Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements

The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.

Menyuk, N.↗

Analysis of Jupiter's Oval BA: A Streamlined Approach

We present a novel method of constructing streamlines to derive wind speeds within jovian vortices and demonstrate its application to Oval BA for 2001 pre-reddened Cassini flyby data, 2007 post-reddened New Horizons flyby data, and 1998 Galileo data of precursor Oval DE. Our method, while automated, attempts to combine the advantages of both automated and manual cloud tracking methods. The southern maximum wind speed of Oval BA does not show significant changes between these data sets to within our measurement uncertainty. The northern maximum dries appear to have increased in strength during this time interval, tvhich likely correlates with the oval's return to a symmetric shape. We demonstrate how the use of closed streamlines can provide measurements of vorticity averaged over the encircled area with no a priori assumptions concerning oval shape. We find increased averaged interior vorticity between pre- and post-reddened Oval BA, with the precursor Oval DE occupying a middle value of vorticity between these two.

Sussman, Michael G.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm-diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Temperature-Dependent Refractive Index Measurements of L-BBH2 Glass for the Subaru CHARIS Integral Field Spectrograph

Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 micron. We report absolute refractive index (n), dispersion (dn/d(lambda), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.

geometrical optics↗

Fabry-Perot interferometer measurement of static temperature and velocity for ASTOVL model tests

A spectrally resolved Rayleigh/Mie scattering diagnostic was developed to measure temperature and wing-spanwise velocity in the vicinity of an ASTOVL aircraft model in the Lewis 9 x 15 Low Speed Wind Tunnel. The spectrum of argon-ion laser light scattered by the air molecules and particles in the flow was resolved with a Fabry-Perot interferometer. Temperature was extracted from the spectral width of the Rayleigh scattering component, and spanwise gas velocity from the gross spectral shift. Nozzle temperature approached 800 K, and the velocity component approached 30 m/s. The measurement uncertainty was about 5 percent for the gas temperature, and about 10 m/s for the velocity. The large difference in the spectral width of the Mie scattering from particles and the Rayleigh scattering from gas molecules allowed the gas temperature to be measured in flow containing both naturally occurring dust and LDV seed (both were present).

Kourous, Helen E.↗

A Framework for Propagation of Uncertainties in the Kepler Data Analysis Pipeline

The Kepler space telescope is designed to detect Earth-like planets around Sun-like stars using transit photometry by simultaneously observing 100,000 stellar targets nearly continuously over a three and a half year period. The 96-megapixel focal plane consists of 42 charge-coupled devices (CCD) each containing two 1024 x 1100 pixel arrays. Cross-correlations between calibrated pixels are introduced by common calibrations performed on each CCD requiring downstream data products access to the calibrated pixel covariance matrix in order to properly estimate uncertainties. The prohibitively large covariance matrices corresponding to the ~75,000 calibrated pixels per CCD preclude calculating and storing the covariance in standard lock-step fashion. We present a novel framework used to implement standard propagation of uncertainties (POU) in the Kepler Science Operations Center (SOC) data processing pipeline. The POU framework captures the variance of the raw pixel data and the kernel of each subsequent calibration transformation allowing the full covariance matrix of any subset of calibrated pixels to be recalled on-the-fly at any step in the calibration process. Singular value decomposition (SVD) is used to compress and low-pass filter the raw uncertainty data as well as any data dependent kernels. The combination of POU framework and SVD compression provide downstream consumers of the calibrated pixel data access to the full covariance matrix of any subset of the calibrated pixels traceable to pixel level measurement uncertainties without having to store, retrieve and operate on prohibitively large covariance matrices. We describe the POU Framework and SVD compression scheme and its implementation in the Kepler SOC pipeline.

Clarke, Bruce D.↗

Bayesian retrieval of optically relevant properties from hyperspectral water-leaving reflectances

Current methods to retrieve optically relevant properties from ocean color observations do not explicitly make use of prior knowledge about property distributions. Here we implement a simplified Bayesian approach that takes into account prior probability distributions on two sets of five optically relevant parameters, and conduct a retrieval of these parameters using hyperspectral simulated water-leaving reflectances. We focus specifically on the ability of the model to distinguish between two optically similar phytoplankton taxa, diatoms and Noctiluca scintillans. The inversion retrieval gives most-likely concentrations and uncertainty estimates, and we find that the model is able to probabilistically predict the occurrence of Noctiluca scintillans blooms using these metrics. We discuss how this method can be expanded to include a priori covariances between different parameters, and show the effect of varying measurement uncertainty and spectral resolution on Noctiluca scintillans bloom predictions.

Zachary K Erickson↗

Measurement Capabilities of Planar Doppler Velocimetry in Large-Scale Wind Tunnels

Over the past few years, Planar Doppler Velocimetry (PDT) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike some other optical means of measuring flow velocities, PDT is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDT (also called Doppler Global Velocimetry by some authors) have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDT in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDT capabilities for applications in large-scale wind tunnels that are intended primarily for the testing of rotorcraft and subsonic aircraft at speeds typically less than 100 m/s. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region and with a field of view that is sufficient to encompass the entire region of interest. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes, separations, and rotor-tip vortices. To accomplish the objectives of these studies, the PDT measurement process was first modeled and its performance evaluated computationally. The noise sources considered included those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with the coherent illumination of aerosols from pulsed lasers. The signal noise estimates were incorporated into the PDT signal analysis process and combined with computed scattering signals using a Mae scattering theory for a distributed range of aerosol particle sizes. The results are used to define the necessary instrument configuration, to show that the expected signal levels from a practical PDT system are sufficiently large to allow its useful application in large facilities, and to show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing, Experimental studies using several bench-top setups are then described that validate the physics of the PDT model and demonstrate the ability to obtain accurate PDT measurements using procedures that are compatible with large-scale wind tunnel operations. The PDT measurement capabilities found in this study lead to the conclusion that PDT offers significant advantages compared to other means of measuring velocity fields in large-scale wind tunnels, including those operating at low speeds.

McKenzie, Robert L.↗

Off-Body Boundary-Layer Measurement Techniques Development for Supersonic Low-Disturbance Flows

Investigations were performed to develop accurate boundary-layer measurement techniques in a Mach 3.5 laminar boundary layer on a 7 half-angle cone at 0 angle of attack. A discussion of the measurement challenges is presented as well as how each was addressed. A computational study was performed to minimize the probe aerodynamic interference effects resulting in improved pitot and hot-wire probe designs. Probe calibration and positioning processes were also developed with the goal of reducing the measurement uncertainties from 10% levels to less than 5% levels. Efforts were made to define the experimental boundary conditions for the cone flow so comparisons could be made with a set of companion computational simulations. The development status of the mean and dynamic boundary-layer flow measurements for a nominally sharp cone in a low-disturbance supersonic flow is presented.

Owens, Lewis R.↗

Calibration of transonic and supersonic wind tunnels

State-of-the art instrumentation and procedures for calibrating transonic (0.6 less than M less than 1.4) and supersonic (M less than or equal to 3.5) wind tunnels were reviewed and evaluated. Major emphasis was given to transonic tunnels. Continuous, blowdown and intermittent tunnels were considered. The required measurements of pressure, temperature, flow angularity, noise and humidity were discussed, and the effects of measurement uncertainties were summarized. A comprehensive review of instrumentation currently used to calibrate empty tunnel flow conditions was included. The recent results of relevant research are noted and recommendations for achieving improved data accuracy are made where appropriate. It is concluded, for general testing purposes, that satisfactory calibration measurements can be achieved in both transonic and supersonic tunnels. The goal of calibrating transonic tunnels to within 0.001 in centerline Mach number appears to be feasible with existing instrumentation, provided correct calibration procedures are carefully followed. A comparable accuracy can be achieved off-centerline with carefully designed, conventional probes, except near Mach 1. In the range 0.95 less than M less than 1.05, the laser Doppler velocimeter appears to offer the most promise for improved calibration accuracy off-centerline.

Reed, T. D.↗

Science Results From The ARCADE Open-Aperture Cryogenic Balloon Payload

The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the frequency spectrum of the cosmic microwave background and diffuse Galactic foregrounds at centimeter wavelengths. ARCADE greatly reduces measurement uncertainties compared to previous balloon-borne or ground-based instrument using a double-nulled design that features fully cryogenic optics with no windows between the atmosphere and the 2.7 K instrument. A four-hour flight in 2006 achieved sensitivity comparable to the COBE/FIRAS satellite measurement while providing new insights for emission ranging from spinning dust in the interstellar medium to an unexpectedly bright extragalactic radio background. I will discuss scientific results from the ARCADE program and implications of the ARCADE cold optics for millimeter and sub-mm astronomy.

Kogut, Alan J.↗

Violation of Field Line Conservation and Associated Spatial Scales in Particle-In-Cell Simulations and MMS Data

For the first time, space flight technology exists to detect, in situ, violation of magnetic field line conservation. The violation of magnetic line conservation on scales smaller than the system size is a necessary and sufficient condition for finite magnetic field reconnection. We demonstrate that violation of line conservation produces a detectable, structured signature both in particle-in-cell simulations of reconnection and in data from the Magnetospheric Multi-Scale mission. In particle-in-cell simulations of asymmetric reconnection, the quantity-which we call M-that identifies this violation achieves significant values in electron skin depth-scale layers that extend away from the separator, with higher values emerging on the low-density, high-magnetic-field side of the current sheet. At the separator, M owes largely to perpendicular gradients in the parallel electric field, while it attains its highest values away from the separator in dispersed, layered structures associated with gradients in the perpendicular nonideal electric field and electron transport. Sub-ion scale bipolar forms of the quantity also appear further from the separator. In two MMS burst data intervals detecting the electron diffusion region, we find that M exceeds measurement uncertainties both at the separator and near the separatrices. One interval has highly sheared reconnecting fields and the other a stronger guide field. For one event, we determine the location and scale of M and the inner electron diffusion region relative to electron outflows and the magnetic separatrices. The measure can therefore serve as a potent diagnostic for magnetic reconnection in space measurements.

Wendel, Deirdre E.↗

Spatial Statistical Data Fusion (SSDF)

As remote sensing for scientific purposes has transitioned from an experimental technology to an operational one, the selection of instruments has become more coordinated, so that the scientific community can exploit complementary measurements. However, tech nological and scientific heterogeneity across devices means that the statistical characteristics of the data they collect are different. The challenge addressed here is how to combine heterogeneous remote sensing data sets in a way that yields optimal statistical estimates of the underlying geophysical field, and provides rigorous uncertainty measures for those estimates. Different remote sensing data sets may have different spatial resolutions, different measurement error biases and variances, and other disparate characteristics. A state-of-the-art spatial statistical model was used to relate the true, but not directly observed, geophysical field to noisy, spatial aggregates observed by remote sensing instruments. The spatial covariances of the true field and the covariances of the true field with the observations were modeled. The observations are spatial averages of the true field values, over pixels, with different measurement noise superimposed. A kriging framework is used to infer optimal (minimum mean squared error and unbiased) estimates of the true field at point locations from pixel-level, noisy observations. A key feature of the spatial statistical model is the spatial mixed effects model that underlies it. The approach models the spatial covariance function of the underlying field using linear combinations of basis functions of fixed size. Approaches based on kriging require the inversion of very large spatial covariance matrices, and this is usually done by making simplifying assumptions about spatial covariance structure that simply do not hold for geophysical variables. In contrast, this method does not require these assumptions, and is also computationally much faster. This method is fundamentally different than other approaches to data fusion for remote sensing data because it is inferential rather than merely descriptive. All approaches combine data in a way that minimizes some specified loss function. Most of these are more or less ad hoc criteria based on what looks good to the eye, or some criteria that relate only to the data at hand.

Braverman, Amy J.↗

Global CO2 Distributions over Land from the Greenhouse Gases Observing Satellite (GOSAT)

January 2009 saw the successful launch of the first space-based mission specifically designed for measuring greenhouse gases, the Japanese Greenhouse gases Observing SATellite (GOSAT). We present global land maps (Level 3 data) of column-averaged CO2 concentrations (X(sub CO2)) derived using observations from the GOSAT ACOS retrieval algorithm, for July through December 2009. The applied geostatistical mapping approach makes it possible to generate maps at high spatial and temporal resolutions that include uncertainty measures and that are derived directly from the Level 2 observations, without invoking an atmospheric transport model or estimates of CO2 uptake and emissions. As such, they are particularly well suited for comparison studies. Results show that the Level 3 maps for July to December 2009 on a lO x 1.250 grid, at six-day resolution capture much of the synoptic scale and regional variability of X(sub CO2), in addition to its overall seasonality. The uncertainty estimates, which reflect local data coverage, X(sub CO2) variability, and retrieval errors, indicate that the Southern latitudes are relatively well-constrained, while the Sahara Desert and the high Northern latitudes are weakly-constrained. A probabilistic comparison to the PCTM/GEOS-5/CASA-GFED model reveals that the most statistically significant discrepancies occur in South America in July and August, and central Asia in September to December. While still preliminary, these results illustrate the usefulness of a high spatiotemporal resolution, data-driven Level 3 data product for direct interpretation and comparison of satellite observations of highly dynamic parameters such as atmospheric CO2.

Hammerling, Dorit M.↗

Gas temperature and density measurements based on spectrally resolved Rayleigh-Brillouin scattering

The use of molecular Rayleigh scattering for measurements of gas density and temperature is evaluated. The technique used is based on the measurement of the spectrum of the scattered light, where both temperature and density are determined from the spectral shape. Planar imaging of Rayleigh scattering from air using a laser light sheet is evaluated for ambient conditions. The Cramer-Rao lower bounds for the shot-noise limited density and temperature measurement uncertainties are calculated for an ideal optical spectrum analyzer and for a planar mirror Fabry-Perot interferometer used in a static, imaging mode. With this technique, a single image of the Rayleigh scattered light can be analyzed to obtain density (or pressure) and temperature. Experimental results are presented for planar measurements taken in a heated air stream.

Seasholtz, Richard G.↗

Generation of Particles and Seeding

One of the most important elements in laser velocimetry, yet the most neglected, is the small particle embedded in the flow field that scatters the light necessary to make velocity measurements. The characteristics of this small particle are often ignored in the effort to obtain data. This seems strange since it is the primary cause of measurement error. If the particle is too large, it will not follow the flow resulting in an inaccurate representation of the fluid velocity. If the particle is too small, it will not scatter sufficient light to provide the signal-to-noise necessary to minimize measurement uncertainty in the signal processing electronics. This lecture will attempt to remove the confusion in choosing a seeding method by assessing many of the techniques currently used. It will outline their characteristics and typical limitations imposed by various applications. The lecture will then focus on the ramifications of these methods on measurement accuracy.

Meyers, James F.↗

Intensity Biased PSP Measurement

The current pressure sensitive paint (PSP) technique assumes a linear relationship (Stern-Volmer Equation) between intensity ratio (I(sub o)/I) and pressure ratio (P/P(sub o)) over a wide range of pressures (vacuum to ambient or higher). Although this may be valid for some PSPs, in most PSPs the relationship is nonlinear, particularly at low pressures (less than 0.2 psia when the oxygen level is low). This non-linearity can be attributed to variations in the oxygen quenching (de-activation) rates (which otherwise is assumed constant) at these pressures. Other studies suggest that some paints also have non-linear calibrations at high pressures; because of heterogeneous (non-uniform) oxygen diffusion and quenching. Moreover, pressure sensitive paints require correction for the output intensity due to light intensity variation, paint coating variation, model dynamics, wind-off reference pressure variation, and temperature sensitivity. Therefore to minimize the measurement uncertainties due to these causes, an insitu intensity correction method was developed. A non-oxygen quenched paint (which provides a constant intensity at all pressures, called non-pressure sensitive paint, NPSP) was used for the reference intensity (I(sub NPSP) with respect to which all the PSP intensities (I) were measured. The results of this study show that in order to fully reap the benefits of this technique, a totally oxygen impermeable NPSP must be available.

Subramanian, Chelakara S.↗