Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2].

43 PARTICLE ACCELERATORS↗

Catalytic enhancement in the performance of the microscopic two-stroke heat engine

Here we consider a model of heat engine operating in the microscopic regime: the two-stroke engine. It produces work and exchanges heat in two discrete strokes that are separated in time. The working body of the engine consists of two d-level systems initialized in thermal states at two distinct temperatures. Additionally, an auxiliary nonequilibrium system called catalyst may be incorporated with the working body of the engine, provided the state of the catalyst remains unchanged after the completion of a thermodynamic cycle. This ensures that the work produced by the engine arises solely from the temperature difference. Upon establishing the rigorous thermodynamic framework, we characterize twofold improvement stemming from the inclusion of a catalyst. Firstly, we prove that in the noncatalytic scenario, the optimal efficiency of the two-stroke heat engine with a working body composed of two-level systems is given by the Otto efficiency, which can be surpassed by incorporating a catalyst with the working body. Secondly, we show that incorporating a catalyst allows the engine to operate in frequency and temperature regimes that are not accessible for noncatalytic two-stroke engines. We conclude with a general conjecture about the advantage brought by a catalyst: including the catalyst with the working body always allows to improve efficiency over the noncatalytic scenario for any microscopic two-stroke heat engines. We prove this conjecture for two-stroke engines where the working body is composed of two d-level systems initialized in thermal states at two distinct temperatures, as long as the final joint state leading to optimal efficiency in the noncatalytic scenario is not a product state, or at least one of the d-level system is not thermal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emulation of anamorphic imaging on the SHARP extreme ultraviolet mask microscope

The SHARP high-numerical aperture actinic reticle review project is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. SHARP emulates the illumination and imaging conditions of current EUV lithography scanners and those several generations into the future. An anamorphic imaging optic with increased mask-side numerical aperture (NA) in the horizontal and increased demagnification in the vertical direction has been proposed in this paper to overcome limitations of current multilayer coatings and extend EUV lithography beyond 0.33 NA. Zoneplate lenses with an anamorphic 4×/8× NA of 0.55 are fabricated and installed in the SHARP microscope to emulate anamorphic imaging. SHARP’s Fourier synthesis illuminator with a range of angles exceeding the collected solid angle of the newly designed elliptical zoneplates can produce arbitrary angular source spectra matched to anamorphic imaging. A target with anamorphic dense features down to 50-nm critical dimension is fabricated using 40 nm of nickel as the absorber. In a demonstration experiment, anamorphic imaging at 0.55 4×/8× NA and 6 deg central ray angle (CRA) is compared with conventional imaging at 0.5 4× NA and 8 deg CRA. A significant contrast loss in horizontal features is observed in the conventional images. Finally, the anamorphic images show the same image quality in the horizontal and vertical directions.

36 MATERIALS SCIENCE↗

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE↗

A Platform for Atomic Fabrication and In Situ Synthesis in a Scanning Transmission Electron Microscope

Here, the engineering of quantum materials requires the development of tools able to address various synthesis and characterization challenges. These include the establishment and refinement of growth methods, material manipulation, and defect engineering. Atomic-scale modification will be a key enabling factor for engineering quantum materials where desired phenomena are critically determined by atomic structures. Successful use of scanning transmission electron microscopes (STEMs) for atomic scale material manipulation has opened the door for a transformed view of what can be accomplished using electron-beam-based strategies. However, serious obstacles exist on the pathway from possibility to practical reality. One such obstacle is the in situ delivery of atomized material in the STEM to the region of interest for further fabrication processes. Here, progress on this front is presented with a view toward performing synthesis (deposition and growth) processes in a scanning transmission electron microscope in combination with top-down control over the reaction region. An in situ thermal deposition platform is presented, tested, and deposition and growth processes are demonstrated. In particular, it is shown that isolated Sn atoms can be evaporated from a filament and caught on the nearby sample, demonstrating atomized material delivery. This platform is envisioned to facilitate real-time atomic resolution imaging of growth processes and open new pathways toward atomic fabrication.

36 MATERIALS SCIENCE↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Microscopic entropy of AdS3 black holes revisited

A bstract We revisit the microscopic description of AdS 3 black holes in light of recent progress on their higher dimensional analogues. The grand canonical partition function that follows from the AdS 3 /CFT 2 correspondence describes BPS and nearBPS black hole thermodynamics. We formulate an entropy extremization principle that accounts for both the black hole entropy and a constraint on its charges, in close analogy with asymptotically AdS black holes in higher dimensions. We are led to interpret supersymmetric black holes as ensembles of BPS microstates satisfying a charge constraint that is not respected by individual states. This interpretation provides a microscopic understanding of the hitherto mysterious charge constraints satisfied by all BPS black holes in AdS. We also develop thermodynamics and a nAttractor mechanism of AdS 3 black holes in the nearBPS regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anti-Prostate Cancer Activity of 8-Hydroxyquinoline-2-Carboxaldehyde–Thiosemicarbazide Copper Complexes by Fluorescent Microscopic Imaging

Copper 8-hydroxyquinoline-2-carboxaldehyde–thiosemicarbazide (CuHQTS) and copper 8-hydroxyquinoline-2-carboxaldehyde–4,4-dimethyl-3-thiosemicarbazide (CuHQDMTS) are two copper thiosemicarbazone complexes with potent anticancer activity on cisplatin-resistant neuroblastoma cells. This study aimed to evaluate anti-prostate cancer activity of these two copper complexes in vitro. Both CuHQTS and CuHQDMTS inhibited proliferation of prostate cancer cells and showed cytotoxicity on prostate cancer cells carrying green fluorescent protein (GFP) by fluorescent microscopic imaging. The findings of this study demonstrated anti-prostate cancer activity of CuHQTS and CuHQDMTS and suggested that GFP-carrying prostate cancer cells might be used for testing anticancer activity of copper complexes by fluorescent microscopic imaging.

60 APPLIED LIFE SCIENCES↗

Entrainment in Superfluid Neutron-Star Crusts: Hydrodynamic Description and Microscopic Origin

In spite of the absence of viscous drag, the neutron superfluid permeating the inner crust of a neutron star cannot flow freely and is entrained by the nuclear lattice similarly to laboratory superfluid atomic gases in optical lattices. The role of entrainment on the neutron superfluid dynamics is reviewed. For this purpose, a minimal hydrodynamical model of superfluidity in neutron-star crusts is presented. This model relies on a fully 4-dimensionally covariant action principle. The equivalence of this formulation with the more traditional approach is demonstrated. In addition, the different treatments of entrainment in terms of dynamical effective masses or superfluid density are clarified. The nuclear energy density functional theory employed for the calculations of all the necessary microscopic inputs is also reviewed, focusing on superfluid properties. In particular, the microscopic origin of entrainment and the different methods to estimate its importance are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stability Considerations Using a Microscopic Stability Model Applied to a 2G Thin Film Coated Superconductor

A numerical, finite element simulation of local temperature fields, critical current and transport current distributions is applied to a 2G thin film coated high-temperature superconductor. The focus is on simulation of quenches originating from transport current locally exceeding critical current density. As in previous reports, a statistical treatment of superconductor parameters (critical temperature, current and magnetic field) is applied for this analysis; it shall take into account uncertainties possibly arising from shortcomings in conductor manufacture or during measurements of their properties. The results of the calculations are used as quasi-boundary (driving) conditions for a subsequent transient microscopic numerical stability analysis. Traditionally, stability analysis usually applies analytic stability functions that incorporate conventional, phonon-related timescales, t and disturbances. The question is whether decay of electron pairs and subsequent relaxation of the excited state to a new dynamic equilibrium carrier concentration, the “electron aspect” of the stability problem, under the same disturbances, proceeds on another timescale, t{sup ′}. Is this timescale identical to the traditional (phonon) timescale, t? If not, how large are the differences? The recently reported microscopic stability model, now applied to a thin film conductor, is consulted to find an answer to these questions. A time limit, t{sub Quench}, can be extracted from the simulations, as the time of immediate onset of a quench. This is a new approach in stability considerations since, conventionally, a temperature limit, T < T{sub Crit}, is set as stability criterion. If electrical operation or cooling conditions cannot immediately respond to this challenge, the thin film superconductor, if this time limit is exceeded, will hardly be able to return to zero loss current transport.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of Confocal Microscope for Environmental Tensile Mechanical Testing

Mechanical testing in environmental chambers is typically limited to 450°C. Some specialty chambers have been designed but at a high cost. Furthermore, accurate extensometers in environmental chambers are rare and expensive to operate. A unique solution investigated in this manuscript is the mating of a confocal laser scanning microscope with a sealed environmental chamber fitted with loading clevises for mechanical testing. Such a setup allows the researcher to measure strain data at elevated temperatures in controlled environments. Utilizing a laser light source avoids problems with blackbody radiation at elevated temperatures. Setup and accuracy of the microscope are discussed concerning tensile loading. P91 boiler steel was selected for this work because of the long history of the alloy in the fossil energy industry. Optical strain uncertainty was measured between 1.6% and 3.5%. Here, other tensile parameters were satisfactorily measured within the experimental error of larger standard specimens.

36 MATERIALS SCIENCE↗

Deployment of neural-network-based neutron microscopic cross sections in the Griffin reactor physics application

The capability to utilize neural networks to predict macroscopic and microscopic cross section parametric spaces has been developed for the Griffin reactor physics application. The LibTorch interface enables Griffin's MOOSE-based materials to interact with LibTorch-trained models, allowing for the evaluation of complex macroscopic or microscopic cross section spaces, which are then used to evaluate the neutronic properties of the Griffin finite element model. This study benchmarks traditional ISOXML-formatted tabulation libraries against neural network-based models for 279 nuclides on 20,160 grid points for zero-dimensional and two-dimensional reactor models. Benchmark metrics include the fundamental mode eigenvalue, fission and absorption rates, and various temperature coefficients of reactivity (isothermal, fuel, and moderator). From the perspective of storage space, the complete set of LibTorch models uses 11 MB on disk, compared to the 10 GB for the ISOXML multigroup library that covers the same grid space. For the two-dimensional performance case considered in Griffin, the Torch model uses 97% less RAM than the reference ISOXML dataset while runtime increases by a factor of 3 when using the LibTorch model compared to the ISOXML dataset with multi-linear interpolation. The LibTorch model consistently yields errors within 0.01% for most analyzed quantities except for the temperature coefficients of reactivity where the maximum discrepancies are up to 0.3 $\frac{pcm}{K}$. Due to the neural network attempting to best predict quantities with no regard for a positive or negative bias for any given quantity, predictions may experience random fluctuations, resulting in both positive and negative errors. Future work will entail both depletion and coupled transient analysis to determine the predictive capabilities of Griffin with neural network-based cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Combining disdrometer, microscopic photography, and cloud radar to study distributions of hydrometeor types, size and fall velocity

Addressing solid precipitation poses additional challenges compared to warm rain due to complex hydrometeor shapes involved, including the dependence of fall velocity on hydrometeor sizes, hydrometeor size distributions, and hydrometeor classification. This study is an extension of our previous work (Niu et al., 2010) to address these challenges by combining measurements from a PARSIVEL disdrometer, microscope photography, and millimeter wavelength cloud radar. The combined measurements are analyzed to classify the precipitation hydrometeor types, examine the dependence of fall velocity on hydrometeor sizes for different hydrometeor types, and determine the best distributions to describe the hydrometeor size distributions of different hydrometeor types. The results show: (1) Hydrometeors can be classified to four main types of raindrop, graupel, snowflake and mixed-phase according to the dependence of terminal velocity on particle sizes, corresponding microscope photos and cloud radar observations; (2) There are significant scatters in fall velocity for a given hydrometer size velocities, and the fall velocity spread for the solid hydrometeors appear wider than that for raindrops across hydrometeor sizes, with that for the mixed-phase precipitation being largest, suggesting that the effects of hydrometeor shape on hydrometeor fall velocities; (3) Hydrometeor size distributions for the four types can all be well described by the Gamma or Weibull distribution; Weibull (Gamma) distribution performs better when skewness is less (larger) than 2.

54 ENVIRONMENTAL SCIENCES↗

Hydration level dependence of the microscopic dynamics of water adsorbed in ultramicroporous carbon

Even when not functionalized intentionally, most carbon materials are not hydrophobic and readily adsorb water molecules from atmospheric water vapor. We have equilibrated an ultramicroporous carbon at several levels of relative humidity, thereby attaining various hydration levels. The water molecules were adsorbed on the pore walls (but did not fill completely the pore volume) and thus could be better described as hydration, or surface, rather than confined, water. We used quasielastic neutron scattering to perform a detailed investigation of the dependence of microscopic dynamics of these adsorbed water species on the hydration level and temperature. The behavior of hydration water in ultramicroporous carbon clearly demonstrates the same universal traits that characterize surface (hydration) water in other materials that are surface-hydrated. In addition, unless special treatment is intentionally applied to ultramicroporous carbon, the species filling its pores in various applications, ranging from hydrogen molecules to electrolytes, likely find themselves in contact with non-freezing water molecules characterized by rich microscopic dynamics.

36 MATERIALS SCIENCE↗

Computational design of microscopic swimmers and capsules: From directed motion to collective behavior

Systems of motile microscopic particles can exhibit behaviors that resemble those of living microorganisms, including cooperative motion, self-organization, and adaptability to changing environments. Using mesoscale computational modeling, we design synthetic microswimmers and microcapsules that undergo controllable, self-propelled motion in solution. Stimuli-responsive hydrogels are used to actuate the microswimmers and to enable their navigation and chemotaxing behavior. The self-propelled motion of microcapsules on solid surfaces is achieved by the release of encapsulated solutes that alter the surface adhesiveness. These signaling solutes also enable interactions among multiple microcapsules that lead to complex, cooperative behavior. Our findings provide guidelines for creating microscopic devices and machines able to autonomously move and mimic the communication and chemotaxis of biological microorganisms.

42 ENGINEERING↗