Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOCATION CLOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Expansion analyses of strategic petroleum reserve in Bayou Choctaw : revised locations.

This report summarizes a series of three-dimensional simulations for the Bayou Choctaw Strategic Petroleum Reserve. The U.S. Department of Energy plans to leach two new caverns and convert one of the existing caverns within the Bayou Choctaw salt dome to expand its petroleum reserve storage capacity. An existing finite element mesh from previous analyses is modified by changing the locations of two caverns. The structural integrity of the three expansion caverns and the interaction between all the caverns in the dome are investigated. The impacts of the expansion on underground creep closure, surface subsidence, infrastructure, and well integrity are quantified. Two scenarios were used for the duration and timing of workover conditions where wellhead pressures are temporarily reduced to atmospheric pressure. The three expansion caverns are predicted to be structurally stable against tensile failure for both scenarios. Dilatant failure is not expected within the vicinity of the expansion caverns. Damage to surface structures is not predicted and there is not a marked increase in surface strains due to the presence of the three expansion caverns. The wells into the caverns should not undergo yield. The results show that from a structural viewpoint, the locations of the two newly proposed expansion caverns are acceptable, and all three expansion caverns can be safely constructed and operated.

02 PETROLEUM↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 572: Test Cell C Ancillary Building and Structures - Nevada National Security Site, Nevada with ROTC 1

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 572, Test Cell C Ancillary Building and Structures, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 572 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada National Security Site: CAS 25-33-01, Building 3220, Equipment Building; CAS 25-33-02, Building 3230, Motor Drive Building; CAS 25-33-03, Building 3231, Pump House; CAS 25-33-04, Building 3232, Cryogenic Evaluation Lab; CAS 25-99-22, Ancillary Facilities. This plan provides the methodology for field activities needed to gather the necessary information for closing CAU 572. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 572 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. The purpose of the corrective action investigation (CAI) will be to document and verify the adequacy of existing information; to affirm the decision for either clean closure, closure in place, or no further action; and to provide sufficient data to implement the corrective action. The actual corrective action selected will be based on characterization activities implemented under this SAFER Plan. If it is determined that complete clean closure cannot be accomplished during the CAI, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place. This will be presented in a closure report that will be prepared and submitted to NDEP for review and approval.

54 ENVIRONMENTAL SCIENCES↗

Closure Plan for the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch

The Materials and Fuels Complex industrial waste system currently consists of the Industrial Waste Pond and Industrial Waste Ditch, associated piping, lift station, and flow meter. The Industrial Waste Pond and Industrial Waste Ditch, are land application sites permitted under Idaho Department of Environmental Quality Reuse Permit I-160-02, Modification 1. The Reuse Permit allows for 17 million gallons of industrial wastewater to be discharged to the land application sites. For Reuse Permit year 2017, approximately 7.569 million gallons were discharged to the land application sites, of which 1.649 million gallons were discharged to the Industrial Waste Ditch. A project (MFC West Campus Utility Corridor project) is proposed to begin in the summer of 2018. The project will install a new utility corridor along the west and north sides of the Materials and Fuels Complex. As part of the design, it is proposed to reroute the wastewater currently discharged to the Industrial Waste Ditch into an underground pipe that would connect into the existing Industrial Waste Pipeline. The Industrial Waste Ditch pipe would enter the existing Industrial Waste Pipeline upstream of the existing flow meter and sampling location. This would allow for the combined wastewater streams to be monitored for flow and sampled for parameters required by the Reuse Permit. In accordance with the Reuse Permit, this closure plan is being submitted to the Idaho Department of Environmental Quality for review and approval. Once the closure plan is approved, the Reuse Permit will be modified to remove the Industrial Waste Ditch from the permit. The closure plan includes: • Brief background of the Materials and Fuels Complex. • Reuse Permit history. • Site characteristics. • Description of the Industrial Wastewater System. • History of discharges to the Industrial Waste Ditch. • Summary of the Comprehensive Environmental Response, Compensation, and Liability Act characterization, evaluation, and remediation of the Industrial Waste Ditch. • Contaminant concentrations in the effluent discharged to the Industrial Waste Ditch. • Contaminant concentrations in cross gradient, downgradient, and background monitoring wells. Based on the Comprehensive Environmental Response, Compensation, and Liability Act characterization and remediation of the Industrial Waste Ditch, low volumes and contaminant concentrations in the effluent subsequently discharged to the Industrial Waste Ditch, and contaminant concentrations at or near background levels in the monitoring wells, it is recommended that the Industrial Waste Ditch should be closed without further characterization.

99 GENERAL AND MISCELLANEOUS↗

Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaussian process hydrodynamics

Abstract We present a Gaussian process (GP) approach, called Gaussian process hydrodynamics (GPH) for approximating the solution to the Euler and Navier-Stokes (NS) equations. Similar to smoothed particle hydrodynamics (SPH), GPH is a Lagrangian particle-based approach that involves the tracking of a finite number of particles transported by a flow. However, these particles do not represent mollified particles of matter but carry discrete/partial information about the continuous flow. Closure is achieved by placing a divergence-free GP prior ξ on the velocity field and conditioning it on the vorticity at the particle locations. Known physics (e.g., the Richardson cascade and velocity increment power laws) is incorporated into the GP prior by using physics-informed additive kernels. This is equivalent to expressing ξ as a sum of independent GPs ξ l , which we call modes, acting at different scales (each mode ξ l self-activates to represent the formation of eddies at the corresponding scales). This approach enables a quantitative analysis of the Richardson cascade through the analysis of the activation of these modes, and enables us to analyze coarse-grain turbulence statistically rather than deterministically. Because GPH is formulated by using the vorticity equations, it does not require solving a pressure equation. By enforcing incompressibility and fluid-structure boundary conditions through the selection of a kernel, GPH requires significantly fewer particles than SPH. Because GPH has a natural probabilistic interpretation, the numerical results come with uncertainty estimates, enabling their incorporation into an uncertainty quantification (UQ) pipeline and adding/removing particles (quanta of information) in an adapted manner. The proposed approach is suitable for analysis because it inherits the complexity of state-of-the-art solvers for dense kernel matrices and results in a natural definition of turbulence as information loss. Numerical experiments support the importance of selecting physics-informed kernels and illustrate the major impact of such kernels on the accuracy and stability. Because the proposed approach uses a Bayesian interpretation, it naturally enables data assimilation and predictions and estimations by mixing simulation data and experimental data.

Mathematics↗

Searching for Hyperspectral Optical Proxies to Aid Chesapeake Bay Resource Managers in the Detection of Poor Water Quality

Shellfish aquaculture is a growing industry in the Chesapeake Bay. As population grows near the coast, extreme weather events cause a greater volume of pollutant runoff from impervious surfaces and agricultural lands. Resource managers who monitor shellfish beds need reliable information on a variety of water quality indicators at higher frequency than is possible through field monitoring programs and at a higher level of detail than current satellite products can provide. Although many factors causing degraded water quality that can impact human health are not currently discernable by traditional multispectral techniques, hyperspectral imagery offers a new opportunity to detect phytoplankton communities associated with harmful algal blooms and biotoxin production. Together with resource managers in their routine monitoring of sites around the bay from small boats, we have been exploring remotely sensed optical proxies for the detection of harmful algal blooms and sewage. Early warning by remote sensing could guide sampling and improve the efficiency of shellfish bed closures, ultimately improving health outcomes for humans and animals. An extensive network of routine sampling by Chesapeake Bay Program managers makes this is an ideal location to develop and test future satellite data products to support management decisions. Next generation hyperspectral measurements from the future Plankton Aerosol Cloud ocean Ecosystem (PACE) mission at nearly daily frequency, combined with the potential of higher spatial resolution from the Surface Biology and Geology (SBG) observing system recommended in the recent Decadal Survey, along with high frequency observations from the newly selected Geostationary Littoral Imaging and Monitoring Radiometer (GLIMR) Earth Venture Instrument make this a critical time for defining the needs of the aquaculture and resource management community to save lives, time, and money.

Schollaert Uz, Stephanie↗

Deployment of a 3D Sonar System at Savannah River: Results, Implications and Next Steps - 19718

Waste solids mapping is required at SRS to support the closure of high level radioactive waste tanks. The current mapping methodologies utilize a combination of video inspections and still camera photos to record the solids location and height in the tank with interpretation by site Engineering personnel. Tank liquid level is recorded during capture of the images to determine the height of solids. If no liquid is present, the images are compared to known waste tank features (e.g., cooling coils, support columns) to determine the height of the solids. In December of 2017, NuVision Engineering and Fortis Engineering conducted a demonstration of Sonar technology in SRS F-Tank Farm (FTF) Tank 7 using three risers (Risers 1, 5, and Center) for the purposes of mapping waste solids in the tank. Tank 7 was not the ideal choice for a 'first-of-a-kind' deployment given its congested internals but was selected based on the priority of tank farm operations. Savannah River Remediation (SRR) evaluated the results of this demonstration against the current solids mapping methodologies to determine potential future application of Sonar technology to support upcoming sludge or salt waste removal, decisions to cease waste removal and perform sampling and analysis, final residuals volume determinations, and applicability for use in H-Tank Farm (HTF) Type IV tanks. The efficiency of the Sonar mapping technology against the current mapping techniques and the relative costs of each were also evaluated. The Sonar demonstration performed in the three risers of Tank 7 resulted in a tank floor coverage of approximately 26%. This limited coverage was primarily due to shadow effects and image distortions created by vertical cooling coils and support columns within the waste tank. A comparison of the images produced during the Sonar demonstration and the historical Tank 7 mapping, performed in 2011 upon completion of Bulk Waste Removal Efforts (BWRE), showed physical similarities between the mounds located near the Sonar deployment risers. The technology performed well in accurately mapping solids in those areas accessible to coverage. The Sonar mapping technology may achieve more benefits if configured to work around internal obstructions, or in a Type IV tank, where the lack of vertical cooling coils may allow for a larger coverage area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the mechanisms responsible for the lack of surface energy balance closure in a central Amazonian tropical rainforest

This work investigates the diurnal and seasonal behavior of the energy balance residual (E) that results from the observed difference between available energy and the turbulent fluxes of sensible heat (H) and latent heat (LE) at the FLUXNET BR-Ma2 site located in the Brazilian central Amazon rainforest. The behavior of E is analyzed by extending the eddy covariance averaging length from 30 min to 4 h and by applying an Information Flow Dynamical Process Network to diagnose processes and conditions affecting E across different seasons. Results show that the seasonal turbulent flux dynamics and the Bowen ratio are primarily driven by net radiation (R n ), with substantial sub-seasonal variability. The Bowen ratio increased from 0.25 in April to 0.4 at the end of September. Extension of the averaging length from 0.5 (94.6% closure) to 4 h and thus inclusion of longer timescale eddies and mesoscale processes closes the energy balance and lead to an increase in the Bowen ratio, thus highlighting the importance of additional H to E. Information flow analysis reveals that the components of the energy balance explain between 25 and 40% of the total Shannon entropy with higher values during the wet season than the dry season. Dry season information flow from the buoyancy flux to E are 30–50% larger than that from H, indicating the potential importance of buoyancy fluxes to closing E. While the low closure highlights additional sources not captured in the flux data and random measurement errors contributing to E, the findings of the information flow and averaging length analysis are consistent with the impact of mesoscale circulations, which tend to transport more H than LE, on the lack of closure.

54 ENVIRONMENTAL SCIENCES↗

Technology Basis for Savannah River Tank Closure Cesium Removal Project - 17448

Westinghouse is currently executing a contract, awarded in June 2016 from Savannah River Remediation LLC, to deliver a system capable of removing solids and up to 100,000 curies of Cesium-137 from tank 10H, located in the Savannah River 'tank farm'. Savannah River Remediation currently has the responsibility to perform work for the Savannah River Site Liquid Waste Operations Program at the Savannah River Site for the US government, represented by the US DOE under their Principal contract. The scope of work covers the detailed design, procurement, fabrication, and delivery of the system to the Savannah River Site. It also includes the factory acceptance testing of the system, prior to delivery to site. Before leaving the site, Westinghouse will perform an evaluation of the system assembly and operations training for the incumbent operator. The basis for the technology chosen to accomplish the solids and Cesium-137 removal is unique to the specific feed stream, but is based on well-known and successful technology, Toshiba SARRY water cleanup system. Toshiba is Westinghouse's parent company, allowing us to reach back and incorporate the lessons learned during the water cleanup at Fukushima Daiichi and the integration of various technologies. Another key to the technology basis was the ion exchange media selection. A number of possible ion exchange media for the cesium removal were considered with the final choice being inorganic CST resin. Several criteria were considered and compared, such as the radiation sensitivity of the CST and the cesium specific ion preference. This paper will present the conceptual design of the modular system, noting the key benefits of specific components in the overall technology basis. Along with the design, a look at key technology improvements carried into the design through the Toshiba SARRY system will be incorporated. A first feedback on the implementation of the overall project will be provided. Since this system is a first-of-a-kind in this specific application, interesting lessons learned will be provided for future tank closure activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada (CY2021, Revision 0)

This report includes visual inspection results, maintenance and repair activities, and recommendations for calendar year (CY) 2021 for use restrictions (URs) at corrective action sites (CASs) located on the Nevada National Security Site (NNSS) and on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. This document is formatted by project activity (i.e., Industrial Sites, Soils, and Defense Threat Reduction Agency [DTRA]); then by corrective action unit (CAU); and then by CAS.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the MHD stability and energetic particles effects on EIC events in LHD plasma using a Landau-closure model

The aim of this study is to perform a theoretical analysis of the magnetohydrodynamic (MHD) stability and energetic particle effects on a LHD equilibria, calculated during a discharge where energetic-ion-driven resistive interchange mode (EIC) events were triggered. Here, we use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles species, including the effect of the acoustic modes, multiple energetic particles (EP) species, helical couplings and helically trapped EP. We add the Landau damping and resonant destabilization effects using a closure relation. The simulations suggest that the helically trapped EP driven by the perpendicular neutral beam injector (NBI) further destabilizes the 1/1 MHD-like mode located at the plasma periphery ( r / a = 0.88). If the β of the EP driven by the perpendicular NBI is larger than 0.0025 a 1/1 EIC with a frequency around 3 kHz is destabilized. If the effect of the passing EP driven by the tangential NBI is included on the model, any enhancement of the injection intensity of the tangential NBI below β leads to a decrease of the instability growth rate. The simulations indicate that the perpendicular NBI EP is the main driver of the EIC events, as it was observed in the experiment. If the effect of the helical couplings are added in the model, an 11/13 EIC is destabilized with a frequency around 9 kHz, inward shifted ( r / a = 0.81) compared to the 1/1 EIC. Thus, one possible explanation for the EIC frequency chirping down from 9 to 3 kHz is a transition between the 11/13 to the 1/1 EIC due to a weakening of the destabilizing effect of the high n modes, caused by a decrease of the EP drive due to a loss of helically trapped EP or a change in the EP distribution function after the EIC burst. The experimental data during the EIC bursting phase shows a complex mode structure and an inward shift of the instability, although no direct evidence of the proposed transition has been observed yet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NESHAP Area-Specific Dose-Release Factors for Potential Onsite Member-of-the-Public Locations at SRS using CAP88-PC Version 4.0

The Environmental Protection Agency (EPA) requires the use of the computer model CAP88-PC to estimate the total effective doses (TED) for demonstrating compliance with 40 CFR 61, Subpart H (EPA 2006), the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. As such, CAP88 Version 4.0 was used to calculate the receptor dose due to routine atmospheric releases at the Savannah River Site (SRS). For estimation, NESHAP dose-release factors (DRFs) have been supplied to Environmental Compliance and Area Closure Projects (EC&ACP) for many years. DRFs represent the dose to a maximum receptor exposed to 1 Ci of a specified radionuclide being released into the atmosphere. They are periodically updated to include changes in the CAP88 version, input parameter values, site meteorology, and location of the maximally exposed individual (MEI). In this report, the DRFs were calculated for potential radionuclide atmospheric releases from 13 SRS release points. The three potential onsite MEI locations to be evaluated are B-Area, Three Rivers Landfill (TRL), and Savannah River Ecology Lab Conference Center (SRELCC) with TRL’s onsite workers considered as members-of-the-public, and the potential future constructions of dormitories at SRELCC and Barracks at B-Area. Each MEI location was evaluated at a specified compass sector with different area to receptor distances and was conducted for both ground-level and elevated release points. The analysis makes use of area-specific meteorological data (Viner 2014). The resulting DRFs are compared to the 2014 NESHAP offsite MEI DRFs for three operational areas; A-Area, H-Area, and COS for a release rate of 1 Ci of tritium oxide at 0 ft. elevation. CAP88 was executed again using the 2016 NESHAP MEI release rates for 0 and 61 m stack heights to determine the radionuclide dose at TRL from the center-of-site (COS).

54 ENVIRONMENTAL SCIENCES↗

A Picture Speaks 360,000 Words - Virtual Reality as a Decommissioning Planning Tool - 19364

Whiteshell Laboratories, located in Manitoba, Canada, provided research facilities for the Canadian nuclear industry since the early 1960's. Decommissioning of Whiteshell Laboratories has been ongoing since 2002 under Atomic Energy of Canada (AECL) and, more currently, since 2015 under the WL Closure Project managed by Canadian Nuclear Laboratories (CNL). One of the key steps to ensuring safe decommissioning operations is effective planning, including pre-job briefings, and post-job verification and review. Effective planning involves clear and concise communication of the field conditions, system configurations, hazards, and task goals or achievements to front line employees, and task approvers and verifiers. In many instances, employees can enter, view, inspect, verify or otherwise familiarize themselves with the task and task location. However, in several cases, hazardous conditions in the task location make it difficult for employees to easily access the location themselves, due to hazardous conditions, PPE requirements, training qualification gaps or space limitations. Since 2016, 360 deg. cameras have been used to create a virtual 'tour' of the hazardous task locations at Whiteshell Laboratories, which can be viewed by one or all of the employees involved in a task, from a position of safety. This allows a task to be discussed with all employees involved without the need for added risk of exposure to dose or industrial hazards or costly PPE, and supports ALARA control techniques of removing the hazard by moving work planning walk downs away from hazardous locations and guarding the worker by limiting the time a worker is exposed to the hazard. This paper provides an overview of the technologies used to capture and present the 360 virtual tours, the benefits from a safety, schedule and cost perspective, and the limitations of the current implementation that could be improved upon in a future iteration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling completion of the material disposition area G closure at the Los Alamos National Laboratory

Los Alamos National Security, LLC (LANS) and the Los Alamos Site Office (LASO) have developed and are implementing an integrated strategy to accelerate the disposition of Los Alamos National Laboratory (LANL) legacy transuranic waste inventory currently stored in Technical Area 54, Material Disposition Area (MDA) G. As that strategy has been implemented the easier waste streams have been certified and shipped leaving the harder more challenging wastes to be dispositioned. Lessons learned from around the complex and a partnership with the National Transuranic Program located in Carlsbad, New Mexico, are enabling this acceleration. The Waste Disposition Program is responsible for the removal of both the above ground and below grade, retrievably stored transuranic waste in time to support the negotiated consent order with the State of New Mexico which requires closure of MDA G by the year 2015. The solutions and strategy employed at LANL are applicable to any organization that is currently managing legacy transuranic waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Robotic Equipment for Retrieval of High Level Waste to Support Environmental Closure - 18162

The Idaho Cleanup Project contractor, Fluor Idaho, LLC, is responsible for managing HLW calcine stored in the Calcined Solids Storage Facility at the Idaho Nuclear Technology and Engineering Center. The Idaho Nuclear Technology and Engineering Center is a DOE managed facility located at the INL Site in the remote portions of southeast Idaho. In 2016, DOE directed Fluor Idaho to develop and test a full-scale retrieval system to demonstrate the ability to safely retrieve HLW calcine from the Calcined Solids Storage Facility for future retrieval and processing. Removing HLW calcine from the State of Idaho is required by the 1995 Settlement Agreement, which mandates that DOE have HLW calcine ready to be moved out of Idaho by December 2035. Fluor Idaho is currently testing retrieval and transfer concepts to ensure that the Calcined Solids Storage Facility is placed in a final configuration that is protective of human health and the environment after HLW calcine has been removed to the maximum extent practical. This paper describes the full-scale prototype that will be used to prove retrieval and transfer system design capabilities, verify operating parameters, and establish a basis for calcine retrieval efficacy. Additionally, it describes the retrieval (bulk and residual) and visual monitoring systems that were designed and tested in 2017 and will continue to be tested with the full-scale prototype. Testing (i.e., full-scale mockup, bulk retrieval, residual clean-out, and visualization monitoring) performed by Fluor Idaho will demonstrate the maximum extent practical of HLW calcine removal that is achievable. This is critical to (1) establish criteria for ending calcine removal activities, (2) evaluate cost and benefits associated with performing additional removal, and (3) ensure clean up and closure standards under applicable requirements (e.g., statutes, orders, and agreements) are met. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for the Project Shoal Area: Subsurface Corrective Action Unit 447 Shoal,Nevada, Site

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) has prepared this Closure Report for subsurface Corrective Action Unit (CAU) 447 at the Shoal, Nevada, Site, which was formerly called the Project Shoal Area. The Shoal site was the location of an underground nuclear test in 1963 that resulted in residual radionuclide contamination at the detonation depth of 1211 feet (ft) (DOE 2015a). The environmental restoration process and Corrective Action strategy are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO) (FFACO 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) statues and regulations. Responsibility for the environmental site restoration was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The Shoal site is south of U.S. Highway 50, approximately 30 miles southeast of Fallon, in Churchill County, Nevada (Figure 1). The site was selected for underground nuclear testing in 1961, as part of the Vela Uniform Program. Vela was a research and development program directed toward locating, detecting, and identifying underground and high-altitude nuclear detonations. The Vela Uniform program was specific to underground detonations (AEC 1964). The objective of Project Shoal was to detonate a nuclear device underground in an active seismic area to improve the United States’ ability to detect, identify, and locate underground nuclear detonations. The underground nuclear test at Shoal was a joint effort between the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC), which was the predecessor agency to DOE. Figure 1 is a map showing the site location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aerodynamic Performance and Flow-Field Characteristics of Two Waverider-Derived Hypersonic Cruise Configurations

The component integration of a class of hypersonic high-lift configurations known as waveriders into hypersonic cruise vehicles was evaluated. A wind-tunnel model was developed which integrates realistic vehicle components with two waverider shapes, referred to as the straight-wing and cranked-wing shapes. Both shapes were conical-flow-derived waveriders for a design Mach number of 4.0. Experimental data and limited computational fluid dynamics (CFD) predictions were obtained over a Mach number range of 1.6 to 4.63 at a Reynolds number of 2.0 x 10(exp 6) per foot. The CFD predictions and flow visualization data confirmed the shock attachment characteristics of the baseline waverider shapes and illustrated the waverider flow-field properties. Experimental data showed that no significant performance degradations, in terms of maximum lift-to-drag ratios, occur at off-design Mach numbers for the waverider shapes and the integrated configurations. A comparison of the fully-integrated waverider vehicles to the baseline shapes showed that the performance was significantly degraded when all of the components were added to the waveriders, with the most significant degradation resulting from aftbody closure and the addition of control surfaces. Both fully-integrated configurations were longitudinally unstable over the Mach number range studied with the selected center of gravity location and for unpowered conditions. The cranked-wing configuration provided better lateral-directional stability characteristics than the straight-wing configuration.

Cockrell, Charles E., Jr.↗

Investigation of an inhomogeneous turbulent mixing model for conditional moment closure applied to autoignition

The present paper examines the case of autoignition of high pressure methane jets in a shock tube over a range of pre-heated air temperatures in engine-relevant conditions. The two objectives of the present paper are: (i) to examine the effect of the inhomogeneous mixing model on the autoignition predictions relative to the results obtained using homogeneous mixing models and (ii) to see if the magnitude of the change can explain the discrepancy between the predictions of ignition delay previously obtained with homogeneous mixing models and the experimental data. The governing equation of the scalar dissipation rate is solved for transient conditions and two different formulations of the same model are tested and compared: one using the linear model for the conditional velocity and one including the gradient diffusion model. The predicted ignition kernel location and time delay over a range of pre-combustion air temperatures are compared with results obtained using two homogeneous turbulent mixing models and available experimental data. The profiles of conditional velocity and the conditional scalar dissipation rate are examined. Issues related to the conditional velocity model are discussed. It is found that the differences in the predictions are due to the mixing model only. The inhomogeneous model using the gradient conditional velocity model produces much larger ignition delays compared to the other models, whereas the inhomogeneous form including the linear model does not produce any significant differences. The effect of the turbulent inhomogeneous model is larger at high air temperatures and decreases with decreasing air temperatures. In comparison with the measured ignition delays, the inhomogeneous-Gradient model brings a small improvement at high air temperatures over the results from the turbulent homogeneous models. At low air temperatures, other parameters need to be investigated in order to bring the predicted ignition delays and locations within the experimental data scatter. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗