At least 181 records · Page 10

Lithium Batteries and Supercapacitors Capable of Operating at Low Temperatures for Planetary Exploration

Demonstrated improved performance with wide operating temperature electrolytes containing ester co - solvents (i.e., methyl propionate and ethyl butyrate) in a number of prototype cells: center dot Successfully scaled up low temperature technology to 12 Ah size prismatic Li - ion cells (Quallion, LCC), and demonstrated good performance down to - 60 o C. center dot Demonstrated wide operating temperature range performance ( - 60 o to +60 o C) in A123 Systems LiFePO 4 - based lithium - ion cells containing methyl butyrate - based low temperature electrolytes. These systems were also demonstrated to have excellent cycle life performance at ambient temperatures, as well as the ability to be cycled up to high temperatures.

Li-ion Batteries↗

The Role of Electrolyte Upon the SEI Formation Characteristics and Low Temperature Performance of Lithium-Ion Cells With Graphite Anodes

Quarternary lithium-ion battery electrolyte solutions containing ester co-solvents in mixtures of carbonates have been demonstrated to have high conductivity at low temperatures (< -20C). However, in some cases the presence of such co-solvents does not directly translate into improved low temperature cell performance, presumably due to the formation of ionically resistive surface films on carbonaceous anodes. In order to understand this behavior, a number of lithium-graphite cells have been studied containing electrolytes with various ester co-solvents, including methyl acetate (MA), ethyl acetate (EA), ethyl propionate (EP), and ethyl butyrate (EB). The charge/discharge characterization of these cells indicates that the higher molecular weight esters result in electrolytes which possess superior low temperature performance in contrast to the lower molecular weight ester-containing solutions, even though these solutions display lower conductivity values.

Smart, M. C.↗

Ion Storage Ring Measurements of Low Temperature Dielectronic Recombination Rate Coefficients for Modeling X-Ray Photoionized Cosmic Plasmas

Low temperature dielectronic recombination (DR) is the dominant recombination mechanism for most ions in X-ray photoionized cosmic plasmas. Reliably modeling and interpreting spectra from these plasmas requires accurate low temperature DR rate Coefficients. Of particular importance are the DR rate coefficients for the iron L-shell ions (Fe XVII-Fe XXIV). These ions are predicted to play an important role in determining the thermal structure and line emission of X-ray photoionized plasmas, which form in the media surrounding accretion powered sources such as X-ray binaries (XRBs), active galactic nuclei (AGN), and cataclysmic variables (Savin et al., 2000). The need for reliable DR data of iron L-shell ions has become particularly urgent after the launches of Chandra and XMM-Newton. These satellites are now providing high-resolution X-ray spectra from a wide range of X-ray photoionized sources. Interpreting the spectra from these sources requires reliable DR rate coefficients. However, at the temperatures relevant, for X-ray photoionized plasmas, existing theoretical DR rate coefficients can differ from one another by factors of two to orders of magnitudes.

Savin, D. W.↗

Effect of low temperature on metabolism of rat liver slices and epididymal fat pads.

Study of low temperature effects on the metabolism of radioisotope-tagged glucose and palmitate in rat liver slices and epididymal fat pads. The obtained data suggest that the oxidative capacity of rat liver and adipose tissue is maintained at low temperatures to a greater degree than the synthetic capacity. It was concluded that sufficient energy can be produced at 17 C for maintenance of essential tissue functions by these two tissues but that the energy requirements may not be met at 7 C.

Hillyard, L. A.↗

Apparatus for high-pressure and low-temperature experiments

A new type of apparatus for high-pressure experiments at low temperature (1.5 K) is presented. It uses a flat diamond anvil with a spherical indentor. It utilizes a load ring placed under the sample, so that the load (and hence pressure) can be measured in situ at low temperature. The apparatus was successfully used to investigate the high-conductivity state of sulphur. It can be used to investigate other thin film samples.

Golopentia, D. A.↗

Investigation of heat transfer in zirconium potassium perchlorate at low temperature: A study of the failure mechanism of the NASA standard initiator

The objective of this work was to study the reasons for the failure of pyrotechnic initiators at very low temperatures (10 to 100 K). A two-dimensional model of the NASA standard initiator was constructed to model heat transfer from the electrically heated stainless steel bridgewire to the zirconium potassium perchlorate explosive charge and the alumina charge cup. Temperature dependent properties were used in the model to simulate initiator performance over a wide range of initial temperatures (10 to 500 K). A search of the thermophysical property data base showed that pure alumina has a very high thermal conductivity at low temperatures. It had been assumed to act as a thermal insulator in all previous analyses. Rapid heat transfer from the bridgewire to the alumina at low initial temperatures was shown to cause failure of the initiators if the wire did not also make good contact with the zirconium potassium perchlorate charge. The mode is able to reproduce the results of the tests that had been conducted to investigate the cause for failure. It also provides an explanation for previously puzzling results and suggests simple design changes that will increase reliability at very low initial temperatures.

Varghese, Philip L.↗

Low temperature multi-alkali photocathode processing technique for sealed intensified CCD tubes

A low temperature photocathode process has been used to fabricate an intensified CCD visual photocathode image tube, by incorporating a thinned, backside-illumined CCD as the target anode of a digicon tube of Hubble Space Telescope (HST) design. The CCD digicon tube employs the HST's sodium bialkali photocathode and MgF2 substrate, thereby allowing a direct photocathode quantum efficiency comparison between photocathodes produced by the presently employed low temperature process and those of the conventional high temperature process. Attention is given to the processing chamber used, as well as the details of gas desorption and photocathode processing.

Doliber, D. L.↗

Characterization of Cosmic Grain Analogs Formed at Low Temperature from Small Hydrocarbon Precursors in the NASA Ames COSmIC Facility

Here, we present the results of the first solid-phase ex situ analysis of cosmic grain analogs produced at low temperature (<200 K) in the NASA Ames COsmic SImulation Chamber (COSmIC) from small hydrocarbon precursors, methane (CH4) and acetylene (C2H2), seeded in an argon supersonic jet expansion and submitted to a plasma discharge. The plasma-induced chemical reactions, initiated between the precursor molecules and their atomic and molecular fragments, radicals and ions, produce larger molecules and eventually solid particles that are collected in situ under controlled conditions. Scanning electron microscopy (SEM) imaging was used to provide insight on the morphology and growth structure of the grains produced in COSmIC, and to investigate how the precursors used to produce the grains affect these parameters. This SEM study has shown that under identical experimental conditions with fixed physical and chemical parameters (precursor density, temperature, energy, and reaction time), heavier precursors in the initial mixture produce larger grains and in larger quantity, most likely as a result of a more complex chemistry: most of the grains produced in the Ar/CH4 (95:5) gas mixture ranged from 15 to 385 nm in diameter with an average density of 2.1 grains per sq.μm, while the grains produced in the Ar/C2H2 (95:5) gas mixture ranged from 40 to 650 nm with a density of 3.5 grains per sq.μm. Changes in the morphology were also observed, with grains produced from acetylene (C2H2) precursors tending to be more spherical than grains produced from methane (CH4) precursors. This change in morphology could be associated with different stages of growth formation at low temperature from a more "planar" growth at first, followed by coagulation into more spherical particles. This study demonstrates that the COSmIC experimental setup can be used to investigate carbon grain formation from small gas-phase molecular precursors at low temperature (<200 K), i.e., under a temperature regime that is representative of the dust condensation zone and outer region of circumstellar envelopes.

Ella Sciamma-O'Brien↗

Relationship of dislocation density of silicon to solar cell current loss at low temperature.

Large decreases in short circuit current of silicon solar cells have been reported to occur as temperature is decreased below -60 C. Experimental results are presented which relate high dislocation density of the silicon bulk material of cells to the large current loss effect. These results reveal a direct relationship between low bulk dislocation density and low current loss at low temperature. Oxygen content does not appear to play a significant role in the low temperature-large current loss effect, since some Czochralski cells did not suffer from this effect whereas some float-zone cells did. Other float-zone silicon cells had only medium current losses at low temperature despite their high bulk dislocation density. It appears that use of low-dislocation-density silicon can eliminate the current loss problem in low temperature cell operation.

Mandelkorn, J.↗

Low Temperature Research in Microgravity

The recent flight of the Lambda Point Experiment has demonstrated the potential for performing precise tests of fundamental theories using low temperature techniques in Earth orbit. NASA's Microgravity Science and Applications Division has established a program of successor expermients to investigate other aspects of condensed matter physics using the same low temperature flight facility. This paper describes the new investigations that have been chosen for flight experiments, and those selected for ground-based studies that could lead to flight experiments later.

low temperature microgravity lambda transitition l↗

Low Temperature Microgravity Physics Space Station Facility

A Low Temperature Microgravity Physics Facility under definition for the International Space Station satisfies or exceeds the recommendations of the Science Community and NASA Advisory Boards. LTMPF supports long term multiple experiment modules at low cost with frequent flight opportunities as often as every 20 months.

cryogenic↗