Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Embedding and Effective Downfolding in the Auxiliary-Field Quantum Monte Carlo Method

A local embedding and effective downfolding scheme has been developed and implemented in the auxiliary-field quantum Monte Carlo (AFQMC) method. A local cluster in which electrons are fully correlated is defined, and the frozen orbital method is used on the remainder of the system to construct an effective Hamiltonian, which operates within the local cluster. Local embedding, which involves only the occupied sector, has previously been employed in the context of Co/graphene. Here, the methodology is extended in order to allow for effective downfolding of the virtual sector, thus allowing for significant reduction in the computational effort required for AFQMC calculations. The system size, which can be feasibly treated with AFQMC, is therefore greatly extended as only a single local cluster is explicitly correlated at the AFQMC level of theory. The approximation is controlled by the separate choice of the spatial size of the active occupied region (Ro) and of the active virtual region (Rv). In conclusion, the systematic dependence of the AFQMC energy on Ro and Rv is investigated, and it is found that relative AFQMC energies of physical and chemical interest converge rapidly to the full AFQMC treatment (i.e., using no embedding or downfolding).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave Analysis with Monte Carlo Methods for ECH Transmission Lines

A new code framework, MORAMC, is presented which model transmission line (TL) systems consisting of overmoded circular waveguide and other components including miter bends and transmission line gaps. The transmission line is modeled as a set of mode converters in series where each component is composed of one or more converters. The parametrization of each mode converter can account for the fabrication tolerances of physically realizable components. These tolerances as well as the precision to which these TL systems can be installed and aligned gives a practical limit to which the uncertainty of the microwave performance of the system can be calculated. Because of this, Monte Carlo methods are a natural fit and are employed to calculate the probability distribution that a given TL can deliver a required power and mode purity. Several examples are given to demonstrate the usefulness of MORAMC in optimizing TL systems.

47 OTHER INSTRUMENTATION↗

Suppressing nonphysical overheating with a modified implicit Monte Carlo method for time-dependent radiative transfer

In this note we develop a robust implicit Monte Carlo (IMC) algorithm based on more accurately updating the linearized equilibrium radiation energy density. The method does not introduce oscillations in the solution and has the same limit as {Delta}t{yields}{infinity} as the standard Fleck and Cummings IMC method. Moreover, the approach we introduce can be trivially added to current implementations of IMC by changing the definition of the Fleck factor. Using this new method we develop an adaptive scheme that uses either standard IMC or the modified method basing the adaptation on a zero-dimensional problem solved in each cell. Numerical results demonstrate that the new method alleviates both the nonphysical overheating that occurs in standard IMC when the time step is large and significantly diminishes the statistical noise in the solution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topics in structural dynamics: Nonlinear unsteady transonic flows and Monte Carlo methods in acoustics

The results are reported of two unrelated studies. The first was an investigation of the formulation of the equations for non-uniform unsteady flows, by perturbation of an irrotational flow to obtain the linear Green's equation. The resulting integral equation was found to contain a kernel which could be expressed as the solution of the adjoint flow equation, a linear equation for small perturbations, but with non-constant coefficients determined by the steady flow conditions. It is believed that the non-uniform flow effects may prove important in transonic flutter, and that in such cases, the use of doublet type solutions of the wave equation would then prove to be erroneous. The second task covered an initial investigation into the use of the Monte Carlo method for solution of acoustical field problems. Computed results are given for a rectangular room problem, and for a problem involving a circular duct with a source located at the closed end.

Haviland, J. K.↗

Determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for detectors used with an 800 MU/min CyberKnife{sup ®} system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method

Purpose: In a previous work, output ratio (OR{sub det}) measurements were performed for the 800 MU/min CyberKnife{sup ®} at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OF{sub MC,w}) and the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. Methods: The LINAC head of the CyberKnife{sup ®} was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (OR{sub MC,det}) and OF{sub MC,w} were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Results: Looking at measurement ratios (uncorrected output factors) compared to the OF{sub MC,w}, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about −12% for the 5 mm field). OR{sub det} measured with the SFD diode and PTW 60003 diamond detectors were in good agreement with OF{sub MC,w} except for the 5 mm field size (about −7.5% for the diamond and +3% for the SFD). A good agreement with OF{sub MC,w} was obtained with the EBT2 film and micro-LiF dosimeters (deviation less than 1.4% for all fields investigated). k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for several detectors used in this work have been calculated. The impact of atomic composition on the dosimetric response of detectors was found to be insignificant, unlike the mass density and size of the detecting material. Conclusions: The results obtained with the passive dosimeters showed that they can be used for small beam OF measurements without correction factors. The study of detector response showed that OR{sub det} is depending on the mass density, the volume averaging, and the coating effects of the detecting material. Each effect was quantified for the PTW 60016 and 60017 diodes, the micro-LiF, and the PTW 60003 diamond detectors. None of the active detectors used in this work can be recommended as a reference for small field dosimetry, but an improved diode detector with a smaller silicon chip coated with tissue-equivalent material is anticipated (by simulation) to be a reliable small field dosimetric detector in a nonequilibrium field.

07 ISOTOPE AND RADIATION SOURCES↗

Modified Monte Carlo method for study of electron transport in degenerate electron gas in the presence of electron–electron interactions, application to graphene

Standard computational methods used to take account of the Pauli Exclusion Principle into Monte Carlo (MC) simulations of electron transport in semiconductors may give unphysical results in low field regime, where obtained electron distribution function takes values exceeding unity. Modified algorithms were already proposed and allow to correctly account for electron scattering on phonons or impurities. Present paper extends this approach and proposes improved simulation scheme allowing including Pauli exclusion principle for electron–electron (e–e) scattering into MC simulations. Simulations with significantly reduced computational cost recreate correct values of the electron distribution function. Proposed algorithm is applied to study transport properties of degenerate electrons in graphene with e–e interactions. This required adapting the treatment of e–e scattering in the case of linear band dispersion relation. Hence, this part of the simulation algorithm is described in details.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Using the Monte Carlo Method to Evaluate the Reliability of Screening Multifamily Housing for Radon

When screening for radon in a multifamily housing complex using a fixed sample density (e.g., testing 1 in 10 (10%) or 1 in 4 units (25%)), the statistical confidence is dependent upon the assumed elevated radon frequency. For example, testing 25% of units in a complex estimated to have eight units with elevated radon levels will provide 90% confidence. However, if it is assumed that, in the same complex, there are only three units with elevated radon levels, the confidence drops to around 58% for the same sample density. Furthermore, in the previous example, if elevated radon levels are not found during the screening, all that can be stated is that the screening provides 90% confidence that there are no more than seven units in the complex with elevated radon levels. To more fully illustrate this uncertainty, ten separate multifamily housing radon data sets with 1 to 10 units with radon levels ≥4 pCi/L (Table 1) were selected for analysis using the Monte Carlo statistical method. Unlike other mathematically based statistical approaches, the Monte Carlo statistical method relies on repeated analysis of randomly selected data. from a 100% sampled complex at various sample densities. Success for each simulation is defined as finding at least one unit with elevated radon levels. In this statistical method, confidence in the overarching conclusion can be greatly enhanced by repeating the simulated screening hundreds or even thousands of times. For this study, each of the ten data sets was simulated 1,000 times. For each simulation, the data set was randomized three times before the fixed percentage of data was selected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A kinetic Monte Carlo method on super-lattices for the study of the defect formation in the growth of close packed structures

A modified Kinetic Lattice Monte Carlo model has been developed to predict growth rate regimes and defect formation in the case of the homo-epitaxial growth of close packed crystalline structures. The model is an improvement over standard Monte Carlo algorithms, which usually retain fixed atom positions and bond partners indicative of perfect crystal lattices. Indeed, we extend the concepts of Monte Carlo growth simulations on super-lattices containing additional sites (defect sites) with respect to those of the reference material. This extension implies a reconsideration of the energetic mapping, which is extensively presented, and allows to describe a complex phenomenology that is out of accessibility of standard stochastic approaches. Results obtained using the Kawasaki and the Bond-Counting rules for the transition probability of the Monte Carlo event are discussed in details. These results demonstrate how the defect types (local or extended), the formation mechanisms and the defect generation regimes can be characterized using our approach.

36 MATERIALS SCIENCE↗

Time series analysis and Monte Carlo methods for eigenvalue separation in neutron multiplication problems

A time series approach has been applied to the nuclear fission source distribution generated by Monte Carlo (MC) particle transport in order to calculate the non-fundamental mode eigenvalues of the system. The novel aspect is the combination of the general technical principle of projection pursuit for multivariate data with the neutron multiplication eigenvalue problem in the nuclear engineering discipline. Proof is thoroughly provided that the stationary MC process is linear to first order approximation and that it transforms into one-dimensional autoregressive processes of order one (AR(1)) via the automated choice of projection vectors. The autocorrelation coefficient of the resulting AR(1) process corresponds to the ratio of the desired mode eigenvalue to the fundamental mode eigenvalue. All modern MC codes for nuclear criticality calculate the fundamental mode eigenvalue, so the desired mode eigenvalue can be easily determined. This time series approach was tested for a variety of problems including multi-dimensional ones. Numerical results show that the time series approach has strong potential for three dimensional whole reactor core. The eigenvalue ratio can be updated in an on-the-fly manner without storing the nuclear fission source distributions at all previous iteration cycles for the mean subtraction. Lastly, the effects of degenerate eigenvalues are investigated and solutions are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adaptive stratified importance sampling: hybridization of extrapolation and importance sampling Monte Carlo methods for estimation of wind turbine extreme loads

Wind turbine extreme load estimation is especially difficult because turbulent inflow drives nonlinear turbine physics and control strategies; thus there can be huge differences in turbine response to essentially equivalent environmental conditions. The two main current approaches, extrapolation and Monte Carlo sampling, are both unsatisfying: extrapolation-based methods are dangerous because by definition they make predictions outside the range of available data, but Monte Carlo methods converge too slowly to routinely reach the desired 50-year return period estimates. Thus a search for a better method is warranted. We introduce an adaptive stratified importance sampling approach that allows for treating the choice of environmental conditions at which to run simulations as a stochastic optimization problem that minimizes the variance of unbiased estimates of extreme loads. Furthermore, the framework, built on the traditional bin-based approach used in extrapolation methods, provides a close connection between sampling and extrapolation, and thus allows the solution of the stochastic optimization (i.e., the optimal distribution of simulations in different wind speed bins) to guide and recalibrate the extrapolation. Results show that indeed this is a promising approach, as the variance of both the Monte Carlo and extrapolation estimates are reduced quickly by the adaptive procedure. We conclude, however, that due to the extreme response variability in turbine loads to the same environmental conditions, our method and any similar method quickly reaches its fundamental limits, and that therefore our efforts going forward are best spent elucidating the underlying causes of the response variability.

17 WIND ENERGY↗

Fundamental gap of fluorographene by many-body GW and fixed-node diffusion Monte Carlo methods

Fluorographene (FG) is a promising graphene-derived material with a large bandgap. Currently existing predictions of its fundamental gap (Δ f ) and optical gap (Δ opt ) significantly vary when compared with experiment. We provide here an ultimate benchmark of Δ f for FG by many-body GW and fixed-node diffusion Monte Carlo (FNDMC) methods. Both approaches independently arrive at Δf ≈ 7.1 ± 0.1 eV. In addition, the Bethe–Salpeter equation enabled us to determine the first exciton binding energy, Eb = 1.92 eV. We also point to the possible misinterpretation problem of the results obtained for gaps of solids by FNDMC with single-reference trial wave functions of Bloch orbitals. We argue why instead of Δ opt , in the thermodynamic limit,

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A modified implicit Monte Carlo method for time-dependent radiative transfer with adaptive material coupling

In this paper we develop a robust implicit Monte Carlo (IMC) algorithm based on more accurately updating the linearized equilibrium radiation energy density. The method does not introduce oscillations in the solution and has the same limit as {delta}t{yields}{infinity} as the standard Fleck and Cummings IMC method. Moreover, the approach we introduce can be trivially added to current implementations of IMC by changing the definition of the Fleck factor. Using this new method we develop an adaptive scheme that uses either standard IMC or the modified method basing the adaptation on a zero-dimensional problem solved in each cell. Numerical results demonstrate that the new method can avoid the nonphysical overheating that occurs in standard IMC when the time step is large. The method also leads to decreased noise in the material temperature at the cost of a potential increase in the radiation temperature noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Neural Network Informed Markov Chain Monte Carlo Methods

In subsurface flow modeling, quantifying the uncertainty of model parameters and the corresponding uncertainly on output quantities is a crucial task for groundwater management. Markov chain Monte Carlo (MCMC) methods can take advantage of observed data to estimate parameters in a Bayesian setting. However, MCMC can be slow to converge and produce highly correlated samples when the dimensions of the parameters is high. Using gradients for the posterior distribution can help samplers explore the parameter space more efficiently, but obtaining gradients can be computationally challenging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BACKWARD AND FORWARD MONTE CARLO METHOD IN POLARIZED RADIATIVE TRANSFER

In general, the Stocks vector cannot be calculated in reverse in the vector radiative transfer. This paper presents a novel backward and forward Monte Carlo simulation strategy to study the vector radiative transfer in the participated medium. A backward Monte Carlo process is used to calculate the ray trajectory and the endpoint of the ray. The Stocks vector is carried out by a forward Monte Carlo process. A one-dimensional graded index semi-transparent medium was presented as the physical model and the thermal emission consideration of polarization was studied in the medium. The solution process to non-scattering, isotropic scattering, and the anisotropic scattering medium, respectively, is discussed. The influence of the optical thickness and albedo on the Stocks vector are studied. The results show that the U, V-components of the apparent Stocks vector are very small, but the Q-component of the apparent Stocks vector is relatively larger, which cannot be ignored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Yttrium ENDF/B-VII Data from Theory and LANSCE/GEANIE Measurements and Covariances Estimated using Bayesian and Monte-Carlo Methods

Yttrium plays an important role as a radiochemical dosimetry detector for determining high energy 14 MeV neutron fluences, through measurement of (n,2n) activation products. The total (n,2n) cross section is known rather well from extensive activation measurements on the stable {sup 89}Y isotope, and from a previous activation measurement on the unstable {sup 88}Y ground state. However, until now the branching ratios to the ground state and excited isomers in {sup 88}Y via the {sup 89}Y (n,2n) reaction were not well known, and furthermore, uncertainty estimates were not available for these cross sections and branching ratios. This paper describes how gamma-ray transitions between states in (n,2n) and (n,n') reactions measured using the GEANIE detector at Los Alamos' LANSCE facility, together with theory predictions using the GNASH code, enable us to determine these quantities for the ENDF/B-VII evaluation. A previous measurement by Dietrich, at Livermore, provided important complementary information to the GEANIE analysis. We describe an uncertainty quantification analysis that uses the GNASH-KALMAN approach to evaluate cross sections for the {sup 89}Y (n,2n) population of the {sup 88}Y ground state and two meta-stable isomers (m1 and m2), along with their uncertainties. Our new results agree with Arthur's historic Los Alamos evaluated cross sections within a few percent below 15 MeV (with larger differences above 15 MeV). The (n,2n) cross sections to the {sup 88}Y ground state and m1, m2 isomers impact the average {sup 88}Y(n,2n){sup 87}Y cross section at leading-order; we determine this 14.1 MeV average cross section {sup 88}Y(n,2n){sup 87}Y = 1107 mb ({+-} 4%), which agrees with the value obtained from Arthur's evaluation to 0.7%. An alternative method to predict cross sections, uncertainties, and covariance data, is described that uses the European TALYS reaction modeling code and a Backward-Forward Monte-Carlo uncertainty quantification technique. This approach uses a microscopic optical model, together with Hauser-Feshbach and preequilibrium reaction mechanisms, and the underlying model parameters and their uncertainties and correlations are determined through a Monte-Carlo filtering method based on comparisons with measured cross section data. We compare the results obtained using this approach with the GNASH-KALMAN method. The evaluated cross sections are rather similar in the two approaches. We show how the uncertainty information, as embodied in the resulting covariance matrices, is also qualitatively similar in both approaches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A First-Passage Kinetic Monte Carlo method for reaction–drift–diffusion processes

Stochastic reaction–diffusion models are now a popular tool for studying physical systems in which both the explicit diffusion of molecules and noise in the chemical reaction process play important roles. The Smoluchowski diffusion-limited reaction model (SDLR) is one of several that have been used to study biological systems. Exact realizations of the underlying stochastic processes described by the SDLR model can be generated by the recently proposed First-Passage Kinetic Monte Carlo (FPKMC) method. This exactness relies on sampling analytical solutions to one and two-body diffusion equations in simplified protective domains. In this work we extend the FPKMC to allow for drift arising from fixed, background potentials. As the corresponding Fokker–Planck equations that describe the motion of each molecule can no longer be solved analytically, we develop a hybrid method that discretizes the protective domains. The discretization is chosen so that the drift–diffusion of each molecule within its protective domain is approximated by a continuous-time random walk on a lattice. New lattices are defined dynamically as the protective domains are updated, hence we will refer to our method as Dynamic Lattice FPKMC or DL-FPKMC. We focus primarily on the one-dimensional case in this manuscript, and demonstrate the numerical convergence and accuracy of our method in this case for both smooth and discontinuous potentials. We also present applications of our method, which illustrate the impact of drift on reaction kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of the direct simulation Monte Carlo method to the full shuttle geometry

A new set of programs has been developed for the application of the direct simulation Monte Carlo (or DSMC) method to rarefied gas flows with complex three-dimensional boundaries. The programs are efficient in terms of the computational load and also in terms of the effort required to set up particular cases. This efficiency is illustrated through computations of the flow about the Shuttle Orbiter. The general flow features are illustrated for altitudes from 170 to 100 km. Also, the computed lift-drag ratio during re-entry is compared with flight measurements.

Bird, G. A.↗