Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNPX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Measurement of Thick Target Neutron Yields at 0-Degree Bombarded With 140-MeV, 250-MeV And 350-MeV Protons

Neutron energy spectra at 0{sup o} produced from stopping-length graphite, aluminum, iron and lead targets bombarded with 140, 250 and 350 MeV protons were measured at the neutron TOF course in RCNP of Osaka University. The neutron energy spectra were obtained by using the time-of-flight technique in the energy range from 10 MeV to incident proton energy. To compare the experimental results, Monte Carlo calculations with the PHITS and MCNPX codes were performed using the JENDL-HE and the LA150 evaluated nuclear data files, the ISOBAR model implemented in PHITS, and the LAHET code in MCNPX. It was found that these calculated results at 0{sup o} generally agreed with the experimental results in the energy range above 20 MeV except for graphite at 250 and 350 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulated Performance of the Integrated PNAR and SINRD Detector Designed for Spent Fuel Measurements at the Fugen Reactor in Japan

Objective is to investigate the use of Passive Neutron Albedo Reactivity (PNAR) and Self-Interrogation Neutron Resonance Densitometry (SINRD) to quantify fissile content in FUGEN spent fuel assemblies (FAs). Methodology used is: (1) Detector was designed using fission chambers (FCs); (2) Optimized design via MCNPX simulations; and (3) Plan to build and field test instrument in FY13. Significance was to improve safeguards verification of spent fuel assemblies in water and increase sensitivity to partial defects. MCNPX simulations were performed to optimize the design of the SINRD+PNAR detector. PNAR ratio was less sensitive to FA positioning than SINRD and SINRD ratio was more sensitive to Pu fissile mass than PNAR. Significance was that the integration of these techniques can be used to improve verification of spent fuel assemblies in water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new NCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing Monte Carlo N-Particle (MCNPX) particle tracking (PTRAC) coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the nuclides that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and nuclide that underwent induced fission). Here, the power of this tool is demonstrated using a detector design developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile nuclides of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Long Range Active Detection of HEU Based on Thermal Neutron Multiplication

We report on the results of measurements of proton irradiation on a series of targets at Brookhaven National Laboratory’s (BNL) Alternate Gradient Synchrotron Facility (AGS), in collaboration with LANL and SNL. We examined the prompt radiation environment in the tunnel for the DTRA-sponsored series (E 972), which investigated the penetration of air and subsequent target interaction of 4 GeV proton pulses. Measurements were made by means of an organic scintillator with a 500 MHz bandwidth system. We found that irradiation of a depleted uranium (DU) target resulted in a large gamma-ray signal in the 100-500 µsec time region after the proton flash when the DU was surrounded by polyethylene, but little signal was generated if it was surrounded by boron-loaded polyethylene. Subsequent Monte Carlo (MCNPX) calculations indicated that the source of the signal was consistent with thermal neutron capture in DU. The MCNPX calculations also indicated that if one were to perform the same experiment with a highly enriched uranium (HEU) target there would be a distinctive fast neutron yield in this 100-500 µsec time region from thermal neutron-induced fission. The fast neutrons can be recorded by the same direct current system and differentiated from gamma ray pulses in organic scintillator by pulse shape discrimination.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analyses to support waste disposition of SNS Inner Reflector Plug

The Spallation Neutron Source Inner Reflector Plug (IRP) is scheduled for replacement. It reached end of life-time because of moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. In order to support the disposal of spent IRP, waste characterization analyses are performed. These analyses include an accurate estimate of the radionuclide inventory and the residual dose rate. Using this data, the package class is determined for the and appropriate containers for temporary storage and subsequent transport are assigned. Analyses are performed in four steps: a radiation transport analysis of the radiation environment for producing the flux and isotope production information using MCNPX, a multi-cell transmutation analysis based n CINDER90, the generation of decay gamma source terms, and the gamma transport analyses of the decay gammas arriving at residual dose rates again using MCNPX. . Due to the complexity of the geometry of the lower segment, transport analyses for the residual dose rate require elaborate work for the source terms definition.

Popova, Irina I.↗

3D neutronic/thermal-hydraulic coupled analysis of MYRRHA

The current tendency in multiphysics calculations applied to reactor physics is the use of already validated computer codes, coupled by means of an iterative approach. In this paper such an approach is explained concerning neutronics and thermal-hydraulics coupled analysis with MCNPX and COBRA-IV codes using a driver program and file exchange between codes. MCNPX provides the neutronic analysis of heterogeneous nuclear systems, both in critical and subcritical states, while COBRA-IV is a subchannel code that can be used for rod bundles or core thermal-hydraulics analysis. In our model, the MCNP temperature dependence of nuclear data is handled via pseudo-material approach, mixing pre-generated cross section data set to obtain the material with the desired cross section temperature. On the other hand, COBRA-IV has been updated to allow for the simulation of liquid metal cooled reactors. The coupled computational tool can be applied to any geometry and coolant, as it is the case of single fuel assembly, at pin-by-pin level, or full core simulation with the average pin of each fuel-assembly. The coupling tool has been applied to the critical core layout of the SCK-CEN MYRRHA concept, an experimental LBE cooled fast reactor presently in engineering design stage. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of pin removal experiments conducted in an SCWR-like test lattice

A comprehensive program of integral experiments, largely based on the measurement of reaction rate distributions, was carried out recently on an SCWR-like fuel lattice in the central test zone of the PROTEUS zero-power research reactor at the Paul Scherrer Inst. in Switzerland. The present paper reports on the analysis of a complementary set of measurements, in which the reactivity effects of removing individual pins from the unperturbed, heterogeneously moderated reference lattice were investigated. It has been found that the detailed Monte Carlo modeling of the whole reactor using MCNPX is able - as in the case of the reaction rate distributions - to reproduce the experimental results for the pin removal worths within the achievable statistical accuracy. A comparison of reduced-geometry calculations between MCNPX and the deterministic LWR assembly code CASMO-4E has revealed certain discrepancies. On the basis of a reactivity decomposition analysis of the differences between the codes, it has been suggested that these could be due to CASMO-4E deficiencies in calculating the effect, upon pin removal, of the extra moderation in the neighboring fuel pins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

GUINEVERE experiment: Kinetic analysis of some reactivity measurement methods by deterministic and Monte Carlo codes

The GUINEVERE experiment (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) is an experimental program in support of the ADS technology presently carried out at SCK-CEN in Mol (Belgium). In the experiment a modified lay-out of the original thermal VENUS critical facility is coupled to an accelerator, built by the French body CNRS in Grenoble, working in both continuous and pulsed mode and delivering 14 MeV neutrons by bombardment of deuterons on a tritium-target. The modified lay-out of the facility consists of a fast subcritical core made of 30% U-235 enriched metallic Uranium in a lead matrix. Several off-line and on-line reactivity measurement techniques will be investigated during the experimental campaign. This report is focused on the simulation by deterministic (ERANOS French code) and Monte Carlo (MCNPX US code) calculations of three reactivity measurement techniques, Slope ({alpha}-fitting), Area-ratio and Source-jerk, applied to a GUINEVERE subcritical configuration (namely SC1). The inferred reactivity, in dollar units, by the Area-ratio method shows an overall agreement between the two deterministic and Monte Carlo computational approaches, whereas the MCNPX Source-jerk results are affected by large uncertainties and allow only partial conclusions about the comparison. Finally, no particular spatial dependence of the results is observed in the case of the GUINEVERE SC1 subcritical configuration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of GPU-based Monte Carlo code for fast CT imaging dose calculation on CUDA Fermi architecture

This paper describes the development of a Graphics Processing Unit (GPU) accelerated Monte Carlo photon transport code, ARCHER{sub GPU}, to perform CT imaging dose calculations with good accuracy and performance. The code simulates interactions of photons with heterogeneous materials. It contains a detailed CT scanner model and a family of patient phantoms. Several techniques are used to optimize the code for the GPU architecture. In the accuracy and performance test, a 142 kg adult male phantom was selected, and the CT scan protocol involved a whole-body axial scan, 20-mm x-ray beam collimation, 120 kVp and a pitch of 1. A total of 9 x 108 photons were simulated and the absorbed doses to 28 radiosensitive organs/tissues were calculated. The average percentage difference of the results obtained by the general-purpose production code MCNPX and ARCHER{sub GPU} was found to be less than 0.38%, indicating an excellent agreement. The total computation time was found to be 8,689, 139 and 56 minutes for MCNPX, ARCHER{sub CPU} (6-core) and ARCHER{sub GPU}, respectively, indicating a decent speedup. Under a recent grant funding from the NIH, the project aims at developing a Monte Carlo code with the capability of sub-minute CT organ dose calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

In-Situ Assays Using a New Advanced Mathematical Algorithm - 12400

Current mathematical efficiency modeling software for in-situ counting, such as the commercially available In-Situ Object Calibration Software (ISOCS), typically allows the description of measurement geometries via a list of well-defined templates which describe regular objects, such as boxes, cylinder, or spheres. While for many situations, these regular objects are sufficient to describe the measurement conditions, there are occasions in which a more detailed model is desired. We have developed a new all-purpose geometry template that can extend the flexibility of current ISOCS templates. This new template still utilizes the same advanced mathematical algorithms as current templates, but allows the extension to a multitude of shapes and objects that can be placed at any location and even combined. In addition, detectors can be placed anywhere and aimed at any location within the measurement scene. Several applications of this algorithm to in-situ waste assay measurements, as well as, validations of this template using Monte Carlo calculations and experimental measurements are studied. Presented in this paper is a new template of the mathematical algorithms for evaluating efficiencies. This new template combines all the advantages of the ISOCS and it allows the use of very complex geometries, it also allows stacking of geometries on one another in the same measurement scene and it allows the detector to be placed anywhere in the measurement scene and pointing in any direction. We have shown that the template compares well with the previous ISOCS software within the limit of convergence of the code, and also compare well with the MCNPX and measured data within the joint uncertainties for the code and the data. The new template agrees with ISOCS to within 1.5% at all energies. It agrees with the MCNPX to within 10% at all energies and it agrees with most geometries within 5%. It finally agrees with measured data to within 10%. This mathematical algorithm can now be used for quickly and accurately evaluating efficiencies for wider range of gamma-ray spectroscopy applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new cubic phantom for PET/CT dosimetry: Experimental and Monte Carlo characterization

In recent years, positron emission tomography (PET) associated with multidetector computed tomography (MDCT) has become a diagnostic technique widely disseminated to evaluate various malignant tumors and other diseases. However, during PET/CT examinations, the doses of ionizing radiation experienced by the internal organs of patients may be substantial. To study the doses involved in PET/CT procedures, a new cubic phantom of overlapping acrylic plates was developed and characterized. This phantom has a deposit for the placement of the fluorine-18 fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) solution. There are also small holes near the faces for the insertion of optically stimulated luminescence dosimeters (OSLD). The holes for OSLD are positioned at different distances from the {sup 18}F-FDG deposit. The experimental results were obtained in two PET/CT devices operating with different parameters. Differences in the absorbed doses were observed in OSLD measurements due to the non-orthogonal positioning of the detectors inside the phantom. This phantom was also evaluated using Monte Carlo simulations, with the MCNPX code. The phantom and the geometrical characteristics of the equipment were carefully modeled in the MCNPX code, in order to develop a new methodology form comparison of experimental and simulated results, as well as to allow the characterization of PET/CT equipments in Monte Carlo simulations. All results showed good agreement, proving that this new phantom may be applied for these experiments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

MCNP 6.2.0 Delayed-Particle Production Improvements

Development began on a delayed-particle physics package for the Monte Carlo Radiation transport code MCNPX in 2004 incorporating the CINDER90 depletion code and delayed particle libraries. When MCNP5 was merged with MCNPX to form MCNP6 in 2010, this delayed-particle capability was passed on and has been continuously improved in subsequent versions of MCNP6. Today, the delayed-particle feature in MCNP6 allows for the production of delayed neutrons, gammas, betas, and alpha particles. Future development includes the addition of delayed-positron production in the next release of MCNP6. Delayed particles can be sampled with MCNP using the ACT card in conjunction with the FISSION and NONFISS keywords. The user can specify one or more of the four available delayed-particle types mentioned above on one or both of the FISSION and NONFISS keywords. If a delayed-particle type is selected on the FISSION keyword, then delayed production of that particle from fission products and their progeny will be produced. Likewise, if a delayed-particle type is selected on the NONFISS keyword then delayed production of that particle from non-fission interactions and spontaneous decay will be produced. In some cases, the sheer number of delayed particles that can be produced from nuclear reactions and spontaneous decay (i.e. hundreds of delayed gamma lines when spontaneous fission is possible) can make it difficult to achieve converged solutions in an efficient and timely manner. Truncation methods are the simplest form of variance reduction and can be used to decrease convergence times by limiting calculations to the phase space of interest. This paper introduces several such truncation methods that allow the user to restrict the number of possible delayed particles available for sampling to only those of interest in the problem. It is important to stress that the use of any truncation method should be verified by first assessing the impact of the truncated particles (i.e. by disabling the truncation) for one or more baseline cases. In addition to these new methods, a new delayed-gamma sampling algorithm implemented in MCNP 6.2.0 is introduced. Comparisons to ENDF data and analytical benchmarking with the new algorithm show a substantial improvement in accuracy over previous versions. New improvements to the delayed-particle capability have been added to MCNP 6.2.0. These improvements include an updated treatment of the THRESH keyword which omits delayed-particle lines below a set amplitude, and addition of the PECUT and HLCUT keywords which allow the user to truncate delayed-particles lines based on energy and half-life, respectively. The delayed-gamma sampling algorithm has also been improved to allow exact energy sampling. Comparisons of MCNP calculations directly to ENDF data and analytical benchmarks have verified the significant improvement in the new delayed gamma sampling algorithm. (authors)

97 MATHEMATICS AND COMPUTING↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Acceleration Techniques using ADVANTG for the MDF Design and Optimization

The Spallation Neutron Source (SNS) facility at Oak Ridge National Laboratory (ORNL) is implementing a Moderator Demonstration Facility (MDF) to demonstrate the performance characteristics of advanced moderators central to the Second Target Station (STS) for SNS. The MDF will provide a small, short-pulsed neutron source for slow neutron production in which we intend to easily and quickly change from one moderator concept to another, characterizing the performance of each moderator in a reproducible and consistent fashion. The MDF will be unique and innovative amongst the world's moderator test facilities in that it will be intended to be very prototypic in terms of 'moderator illumination' - the spatial variation of the neutron flux entering the moderator itself - as well as capable of testing so-called high-brightness moderators in a wing configuration. During the design phase of the MDF, the Monte Carlo N-Particle transport code MCNPX v.2.7.0 is being used as the primary tool for the neutronic analysis of the facility and characterization of the moderator performance. The Automated Variance Reduction Generator (ADVANTG) code is being utilized to accelerate the MCNPX calculations. The ADVANTG code generates space- and energy-dependent weight window parameters for a successive MCNP run by calculating the adjoint flux with the Denovo discrete ordinates code based on the user defined MCNP tally. We have tested various strategies using ADVANTG to generate weight window parameters to efficiently calculate detailed moderator performance. Using point detector response functions for weight window parameter optimization with ADVANTG did not work well for improving the efficiency of Monte Carlo calculations of neutron emission into beam lines. However, using cell fluxes of the area of highest contributions to the point detector for the variance reduction parameter analysis worked very well and improved the FOM of the calculation of neutron emission into a beamline by a factor of 50 over the unbiased case. (authors)

42 ENGINEERING↗

Speed and Memory Improvements to MCNP6 Delayed-Gamma Line Treatment

The delayed-gamma (DG) line-emission (line) sampling was first introduced into MCNPX in 2005. At the time, storage demands for problems with large numbers of DG lines was a major concern. In order to accommodate large amounts of line data while keeping the memory footprint of such a problem from exceeding memory limits, complicated logic was included to sift through various storage options. In mid-2015 concerns arose over the adequacy of the MCNP6 DG source option (inherited from MCNPX) with line sampling for modeling high-fidelity problems. One indication that there was a problem came when studying the MCNP6 produced DG spectra of U-238 and its progeny using high-fidelity spectroscopic tallies when compared to DG line amplitudes directly from ENDF/B-VII.1 emission data. Despite producing a correct integral number of gammas, the comparison to ENDF data showed a broadening in the energy lines and a reduction in the amplitude of more prominent lines. It was later found that the cause of this broadening was one of the memory-saving techniques used to store DG line data when problems required many DG lines. Specifically, the DG lines were integrated into fine energy bins for sampling. When a DG line was to be sampled, a random number would be used to choose which energy bin to sample based on emission probability. Once chosen, a second random number was used to perform nearest-line sampling in that bin. The integration of lines led to an oversampling of low-probability lines, especially when in close proximity to high-probability lines. This treatment also caused a similar issue with the time-dependent behavior of DG line emission which occurred when low-probability lines were sampled near high probability lines with the former decay constant being used. The effect on time-dependent gamma production was demonstrated in analytic benchmarks performed by Weldon et al.. To address these issues a new gamma line storage and sampling treatment was introduced in 2015. This new treatment, stores gamma emission data in a line-by-line CDF which is sampled directly, thereby resolving both the line-broadening issue, and the time-dependence issue as was demonstrated by Tutt el al.. In addition, the new DG sampling treatment was written to use dynamically dimensioned storage arrays as opposed to large fixed-dimensioned arrays, as in the former treatment, and also makes more efficient use of line data that is stored by reducing or eliminating repeated data. As a result, storage arrays are generated only for DG data relevant to the problem being executed. The result should be a reduction in both memory requirements and runtime. However, these reductions could not be realized until the logic for the old treatment could be removed. This paper provides an update on recent work which has focused on the removal of the old DG sampling logic and attempts to quantify the memory reduction and speed up of selected problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP6 Gets Correlated with CGM 3.4 - Paper 41

Version 3.4 of the Cascading Gamma-ray Multiplicity (CGM) code has been integrated into version 6 of the Monte Carlo radiation transport code MCNP. The current release is MCNP6 which is the merger of MCNPX 2.7.0 and MCNP5. MCNP6 is a general purpose Monte Carlo radiation transport code that can transport 34 different particles and heavy ions. CGM was originally integrated into MCNPX 2.7.0 as an undocumented feature, but was never released to the public. With the integration of CGM into MCNP6 the code now has the capability of producing correlated secondary particle/gamma emissions and should be available in future release of MCNP. Before the integration of CGM, MCNP only used libraries that contain the total multiplicity but not the multiplicity distribution or the correlations. Lacking this information requires the code to use integer sampling to determine the multiplicity. In the example of thermal neutron capture on Cl-35, presented in the results section, MCNP does integer sampling. This means MCNP would produce one gamma 17% of the time and two gammas 82% giving a mean multiplicity of 1.83. Using CGM, MCNP can now produce a spectrum of multiplicities. The use of CGM has several advantages over the use of ACE data libraries in MCNP6: 1) it has correlated gamma production, 2) it produces a distribution of gamma multiplicities per interaction, whereas ACE produces an average between two integer multiplicities, 3) it is a theoretical model that may predict experimentally unmeasured physical quantities that may not be in experimental based data libraries. CGM conserves energy and angular momentum internally to CGM; however, angular emission information is not currently sent back to MCNP6. Future work will include the integration of correlated neutrons from CGM. Also, the reaction type will be passed to CGM to set the spin and parity for a particular reaction when possible. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

CINDER08 and Scripting Environment for Accelerator Activation Problems - Paper 101

CINDER is a transmutation code, developed originally at the Bettis Atomic Power Laboratory, which predicts induced radioactivity due to either reactor or accelerator-driven radiation sources. The code and associated data libraries have been expanded and improved over the years at Los Alamos National Laboratory. CINDER08 is the latest update in the series and represents a complete rewrite of CINDER, improving it in many areas. Beginning with CINDER90, several Perl scripts were developed to treat multi-cell problems in combination with the radiation transport code MCNPX. These scripts simplified the preparation of CINDER input and made the code much more user-friendly. In concert with the development of CINDER08, these scripting tools have also been updated. The script developers are intensive users of CINDER and had significant input into the development of CINDER08. CINDER08, through use of these scripts, also works with output from MCNP5, which is useful for problems that do not require the extended particle capabilities of MCNPX and do not require particle energies outside of the tabular physics regime, and with MCNP6. A new version of CINDER, CINDER08, incorporates many improvements to the coding and the data libraries. Updated versions of scripting tools improve the code's usability and simplify the use of CINDER output as the basis of gamma source terms for subsequent calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Air Activation Calculations for Electron Linear Accelerators - Paper 114

Electron linear accelerators produce x-ray photons when the beam interacts with material such as beam stops or beamline components. These photons subsequently cause radioactivation in air, primarily through ({gamma},n) reactions. While most of these nuclides have short half-lives, they can lead to doses to personnel entering the accelerator or experimental areas and can be released to the environment. Accurate calculations are needed for the production, decay, and clearance of these nuclides. This paper discusses two treatments of air activation. An approximate treatment makes use of the fact that the Bremsstrahlung photon fluence is proportional to beam power and the path length in air, but does not account for heavily shielded loss points or how far the beam energy is above each reaction threshold. Using detailed radiation transport codes like MCNPX avoids these problems. Examples are provided for two electron linear accelerators at Argonne National Laboratory: the Low-Energy Accelerator Facility (LEAF) and the Argonne Wakefield Accelerator (AWA). MCNPX was used to calculate photonuclear reaction rates in the air at two electron accelerators at Argonne. Combined with realistic models for air exhaust, these results were used to calculate effects to facility staff, other personnel, and the environment. (authors)

43 PARTICLE ACCELERATORS↗