Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

PMSM Parameter Estimation using a Linear Unknown Input Interval Observer

In this paper, the problem of permanent magnet synchronous motor (PMSM) speed and unknown load torque estimation is addressed. For this purpose, a interval unknown input observer (UIO) for linear time-invariant (LTI) systems is used. First, the PMSM model is linearized in order to make it in a suitable form for the linear interval UIO. Then, the interval UIO is applied to allow the joint estimation of the motor speed and the unknown load torque disturbance. The main advantages of this approach is that it not only allows the joint state and unknown input estimation, but also to take the different uncertainty sources into account. Indeed, taking model and measurement uncertainty into account is crucial. Assuming that the measurement noise and disturbances are bounded, lower and upper bounds are first computed for the unmeasured state (motor speed) and then for the unknown input (load torque). The proposed approach and its limitations are demonstrated with the nonlinear PMSM model derived from its equivalent electrical circuit.

Elinirina I Robinson↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FLEET Velocimetry Measurements on a Transonic Airfoil

Femtosecond laser electronic excitation tagging (FLEET) velocimetry was used to study the flowfield around a symmetric, transonic airfoil in the NASA Langley 0.3-m TCT facility. A nominal Mach number of 0.85 was investigated with a total pressure of 125 kPa and total temperature of 280 K. Two-components of velocity were measured along vertical profiles at different locations above, below, and aft of the airfoil at angles of attack of 0 deg, 3.5 deg, and 7deg. Measurements were assessed for their accuracy, precision, dynamic range, spatial resolution, and overall measurement uncertainty in the context of the applied flowfield. Measurement precisions as low as 1 m/s were observed, while overall uncertainties ranged from 4 to 5 percent. Velocity profiles within the wake showed sufficient accuracy, precision, and sensitivity to resolve both the mean and fluctuating velocities and general flow physics such as shear layer growth. Evidence of flow separation is found at high angles of attack.

Burns, Ross A.↗

Diffuse back-illumination temperature imaging (DBI-TI), a novel soot thermometry technique

To meet stringent emissions regulations on soot emissions, it is critical to further advance the fundamental understanding of in-cylinder soot formation and oxidation processes. Among several optical techniques for soot quantification, diffuse back-illumination extinction imaging (DBI-EI) has recently gained traction mainly due to its ability to compensate for beam steering, which if not addressed, can cause unacceptably high measurement uncertainty. Until now, DBI-EI has only been used to measure the amount of soot along the line of sight, and here, we extend the capabilities of a DBI-EI setup to also measure in-cylinder soot temperature. This proof of concept of diffuse back-illumination temperature imaging (DBI-TI) as a soot thermometry technique is presented by implementing DBI-TI in a single cylinder, heavy-duty, optical diesel engine to provide 2-D line-of-sight integrated soot temperature maps. The potential of DBI-TI to be an accurate thermometry technique for use in optical engines is analyzed. The achievable accuracy is due in part to simultaneous measurement of the soot extinction, which circumvents the uncertainty in dispersion coefficients that depend on the optical properties of soot and the wavelength of light utilized. Analysis shows that DBI-TI provides temperature estimates that are closer to the mass-averaged soot temperature when compared to other thermometry techniques that are more sensitive to soot temperature closer to the detector. Furthermore, uncertainty analysis and Monte Carlo (MC) simulations provide estimates of the temperature measurement errors associated with this technique. The MC simulations reveal that for the light intensities and optical densities encountered in these experiments, the accuracy of the DBI-TI technique is comparable or even better than other established optical thermometry techniques. Thus, DBI-TI promises to be an easily implementable extension to the existing DBI-EI technique, thereby extending its ability to provide comprehensive line-of-sight integrated information on soot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics

Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.

Maisto, Pietro M. F.↗

Self-Calibration and Laser Energy Monitor Validations for a Double-Pulsed 2-Micron CO2 Integrated Path Differential Absorption Lidar Application

Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

Refaat, Tamer F.↗

In situ measurements of the NO2/NO ratio for testing atmospheric photochemical models

Simultaneous in situ measurements of NO2, NO, O3, ClO, pressure and temperature have been made for the first time, presenting a unique opportunity to test our current understanding of the photochemistry of the lower stratospere. Data were collected from several flights of the ER-2 aircraft at mid-latitudes in May 1993 during NASA's Stratospheric Photochemistry, Aerosols and Dynamics Expedition (SPADE). The daytime ratio of NO2/NO remains fairly constant at 19 km with a typical value of 0.68 and standard deviation of +/- 17. The ratio observations are compared with simple steady-state calculations based on laboratory-measured reaction rates and modeled NO2 photolysis rates. At each measurement point the daytime NO2/NO with its measurements uncertainty overlap the results of steady-state caculations and associated uncertainty. Possible sources of error are examined in both model and measurements. It is shown that more accurate laboratory determinations of the NO + 03 reaction rate and of the NO2 cross-sections in the 200-220 K temperature range characteristic of the lower stratosphere would allow for a more robust test of our knowledge of NO(X) phtochemistry by reducing significant sources if uncertainties in the interpretation of statospheric measurements.

Jaegle, L.↗

Observing the earth radiation budget from satellites - Past, present, and a look to the future

Satellite measurements of the radiative exchange between the planet earth and space have been the objective of many experiments since the beginning of the space age in the late 1950's. The on-going mission of the Earth Radiation Budget (ERB) experiments has been and will be to consider flight hardware, data handling and scientific analysis methods in a single design strategy. Research and development on observational data has produced an analysis model of errors associated with ERB measurement systems on polar satellites. Results show that the variability of reflected solar radiation from changing meteorology dominates measurement uncertainties. As an application, model calculations demonstrate that measurement requirements for the verification of climate models may be satisfied with observations from one polar satellite, provided there is information on diurnal variations of the radiation budget from the ERBE mission.

House, F. B.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

The hyperplane of early-type galaxies: using stellar population properties to increase the precision and accuracy of the fundamental plane as a distance indicator

ABSTRACT We use deep spectroscopy from the SAMI (Sydney-AAO Multi-object Integral) Galaxy Survey to explore the precision of the fundamental plane (FP) of early-type galaxies as a distance indicator for future single-fibre spectroscopy surveys. We study the optimal trade-off between sample size and signal-to-noise ratio (SNR), and investigate which additional observables can be used to construct hyperplanes with smaller intrinsic scatter than the FP. We add increasing levels of random noise (parametrized as effective exposure time) to the SAMI spectra to study the effect of increasing measurement uncertainties on the FP- and hyperplane-inferred distances. We find that, using direct-fit methods, the values of the FP and hyperplane best-fitting coefficients depend on the spectral SNR, and reach asymptotic values for a mean $\langle \mathrm{ SNR} \rangle =40\, \mathrm{\mathring{\rm A}}^{-1}$. As additional variables for the FP we consider three stellar-population observables: light-weighted age, stellar mass-to-light ratio, and a novel combination of Lick indices ($I_\mathrm{age}$). For an $\langle \mathrm{ SNR} \rangle =45~\mathrm{\mathring{\rm A}}^{-1}$ (equivalent to 1-h exposure on a 4-m telescope), all three hyperplanes outperform the FP as distance indicators. Being an empirical spectral index, $I_\mathrm{age}$ avoids the model-dependent uncertainties and bias underlying age and mass-to-light ratio measurements, yet yields a 10 per cent reduction of the median distance uncertainty compared to the FP. We also find that, as a by-product, the $I_\mathrm{age}$ hyperplane removes most of the reported environment bias of the FP. After accounting for the different SNR, these conclusions also apply to a 50 times larger sample from SDSS-III (Sloan Digital Sky Survey). However, in this case, only $\mathrm{ age}$ removes the environment bias.

D’Eugenio, Francesco (ORCID:0000000323888172)↗

3D optical diagnostics for explosively driven deformation and fragmentation

High-speed, optical imaging diagnostics are presented for three-dimensional (3D) quantification of explosively driven metal fragmentation. At early times after detonation, Digital Image Correlation (DIC) provides non-contact measures of 3D case velocities, strains, and strain rates, while a proposed stereo imaging configuration quantifies in-flight fragment masses and velocities at later times. Experiments are performed using commercially obtained RP-80 detonators from Teledyne RISI, which are shown to create a reproducible fragment field at the benchtop scale. DIC measurements are compared with 3D simulations, which have been ‘leveled’ to match the spatial resolution of DIC. Overall, results demonstrate improved ability to identify predicted quantities-of-interest that fall outside of measurement uncertainty and shot-to-shot variability. Similarly, video measures of fragment trajectories and masses allow rapid experimental repetition and provide correlated fragment size-velocity measurements. Measured and simulated fragment mass distributions are shown to agree within confidence bounds, while some statistically meaningful differences are observed between the measured and predicted conditionally averaged fragment velocities. Together these techniques demonstrate new opportunities to improve future model validation.

42 ENGINEERING↗

Improved Measurements of Galaxy Star Formation Stochasticity from the Intrinsic Scatter of Burst Indicators

Abstract Measurements of short-timescale star formation variations (i.e., “burstiness” or star formation stochasticity) are integral to our understanding of star formation feedback mechanisms and the assembly of stellar populations in galaxies. We expand upon the work of Broussard et al. by introducing a new analysis of galaxy star formation burstiness that accounts for variations in the Q sg = E B − V stars / E B − V gas distribution, a major confounding factor. We use Balmer decrements from the MOSFIRE Deep Evolution Field (MOSDEF) survey to measure Q sg , which we use to construct mock catalogs from the Santa Cruz Semi-Analytic Models and Mufasa cosmological hydrodynamical simulation based on 3D-HST, Fiber Multi-Object Spectrograph (FMOS)-COSMOS, and MOSDEF galaxies with H α detections. The results of the mock catalogs are compared against observations using the burst indicator η = log 10 ( SFR H α / SFR NUV ) , with the standard deviation of the η distribution indicating burstiness. We find decent agreement between mock and observed η distribution shapes; however, the FMOS-COSMOS and MOSDEF mocks show a systematically low median and scatter in η in comparison to the observations. This work also presents the novel approach of analytically deriving the relationship between the intrinsic scatter in η , scatter added by measurement uncertainties, and observed scatter, resulting in an intrinsic burstiness measurement of 0.06–0.16 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

PLIF Temperature and Velocity Distributions in Laminar Hypersonic Flat-plate Flow

Rotational temperature and velocity distributions have been measured across a hypersonic laminar flat-plate boundary layer, using planar laser-induced fluorescence. The measurements are compared to a finite-volume computation and a first-order boundary layer computation, assuming local similarity. Both computations produced similar temperature distributions and nearly identical velocity distributions. The disagreement between calculations is ascribed to the similarity solution not accounting for leading-edge displacement effects. The velocity measurements agreed to within the measurement uncertainty of 2 % with both calculated distributions. The peak measured temperature was 200 K lower than the computed values. This discrepancy is tentatively ascribed to vibrational relaxation in the boundary layer.

OByrne, S.↗

Review of thermophysical property methods applied to fueled and un-fueled molten salts

Recent investigation into designs of molten salt reactors (MSR) requires accurate data of candidate salts. Review of the literature shows lacking thermophysical (TP) property data for coolants and fuel-bearing salts of Advanced High Temperature Reactors (AHTR). Measurement uncertainties of current data are even more deficient, and this affects ongoing research where MSR modeling and testing are being performed. Melting temperature, viscosity, density, specific heat capacity, and thermal and electrical conductivity measurements are often not arranged together or discussed in great detail, especially for fuel-bearing salts. Raw data from key findings spanning over 70 years for LiF, LiF-BeF 2 , LiF-NaF-KF, KCl-MgCl 2 , KF-ZrF 4 , and NaF-KF-MgF 2 have been organized and presented here. Brief description of methods used to obtain these results, in addition to the TP data of some of these salts as fuel carriers, has also been discussed. Thermal conductivity data are particularly weak due to older, high-error measurement techniques. More recent measurement systems to evaluate salt thermal conductivity show promise for obtaining consistent absolute values. This work concludes that measurement systems such as transient hot-wire method, forced Rayleigh scattering, and laser flash analysis provide the most promise to fill these data gaps and reduce current uncertainty in thermal conductivity measurements of both fueled and un-fueled molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Probabilistic Model-Based Diagnostic Framework for Nuclear Engineering Systems

A fault diagnostic framework was investigated in this study for applications in thermal–hydraulic systems of nuclear power plants. The proposed framework consists of quantitative model-based diagnosis, statistical change detection and probabilistic reasoning. The use of physics-based diagnostic models provides high detection sensitivity and allows noise and measurement uncertainty to be incorporated robustly. Performance-related parametric models for each component are constructed based on first principles. Numerical model residuals are generated using the concept of analytical redundancy. Statistical change detection methods are employed to detect non-zero residuals in the presence of uncertainty. The diagnosis task is performed using Bayesian inference to detect and localize possible faults. Application to a single-phase heat exchanger for demonstration showed that the proposed probabilistic framework can provide improved results in comparison with traditional approaches while remaining less sensitive to false alarms in the presence of measurement and modeling uncertainty.

Bayesian network↗

Optimizing and comparing laser anemometers

Comparisons can be made only if some single valued measure of the quality of each system can be defined. This concept is illustrated here by specifying the quality variable to be the measurement uncertainty in the mean velocity of a turbulent flow in the presence of a large background noise. The Fisher number is used as a figure of merit for some parts of the system. It is noted that in many cases of practical interest, the reciprocal Fisher number gives the actual variance of an estimator. Its principal advantage here is that it can be computed without detailed assumptions about the statistics of the estimated quantities. The concept of a Fisher number is related to the concept of information gain in a measurement. The variance of the measured mean velocity is expressed in terms of the uncertainty for the individual measurements, the measurement rate, and the velocity correlation time. Conditions are given under which the fringe and the two-spot anemometer are optimized.

Edwards, R. V.↗