Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Likelihood Functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Observation of Single Top Quark Production and Measurement of |Vtb| with CDF

We report the observation of electroweak single top quark production in 3.2 fb{sup -1} of p{bar p} collision data collected by the Collider Detector at Fermilab at {radical}s = 1.96 TeV. Candidate events in the W+jets topology with a leptonically decaying W boson are classified as signal-like by four parallel analyses based on likelihood functions, matrix elements, neural networks, and boosted decision trees. These results are combined using a super discriminant analysis based on genetically evolved neural networks in order to improve the sensitivity. This combined result is further combined with that of a search for a single top quark signal in an orthogonal sample of events with missing transverse energy plus jets and no charged lepton. We observe a signal consistent with the standard model prediction but inconsistent with the background-only model by 5.0 standard deviations, with a median expected sensitivity in excess of 5.9 standard deviations. We measure a production cross section of 2.3{sub -0.5}{sup +0.6}(stat + sys) pb, extract the CKM matrix element value |V{sub tb}| = 0.91{sub -0.11}{sup +0.11}(stat + sys) {+-} 0.07(theory), and set a lower limit |V{sub tb}| > 0.71 at the 95% confidence level, assuming m{sub t} = 175 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic Bayesian evaluation of resonance parameters in 19 Ne for the 15 O ⁡(𝛼, 𝛾)⁢ 19 Ne and 18 F ⁡(𝑝, 𝛼)⁢ 15 O reactions

Here, we present a comprehensive evaluation of the nuclear structure properties of 19 Ne using a novel and rigorous Bayesian statistical framework. Precise characterization of 19 Ne resonance parameters is critical for accurately determining reaction rates of the astrophysically significant 15 O ⁡(𝛼, 𝛾)⁢ 19 Ne and 18 F ⁡(𝑝, 𝛼)⁢ 15 O reactions, which govern breakout from the hot CNO cycle in x-ray bursts and influence 𝛾-ray emission in novae, respectively. By reconstructing likelihood functions from published experimental data—including asymmetric uncertainties and upper or lower limits—we derive posterior distributions for resonance energies, decay widths, and branching ratios. Our Bayesian approach systematically incorporates previously reported discrepancies among measurements, providing a statistically robust and consistent treatment of these uncertainties. The evaluated resonance parameters and associated uncertainties provide crucial input for stellar nucleosynthesis modeling, contributing to a refined understanding of explosive astrophysical phenomena.

Kim, Sohyun H. [Sungkyunkwan Univ., Suwon (Republi↗

REFMAC5 for the refinement of macromolecular crystal structures

The general principles behind the macromolecular crystal structure refinement program REFMAC5 are described. This paper describes various components of the macromolecular crystallographic refinement program REFMAC5, which is distributed as part of the CCP4 suite. REFMAC5 utilizes different likelihood functions depending on the diffraction data employed (amplitudes or intensities), the presence of twinning and the availability of SAD/SIRAS experimental diffraction data. To ensure chemical and structural integrity of the refined model, REFMAC5 offers several classes of restraints and choices of model parameterization. Reliable models at resolutions at least as low as 4 Å can be achieved thanks to low-resolution refinement tools such as secondary-structure restraints, restraints to known homologous structures, automatic global and local NCS restraints, ‘jelly-body’ restraints and the use of novel long-range restraints on atomic displacement parameters (ADPs) based on the Kullback–Leibler divergence. REFMAC5 additionally offers TLS parameterization and, when high-resolution data are available, fast refinement of anisotropic ADPs. Refinement in the presence of twinning is performed in a fully automated fashion. REFMAC5 is a flexible and highly optimized refinement package that is ideally suited for refinement across the entire resolution spectrum encountered in macromolecular crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transfer Learning-Based Independent Component Analysis

Understanding the underlying component structure is crucial for multivariate signal analysis. Among all the techniques that try to learn the latent structure, independent component analysis (ICA) is one of the most important and popular methods, which aims to extract independent components from multivariate signals and enables further analysis. For example, in electroencephalogram (EEG) analysis, artifacts filtering and disease detection are conducted based on the independent components of the signals. One critical challenge in existing ICA approaches is that the component extraction accuracy may degrade when the available data of a unit are limited. To address this issue, this paper proposes a transfer learning-based ICA method by innovatively transferring component distribution from a source domain, so that accurate component extraction results can be achieved even when only limited data are available in the target domain. To the best of our knowledge, this is the first work that leverages transfer learning to improve ICA accuracy with limited available data. In particular, we first extract all the independent components from the source domain by maximizing the log-likelihood function with a Newton-like method on a smooth manifold. Then for the target domain, the component with the largest negentropy is extracted in each round. To effectively leverage the knowledge from the source domain and to prevent the negative transfer, we try to find a component in the source domain that matches the component we are extracting. The probability density function of the matched component will then be used to improve the component extraction accuracy if such matched component can be found; otherwise, no knowledge will be transferred. Finally, numerical simulations and a case study with electrocardiogram (ECG) data are conducted, showing the effectiveness of the proposed method in transferring knowledge and reducing negative transfer.

42 ENGINEERING↗

Uncertainty analysis of wavelet-based feature extraction for isotope identification on NaI gamma-ray spectra

Low-resolution isotope identifiers are widely deployed for nuclear security purposes, but these detectors currently demonstrate problems in making correct identifications in many typical usage scenarios. While there are many hardware alternatives and improvements that can be made, performance on existing low resolution isotope identifiers should be able to be improved by developing new identification algorithms. We have developed a wavelet-based peak extraction algorithm and an implementation of a Bayesian classifier for automated peak-based identification. The peak extraction algorithm has been extended to compute uncertainties in the peak area calculations. To build empirical joint probability distributions of the peak areas and uncertainties, a large set of spectra were simulated in MCNP6 and processed with the wavelet-based feature extraction algorithm. Kernel density estimation was then used to create a new component of the likelihood function in the Bayesian classifier. Furthermore, identification performance is demonstrated on a variety of real low-resolution spectra, including Category I quantities of special nuclear material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiresolution spatiotemporal mechanical model of the heart as a prior to constrain the solution for 4D models of the heart

In several nuclear cardiac imaging applications (SPECT and PET), images are formed by reconstructing tomographic data using an iterative reconstruction algorithm with corrections for physical factors involved in the imaging detection process and with corrections for cardiac and respiratory motion. The physical factors are modeled as coefficients in the matrix of a system of linear equations and include attenuation, scatter, and spatially varying geometric response. The solution to the tomographic problem involves solving the inverse of this system matrix. This requires the design of an iterative reconstruction algorithm with a statistical model that best fits the data acquisition. The most appropriate model is based on a Poisson distribution. Using Bayes Theorem, an iterative reconstruction algorithm is designed to determine the maximum a posteriori estimate of the reconstructed image with constraints that maximizes the Bayesian likelihood function for the Poisson statistical model. The a priori distribution is formulated as the joint entropy (JE) to measure the similarity between the gated cardiac PET image and the cardiac MRI cine image modeled as a FE mechanical model. In conclusion, the developed algorithm shows the potential of using a FE mechanical model of the heart derived from a cardiac MRI cine scan to constrain solutions of gated cardiac PET images.

60 APPLIED LIFE SCIENCES↗

Using compressive sensing to recover images from PET scanners with partial detector rings

Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

60 APPLIED LIFE SCIENCES↗

Generalized Bayesian MARS: Tools for Stochastic Computer Model Emulation

The multivariate adaptive regression spline (MARS) approach of Friedman and its Bayesian counterpart are effective approaches for the emulation of computer models. The traditional assumption of Gaussian errors limits the usefulness of MARS, and many popular alternatives, when dealing with stochastic computer models. Here, we propose a generalized Bayesian MARS (GBMARS) framework which admits the broad class of generalized hyperbolic distributions as the induced likelihood function. This allows us to develop tools for the emulation of stochastic simulators which are parsimonious, scalable, and interpretable and require minimal tuning, while providing powerful predictive and uncertainty quantification capabilities. GBMARS is capable of robust regression with t distributions, quantile regression with asymmetric Laplace distributions, and a general form of “Normal-Wald” regression in which the shape of the error distribution and the structure of the mean function are learned simultaneously. We demonstrate the effectiveness of GBMARS on various stochastic computer models, and we show that it compares favorably to several popular alternatives.

97 MATHEMATICS AND COMPUTING↗

Frequentist Analysis of the Parameter Space of Minimal Supergravity

We make a frequentist analysis of the parameter space of minimal supergravity (mSUGRA), in which, as well as the gaugino and scalar soft supersymmetry-breaking parameters being universal, there is a specific relation between the trilinear, bilinear and scalar supersymmetry-breaking parameters, A_0 = B_0 + m_0, and the gravitino mass is fixed by m_{3/2} = m_0. We also consider a more general model, in which the gravitino mass constraint is relaxed (the VCMSSM). We combine in the global likelihood function the experimental constraints from low-energy electroweak precision data, the anomalous magnetic moment of the muon, the lightest Higgs boson mass M_h, B physics and the astrophysical cold dark matter density, assuming that the lightest supersymmetric particle (LSP) is a neutralino. In the VCMSSM, we find a preference for values of m_{1/2} and m_0 similar to those found previously in frequentist analyses of the constrained MSSM (CMSSM) and a model with common non-universal Higgs masses (NUHM1). On the other hand, in mSUGRA we find two preferred regions: one with larger values of both m_{1/2} and m_0 than in the VCMSSM, and one with large m_0 but small m_{1/2}. We compare the probabilities of the frequentist fits in mSUGRA, the VCMSSM, the CMSSM and the NUHM1: the probability that mSUGRA is consistent with the present data is significantly less than in the other models. We also discuss the mSUGRA and VCMSSM predictions for sparticle masses and other observables, identifying potential signatures at the LHC and elsewhere.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs and Supersymmetry

Global frequentist fits to the CMSSM and NUHM1 using the MasterCode framework predicted m_h \simeq 119 GeV in fits incorporating the g_mu-2 constraint and \simeq 126 GeV without it. Recent results by ATLAS and CMS could be compatible with a Standard Model-like Higgs boson around m_h \simeq 125 GeV. We use the previous MasterCode analysis to calculate the likelihood for a measurement of any nominal Higgs mass within the range of 115 to 130 GeV. Assuming a Higgs mass measurement at m_h \simeq 125 GeV, we display updated global likelihood contours in the (m_0, m_{1/2}) and other parameter planes of the CMSSM and NUHM1, and present updated likelihood functions for m_gluino, m_squark, B to mu mu, and the spin-independent dark matter cross section \sigma^si. The implications of dropping g_mu-2 from the fits are also discussed. We furthermore comment on a hypothetical measurement of m_h \simeq 119 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NUHM2 after LHC Run 1

We make a frequentist analysis of the parameter space of the NUHM2, in which the soft supersymmetry (SUSY)-breaking contributions to the masses of the two Higgs multiplets, m 2 H u,d , vary independently from the universal soft SUSY-breaking contributions m 2 0 to the masses of squarks and sleptons. Our analysis uses the MultiNest sampling algorithm with over 4 × 10⁸ points to sample the NUHM2 parameter space. It includes the ATLAS and CMS Higgs mass measurements as well as the ATLAS search for supersymmetric jets + /E T signals using the full LHC Run 1 data, the measurements of BR(B s →μ⁺μ⁻) by LHCb and CMS together with other B-physics observables, electroweak precision observables and the XENON100 and LUX searches for spin-independent dark-matter scattering. We find that the preferred regions of the NUHM2 parameter space have negative SUSY-breaking scalar masses squared at the GUT scale for squarks and sleptons, m 2 0 < 0, as well as m 2 H u < m 2 H d < 0. The tension present in the CMSSM and NUHM1 between the supersymmetric interpretation of (g – 2)μ and the absence to date of SUSY at the LHC is not significantly alleviated in the NUHM2. We find that the minimum χ 2 = 32.5 with 21 degrees of freedom (dof) in the NUHM2, to be compared with χ 2 /dof = 35.0/23 in the CMSSM, and χ 2 /dof = 32.7/22 in the NUHM1. We find that the one-dimensional likelihood functions for sparticle masses and other observables are similar to those found previously in the CMSSM and NUHM1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The pMSSM10 after LHC run 1

We present a frequentist analysis of the parameter space of the pMSSM10, in which the following ten soft SUSY-breaking parameters are specified independently at the mean scalar top mass scale M SUSY ≡ √m $\tilde{t}$ 1 m $\tilde{t}$ 2 : the gaugino masses M 1,2,3 , the first-and second-generation squark masses m $\tilde{q}$ 1 = m $\tilde{q}$ 2 , the third-generation squark mass m $\tilde{q}$ 3 , a common slepton mass m $\tilde{ℓ}$ and a common trilinear mixing parameter A , as well as the Higgs mixing parameter μ , the pseudoscalar Higgs mass M A and tanβ , the ratio of the two Higgs vacuum expectation values. We use the MultiNest sampling algorithm with ~ 1.2 ×10 9 points to sample the pMSSM10 parameter space. A dedicated study shows that the sensitivities to strongly interacting sparticle masses of ATLAS and CMS searches for jets, leptons + E-slash T signals depend only weakly on many of the other pMSSM10 parameters. With the aid of the Atom and Scorpion codes, we also implement the LHC searches for electroweakly interacting sparticles and light stops, so as to confront the pMSSM10 parameter space with all relevant SUSY searches. In addition, our analysis includes Higgs mass and rate measurements using the HiggsSignals code, SUSY Higgs exclusion bounds, the measurements of BR(B s →μ + μ - ) by LHCb and CMS, other B -physics observables, electroweak precision observables, the cold dark matter density and the XENON100 and LUX searches for spin-independent dark matter scattering, assuming that the cold dark matter is mainly provided by the lightest neutralino χ-tilde 1 0 . We show that the pMSSM10 is able to provide a supersymmetric interpretation of (g-2) μ , unlike the CMSSM, NUHM1 and NUHM2. As a result, we find (omitting Higgs rates) that the minimum χ2=20.5 with 18 degrees of freedom (d.o.f.) in the pMSSM10, corresponding to a χ2 probability of 30.8 %, to be compared with χ2/d.o.f.=32.8/24(31.1/23)(30.3/22) in the CMSSM (NUHM1) (NUHM2). We display the one-dimensional likelihood functions for sparticle masses, and we show that they may be significantly lighter in the pMSSM10 than in the other models, e.g., the gluino may be as light as ~ 1250 GeV at the 68 % CL, and squarks, stops, electroweak gauginos and sleptons may be much lighter than in the CMSSM, NUHM1 and NUHM2. We discuss the discovery potential of future LHC runs, e + e - colliders and direct detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the top quark mass in the all-jets final state at $\sqrt{s}=13\,\text {TeV} $ TeV and combination with the lepton+jets channel

A top quark mass measurement is performed using $35.9{\,\text {fb}^{-1}} $ of LHC proton–proton collision data collected with the CMS detector at $\sqrt{s}=13\,\text {TeV} $. The measurement uses the ${\mathrm {t}\overline{\mathrm {t}}}$ all-jets final state. A kinematic fit is performed to reconstruct the decay of the ${\mathrm {t}\overline{\mathrm {t}}}$ system and suppress the multijet background. Using the ideogram method, the top quark mass ( $m_{\mathrm {t}}$ ) is determined, simultaneously constraining an additional jet energy scale factor ( $\text {JSF}$ ). The resulting value of $m_{\mathrm {t}} =172.34\pm 0.20\,\text {(stat+JSF)} \pm 0.70\,\text {(syst)} \,\text {GeV} $ is in good agreement with previous measurements. In addition, a combined measurement that uses the ${\mathrm {t}\overline{\mathrm {t}}}$ lepton+jets and all-jets final states is presented, using the same mass extraction method, and provides an $m_{\mathrm {t}}$ measurement of $172.26\pm 0.07\,\text {(stat+JSF)} \pm 0.61\,\text {(syst)} \,\text {GeV} $ . This is the first combined $m_{\mathrm {t}}$ extraction from the lepton+jets and all-jets channels through a single likelihood function.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global analysis of dark matter simplified models with leptophobic spin-one mediators using MasterCode

Abstract We report the results of a global analysis of dark matter simplified models (DMSMs) with leptophobic mediator particles of spin one, considering the cases of both vector and axial-vector interactions with dark matter (DM) particles and quarks. We require the DMSMs to provide all the cosmological DM density indicated by Planck and other observations, and we impose the upper limits on spin-independent and -dependent scattering from direct DM search experiments. We also impose all relevant LHC constraints from searches for monojet events and measurements of the dijet mass spectrum. We model the likelihood functions for all the constraints and combine them within the framework, and probe the full DMSM parameter spaces by scanning over the mediator and DM masses and couplings, not fixing any of the model parameters. We find, in general, two allowed regions of the parameter spaces: one in which the mediator couplings to Standard Model (SM) and DM particles may be comparable to those in the SM and the cosmological DM density is reached via resonant annihilation, and one in which the mediator couplings to quarks are $$\lesssim \, 10^{-3}$$ ≲ 10 - 3 and DM annihilation is non-resonant. We find that the DM and mediator masses may well lie within the ranges accessible to LHC experiments. We also present predictions for spin-independent and -dependent DM scattering, and present specific results for ranges of the DM couplings that may be favoured in ultraviolet completions of the DMSMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal WIMPs and the scale of new physics: global fits of Dirac dark matter effective field theories

We assess the status of a wide class of WIMP dark matter (DM) models in light of the latest experimental results using the global fitting framework GAMBIT. We perform a global analysis of effective field theory (EFT) operators describing the interactions between a gauge-singlet Dirac fermion and the Standard Model quarks, the gluons and the photon. In this bottom-up approach, we simultaneously vary the coefficients of 14 such operators up to dimension 7, along with the DM mass, the scale of new physics and several nuisance parameters. Our likelihood functions include the latest data from Planck, direct and indirect detection experiments, and the LHC. For DM masses below 100 GeV, we find that it is impossible to satisfy all constraints simultaneously while maintaining EFT validity at LHC energies. For new physics scales around 1 TeV, our results are influenced by several small excesses in the LHC data and depend on the prescription that we adopt to ensure EFT validity. Furthermore, we find large regions of viable parameter space where the EFT is valid and the relic density can be reproduced, implying that WIMPs can still account for the DM of the universe while being consistent with the latest data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurements of the {rho}{sup 3} spin density matrix elements in {gamma}p --> p {omega} using CLAS at JLAB

In an effort towards a ''complete'' experiment for the ω meson, we present studies from an experiment with an unpolarized target and a circularly polarized photon beam (g1c), carried out using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The experiment was analyzed using an extended maximum likelihood fit with partial wave amplitudes. New likelihood functions were calculated to account for the polarization of the photon beam. Both circular and linear polarizations are explored. The results of these fits are then used to project out the spin density matrix for the {omega}. First measurements of the {rho}{sup 3} spin density matrix elements will be presented using this method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Integration of multiscale environmental data

The software is designed for efficiently integrating large-size of multi-scale environmental data using the Bayesian framework. Suppose we need to estimate the spatial distribution of variable X with high spatial resolution. The available data include (1) direct measurements Z of the unknowns with high resolution in a subset of the spatial domain (small spatial coverage), (2) measurements C of the unknowns at the median scale, and (3) measurements A of the unknowns at the coarsest scale but with large spatial coverage. The goal is to estimate the unknowns at the fine grids by conditioning to all the available data. We first consider all the unknowns as random variables and estimate conditional probability distribution of those variables by conditioning to the limited high-resolution observations (Z). We then treat the estimated probability distribution as the prior distribution. Within the Bayesian framework, we combine the median and large-scale measurements (C and A) through likelihood functions. Since we assume that all the relevant multivariate distributions are Gaussian, the resulting posterior distribution is a multivariate Gaussian distribution. The developed software provides numerical solutions of the posterior probability distribution. The software can be extended in several different ways to solve more general multi-scale data integration problems.

CHEN, JINSONG↗