Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 0.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.↗

Metrology Mount and Optics Mandrels

This document is the Final Report for NASA Grant NAG8-1198 from NASA Marshall Space Flight Center (MSFC) to the Smithsonian Astrophysical Observatory (SAO). The Grant is entitled "Metrology Mount and Optics Materials." This final report is required by the terms of the Grant. The period of performance was from September 15, 1995 through January 14, 1999. Total funding received by SAO from MSFC for this effort was, $254,000. Mr. Lester Cohen carried out most of the work at SAO, but received limited support from other engineers, technicians, and designers. Dr. Harvey Tananbaum, the Principal Investigator for the grant provided overall direction and work- assessment. The Grant has had two funding augmentations to its basic amount and has, over time, emphasized three different research areas - each of which has been an extension of earlier research. The research activity was in 2 areas: (1) Expert opto-structural studies related to separation mechanics and effects of electro formed nickel X-ray mirrors. and (2) Design, fabrication and evaluation of a low force metrology and assembly station for light weight full shell electroformed X-ray mirrors.

Tananbaum, H.↗

MSFC Surface Metrology (Surface Morphology)

NASA's Surface Metrology is presented in viewgraph form. The topics include: 1) Facilities/Major Equipment; 2) Taylor Hobson NanoStep II; 3) Topometrix; and 4) Surface Metrology Applications.

Shapiro, Alan P.↗

Highlights of the ASPE 2004 Winter Topical Meeting on Free-Form Optics: Design, Fabrication, Metrology, Assembly

We present highlights from the American Society for Precision Engineering's 2004 winter topical meeting entitled Free-Form Optics: Design, Fabrication, Metrology, Assembly. We emphasize those papers that are most relevant to astronomical optics. Optical surfaces that transcend the bounds of rotational symmetry have been implemented in novel optical systems with fantastic results since the release of Polaroid's first instant camera. Despite these successes, free-form optics have found only a few niche applications and have yet to enter the mainstream. The purpose of this meeting is to identify the state of the art of free-form optics design, fabrication, metrology and assembly and to identify the technical and logistical challenges that inhibit their widespread use. Issues that will be addressed include: What are free-form optics? How can optical systems be made better with free-form optics? How can designers use free-form optics? How can free-form optics be fabricated? How can they be measured? How are free-form optical systems assembled? Control of multi-axis systems.

Ohl, Raymond G.↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

Performance of the Primary Mirror Center-of-Curvature Optical Metrology System during Cryogenic Testing of the JWST Pathfinder Telescope

The JWST primary mirror consists of 18 1.5 m hexagonal segments, each with 6-DoF and RoC adjustment. The telescope will be tested at its cryogenic operating temperature at Johnson Space Center. The testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The performance of these metrology systems, including hardware, software, procedures, was assessed during two cryogenic tests at JSC, using the JWST Pathfinder telescope. This paper describes the test setup, the testing performed, and the resulting metrology system performance.

JWST↗

Measuring Large Amplitude Surface Figure Error using Coordinate Metrology

Advances in optical testing are as important as advances in optical fabrication, because one can make only what one can measure, particularly for unconventional prescriptions, like aspheric and freeform optics. A new, high-precision metrology capability is utilized to close the gap between interferometric testing and lower precision, contact-probe-based coordinate measuring machines or laser tracker/radar metrology to accurately measure surfaces with large figure error. This nearly universal optical testing method employs an ultra-precision coordinate measuring machine equipped with a non-contact probe. It was developed to characterize a broad spectrum of optical surfaces including ones with high slopes, impossible to measure using traditional interferometric testing. Optical components, covering a wide range of prescriptions, such as large convex conics, high-sloped aspherics, grazing-incidence x-ray optics, and highly deformed flats, were successfully measured. The resulting data were reduced using custom-developed routines to determine the optic’s alignment, surface departure from design, and the as-built optical prescription. This information guided the fabrication and modeling of these optical components

Manal Khreishi↗

Model validation of SIM external metrology at the sub-nanometer level

In order to achieve micro-arcsecond astrometry, SIM must make measurements of various optical path lengths at the picometer level. In this regime of precision, nearly every simplifying assumption in optics must be reexamined as a potential source of systematic error. SIM makes extensive use of physics-based models to predict the form and level of systematic errors affecting instrument performance. Since many of the modeling areas represent new frontiers in optical modeling, the validation of these physical models is a significant challenge that SIM must meet. In the case of the external metrology truss, the model must account for the imperfections in the corner cubes as well as the distance measuring interferometers ("beam launchers"). This model is being validated using the Kite testbed, a 2-D metrology truss with picometer-level accuracy in displacement measurements. We present the model and the results of the model validation tests on the Kite testbed.

Kuan, Gary M.↗

Earth Energy Balance Assessment at the 2022 BIPM-WMO Metrology for Climate Action Workshop

The BIPM and WMO hosted a five-day workshop in Sept. 2022 to assess the state of current metrology and identify future meteorological needs regarding climate change for the upcoming decade. A resulting broad policy-oriented workshop summary report, written by the workshop’s ~70 international organizers and reviewed by meeting attendees, identifies the current issues in each of nine high-level topic areas and provides recommendations to address them, listing specific needs, pathways, timelines, and responsible agencies or organizations for each. One prominent Topic within the workshop, “Earth Energy Balance,” was organized by the authors of this presentation and resulted in a section of the workshop summary report using the contributions from the topic’s several pre-recorded oral and poster presentations and the outcomes of two interactive real-time community-wide discussion sessions. The Earth-energy-balance topic issues centered on three areas: Radiometric energy measurements, including needed accuracies and stabilities and the use of SI-Traceable Satellites (SITSats), such as CLARREO and TRUTHS, to achieve them; improved on-orbit calibration sources, including the Sun and the Moon, thermal-infrared and UV sources, and space-flight blackbodies; and the four primary Earth-heat storage reservoirs of the oceans, land, permafrost, and cryosphere, giving an inventory of where and how much of the Earth’s energy is stored and how much uptake there is of the incoming energy. This presentation will summarize the results of the Earth Energy Balance topic from the 2022 BIPM-WMO Metrology for Climate Action Workshop.

earth↗

Albuquerque Regional Training: The Third Seminar on Surface Metrology for the Americas May 12-13 2014

The Third Seminar on Surface Metrology for the Americas (SSMA) took place in Albuquerque, New Mexico May 12-13, 2014. The conference was at the Marriott Hotel, in the heart of Albuquerque Uptown, within walking distance of many fantastic restaurants. Why surface metrology? Ask Professor Chris Brown of Worcester Polytechnic Institute (WPI), the chair of the first two SSMAs in 2011 and 2012 and the chair of the ASME B46 committee on classification and designation of surface qualities, and Professor Brown responds: “Because surfaces cover everything.”

42 ENGINEERING↗

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a highly curved super-quality substrate with less than 0.3 microradian (rms)slope variation.

47 OTHER INSTRUMENTATION↗

INVESTIGATING SCALING LIMITS OF A FIBER BASED RESONANT PROBE FOR METROLOGY APPLICATIONS

Currently, Inertial Confinement Fusion (ICF) and High Energy Density Science (HEDS) targets comprise components with dimensions in the millimeter range, while having micrometerscale, high aspect ratio functional features, including fill-tube holes and counterbores, slotted patterns, and step-joint geometry on hemispherical targets. Representative geometry is shown in Figure 1. Future target designs will likely have additional challenging features. The dimensional metrology of these features is important for a number of reasons, including quantifying geometrical tolerances of as-built components prior to delivery, qualification of sub-components prior to assembly, and as a feedback mechanism for fabrication process development. Variations in geometry from part to part can lead to functional limitations, such as limited flow rates during target filling, unpredictable instabilities during an experiment, and the inability to assemble a target from poorly matched sub-components. Adding to the complexity are the large number and variety of materials, components, and shapes that render any single metrology technique difficult to use with low uncertainty. Adapting standing wave probe technology [i] for micrometer sized features requires the understanding of the physical interaction between the oscillating, slender rod (probe) and the sample as a means of transferring information about the surface, such as topography and material properties, analogous to tapping mode atomic force microscopy (AFM) and/or instrumented indentation machines. By utilizing the variation in dynamic response of the probe as the tip interacts with a surface, information about the sample may be obtained and used for mapping surface topography, and potentially characterizing material properties. The novel long aspect ratio geometry of the probe enables the characterization of features such as small holes, slots, and corners, which typically cannot be accessed using AFM and instrumented indentation technology. Uncertainty of the surface location is a combination of near surface effects such as van der Waals and electrostatic forces combined with contact force such adhesion and meniscus contributions. In addition, environmental effects, such as thermal gradients and air turbulence, will influence probe performance and repeatability. A combination of complex nonlinear models of the tuning fork driver/sensor mechanics, fiber dynamics, circuit response and contact interactions have been developed for the current scale system in an effort to predict scaling limitations of this technology for characterizing micrometer sized features with nanometer sensitivity.

42 ENGINEERING↗

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situvisible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situ visible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

47 OTHER INSTRUMENTATION↗

Multi-pitch nano-accuracy surface profiler for strongly curved X-ray mirror metrology

We present our recent research and development effort on the Multi-Pitch Nano-accuracy Surface Profiler (MPNSP). This metrology instrument is developed to characterize strongly curved X-ray mirrors proposed to achieve diffraction-limited soft X-ray focusing for scientific applications at the synchrotron beamlines. The measurement process consists of forward-and-backward scans on the test mirror surface along its tangential direction at multiple pitch angles. Our research and development in this work aim to take the challenge of measuring strongly curved X-ray mirrors with a typical total slope range ≳10 mrad, while maintaining the Root Mean Square (RMS) value of measurement repeatability and self-consistency at 50 nrad RMS level. We first introduce the mechanical design, followed by a brief review of the mathematical model and the optimization algorithm for the MPNSP technique. By detecting the rotation axis of the mirror pitch with a machine vision approach, we can determine and then reduce the vertical distance between the pitch rotation axis and the test mirror surface to a sub-mm level. In addition, we describe a practical data acquisition procedure for strongly curved X-ray mirrors with a total slope range larger than the slope measuring range of the autocollimator used in the instrument. As a result, the proposed MPNSP measurements with different mirror orientations achieve remarkable self-consistency and reproducibility of < 50 nrad RMS in slope and < 0.5 nm RMS in height.

42 ENGINEERING↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗