Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analysis of Irradiance Models for Bifacial PV Modules

We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

14 SOLAR ENERGY↗

Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-349: Dosimetric Comparison of Three Different Simultaneous Integrated Boost Irradiation Techniques for Multiple Brain Metastases: Intensity-Modulatedradiotherapy, Hybrid Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to the whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Numerical Codes for the DESC-LSST Analysis Pipeline: Core Cosmology Library Standard Modules and Beyond wCDM Modules (Final Technical Report)

The overall objective of the project is to investigate and develop specific software modules and analysis components for the software pipeline of LSST Dark Energy Science Collaboration (DESC). Following the key projects of DESC Science Roadmap (SRM), we will write and test computer codes for the Core Cosmology Library (CCL) in order to complete its modules, functionalities, and interface to work with the analysis pipelines from the five science probes of DESC (parts of SRM deliverables CX4.2TJP, CX6.2CS). We will also code modules for CCL to test models beyond w-Cold-Dark-Matter (wCDM) and modification to gravity (MG). Interfaces for MG models will also be developed for the TJPCOSMO software which is the main pipeline of the Theory and Joint Probe (TJP) working group (deliverable TJP2.3). In order to use the full power of LSST data to constrain MG models, we will also work on constraints from nonlinear regime by running and analyzing MG N-Body simulations using a Parameterized-Post-Friedmann framework into the Gadget-2 simulation package (deliverable TJP2.2). Preliminary results for the simulations were obtained in the past. In collaboration with other DESC groups, we plan to make these simulations feedable to cosmic emulators that are practical for likelihood analyzes (deliverable TJP2.2, parts of CX6.2CS). We will also modify and integrate our current codes for consistency tests between data sets and probes into the pipeline (parts of deliverables CX8.2TJP, TJP2.3). We understand that other groups will contribute to some of these objectives but our team will focus and collaborate with others on the particular part of testing MG and models beyond wCDM and refine the DESC pipeline for this purpose. PI has been coordinating his work with the TJP and CS working groups and the DESC management team. PI is a full member of DESC since June 2013. He and his students have been contributing to LSST-DESC activities and work including TJP telecons, collaboration meetings, hack-weeks, and workshops. PI chaired or co-chaired sessions at collaboration meetings and hack-weeks about testing gravity and models beyond wCDM using LSST. He is coordinating the TJP2 projects for testing models beyond wCDM including the writing of DESC-research-note, development of code for pipeline, and N-Body simulations for MG and beyond wCDM models testable with LSST analyses. As stressed in the DESC white paper, SRM, and P5 report, one of the important questions in understanding cosmic acceleration and dark energy is to be able to distinguish whether the acceleration is due to a dark energy component in the universe or a modification to gravity. Answering these questions will have a significant impact on the question of cosmic acceleration and dark energy. The methods that we will use include analytical work, numerical code, and N-Body simulations. A first approach that that we will use consists of using growth rate parameters that enter the perturbed dynamics equations. These parameters take distinctive values for distinct gravity theories and have potential to distinguish between Dark Energy and Modified Gravity. The second method is to look for inconsistencies in Dark Energy parameter spaces using specific combinations of cosmological data sets. Our investigation addresses the Dark Energy problem that is relevant to the mission of the HEP program to understand how our universe works at its most fundamental level. It will allow us to make progress on the HEP mission to explore the nature of Dark Energy and the basic nature of space and time using future surveys such as LSST. The investigation supports the DOE HEP program Cosmic Frontier as it will contribute to the study and understanding of dark energy and fundamental properties of the universe. The investigation contributes directly to LSST-DESC key projects and their deliverables as described in the Science Road-map document to build analysis pipeline and to test dark energy and beyond wCDM models using LSST.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flammability tests for Apollo command module and lunar module mockup

The flammability test program for Apollo command module and lunar module mockups is described. The fire safety design of the modules was verified by performing deliberate ignitions at many locations while the interior atmosphere was controlled to simulate realistic flight conditions. The data obtained for each test and restrictions on various materials are discussed.

Bricker, R. W.↗

Modulation techniques for deep-space pulse-position modulation (PPM) optical communication

The extremely energy-efficient pulse-position modulation (PPM) format is being actively developed as a basis for optical communications with deep-space probes. Attention is presently given to different modulation schemes for the efficient production of laser pulses over a broad range of repetition rates. Both Q-switching and cavity dumping modulation methods are available for the envisioned diode-pumped Nd:YAG laser source. Numerical calculation results are presented for cavity-dumping.

Rayman, Marc D.↗

DC bias modulation characteristics of longitudinal KD*P modulators

A test program designed to study the DC modulation characteristics of longitudinal KD*P modulators and to determine what electrode structure might improve the performance of these devices is presented which was developed in the Marshall Space Flight Center. The physical constraints of these devices and the necessary electrical characteristics that the KD*P modulators must have to be used in the MSFC polarimeter are discussed.

West, ED↗

Modulated Source Interferometry with Combined Amplitude and Frequency Modulation

An improved interferometer is produced by modifying a conventional interferometer to include amplitude and/or frequency modulation of a coherent light source at radio or higher frequencies. The phase of the modulation signal can be detected in an interfering beam from an interferometer and can be used to determine the actual optical phase of the beam. As such, this improvement can be adapted to virtually any two-beam interferometer, including: Michelson, Mach-Zehnder, and Sagnac interferometers. The use of an amplitude modulated coherent tight source results in an interferometer that combines the wide range advantages of coherent interferometry with the precise distance measurement advantages of white light interferometry.

Gutierrez, Roman C.↗

Programmable Thermostat Module Upgrade for the Multi-Purpose Logistics Module

The STS-121/ULF1.1 mission was the maiden flight of the Programmable Thermostat Module (PTM) system used to control the 28 V shell heaters on the Multi-Purpose Logistics Module (MPLM). These PTMs, in conjunction with a Data Recorder Module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This paper will discuss the hardware design, development, test and verification (DDT&V) activities performed at the Marshall Space Flight Center (MSFC) as well as the operational implementation and mission performance.

Clark, Dallas↗

Programmable Thermostat Module Upgrade for the Multipurpose Logistics Module

The STS-121/ULF 1.1 mission was the maiden flight of the programmable thermostat module (PTM) system used to control the 28 V shell heaters on the multi-purpose logistics module (MPLM). These PTMs, in conjunction with a data recorder module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This Technical Memorandum discusses the hardware design, development, test, and verification (DDT&V) activities performed at the Marshall Space Flight Center as well as the operational implementation and mission performance.

Clark, D. W.↗

Gravitational focusing and substructure effects on the rate modulation in direct dark matter searches

We study how gravitational focusing (GF) of dark matter by the Sun affects the annual and biannual modulation of the expected signal in non-directional direct dark matter searches, in the presence of dark matter substructure in the local dark halo. We consider the Sagittarius stream and a possible dark disk, and show that GF suppresses some, but not all, of the distinguishing features that would characterize substructure of the dark halo were GF neglected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗