Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mie theory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optimization of fringe-type laser anemometers for turbine engine component testing

The fringe type laser anemometer is analyzed using the Cramer-Rao bound for the variance of the estimate of the Doppler frequency as a figure of merit. Mie scattering theory is used to calculate the Doppler signal wherein both the amplitude and phase of the scattered light are taken into account. The noise from wall scatter is calculated using the wall bidirectional reflectivity and the irradiance of the incident beams. A procedure is described to determine the optimum aperture mask for the probe volume located a given distance from a wall. The expected performance of counter type processors is also discussed in relation to the Cramer-Rao bound. Numerical examples are presented for a coaxial backscatter anemometer.

Seasholtz, R. G.↗

The formation of polar stratospheric clouds

Measurements of the stratospheric aerosol by SAM II during the northern and southern winters of 1979 showed a pronounced increase in extinction on occasions when the temperature fell to a low value (below 200 K). The correlation between extinction and temperature is evaluated on the basis of thermodynamic considerations. As the temperature falls, the hygroscopic aerosols absorb water vapor from the atmosphere, growing as they do so. The effect of the temperature on the size distribution and composition of the aerosol is determined, and the optical extinction at 1 micron wavelength is calculated using Mie scattering theory. The theoretical predictions of the change in extinction with temperature and humidity are compared with the SAM II results at 100 mb, and the water vapor mixing ratio and aerosol number density are inferred from these results. A best fit of the theoretical curves to the SAM II data gives a water vapor content of 5-6 ppmv, and a total particle number density of 6-7 particles/cu cm.

Steele, H. M.↗

Optimization of fringe-type laser anemometers for turbine engine component testing

The fringe type laser anemometer is analyzed using the Cramer-Rao bound for the variance of the estimate of the Doppler frequency as a figure of merit. Mie scattering theory is used to calculate the Doppler signal wherein both the amplitude and phase of the scattered light are taken into account. The noise from wall scatter is calculated using the wall bidirectional reflectivity and the irradiance of the incident beams. A procedure is described to determine the optimum aperture mask for the probe volume located a given distance from a wall. The expected performance of counter type processors is also discussed in relation to the Cramer-Rao bound. Numerical examples are presented for a coaxial backscatter anemometer. Previously announced in STAR as N84-25019

Seasholtz, R. G.↗

On the mean particle size and water content of polar mesospheric clouds

Results from the ultraviolet spectrometer experiment (UVS) aboard the Solar Mesospheric Explorer, which measures ultraviolet sunlight scattered from air molecules in the mesosphere, are reported and discussed. The UVS experiment, its observing modes, and details of the observing sequence are described. The data are compared with predictions of Mie scattering theory, assuming the size distribution is parameterized by a mean radius and a width parameter. The water ice content, mean particle radius, and column number are calculated as a function of cloud brightness, and in terms of the unknown width parameter. It is concluded that polar mesospheric cloud particles are quite small, having average volume-effective radii less than 70 mm, and that clouds differ in their optical properties mainly as a result of their mean particle size.

Thomas, G. E.↗

Subcentimeter-size particle distribution functions in planetary rings from Voyager radio and photopolarimeter occultation data

Analysis of measurements of the scattered and direct components of Voyager 1 radio occultation signals at 3.5 and 13 cm wavelengths yield estimates of the distribution functions of supracentimeter-size particles and thickness of relatively broad regions in Saturn's rings. If mearurements of signal amplitude at a shorter wavelength are combined with the previously analyzed data, the shape of the distribution functions characterizing the smaller particles can be constrained. If size distributions of arbitrary form were considered, many solutions are found that are consistent with the three available observations of signal amplitude. The best-fit power law was calculated to the three observations at three wavelengths for several of the embedded Saturn ringlets. Mie scattering theory predicts that the measured phase of the radio occultation signal is highly sensitive to particles ranging from 0.1 to 1.0 wavelengths in size, thus additional constraints on the subcentimeter-size distribution functions for both the Saturn and Uranus rings can in principle be derived from radio phase measurements.

Zebker, Howard A.↗

The radiation budget of stratocumulus clouds measured by tethered balloon instrumentation: Variability of flux measurements

Measurements of longwave and shortwave radiation were made using an instrument package on the NASA tethered balloon during the FIRE Marine Stratocumulus experiment. Radiation data from two pairs of pyranometers were used to obtain vertical profiles of the near-infrared and total solar fluxes through the boundary layer, while a pair of pyrgeometers supplied measurements of the longwave fluxes in the cloud layer. The radiation observations were analyzed to determine heating rates and to measure the radiative energy budget inside the stratocumulus clouds during several tethered balloon flights. The radiation fields in the cloud layer were also simulated by a two-stream radiative transfer model, which used cloud optical properties derived from microphysical measurements and Mie scattering theory.

Duda, David P.↗

Infrared spectroscopy and Mie scattering of acetylene aerosols formed in a low temperature diffusion cell

A method is described for forming and spectroscopically characterizing cryogenic aerosols formed in a low temperature gas cell. By adjusting the cell pressure, gas composition and flow rate, the size distribution of aerosol particles can be varied over a wide range. The combination of pressure and flow rate determine the residence time of the aerosols in the cell and hence the time available for the particles to grow. FTIR spectroscopy, over the range from 600/cm to 6000/cm, is used to characterize the aerosols. The particle size distribution can be varied so that, at one extreme, the spectra show only absorption features associated with the infrared active vibrational bands and, at the other, they display both absorption and Mie scattering. In the latter case, Mie scattering theory is used to obtain semiquantitative aerosol size distributions, which can be understood in terms of the interplay between nucleation and condensation. In the case of acetylene aerosols, the infrared spectra suggest that the particles exist in the high temperature cubic phase of the solid.

Dunder, T.↗

Scattering properties of natural snow and frost - Comparison with icy satellite photometry

The Hapke (1986) equation is presently fit to ascertain the single-scattering albedo of the icy satellites of Uranus and Neptune and the one-term Henyey-Greenstein particle-phase function g for each of the Middleton and Mungall (1952) goniophotometric data samples. There emerge both very high single-scattering albedos and strongly forward-scattering particle phase functions; while these are in keeping with Mie theory-based theoretical considerations, they contrast with the observed backscattering behavior of icy satellites. It is suggested the icy satellite frost grains are aggregated into particles of complex texture, which produce the unusual backscattering behavior.

Verbiscer, Anne J.↗

Calibration of the forward-scattering spectrometer probe - Modeling scattering from a multimode laser beam

Scattering calculations using a detailed model of the multimode laser beam in the forward-scattering spectrometer probe (FSSP) were carried out using a recently developed extension to Mie scattering theory. From this model, new calibration curves for the FSSP were calculated. The difference between the old calibration curves and the new ones is small for droplet diameters less than 10 microns, but the difference increases to approximately 10 percent at diameters of 50 microns. When using glass beads to calibrate the FSSP, calibration errors can be minimized by using glass beads of many different diameters, over the entire range of the FSSP. If the FSSP is calibrated using one-diameter glass beads, then the new formalism is necessary to extrapolate the calibration over the entire range.

Hovenac, Edward A.↗

On the size of particles near the nucleus of 2060 Chiron

Simultaneous dual-wavelength observations by the KAO of a recent Chiron occultation provide a measure of the relative extinction efficiencies of particles near Chiron. This observation and Mie scattering theory allow us to constrain the size of grains causing the extinction of the starlight near Chiron.

Olkin, C. B.↗

Calibration of the Forward-scattering Spectrometer Probe: Modeling Scattering from a Multimode Laser Beam

Scattering calculations using a more detailed model of the multimode laser beam in the forward-scattering spectrometer probe (FSSP) were carried out by using a recently developed extension to Mie scattering theory. From this model, new calibration curves for the FSSP were calculated. The difference between the old calibration curves and the new ones is small for droplet diameters less than 10 micrometers, but the difference increases to approximately 10% at diameters of 50 micrometers. When using glass beads to calibrate the FSSP, calibration errors can be minimized, by using glass beads of many different diameters, over the entire range of the FSSP. If the FSSP is calibrated using one-diameter glass beads, then the new formalism is necessary to extrapolate the calibration over the entire range.

Hovenac, Edward A.↗

The Optical Properties of Ion Implanted Silica

We will present our investigation on the change in the optical properties of silica, 'suprasil', after keV through MeV implantation of copper, tin, silver and gold and after annealing. Suprasil-1, name brand of silica glass produced by Hereaus Amerisil, which is chemically pure with well known optical properties. Both linear nonlinear optical properties of the implanted silica were investigated before and after thermal annealing. All implants, except for Sn, showed strong optical absorption bands in agreement with Mie's theory. We have also used Z-scan to measure the strength of the third order nonlinear optical properties of the produced thin films, which is composed of the host material and the metallic nanoclusters. For implants with a measurable optical absorption band we used Doyle's theory and the full width half maximum of the absorption band to calculate the predicted size of the formed nanoclusters at various heat treatment temperatures. These results are compared with those obtained from direct observation using transmission electron microscopic techniques.

Smith, Cydale C.↗

The Infrared Reflection Nebula Around the Protostellar System in S140

We have studied the protostellar system in S140 at 2.2, 3.1 and 3.45 microns using a 128x128 InSb array at the Lick Observatory 3m telescope. Besides the protostellar sources, the data reveal a bright infrared reflection nebula. We have developed a simple model of this region and derived the physical conditions. IRSI is surrounded by a dense dusty disk viewed almost edge-on. Photons leaking out through the poles illuminate almost directly north and south the inner edge of a surrounding shell of molecular gas, Analysis of the observed colors and intensities of the NIR light, using Mie scattering theory, reveal that the dust grains in the molecular cloud are somewhat larger than in the general diffuse interstellar medium. Moreover, the incident light has a "cool" color temperature, approximately equals 800K, and likely originates from a dust photosphere close to the protostar. Finally, we find little H2O ice associated with the dusty disk around IRSI. Most of the 3.1 micron ice extinction arises instead from cool intervening molecular cloud material. We have compared our infrared dust observations with millimeter and radio observations of molecular gas associated with this region. The large scale structure observable in the molecular gas is indicative of the interaction between the protostellar wind and the surrounding molecular cloud rather than the geometry of the protostellar disk. We conclude that S140 is a young blister formed by this outflow on the side of a molecular cloud and viewed edge-on.

Harker, D.↗

On the Calculation of Anisotropic Extinction Coefficients for Rigid Fibrous Ceramic Insulations

The specific anisotropic extinction coefficient e* couples the effective Radiative properties of a fibrous insulation into the radiation diffusion equation. This coefficient can be calculated using Mie scattering theory if fiber diameters, refractive indices and fiber orientation distributions are known. In general, fiber orientation distributions are not readily accessible and past calculations have considered fibers as either randomly distributed or normal to the heat flow direction. In certain rigid fibrous ceramic insulations neither of these cases apply well and a simple procedure is described for approximating e* from values calculated for the random and normal orientation cases. The intrinsic error associated with this scaling procedure is investigated. Numerical computations for several test structures and fiber materials show the average error to be less than 5% for net heat flux and radiation conductivity calculations.

Marshall, Jochen↗

BOREAS Aerosol Optical Depth Measurements and Atmospheric Correction

Aerosol optical depth measurements were conducted during all three Intensive Field Campaigns of BOREAS in 1994 by both groundbased and airborne tracking sun photometers. These measurements documented the highly variable aerosol loadings in the BOREAS study areas: very clear days with optical depths at 525 nm of 0.05 alternated with very hazy days (due to smoke from extensive western forest fires) with optical depths greater than 0.5. The airborne sun photometer showed the aerosol layer extended up to 3.5-4 km. Remote sensing missions were largely constrained to clear days, but some occurred under less optimum conditions. The spectral aerosol optical depths were used to derive aerosol size distributions and other aerosol optical properties useful for atmospheric correction of satellite and aircraft remote sensing imagery. Aerosol scattering phase functions and aerosol single scattering albedoes were calculated from Mie scattering theory using reasonable assumptions for the index of refraction for the aersols. Our atmospheric correction procedure Imagecor used the aerosol optical properties to derive surface radiances at each pixel from Landsat Thematic Mapper data of the southern study area on July 25, 1994. Similar efforts under FIFE showed close agreement between atmospherically corrected surface radiances and helicopter measurements of surface radiance of the same sites. Recently we incorporated calculations of the total downwelling irradiance from the 6S radiative transfer program (which vary little over the entire Landsat scene) to derive surface reflectances from the atmospherically corrected surface radiances. Tests using this procedure with both FIFE and HAPEX data sets show good agreement with ground-measured surface reflectances. Surface reflectances derived from the atmospherically corrected radiances of the July 25th Landsat scene will be compared to surface measurements made in BOREAS'southern study area.

Wrigley, R. C.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

Impact of Mineral Aerosol on TOVS Temperature and Moisture Retrievals

Mineral aerosols can absorb significant radiation in the infrared spectrum. Consequently, there may be errors in TIROS Operational Vertical Sounder (TOVS) retrieved temperature and moisture profiles in regions of heavy dust loading. We first investigate the potential error in the temperature retrievals and secondly attempt to account for radiative effects of the dust in retrievals. Information on the dust concentrations and size distribution is from the Goddard Chemistry Aerosol Transport model (GOCART). Aerosol optical parameters are calculated from mie scattering theory assuming a composition of pure illite. We used the cloud-clearing DAO TOVS retrieval system of Joiner and Rokke (2000). It is incorporated into the Data Assimilation Office (DAO) Finite Volume Data Assimilation System (NDAS). The advantage of this approach is that the first guess temperature profile used in the TOVS retrieval are forecasted temperatures from the previous assimilated time period. The operational DAO fvDAS was run for 10 days during June 2001 during a period of dust outbreaks off the coast of Africa over the Atlantic. The observed minus the forecast (O-F) brightness temperature at each TOVS channel is a measure of the accuracy of the retrieval. Since there was no account of dust during this operational run, a dependence of O-F on the estimated atmospheric dust concentrations from GOCART indicates that the dust is contaminating the TOVS retrievals. Channels that measure the surface temperature, lower tropospheric temperature and moisture show this dependence. There are errors in the retrieved brightness temperature of a half a degree or more during heavy dust loading conditions. The forecasted brightness temperature is always greater than the observed value. The radiative transfer module used in the DAO TOVS retrieval system was modified to account for dust. We calculate the sensitivity of the brightness temperature of the TOVS channels to the dust concentrations in GOCART assuming pure illite. For most channels the observed relationship between O-F and dust concentrations in GOCART is consistent with these calculated sensitivities. The fvDAS run was repeated using the modified DAO TOVS retrieval system that accounts for dust. Preliminary results from this run show that there are significant effects on the retrieved surface temperature and tropospheric moisture.

Weaver, Clark↗

Radiation Pressure Measurements on Micron Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗