Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Isotopic discrepancy in microscopic fusion of 16 O + 40,48 Ca

We present a detailed comparison of fusion in 16 O + 40,48 Ca within a fully microscopic time-dependent Hartree-Fock framework over sub-, near-, and above-barrier energies. While 16 O + 40 Ca fusion cross sections are reproduced within the available experimental energy range, calculations for the neutron-rich 16 O + 48 Ca system systematically overestimate the measured near-barrier cross sections. The discrepancy persists across the tested energy density functionals, indicating that it is not tied to a particular parametrization. Analysis of the dynamical interaction potentials reveals an outward shift and softening of the barrier region at the lowest collision energies. These results are then compared to a frozen density description where the barrier modifications are absent and the predicted cross sections are brought closer to experiment. Here, this demonstrates that the observed discrepancy is closely linked to dynamical surface rearrangement and isovector effects, and highlights the sensitivity of low-energy fusion to both the structure and dynamics of neutron-rich nuclei. This suggests that limitations in the isovector sector of conventional Skyrme EDFs in describing the structure of 48 Ca, as highlighted by CREX, are also manifested in the fusion dynamics of the 16 O + 48 Ca system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic optical potentials from a Green's function approach

Optical potentials are a standard tool in the study of nuclear reactions, as they describe the interaction between a target nucleus and a projectile. The use of phenomenological optical potentials built using experimental data on stable isotopes is widespread. Although successful in their dedicated domain, it is unclear whether these phenomenological potentials can provide reliable predictions for unstable isotopes. To address this problem, optical potentials based on microscopic nuclear structure input calculations prove to be crucial and are an important current line of research. In this work we present an explicit implementation of the Feshbach formalism for the systematic derivation of optical potentials using input from nuclear structure models. Numerical tools for the derivation of Green's functions associated with nonlocal potentials are presented. In conclusion, the new optical potential, based on the valence shell model, is applied to the calculations of 𝑛 + 24 Mg elastic scattering and yields a close agreement with the experimental data.

Direct reactions↗

Microwave microscope studies of trapped vortex dynamics in superconductors

Trapped vortices in superconductors introduce residual resistance in superconducting radio-frequency (SRF) cavities and disrupt the operation of superconducting quantum and digital electronic circuits. Understanding the detailed dynamics of trapped vortices under oscillating magnetic fields is essential for advancing these technologies. We have developed a near-field magnetic microwave microscope to study the dynamics of a limited number of trapped vortices under the probe when stimulated by a localized rf magnetic field. By measuring the local second-harmonic response (𝑃 2⁢f ) at subfemto-Watt levels, we isolate signals exclusively arising from trapped vortices, excluding contributions from surface defects and Meissner screening currents. Toy models of niobium superconductor hosting vortex pinning sites are introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe/sample interaction to better understand the measured second-harmonic response. The simulation results demonstrate that the second-harmonic response of trapped vortex motion under a localized rf magnetic field shares key features with the experimental data. Here, this measurement technique provides access to vortex dynamics at the micrometer scale, such as depinning events and spatially resolved pinning properties, as demonstrated in measurements on a niobium film with an antidot flux pinning array.

43 PARTICLE ACCELERATORS↗

Connecting relativistic density functional theory to microscopic calculations

The development of systematic effective field theories (EFTs) for nuclear forces and advances in solving the nuclear many-body problem have greatly improved our understanding of dense nuclear matter and the structure of finite nuclei. For global nuclear calculations, density functional theories (DFTs) have been developed to reduce the complexity and computational cost required in describing nuclear systems. However, DFT often makes approximations and assumptions about terms included in the functional, which may introduce systematic uncertainties compared to microscopic calculations using EFTs. In this work, we investigate possible avenues of improving nuclear DFT using nonlinear relativistic mean-field (RMF) theory. We explore the impact of RMF model extensions by fitting the nonlinear RMF model to predictions of nuclear matter and selected closed-shell nuclei using four successful chiral EFT Hamiltonians. We find that these model extensions are impactful and important in capturing the physics present within chiral Hamiltonians, particularly for charge radii and neutron skins of closed-shell nuclei. However, there are additional effects that are not captured within the RMF model, particularly within the isoscalar sector of RMF theory. Additional model extensions and the reliability of the nonlinear RMF model are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

A Systematic Comparison for Consistent Scenario Development Using Microscopic Simulation Software

This study aims to explore a methodology that enables the development of consistent traffic micro simulation for emerging traffic and vehicle control technologies for improved mobility and energy efficiency across different modeling platforms. Researchers might study the same application on different platforms and have the need to benchmark across platforms. However, there lacks a systematic study on simulation software comparison, especially for emerging mobility and energy efficiency applications. For this, a systematic scenario development and evaluation approach is presented and demonstrated to compare scenarios generated in different traffic microsimulation platforms. Network-level and vehicle-level trip performance results of the traffic scenario are evaluated in three microscopic simulation platforms - VISSIM, AIMSUN, and SUMO. The results indicate that the network-level performance is consistent among the three software suites except when the demand is high, where the energy consumption performance varies.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

Atomic precision imaging with an on-chip scanning tunneling microscope integrated into a commercial ultrahigh vacuum STM system

In this article, we replace the Z axis of the piezotube of a conventional Ultrahigh-Vacuum (UHV) Scanning Tunneling Microscope (STM) with a one-degree-of-freedom Microelectromechanical-System (MEMS) nanopositioner. As a result, a hybrid system is realized in which motions in the XY plane are carried out by the piezotube, while the MEMS device performs the Z-axis positioning with a smaller footprint and higher sensitivity. With the proposed system and a feedback loop, STM imaging is conducted on an H-passivated Si (100)-2×1 sample in a UHV condition, demonstrating that this on-chip STM is conducive to atomic precision scanning tunneling microscopy.

Engineering↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Three-dimensional super line-localization in low signal-to-noise microscope images via prior-apprised unsupervised learning (PAUL)

Biological processes such as processive enzyme turnover and intracellular cargo tracking involve the dynamic motion of a small "article" along a curvilinear biopolymer track. To understand these processes that occur across multiple length and time scales, one must acquire both the trajectory of the particle and the position of the track along which it moves, possibly by combining high-resolution single-particle tracking with conventional microscopy. Yet, usually there is a significant resolution mismatch between these modalities: while the tracked particle is localized with a precision of 10 nm, the image of the surroundings is limited by optical difraction, with 200 nm lateral and 500 nm axial resolutions. Compared to the particle's trajectory, the surrounding curvilinear structure appears as a blurred and noisy image. This disparity in the spatial resolutions of the particle trajectory and the surrounding curvilinear structure image makes data reconstruction, as well as interpretation, particularly challenging. Analysis is further complicated when the curvilinear structures are oriented arbitrarily in 3D space. Here, we present a prior-apprised unsupervised learning (PAUL) approach to extract information from 3D images where the underlying features resemble a curved line such as a filament or microtubule. This three-stage framework starts with a Hessian-based feature enhancement, which is followed by feature registration, where local line segments are detected on repetitively sampled subimage tiles. In the final stage, statistical learning, segments are clustered based on their geometric relationships. Principal curves are then approximated from each segment group via statistical tools including principal component analysis, bootstrap and kernel transformation. This procedure is characterized on simulated images, where sub-voxel medium deviations from true curves have been achieved. The 3D PAUL approach has also been implemented for successful line localization in experimental 3D images of gold nanowires obtained using a multifocal microscope. Lastly, this work not only bridges the resolution gap between two microscopy modalities, but also allows us to conduct 3D super line-localization imaging experiments, without using super-resolution techniques.

42 ENGINEERING↗

Modified Data Collection And Analysis Codes Of Using Tcm (thermal Conductivity Microscope) To Measure Thermal Conductivity And Diffusivity

The "data collection" basically involves setting up the thermal wave frequency, laser scan distance, and other parameters related to the experimental setup. The modification of this code is minor and the details of this code can be found in the earlier patent ("thermal conductivity microscope"). The "data analysis" instead, replaces the simplified analytical model by a more complete analytical model, and used a "thermoquadruple" method to solve the analytical model. The efficiency is orders of magnitude improved and the accuracy is also better. Meanwhile, the previous model can only handle a two-layer sample structure. The new, complete model can handle materials with multiple layers (any given number), which is necessary to handle post ion irradiated materials.

Hua, Zilong [Idaho National Laboratory (INL), Idah↗

Major to trace element imaging and analysis of iron age glasses using stage scanning in the analytical dual beam microscope (tandem)

Dark and clear silicate glasses formed during an iron age vitrification event ≈ 1500 years ago at the Broborg hillfort near Uppsala, Sweden have been analyzed using a scanning electron microscope equipped with a micro-X-ray fluorescence (μXRF) spectrometer. Correlated µXRF and electron beam-induced energy dispersive spectrometry (EDS) X-ray maps were collected via stage-scanning at constant velocity. This coupled procedure represents a new approach for the cultural heritage community to conduct analytical studies of archaeometric specimens composed of metal, ceramic, or mixed inorganic/organic materials, where major and trace element compositions are registered in space for areas up to the centimeter-length scale at micrometer-scale resolution. Overview images were used to select areas for EDS beam scan maps correlated with multispectral cathodoluminescence (CL) imaging and co-located quantitative EDS and μXRF point analysis. Fe, Ca, Mg, Ti, P, Mn, Zr, Zn, and Y are enriched in the dark glass, while Si, Al, K, Na, Ba, Sr, Rb, and Ga are enriched in the clear glass. Unmelted material is comprised predominately of quartz (SiO 2 ) along with trace apatite (Ca 5 (PO 4 ) 3 [Cl,OH]) and zircon (ZrSiO 4 ). Multivariate statistical analysis was used to measure the area fractions of high variance components while lower variance components represented phase mixtures. Differences between calculated melt viscosities for the glass compositions are consistent with field and laboratory observations. Coupled large area EDS and μXRF imaging shows significant promise for informed selection of higher spatial resolution and higher sensitivity follow-up studies, e.g., those performed using synchrotron analysis.

36 MATERIALS SCIENCE↗

Particle velocity measurement within a free-falling particle curtain using microscopic shadow velocimetry

We report an optical method for particle velocity measurement that is suitable for the measurement of particle velocities within dense particle-laden flows with high spatial resolution. The technique is based on particle shadow velocimetry with the use of a long-distance microscopic lens for images collection. The narrow depth of field of the lens allows particles within the focal plane to have much higher pattern intensities than those outside it on the collected images. Data processing was then employed to remove particles from outside the focal plane based on the gradient of the signal and a threshold. Following this, particle velocity was calculated from two successive images in the usual way. The technique was successfully demonstrated in a free-falling particle curtain with volume fractions in the four-way coupling regime of near-spherical micro-particles falling under gravity. The method was successfully employed to measure the transverse velocity profile through the curtain, which is the first time that such a measurement has been performed. Other highly-fidelity experimental data, which is also well suited to model development and validation, include the particle mass flow rate, curtain thickness and opacity.

Han, Shipu (ORCID:0000000278545882)↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

3D quantum ghost imaging microscope

Quantum ghost imaging uses quantum-entangled photons to generate a two-dimensional image with only a bucket detector at the sample. Here we expand on this approach to generate a three-dimensional image without scanning. A quantum-entangled light source directly links information between a pair of 2D sensors, one of which captures a standard image from one perspective and a second sensor which captures a ghost image from a perpendicular perspective. By correlating the spatial information from the two detectors for each photon pair, we obtain three dimensions of spatial information (x, y, and z) for each scattered photon. We demonstrate that this system can study microscopic environments by imaging scattering from metallic nanoparticle clusters. This approach has the potential to greatly reduce the flux of light required to obtain a 3D image of a biological sample and thereby extend the number of images that can be obtained before photodamaging the sample.

Eshun, Audrey [Lawrence Livermore National Laborat↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

43 PARTICLE ACCELERATORS↗