Argon gas-puff radius optimiaztion for Saturn operating in the long-pulse mode.

Argon gas puff experiments using the long pulse mode of Saturn (230-ns rise time) have promise to increase the coupled energy and simplify operations because the voltage is reduced in vacuum and the forward-going energy is higher for the same Marx charge. The issue addressed in this work is to determine if the 12-cm-diameter triple nozzle used in Saturn long-pulse-mode experiments to date provides maximum K-shell yield, or if a different-radius nozzle provides additional radiation. Long-pulse implosions are modeled by starting with measured density distributions from the existing 12-cm-diameter nozzle, and then varying the outer radius in an implosion-energy-conserving self-similar manner to predict the gas-puff diameter that results in the maximum K-shell yield. The snowplow-implosions and multi-zone radiation transport models used in the analysis are benchmarked against detailed measurements from the 12-cm-diameter experiments. These calculations indicate that the maximum K-shell emission is produced with very nearly the existing nozzle radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of 12C + 12C rate uncertainties on the weak s-process component

The contribution by massive stars (M > 15M{sub {circle_dot}}) to the weak s-process component of the solar system abundances is primarily due to the {sup 22}Ne neutron source, which is activated near the end of helium-core burning. The residual {sup 22}Ne left over from helium-core burning is then reignited during carbon burning, initiating further s-processing that modifies the isotopic distribution. This modification is sensitive to the stellar structure and the carbon burning reaction rate. Recent work on the {sup 12}C + {sup 12}C reaction suggests that resonances located within the Gamow peak may exist, causing a strong increase in the astrophysical S-factor and consequently the reaction rate. To investigate the effect of such a rate, 25M{sub {circle_dot}} stellar models with different carbon burning rates, at solar metallicity, were generated using the Geneva Stellar Evolution Code (GENEC) with nucleosynthesis post-processing calculated using the NuGrid Multi-zone Post-Processing Network code (MPPNP). A strongly enhanced rate can cause carbon burning to occur in a convective core rather than a radiative one and the convective core mixes the matter synthesized there up into the carbon shell, significantly altering the initial composition of the carbon-shell. In addition, an enhanced rate causes carbon-shell burning episodes to ignite earlier in the evolution of the star, igniting the {sup 22}Ne source at lower temperatures and reducing the neutron density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated Translation and Thermal Zoning of Digital Building Models for Energy Analysis

Building energy simulation is valuable during the early stages of design, when decisions can have the greatest impact on energy performance. However, preparing digital design models for building energy simulation typically requires tedious manual alteration. This paper describes a series of five automated steps to translate geometric data from an unzoned CAD model into a multi-zone building energy model. First, CAD input is interpreted as geometric surfaces with materials. Second, surface pairs defining walls of various thicknesses are identified. Third, normal directions of unpaired surfaces are determined. Fourth, space boundaries are defined. Fifth, optionally, settings from previous simulations are applied, and spaces are aggregated into a smaller number of thermal zones. Building energy models created quickly using this method can offer guidance throughout the design process.

97 MATHEMATICS AND COMPUTING↗

Blower-door techniques for measuring interzonal leakage

Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

99 GENERAL AND MISCELLANEOUS↗

Automatic building information model query generation

Energy efficient building design and construction calls for extensive collaboration between different subfields of the Architecture, Engineering and Construction (AEC) community. Performing building design and construction engineering raises challenges on data integration and software interoperability. Using Building Information Modeling (BIM) data hub to host and integrate building models is a promising solution to address those challenges, which can ease building design information management. However, the partial model query mechanism of current BIM data hub collaboration model has several limitations, which prevents designers and engineers to take advantage of BIM. To address this problem, we propose a general and effective approach to generate query code based on a Model View Definition (MVD). This approach is demonstrated through a software prototype called QueryGenerator. In conclusion, by demonstrating a case study using multi-zone air flow analysis, we show how our approach and tool can help domain experts to use BIM to drive building design with less labour and lower overhead cost.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Combustion Models for CFD Simulation of Pre-Chamber Ignition in a Natural Gas Engine

Natural gas is considered an attractive alternative fossil fuel as it produces 25% less carbon dioxide and emits fewer amounts of toxic pollutants compared to gasoline and diesel. A pre-chamber type ignition device in a natural gas engine is capable of extending the lean operating limit, and hence improving thermal efficiency, by providing spatially distributed ignition with multiple turbulent flame-jets and accelerating the combustion rate. However, the process of ignition in the main chamber triggered by turbulent jets emanating from a pre-chamber is very sensitive to the pre-chamber geometry and fueling strategy, and any effort to optimize these parameters requires fundamental understanding of the underlying physical and thermodynamic phenomena, which can be studied by a multi-dimensional numerical simulation approach. In this study, three turbulent combustion models widely adopted in the multi-dimensional engine modeling community were preliminary evaluated to simulate the combustion process in a natural gas engine with a pre-chamber spark-ignition system. One multi-zone well-stirred reactor model, and two flamelet-based combustion models, G-equation and Extended Coherent Flamelet Model, were employed for this assessment. Under a fuel-lean condition, the three combustion models were used to match experimental data and analyze the differences in terms of in-cylinder pressure and heat release rate.

combustion model evaluation↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

Computational Models for Crystal Growth of Radiation Detector Materials: Growth of CZT by the EDG Method

Crystals are the central materials element of most gamma radiation detection systems, yet there remains surprisingly little fundamental understanding about how these crystals grow, how growth conditions affect crystal properties, and, ultimately, how detector performance is affected. Without this understanding, the prospect for significant materials improvement, i.e., growing larger crystals with superior quality and at a lower cost, remains a difficult and expensive exercise involving exhaustive trial-and-error experimentation in the laboratory. Thus, the overall goal of this research is to develop and apply computational modeling to better understand the processes used to grow bulk crystals employed in radiation detectors. Specifically, the work discussed here aims at understanding the growth of cadmium zinc telluride (CZT), a material of long interest to the detector community. We consider the growth of CZT via gradient freeze processes in electrodynamic multi-zone furnaces and show how crucible mounting and design are predicted to affect conditions for crystal growth. (authors)

36 MATERIALS SCIENCE↗

An Efficient Tool-Set for Modeling Containment Ventilation in Very Complex Facilities - 17215

The applicability of a multi-zone ventilation analysis program, CONTAM, to complex radioactive waste material handling or processing plants is evaluated. Validation results are based on simulations from three-dimensional multi-physics computational fluid dynamics. Insight into the application limits of CONTAM and conditions under which the use of higher fidelity tools are required are also discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Evaluating Chemical Kinetics Predictions for Propane Using 3-D and 0-D Models in a Boosted Spark-Ignited Engine

Propane has been shown to be a promising alternative fuel to reduce emissions while simultaneously achieving high efficiencies in medium- and heavy-duty engines. These high-power density applications require boosted engines which, combined with high compression ratio, can lead to auto-ignition and knock. While three-dimensional (3-D) computational fluid dynamics (CFD) models are often used for resolving the complex fluid flow in engines, these models can become computationally expensive when simulating detailed chemical kinetics. Likewise, zero-dimensional (0-D) models are computationally concise enough for kinetics development, but lack any flow-field information which governs the flame propagation processes in spark ignition (SI) engines. This work presents a comprehensive comparison between 3-D and 0-D closed cycle simulations at knocking conditions in a high compression ratio high stroke-to-bore ratio propane engine. In order to initialize the flow-field for the 3-D closed cycle (intake valve closing, (IVC) to exhaust valve opening, (EVO)) simulation, a motored multi-cycle 3-D model was run using Converge to create a map at IVC, reducing the computational time. The map allowed a non-homogeneous 3-D closed cycle simulation to be satisfactorily validated against experiments, while a homogeneous case using only the turbulence field mapping was also simulated, mimicking 0-D modeling. The 3-D simulations were used to prescribe the initial conditions (e.g., IVC thermodynamics, speciation, burn-rate profile) for a 2-zone 0-D SI engine model in Chemkin Pro for both cases. It was found that 2-zone 0-D modeling underpredicted the knock onset timing, likely due to the lack of thermal stratification in the unburned gas region. Future work will carry multi-zone 0-D modeling to capture the fuel auto-ignition in the unburned region.

Douvry-Rabjeau, Julien [Oakland University, Roches↗

Broadband multiwavelength properties of the archetypal blazar 3C 279 during the 2017 Event Horizon Telescope campaign

The archetypal blazar 3C 279 hosts a prominent relativistic jet and exhibits strong broadband variability across the electromagnetic spectrum. In April 2017, the Event Horizon Telescope (EHT) observed 3C 279, alongside one of the most extensive quasi-simultaneous multiwavelength (MWL) campaigns ever conducted. With the aim of investigating the physical processes governing 3C 279, we analyzed individual observations and multiband light curves, and constructed a new quasi-simultaneous MWL spectrum. We also performed phenomenological modeling using the turbulent extreme multi-zone (TEMZ) model to constrain the fundamental physical properties of the source. The EHT observations reveal a clear flux increase in the innermost core between April 5 and 11, 2017. Over a broader timescale, radio measurements at longer wavelengths show concurrent enhancements in core flux and polarization around mid-April, coinciding with the ejection of a superluminal knot. Record UV-optical flares with strong polarization variability occurred in late March, followed by gamma-ray activity that declined before the end of the EHT observing period. During this interval, the source remained in a low X-ray state and showed no detectable VHE emission. The TEMZ modeling suggests that the broadband spectrum and variability of 3C 279 can be explained within a jet scenario in which turbulent plasma cells are compressed by a stationary conical shock. However, alternative interpretations, such as magnetic reconnection or a moving shock-in-jet event, remain plausible. This coordinated MWL campaign advances our understanding of the origin of jet and gamma-ray emission in 3C 279, while also providing a comprehensive publicly available dataset that will serve as a valuable reference for future studies.

Principe, G. [Trieste U.; INFN, Trieste; Bologna, ↗

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple-Zone Variable Refrigerant Flow System Modeling and Equipment Performance Mapping

We developed a variable refrigerant flow (VRF) vapor compression system model, which has five indoor units, one outdoor unit and one water heater. The VRF system can run simultaneous space conditioning (cooling or heating) and water heating. The indoor units and outdoor unit use fin-&-tube coil heat exchangers, and the water heater uses a tube-in-tube heat exchanger. The fin-&-tube coil heat exchangers are modeled using a segment-by-segment approach and the tube-in-tube water heater is modeled using a phase-by-phase approach. The compressor used is a variable-speed rotary design. We calibrated our model against a manufacturer s product literature. Based on the vapor compression system model, we investigated the methodology for generating VRF equipment performance maps, which can be used for energy simulations in TRNSYS and EnergyPlus, etc. In the study, the major independent variables for mapping are identified and the deviations between the simplified performance map and the actual equipment system simulation are quantified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗