Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minnesota”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Some examples of deep structure of the Archean from geophysics

The development of Archean crust remains as one of the significant problems in earth science, and a major unknown concerning Archean terrains is the nature of the deep crust. The character of crust beneath granulite terrains is especially fascinating because granulites are generally interpreted to represent a deep crustal section. Magnetic data from this area can be best modeled with a magnetized wedge of older Archean rocks (granulitic gneisses) underlying the younger Archean greenstone terrain. The dip of the boundary based on magnetic modeling is the same as the dip of the postulated thrust-fault reflection. Thus several lines of evidence indicate that the younger Archean greenstone belt terrain is thrust above the ancient Minnesota Valley gneiss terrain, presumably as the greenstone belt was accreted to the gneiss terrain, so that the dipping reflection represents a suture zone. Seismic data from underneath the granulite-facies Minnesota gneiss terrain shows abundant reflections between 3 and 6 s, or about 9 to 20 km. These are arcuate or dipping multicyclic events indicative of layering.

Smithson, S. B.↗

Numerical prediction of turbulent oscillating flow and associated heat transfer

A crucial point for further development of engines is the optimization of its heat exchangers which operate under oscillatory flow conditions. It has been found that the most important thermodynamic uncertainties in the Stirling engine designs for space power are in the heat transfer between gas and metal in all engine components and in the pressure drop across the heat exchanger components. So far, performance codes cannot predict the power output of a Stirling engine reasonably enough if used for a wide variety of engines. Thus, there is a strong need for better performance codes. However, a performance code is not concerned with the details of the flow. This information must be provided externally. While analytical relationships exist for laminar oscillating flow, there has been hardly any information about transitional and turbulent oscillating flow, which could be introduced into the performance codes. In 1986, a survey by Seume and Simon revealed that most Stirling engine heat exchangers operate in the transitional and turbulent regime. Consequently, research has since focused on the unresolved issue of transitional and turbulent oscillating flow and heat transfer. Since 1988, the University of Minnesota oscillating flow facility has obtained experimental data about transitional and turbulent oscillating flow. However, since the experiments in this field are extremely difficult, lengthy, and expensive, it is advantageous to numerically simulate the flow and heat transfer accurately from first principles. Work done at the University of Minnesota on the development of such a numerical simulation is summarized.

Koehler, W. J.↗

Methane production and consumption in grassland and boreal ecosystems

The objectives of the this project were to develop a mechanistic understanding of methane production and oxidation suitable for incorporation into spatially explicit models for spatial extrapolation. Field studies were undertaken in Minnesota, Canada, and Colorado to explore the process controls over the two microbial mediated methane transformations in a range of environments. Field measurements were done in conjunction with ongoing studies in Canada (the Canadian Northern Wetlands Projects: NOWES) and in Colorado (The Shortgrass Steppe Long Term Ecological Research Project: LTER). One of the central hypotheses of the proposal was that methane production should be substrate limited, as well as being controlled by physical variables influencing microbial activity (temperature, oxidation status, and pH). Laboratory studies of peats from Canada and Minnesota (Northern and Southern Boreal) were conducted with amendments of a methanogenic substrate at multiple temperatures and at multiple pHs (the latter by titrating samples). The studies showed control by substrate, pH, and temperature in order in anaerobic samples. Field and laboratory manipulations of natural plant litter, rather than an acetogenic substrate, showed similarly large effects. The studies concluded that substrate is an important control over methanogenesis, that substrate availability in the field is closely coupled to the chemistry of the dominant vegetation influencing its decomposition rate, that most methane is produced from recent plant litter, and that landscape changes in pH are an important control, highly correlated with vegetation.

Schimel, David S.↗

Validation of Multi-Dimensional Stirling Engine Design Codes: Measurements in the 90-Degree Turn Test Section

The work to be presented herein was motivated largely by a desire to improve the understanding of oscillatory fluid mechanics inside a Stirling engine. To this end, a CFD project was undertaken at Cleveland State University with the goal of accurately predicting the fluid dynamics within an engine or engine component. Along with the CFD efforts, a code validation project was undertaken at the University of Minnesota. The material covered herein consists of four main parts. In section 1, an experimental investigation of a small aspect ratio impinging jet is discussed. Included in this discussion is a description of the test facilities and instrumentation. A presentation of the collected data is given and comments are made. Next, in section 2, a parallel experimental investigation is presented in which the same geometry as that of section 1 is used, but the flow conditions are changed from steady unidirectional flow to sinusoidally oscillating flow. In section Two, collected data are presented and comments are made. In section 3, a comparison is made between the results of sections 1 and 2, namely, sinusoidally oscillating flow results are compared to steady, unidirectional flow results from the same geometry. Finally, in section 4, a comparison is made between experimentally collected data (the main subject of this work) and CFD generated results. Furthermore, in appendix A, an introductory description of the primary measurement tool used in the experimental process the hot wire anemometer is given for the unfamiliar. The anemometer calibration procedure is described in appendix B. A portfolio of data reduction and data processing codes is provided in appendix C and lastly, a DVD and a roadmap of its contents is provided in an appendix D. 1.0 Unidirectional Flow Investigations 1.1 Introduction This unidirectional experimental program was undertaken to complement an oscillatory flow investigation conducted at the University of Minnesota. The oscillatory investigation is discussed thoroughly in section 2. We defer the description of the motivation behind these experiments until the introduction of section 2. The work that is discussed in this thesis began (chronologically) with oscillatory flow visualization experiments. It was decided that it would be valuable and important to investigate the flow under unidirectional conditions in the same geometry as that of the oscillatory experiments. The thought was that the unidirectional case would be less complicated to model with a CFD program (a moving boundary would be replaced with a steady state boundary condition). Thus, a series of unidirectional experiments were carried out to capture the important features of the flow within the test section. The purpose of these experiments was to provide a data set for comparison to CFD generated velocity fields. Hot-wire anemometry data were taken and flow visualization was conducted as a standard for code validation. The flow geometry was simple, such that it could be easily gridded in a CFD program. However, the geometry provided separation and transition zones, shear layers and recirculation zones. These characteristics made the flow complex and challenging for CFD computation. We comment that the order of experiments that produced this report is as follows: experimental flow visualization under oscillatory flow conditions was carried out; this was followed by unidirectional flow visualization and hot wire anemometry; finally, oscillatory hot wire anemometry was conducted. We present the results out of chronological order for the following reason: the unidirectional results are easier

Simon, Terrence W.↗

Extreme Thunderstorms as Seen by Satellite

Extreme events by their nature fall outside the bounds of routine experience. With imperfect or ambiguous measuring systems, it is appropriate to question whether an unusual measurement represents an extreme event or is the result of instrument errors or other sources of noise. About three weeks after the Tropical Rainfall Measuring Mission (TRMM) satellite began collecting data in Dec 1997, a thunderstorm was observed over northern Argentina with 85 GHz brightness temperatures below 50 K and 37 GHz brightness temperatures below 70 K (Zipser et al. 2006). These values are well below what had previously been observed from satellite sensors with lower resolution. The 37 GHz brightness temperatures are also well below those measured by TRMM for any other storm in the subsequent 16 years. Without corroborating evidence, it would be natural to suspect a problem with the instrument, or perhaps an irregularity with the platform during the first weeks of the satellite mission. But the TRMM satellite also carries a radar and a lightning sensor, both confirming the presence of an intense thunderstorm. The radar recorded 40+ dBZ (decibels relative to Z) reflectivity up to about 19 km altitude. More than 200 lightning flashes per minute were recorded. That same storm's 19 GHz brightness temperatures below 150 K would normally be interpreted as the result of a low-emissivity water surface (e.g., a lake, or flood waters) if not for the simultaneous measurements of such intense convection. This paper will examine records from TRMM and related satellite sensors including SSMI and AMSR-E to find the strongest signatures resulting from thunderstorms, and distinguishing those from sources of noise. The lowest brightness temperatures resulting from thunderstorms as seen by TRMM have been in Argentina in November and December. For SSMI sensors carried on five DMSP satellites examined so far, the lowest thunderstorm-related brightness temperatures have been from Argentina in November - December and from Minnesota in June-July. The Minnesota cases were associated with spotter reports of large hail, significant severe wind, and tornadoes. Those locations have the record holders for each satellite. This paper will show examples of cases with the lowest brightness temperatures, and map the locations of these and other storms with brightness temperatures nearly as low. Higher resolution data from the field program MC3E and possibly from IPHEX will be considered for context.

Cecil, Daniel J.↗

Extremely Low Passive Microwave Brightness Temperatures Due to Thunderstorms

Extreme events by their nature fall outside the bounds of routine experience. With imperfect or ambiguous measuring systems, it is appropriate to question whether an unusual measurement represents an extreme event or is the result of instrument errors or other sources of noise. About three weeks after the Tropical Rainfall Measuring Mission (TRMM) satellite began collecting data in Dec 1997, a thunderstorm was observed over northern Argentina with 85 GHz brightness temperatures below 50 K and 37 GHz brightness temperatures below 70 K (Zipser et al. 2006). These values are well below what had previously been observed from satellite sensors with lower resolution. The 37 GHz brightness temperatures are also well below those measured by TRMM for any other storm in the subsequent 16 years. Without corroborating evidence, it would be natural to suspect a problem with the instrument, or perhaps an irregularity with the platform during the first weeks of the satellite mission. Automated quality control flags or other procedures in retrieval algorithms could treat these measurements as errors, because they fall outside the expected bounds. But the TRMM satellite also carries a radar and a lightning sensor, both confirming the presence of an intense thunderstorm. The radar recorded 40+ dBZ reflectivity up to about 19 km altitude. More than 200 lightning flashes per minute were recorded. That same storm's 19 GHz brightness temperatures below 150 K would normally be interpreted as the result of a low-emissivity water surface (e.g., a lake, or flood waters) if not for the simultaneous measurements of such intense convection. This paper will examine records from TRMM and related satellite sensors including SSMI, AMSR-E, and the new GMI to find the strongest signatures resulting from thunderstorms, and distinguishing those from sources of noise. The lowest brightness temperatures resulting from thunderstorms as seen by TRMM have been in Argentina in November and December. For SSMI sensors carried on five DMSP satellites examined so far, the lowest thunderstorm-related brightness temperatures have been from Argentina in November - December and from Minnesota in June-July. The Minnesota cases were associated with spotter reports of large hail, significant severe wind, and tornadoes. Those locations have the record-holders for each satellite. The lowest AMSR-E 36.5 GHz brightness temperatures associated with deep convection have been in Argentina; the lowest 89.0 GHz brightness temperatures were from Typhoon Bolaven in the Philippine Sea. This paper will show examples of cases with the lowest brightness temperatures, and map the locations of these and other storms with brightness temperatures nearly as low. The study is largely motivated by the new GMI sensor on the Global Precipitation Mission core satellite, launched in February 2014, with its high resolution expected to reveal unprecedented low brightness temperatures when extreme events are encountered.

Cecil, Daniel J.↗

Mineralogy of Interplanetary Dust Particles from the Comet Giacobini-Zinner Dust Stream Collections

The Draconoid meteor shower, originating from comet 21P/Giacobini-Zinner, is a low-velocity Earth-crossing dust stream that had a peak anticipated flux on Oct. 8, 2012. In response to this prediction, NASA performed dedicated stratospheric dust collections to target interplanetary dust particles (IDPs) from this comet stream on Oct 15-17, 2012 [3]. Twelve dust particles from this targeted collection were allocated to our coordinated analysis team for studies of noble gas (Univ. Minnesota, Minnesota State Univ.), SXRF and Fe-XANES (SSL Berkeley) and mineralogy/isotopes (JSC). Here we report a mineralogical study of 3 IDPs from the Draconoid collection..

Nakamura-Messenger, K.↗

Defining Handling Qualities of Unmanned Aerial Systems: Phase II Final Report

Unmanned Air Systems (UAS) are no longer coming, they are here, and operators from first responders to Google and Amazon are demanding access to the National Airspace System (NAS) for a wide variety of missions. This includes a proliferation of small UAS or sUAS that will operate beyond line of sight at altitudes of 500 ft and below. A myriad of issues continues to slow the development of verification, validation, and certification methods that will enable the safe introduction of UAS to the NAS. These issues include the lack of both a consensus in UAS categorization process and quantitative certification requirements, including the definition of handling qualities. Because of the wide variety of UAS types (fixed wing, rotary wing from traditional helicopters to multirotor configurations, ducted fans, airships, etc.) and vehicle size from micro vehicles to the Global Hawk with a wing span similar to that of a Boeing 737, there cannot be a one-size-fits-all set of requirements. To address these issues, Systems Technology Inc. (STI) has developed the UAS Handling Qualities Assessment (UAS-HQ) process and corresponding draft specification that will guide UAS stakeholders through a systematic evaluation process. The work described herein builds on the existing, highly successful, military rotorcraft handling qualities specifications that features a mission-oriented approach, a concept that originated at STI. The vehicle is first identified by a simple weight-based classification and then the associated vehicle mission task elements are considered. These missions have specific tasks inclusive to them that then dictate the criteria and demonstration maneuvers necessary to evaluate the UAS handling qualities. An assessment of both modeled responses and flight test data can then be conducted to examine the predicted versus actual handling qualities and, if required, design modifications can then be made. Mr. David Klyde, Vice President and Technical Director, Engineering Services, served as Principal Investigator, while Dr. Natalia Alexandrov served as the NASA LaRC technical representative. In the Phase II program, STI was joined by David Mitchell of Mitchell Aerospace Research and the University of Minnesota. Mr. Mitchell led the draft specification development effort, while the University of Minnesota UAV Lab conducted sUAS flight tests under the direction of Dr. Peter Seiler.

Klyde, David H.↗

MN Solar Pathways: Solar Deployment Strategies-Modeling and Case Studies

As part of the Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, Clean Power Research (CPR) developed a Solar Deployment Strategies modeling tool to calculate the economic impacts and market incentives created by different solar portfolios and rate structures. CPR developed the tool using Minnesota-specific data and assumptions. The case studies described in this report provide insight into possible pathways toward the state goal of 10% solar, but the emphasis of the report is the demonstration of the tool in use cases that can be expanded and modified in future years as needs change.

14 SOLAR ENERGY↗

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory and the University of Minnesota are conducting a three-year, multipart study on residential retrofit wall assemblies. The project is funded by the U.S. Department of Energy’s Building Technology Office and will identify, test and verify wall assemblies for hygrothermal performance in retrofit applications. The study includes a comprehensive literature review and expert advisory group, which inform wall selection. Selected wall assemblies are then thermally simulated using EnergyPlus and THERM, and hygrothermally simulated using WUFI, to model both thermal and moisture performance of the wall assembly. Eight wall assemblies are then experimentally tested in an in-situ laboratory environment at the University of Minnesota, with a typical residential wall used as a baseline. The in-situ experiment looks at the physical hygrothermal performance of each assembly. The simulation and experimental results will be combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits. This paper presents progress after year one of the study. Wall system modeling and laboratory testing is scheduled to begin in November, 2019. We will discuss the parameters for wall selection and experimental design, which includes approaches to modeling and simulation, along with the physical experiment design. This paper will also outline the parameters for the techno-economic analysis, and criteria used to inform model development.

Antonopoulos, Chrissi A.↗

Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings

The Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and the University of Minnesota have been conducting a three-year study of residential retrofit wall systems. The researchers have identified, tested, and verified the hygrothermal performance of 16 wall assemblies in retrofit applications. The approach to this study includes a comprehensive literature review, the involvement of an advisory group of thermal enclosure experts, smallscale experimental in situ testing of the wall assemblies at the University of Minnesota’s Cloquet Residential Research Facility, and energy and hygrothermal simulation of wall assemblies using EnergyPlus, THERM, and WUFI. Simulation and experimental results are then combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits.This presentation summarizes the findings of this research project and is intended to guide architects and designers on how to retrofit existing wall assemblies without creating durability issues.

Desjarlais, Andre Omer↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

Vegetation Management Lessons Learned and Helpful Tools

The InSPIRE Project is investigating questions around vegetation management and agrivoltaics at solar sites across the US. Results from research at three Enel Green Power pollinator-friendly solar sites in Minnesota have shown that the success of different pollinator-friendly seed mixes depend on the ecoregion and can vary from site to site. Results from the Enel Green Power sites also showed that weed coverage decreases dramatically by three years post seeding. The InSPIRE project has also created resources like The 5 C's of Agrivoltaics and an online agrivoltaics financial calculator to help farmers, land owners, developers, and facility operators with vegetation management at solar facilities. The PV-SMaRT calculator was created by the University of Minnesota in partnership with NREL to help with questions surrounding storm-water runoff at PV sites.

agrivoltaic↗

Ionization-based search for magnetic monopoles using the NOvA Far Detector

We report a search for highly ionizing magnetic monopoles in the cosmic-ray flux using a 2713-day dataset collected during 2015–2025 with the NOvA Far Detector, a 14-kt segmented detector located on Earth’s surface in Minnesota, United States. The search is sensitive to monopoles across a wide range of speeds, 7 × 10 −4 < 𝛽 < 0.995, and is sensitive to masses as low as 2 × 10 5 GeV for the fastest monopoles. No signal was observed. With the detector’s large surface area and minimal overburden, we achieve the strongest flux limits reported to date in several regions of speed and mass. For heavy monopoles with masses above 10 13 GeV that are able to reach the detector from above or—crossing Earth—from below, we find a flux limit 𝜙 90% < 2 × 10 −16 cm −2 s −1 sr −1 (90% confidence level) for monopoles with 0.005 < 𝛽 < 0.8. Across the same range of speeds, we report a limit 𝜙 90% < 8 × 10 −16 cm −2 s −1 sr −1 for light monopoles with masses above 10 8 GeV that can reach the detector from above.

magnetic monopoles↗

Sharing the Sun: Community Solar Deployment and Subscriptions (As of January 2026)

The community solar market analysis presented here is based primarily on data collected through Sharing the Sun, an initiative of the National Community Solar Partnership+ (NCSP+). Sharing the Sun data collection and analysis are conducted by the National Laboratory of the Rockies (NLR) as part of its support for implementation of NCSP+. NLR first released a dataset of community solar projects in 2018 and updates it biannually. The January 2026 dataset, data collection methodology, and all the previous datasets are available from NLR's Data Catalog: https://data.nlr.gov/submissions/244. The dataset presents project-level information including location, capacity, operating utility, and year of interconnection. The dataset is created from multiple data sources such as utility data, public utility commissions, project developer websites, media releases, primary data collection by NLR, and data provided by developers under nondisclosure agreements. This presentation builds on a previous analysis of the community solar project dataset, Sharing the Sun: Community Solar Deployment and Subscriptions (as of June 2024). Dr. Gabriel Chan and his team at the University of Minnesota contribute to this effort. NCSP+ is led and funded by U.S. Department of Energy's Integrated Energy Systems Office (IESO).

14 SOLAR ENERGY↗

Exploring the environmental drivers of human blastomycosis cases in the Midwestern United States

Blastomycosis is a fungal infection endemic to the eastern United States (US) and Canada caused by the inhalation of the fungi Blastomyces spp. Currently, the environmental drivers of disease dynamics are poorly understood. The goal of our work was to explore what environmental conditions are associated with the annual presence of blastomycosis cases, and therefore are potentially explanatory of the ecological niche of Blastomyces. We examined the relationships between reported cases of blastomycosis in three Midwestern US states (Michigan, Minnesota, and Wisconsin) from 2007–2017 in relation to eleven hypothesized environmental conditions, including climate, stream and soil mineral content, and land cover variables. Then, we fit logistic regression models to explore the relationships between the environmental variables and yearly blastomycosis case occurrence. Mean soil moisture, stream sediment mercury content, percent of water within the county, and woody wetlands land cover were all positively associated with the presence of annual cases, with woody wetlands having the most consistent signal across the three states. We also found significant differences in the likelihood of case presence between US states that were not explained by the variables in our model, suggesting state-level differences in case reporting and disease awareness. Our results provide a perspective on potential biological hypotheses to further test regarding environmental controls on the life cycle and ecological niche of Blastomyces.

54 ENVIRONMENTAL SCIENCES↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advancing Small Business Solar Equity: Final Technical Insights Report

The Advancing Small Business Solar Equity: Final Technical Insights Report represents the culmination of two years of work in participation with Round 3 of the National Renewable Energy Laboratory's Solar Energy Innovation Network (SEIN). SEIN Round 3, titled "Equitable Solar in Underserved Communities," supported eight underserved communities across the United States in "exploring new approaches to the equitable adoption of solar energy in residential and commercial-scale settings" and in "confronting the solar barriers they face and unlocking the solar benefits most relevant to their own contexts" (National Renewable Energy Laboratory 2023). This project was one of four selected to support solar access for commercial entities in underserved communities. The research conducted for this report was done within the Minnesota Twin Cities geographic context, but certain findings and the proposed Solar Hub Network model may be found applicable nationally. Community-based organizations that serve small businesses, chambers of commerce, community development finance institutions and other community lenders, municipal governments, solar incentive providers, solar industry professionals, and others may find elements of this report useful.

14 SOLAR ENERGY↗