement, bringing it in the same area as the spectroscopic ones done on muonic hydrogen atoms, which are considered the most precise. However, to solve the puzzle once and for all, even more precise electron scattering measurements are needed. Alternatively, new methods can be used, such as eg. muon-proton scattering at low transferred momenta in order to lower the systematic errors that comes with the measurement. This thesis tries to address this problem by studying the set up of an intense muon beam at the Jefferson Laboratory (JLab) that can be used to carry out a high-precision m ? p scattering experiment. Using Montecarlo simulations I studied the muon production resulting from the interaction of the primary electron beam with the beam-dump at JLab Hall-A. The simulations were performed using the FLUKA package via the FLAIR graphical interface. In this study, I modified an existing geometry (built for the ?Beam Dump eXperiment?) and performed several studies in order to optimize the muon beam parameters. In order to estimate the beam intensity, I studied the muon generation and transportation through the concrete bunker surrounding the Hall-A beam-dump. Detailed studies on muon attenuation and dispersion at different depth allowed me to track the beam profile in space and momentum as a function of the distance from the beam-dump. Last, but not least, I studied a possible tagging system for the muon beam. The tagging system will allow us to know with good precision (O(1=1000)) the energy of each muon of the beam. Based on the results obtained, I created an event generator that incorporates the detailed description of the muon beam (energy, position, emittance) useful to define and optimize the experimental setup for a future measurement of the proton radius at the JLab.

Fulci, Antonino↗

Muon Collider interaction region and machine-detector interface design

One of the key systems of a Muon Collider (MC) - seen as the most exciting option for the energy frontier machine in the post-LHC era - is its interaction region (IR). Designs of its optics, magnets and machine-detector interface are strongly interlaced and iterative. As a result of recent comprehensive studies, consistent solutions for the 1.5-TeV c.o.m. MC IR have been found and are described here. To provide the required momentum acceptance, dynamic aperture and chromaticity, an innovative approach was used for the IR optics. Conceptual designs of large-aperture high-field dipole and high-gradient quadrupole magnets based on Nb{sub 3}Sn superconductor were developed and analyzed in terms of the operating margin, field quality, mechanics, coil cooling and quench protection. Shadow masks in the interconnect regions and liners inside the magnets are used to mitigate the unprecedented dynamic heat deposition due to muon decays ({approx}0.5 kW/m). It is shown that an appropriately designed machine-detector interface (MDI) with sophisticated shielding in the detector has a potential to substantially suppress the background rates in the MC detector.

43 PARTICLE ACCELERATORS↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tapered Six-Dimensional Cooling Channel for a Muon Collider

A high-luminosity muon collider requires a reduction of the six-dimensional emittance of the captured muon beam by a factor of {approx} 10{sup 6}. Most of this cooling takes place in a dispersive channel that simultaneously reduces all six phase space dimensions. We describe a tapered 6D cooling channel that should meet the requirements of a muon collider. The parameters of the channel are given and preliminary simulations are shown of the expected performance. A complete scheme for cooling a muon beam sufficiently for use in a muon collider has been previously described. This scheme uses separate 6D ionization cooling channels for the two signs of the particle charge. In each, a channel first reduces the emittance of a train of muon bunches until they can be injected into a bunch-merging system. The single muon bunches, one of each sign, are then sent through a second tapered 6D cooling channel where the transverse emittance is reduced as much as possible and the longitudinal emittance is cooled to a value below that needed for the collider. The beam can then be recombined and sent through a final cooling channel using high-field solenoids that cools the transverse emittance to the required values for the collider while allowing the longitudinal emittance to grow. This paper mainly describes the design of the 6D cooling channel before bunch merging. Cooling efficiency is conveniently measured using a parameter Q, which is defined as the rate of change of 6D emittance divided by the rate of change of the number of muons in the beam. In a given lattice Q starts off small due to losses from initial matching, then rises to a large value (Q {approx} 15 is typical for the channels discussed here), and finally falls as the emittance of the beam approaches its equilibrium value. The idea for the 6D cooling channel described here originated with the RFOFO cooling ring. This design evolved into a helical channel referred to as a 'Guggenheim' in order to avoid serious problems with injection of large emittance beams. We found that good cooling efficiency requires that the channel be tapered. In that case when Q starts to fall off the lattice is modified to reduce the beta function. This ensures that the beam emittance is always large compared with the equilibrium emittance.

43 PARTICLE ACCELERATORS↗