Demonstration of Safe Termination of Megaampere Relativistic Electron Beams in Tokamaks
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
The National Spherical Torus eXperiment (NSTX) has undergone a major upgrade to NSTX-U at Princeton Plasma Physics Laboratory (PPPL). NSTX upgrade (NSTX-U) will double the toroidal field, plasma current, and neutral beam injection heating power, as well as significantly increase the pulse duration. NSTX-U uses three poloidal field (PF) coils at the vessel top and three at the bottom near the divertor areas to control the local plasma shape there. These shaping coils operate at a maximum terminal voltage of 2 kV, corresponding to a maximum current about 20 kA. To supply the power to the PF coils, hard copper bus bars are typically used near the vacuum vessel, while water cooled flexible cables are used away from the vessel. The detailed design of the hard copper bus bars will be covered in this article. During operation, these hard bus bars are subject to high electromagnetic (EM) forces, thermal displacement loads, as well as plasma halo loads due to disruption. The EM, thermal, and structural analysis were performed, and the results revealed that, with the worst loads combined, the new design meets the NSTX-U thermal, structural, and fatigue cycle requirements. Finally, the manufacturing and installation process of the bus work will be discussed at the end of this article.
We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3–5−μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5–19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si 𝐾-shell spectra were 148 ± 4 eV and 8.6 ±1.4 × 10 21 cm −3 , respectively. Six experiments showed opacity reproducibility within ±15% and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.
Explore the source record for details and available documents.
We report that in steady state, the fuel cycle of a fusion plasma requires inward particle fluxes of fuel ions. These particle flows are also accompanied by heating. In the case of classical transport in a rotating cylindrical plasma, this heating can proceed through several distinct channels depending on the physical mechanisms involved. Some channels directly heat the fuel ions themselves, whereas others heat electrons. Which channel dominates depends, in general, on the details of the temperature, density and rotation profiles of the plasma constituents. However, remarkably, under relatively few assumptions concerning these profiles, if the α particles, the by-products of the fusion reaction, can be removed directly by other means, then a hot-ion mode tends to emerge naturally.
A novel plasma equilibrium in the high-β, Hall regime that produces centrally peaked, high Mach number Couette flow is described. Flow is driven using a weak, uniform magnetic field and large, cross field currents. Large magnetic field amplification (factor 20) due to the Hall effect is observed when electrons are flowing radially inward, and near perfect field expulsion is observed when the flow is reversed. In conclusion, a dynamic equilibrium is reached between the amplified (removed) field and extended density gradients.
Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.
Opacity model differences with Fe opacity measurements at high temperature (T>180 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.
Dear JLF community, I cannot believe I am now entering my third year as JLF director — time definitely flies when you are having fun! FY25 was another pivotal year for the Jupiter Laser Facility, marked by both scientific achievement and growing visibility for our community. Building on the successful reopening and refurbishment of the facility, we continued to demonstrate how JLF drives innovation in high energy density and fusion energy science, laser technology, and workforce development. Across Janus, Titan, and COMET, users executed a diverse portfolio of experiments, from dynamic compression and opacity measurements to laser plasma interactions, laboratory astrophysics, and advanced diagnostics. These efforts are highlighted in this report, including the development of new probes that capture the time evolution of plasmas on a single shot, and diagnostics and platforms that are already impacting experiments at NIF and other large facilities. JLF continues to serve as both a testbed for new ideas and a bridge to larger scale campaigns. FY25 also showcased the broader role of JLF within the Laboratory and the national HED science ecosystem. The NIF JLF User Groups Meeting in February brought nearly 180 participants to Livermore and highlighted the scientific progress made during JLF’s first full year of renewed operations. JLF research and users were recognized with Director’s Institutional Awards and Early and Mid Career awards, underscoring the quality and impact of the work performed here. Our team also contributed prominently to national conversations about laser safety, plasma physics, and inertial fusion energy through invited talks, conferences, and professional society leadership. JLF’s integration with LaserNetUS deepened this year as well. We launched a new technical exchange program across LaserNetUS facilities and kicked it off with a JLF team visit to the BELLA Center at Lawrence Berkeley National Laboratory. These exchanges are strengthening operations, sharing best practices, and improving the user experience across the network. Filming for the LaserNetUS “Behind the Scenes” series and participation in the annual LaserNetUS meeting further increased the visibility of our facility and our users. At the same time, JLF continues to play a central role in ambitious new programs, such as the Big Aperture Thulium laser effort funded through one of the DOE Office of Science Microelectronics Science Research Centers, which will use JLF infrastructure to explore next generation high rep rate lasers for EUV and x-ray source development. A core part of our mission remains training the next generation of scientists. In FY25, we welcomed another cohort of summer students, who joined experimental teams on Titan and presented their research at LLNL’s student poster symposium and national inertial fusion energy meetings. JLF users and early career scientists showcased their work at conferences across the country, highlighting experiments performed at the facility. These hands on experiences, and the mentoring provided by our staff and user teams, are central to JLF’s identity as a true user facility. Finally, FY25 reinforced JLF’s role as a focal point for partnerships and outreach. We hosted visits from international collaborators, science leaders, and we shared the story of the facility through venues such as the Big Ideas Lab podcast. These interactions help connect our work to a broader scientific and policy audience and open new pathways for collaboration. As we look ahead, the combination of refurbished hardware, new capabilities like STILETTO and enhanced short pulse performance on Titan, strong partnerships across LLNL and LaserNetUS, and a growing user community positions JLF for an even more ambitious program in the coming years. I am deeply grateful to our technical and operations staff for their dedication, to our LLNL partners for their continued support, and to our users for bringing bold, creative ideas to the facility. I look forward to more experiments, capabilities, partnerships, and groundbreaking science in the years to come! With brightest regards, Félicie Albert, JLF Director.
A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.
We report in laser-produced high-energy-density plasmas, large-scale strong magnetic fields are spontaneously generated by the Biermann battery effects when temperature and density gradients are misaligned. Saturation of the magnetic field takes place when convection and dissipation balance field generation. While theoretical and numerical modeling provide useful insight into the saturation mechanisms, experimental demonstration remains elusive. In this letter, we report an experiment on the saturation dynamics and scaling of Biermann battery magnetic field in the regime where plasma convection dominates. With time-gated charged-particle radiography and time-resolved Thomson scattering, the field structure and evolution as well as corresponding plasma conditions are measured. In these conditions, the spatially resolved magnetic fields are reconstructed, leading to a picture of field saturation with a scaling of $B ~ 1/L_T$ for a convectively dominated plasma, a regime where the temperature gradient scale ($L_T$) exceeds the ion skin depth.
This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. The results of PPPL’s 2021 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2021. PPPL’s on-site operations were significantly curtailed in 2021 due to the global coronavirus pandemic. PPPL has engaged in fusion energy research since 1951. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the U.S. and the world, and to developing the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2021. PPPL is engaged in a project to replace key NSTX-U components and systems to enable operation of this international fusion user facility. In 2021, PPPL’s radiological environmental monitoring program measured tritium in the air at the NSTX-U Stack and at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of an in-stack monitor located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2021, PPPL complied with permit limits for surface and sanitary discharges. PPPL was honored with awards for EPEAT-certified electronics purchasing and use of peracetic acid as an alternative water treatment chemical in its non-potable process water systems an NJDEP recycling award.
The DOE award No. DE-SC0019153, supported in part one graduate student (J. Olson) and material expenses, enabling the student to prepare a basic plasma physics experiment on magnetic reconnection (which we now call the Terrestrial Reconnection Experiment, TREX) within at the Wisconsin Plasma Physics Laboratory (WiPPL). The study of the collisionless magnetic reconnection constituted the primary research carried out under this grant and lead to new observations of unexpected shock formation below the TREX reconnection layer. The shock formation was found fundamental to regulating the normalized rate of reconnection, and the results were part of our experimental observations detailed in a paper first authored by Dr. J. Olson and now published in the Journal of Plasma Physics. In this Report we review the general motivation of this work and provide an overview of our experimental results enabled by the support through the award.
A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.
In experiments performed with the OMEGA EP laser system, proton deflectometry captured magnetic field dynamics consistent with collisionless shock formation driven by strongly magnetized relativistic electrons. During laser-foil interactions, shocks can form as relativistic electrons and strong surface magnetic fields generated by a short-pulse laser impinge on a cooler plasma produced by a longer-pulse laser. Three-dimensional particle-in-cell simulations reproduce the magnetic draping and fast formation speeds measured in the experiment and reveal that this relativistic-electron-driven shock forms at an interface that is unstable to shear and streaming instabilities. The simulation results provide insight into the microphysics that may influence high-energy shocks observed in extreme astrophysical environments. Published by the American Physical Society 2024
The overarching goal of this research is to advance the fundamental understanding of plasma-driven chemical conversion of light hydrocarbons using dielectric barrier discharges (DBDs). Using methane (CH 4 ) as a model system, the primary focus is to elucidate the influence of DBD plasma properties and environmental temperature on CH 4 plasma chemistry by studying decomposition products of the gas effluent across a broad range of conditions using experimental instrumentation at the Princeton Collaborative Research Facility (PCRF) located at the Princeton Plasma Physics Laboratory (PPPL). The insights obtained from this study are expected to form the mechanistic foundation for the design and optimization of plasma-catalytic reactions of light hydrocarbons for practical applications such as the recycling of production flare gas by transforming the uncaptured waste into value-added resources at the source of extraction, presenting a sustainable solution to a longstanding environmental challenge.
Understanding plasma self-magnetization is one of the fundamental challenges in both laboratory and astrophysical plasmas. Self-magnetization can modify plasma transport properties, altering the dynamical evolution of plasmas. Multiple high-energy-density (HED) experiments have observed the formation of ion-scale magnetic filaments of megagauss strength, though their origin remains debated. Here, in this study, we conduct 2D collisional particle-in-cell (PIC) simulations with a laser ray-tracing module for a fully self-consistent simulation of the plasma ablation, expansion, and magnetization. The simulations use a planar geometry, effectively suppressing the Biermann magnetic fields, to focus on anisotropy-driven instabilities. The laser intensity is varied between 10 13 and 10 14 W/cm 2 , which is relevant to HED and inertial fusion experiments where collisions must be considered. We find that, above a critical intensity, the plasma rapidly self-magnetizes via an expansion-driven Weibel process, producing a plasma beta of 100 (𝛽 = 8𝜋𝑘 𝐵 𝑛 𝑒 𝑇 𝑒 /𝐵 2 ) and Hall parameter 𝜔 ce 𝜏 𝑒 >1 within the first few hundred picoseconds. The magnetic field is sufficiently strong to modify plasma heat transport, and simulations with an artificially suppressed magnetic field show noticeably different temperature profiles.