Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NASA's program in lidar remote sensing

Several major NASA research efforts in lidar remote sensing are reviewed, with attention given to hardware and key sensor issues along with results and expectations. The discussion covers temperature and pressure measurements, measurements methods and instrumentation, pressure data, wind field measurements, atmospheric backscatter measurement, aerosol and cloud measurements, and water vapor measurement. Consideration is also given to the applicability of lidar measurements to problems of operational weather analysis and forecasting, climate studies, mesoscale and severe storm analysis and forecastig, and studies of atmosphere/surface interface.

Theon, John S.↗

Spectroscopic investigation of a low-power arcjet plume

We report the results of spectroscopic measurements on the exhaust plume from a 1 kW NASA Lewis arcjet operated on simulated ammonia. In particular, we analyze emissions from the Balmer lines of atomic hydrogen and from one of the rotational bands of the NH radical. We find that exit plane temperatures are in the range 2000 to 3500 K, depending on the measurement method, and that the electron density upstream of the exit plane is on the order of 1.5 x 10 exp 14/cu cm as determined by the Stark width of the Balmer-alpha line. Also, we have determined that the average velocity of atomic hydrogen at the exit plane is about 4 km/sec, and that strong acceleration (to 5.5 km/sec) of the flow occurs just beyond the exit plane.

Ruyten, W. M.↗

Pressure and temperature measurement in supercharger investigations

With the further development of the supercharger, requirements with regard to measuring accuracy increase while at the same time the conditions under which the measurements must be carried out become more difficult. The present paper is a contribution toward the improvement and refinement of the measuring methods. For pressure measurements some suggestions are made with regard to design and location of the measuring stations. The question of temperature measurement in rapid air flow is discussed, new instruments for the direct measurement of the temperature in the rapid airstream are described and the results obtained with the various instruments presented.

Franz, A↗

Experiments on a Slotted Wing

The results of pressure distribution measurements that were made on a model wing section of a Fieseler F 5 R type airplane are presented. Comparison of those model tests with the corresponding flight tests indicates the limitations and also the advantages of wind tunnel investigations, the advantages being particularly that through the variety of measuring methods employed the more complicated flow conditions may also be clarified. A fact brought out in these tests is that even in the case of "well rounded" slots it is possible for a vortex to be set up at the slot entrance and this vortex is responsible for certain irregularities in the pressure distribution and in the efficiency of the slot.

Ruden, P↗

Two color holographic interferometry for microgravity application

Holographic interferometry is a primary candidate for the measurement of temperature and concentration in various crystal growth experiments destined for space. The method measures refractive index changes in the experiment test cell. A refractive index change can be caused by concentration changes, temperature changes, or a combination of temperature and concentration changes. If the refractive index changes are caused by temperature and concentration changes occurring simultaneously in the experiment test cell, the contributions by the two effects cannot be separated by conventional measurement methods. By using two wavelengths, two independent interferograms can be produced from the reconstruction of the hologram. The two interferograms will be different due to dispersion properties of fluid materials. These differences provide the additional information that allows the separation of simultaneously occurring temperature and concentration gradients. There is no other technique available that can provide this type of information. The primary objectives of this effort are to experimentally verify the mathematical theory of two color holographic interferometry and to determine the practical value of this technique for space application. To achieve these objectives, the accuracy and sensitivity of the technique must be determined for geometry's and materials that are relevant to the Materials Processing in the Space program of NASA. This will be achieved through the use of a specially designed two-color holographic interferometry breadboard optical system. In addition to experiments to achieve the primary goals, the breadboard will also provide inputs to the design of an optimum space flight system.

Trolinger, James D.↗

Figures of merit for laser beam quality

It was shown how full-width at half maximum (FWHM), full-width at 1/e(sup 2) (FW1/e(sup 2)), Strehl ratio, and encircled energy figures of merit vary with different types of aberration and measurement methods. The array sampling method and the slit-scan method are examined in detail. Our irradiance in the exit pupil of the optical system is a simple gaussian. It was found that in general the slit-scan method and the array method do not yield the same result. The width measurements for the central lobe of the diffraction pattern are very insensitive to aberration.

Milster, T. D.↗

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan↗

Strain gage selection in loads equations using a genetic algorithm

Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

Source record↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Mark Tracking: Position/orientation measurements using 4-circle mark and its tracking experiments

Future space robots require position and orientation tracking with visual feedback control to track and capture floating objects and satellites. We developed a four-circle mark that is useful for this purpose. With this mark, four geometric center positions as feature points can be extracted from the mark by simple image processing. We also developed a position and orientation measurement method that uses the four feature points in our mark. The mark gave good enough image measurement accuracy to let space robots approach and contact objects. A visual feedback control system using this mark enabled a robot arm to track a target object accurately. The control system was able to tolerate a time delay of 2 seconds.

Kanda, Shinji↗

An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

Gregory, Gerald L.↗

Verification of a three-dimensional resin transfer molding process simulation model

Experimental evidence was obtained to complete the verification of the parameters needed for input to a three-dimensional finite element model simulating the resin flow and cure through an orthotropic fabric preform. The material characterizations completed include resin kinetics and viscosity models, as well as preform permeability and compaction models. The steady-state and advancing front permeability measurement methods are compared. The results indicate that both methods yield similar permeabilities for a plain weave, bi-axial fiberglass fabric. Also, a method to determine principal directions and permeabilities is discussed and results are shown for a multi-axial warp knit preform. The flow of resin through a blade-stiffened preform was modeled and experiments were completed to verify the results. The predicted inlet pressure was approximately 65% of the measured value. A parametric study was performed to explain differences in measured and predicted flow front advancement and inlet pressures. Furthermore, PR-500 epoxy resin/IM7 8HS carbon fabric flat panels were fabricated by the Resin Transfer Molding process. Tests were completed utilizing both perimeter injection and center-port injection as resin inlet boundary conditions. The mold was instrumented with FDEMS sensors, pressure transducers, and thermocouples to monitor the process conditions. Results include a comparison of predicted and measured inlet pressures and flow front position. For the perimeter injection case, the measured inlet pressure and flow front results compared well to the predicted results. The results of the center-port injection case showed that the predicted inlet pressure was approximately 50% of the measured inlet pressure. Also, measured flow front position data did not agree well with the predicted results. Possible reasons for error include fiber deformation at the resin inlet and a lag in FDEMS sensor wet-out due to low mold pressures.

Fingerson, John C.↗

The Pressure Sensitive Paint Method: An Overview

Pressure sensitive paint (PSP) is a relatively new aerodynamic measurement method with the unique capability of providing a field measurement of pressure over a test surface. This presentation provides an introductory description of this technology based on a review of the open literature. It confines itself to the application of the method to aircraft development wind tunnel testing, at present the primary application area and thus research focus of the method. Described are PSP fundamentals, the various technology elements comprising PSP technology, and current limitations and considerations in applying the technology. Experimental results are presented to illustrate the present capability of the method.

McLachlan, B. G.↗

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL↗

Researches on the Piston Ring

In internal combustion engines, steam engines, air compressors, and so forth, the piston ring plays an important role. Especially, the recent development of Diesel engines which require a high compression pressure for their working, makes, nowadays, the packing action of the piston ring far more important than ever. Though a number of papers have been published in regard to researches on the problem of the piston ring, none has yet dealt with an exact measurement of pressure exerted on the cylinder wall at any given point of the ring. The only paper that can be traced on this subject so far is Mr. Nakagawa's report on the determination of the relative distribution of pressure on the cylinder wall, but the measuring method adopted therein appears to need further consideration. No exact idea has yet been obtained as to how the obturation of gas between the piston and cylinder, the frictional resistance of the piston, and the wear of the cylinder wall are affected by the intensity and the distribution of the radial pressure of the piston ring. Consequently, the author has endeavored, by employing an apparatus of his own invention, to get an exact determination of the pressure distribution of the piston ring. By means of a newly devised ring tester, to which piezoelectricity of quartz was applied, the distribution of the radial pressure of many sample rings on the market was accurately determined. Since many famous piston rings show very irregular pressure distribution, the author investigated and achieved a manufacturing process of the piston ring which will exert uniform pressure on the cylinder wall. Temperature effects on the configuration and on the mean spring power have also been studied. Further, the tests were performed to ascertain how the gas tightness of the piston ring may be affected by the number or spring power. The researches as to the frictional resistance between the piston ring and the cylinder wall were carried out, too. The procedure of study, and experiments conducted by the author, on this subject will be fully described in the following paragraphs.

Ehihara, Keikiti↗

Software Reliability Measurement Experience

In this chapter, we describe a recent study of software reliability measurement methods that was conducted at the Jet Propulsion Laboratory. The first section of the chapter, sections 8.1, summarizes the study, characterizes the participating projects, describes the available data, and summarizes the tudy's results.

Software data execution-based early prediction↗

Measurement of Density, Sound Velocity, Surface Tension, and Viscosity of Freely Suspended Supercooled Liquids

Non-contact methods have been implemented in conjunction with levitation techniques to carry out the measurement of the macroscopic properties of liquids significantly cooled below their nominal melting point. Free suspension of the sample and remote methods allow the deep excursion into the metastable liquid state and the determination of its thermophysical properties. We used this approach to investigate common substances such as water, o-terphenyl, succinonitrile, as well as higher temperature melts such as molten indium, aluminum and other metals. Although these techniques have thus far involved ultrasonic, electromagnetic, and more recently electrostatic levitation, we restrict our attention to ultrasonic methods in this paper. The resulting magnitude of maximum thermal supercooling achieved have ranged between 10 and 15% of the absolute temperature of the melting point for the materials mentioned above. The physical properties measurement methods have been mostly novel approaches, and the typical accuracy achieved have not yet matched their standard equivalent techniques involving contained samples and invasive probing. They are currently being refined, however, as the levitation techniques become more widespread, and as we gain a better understanding of the physics of levitated liquid samples.

Supercooling Liquids↗

Detection of S02 and N02 in Stack Plume by Raman Scattering and Fluorescence

We have been studying laser-Raman radar which can be used as the remote detector of sulfur dioxide concentration in the stack plume of boiler exhaust gas, and some results have been published. In this paper, we report the interference of nitrogen dioxide fluorescence against sulfur dioxide Raman scattering and the measuring method of sulfur dioxide and nitrogen dioxide concentration. In a stack plume, high density dust and high concentration carbon dioxide are included, therefore very strong Mie back-scattering and carbon dioxide Raman scattering are observed. The separation of these scattering signals from sulfur dioxide Raman signal was the first problem for the laser-Raman radar. But, this problem was solved by using the filter which have high resolving power. It is well known that nitrogen dioxide can be excited to emit fluorescence of broad spectrum by blue-green light. The light source of the laser-Raman radar is SH of Nd:YAG laser, and boiler exhaust gas includes several tens ppm of nitrogen dioxide, then the interference of nitrogen dioxide fluorescence brings the error to sulfur dioxide measurement. 'rhe rejection of the interference can be achieved by the subtraction of the nitrogen dioxide fluorescence contribution from detected signal at sulfur dioxide Raman scattering wavelength. The nitrogen dioxide fluorescence contribution can be measured by two methods. The first is to convert the nitrogen dioxide fluorescence intensity which is measured at a different wavelength from sulfur dioxide Raman line into the one at sulfur dioxide Raman line. The second is to convert the detected signal intensity, which is obtained when the range gate is set just behind the plume, into the one obtained at the range of the plume using the difference of the time dependence between sulfur dioxide Raman scattering and nitrogen dioxide fluorescence. Nitrogen dioxide fluorescence has lifetime of about 300nS, while Raman scattering has none. By either of the two methods, the contribution of nitrogen dioxide fluorescence is determined. Then, we can measure the nitrogen dioxide and sulfur dioxide concentration.The minimum detectable concentration and the experimental results of the remote sensing of sulfur dioxide and nitrogen dioxide in stack plume will be discussed in detail.

Nakahara, S.↗