Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Improved measurement of the half-life of the J π = 8 - nuclear isomer 152m 2 Eu

The standard γ-ray energy calibration source 152 Eu is well known based on the 13.5 y decay of its ground state. Nevertheless, in addition to this decay 152 Eu also has two relatively long-lived isomeric states: a 9 h J π =0 - state at E * =46 keV and a 96 min J π =8 - state at E * =148 keV. In this work, we report a new measurement of the half-lives of both of these isomeric states. Excited states in 152 Eu were populated following the 154 Sm (p,3n) reaction using a 25 MeV proton beam from the K-150 cyclotron at the Cyclotron Institute of Texas A&M University. Post irradiation, γ rays from the de-excitation of the long lived isomeric states were measured using the six BGO shielded high-purity germanium (HPGe) clover detectors that are part of the STARLiTeR array. The half-life of the J π =8 - isomer 152m 2 Eu was obtained by measuring the decrease in intensity of the 90 keV γ ray from the cascade to the ground state. The half-life of this state was measured to be 95.8(4) min which is in agreement with and significantly more precise than the previously measured value of 96(1) min. In a manner similar to the ground state the second long-lived isomer 151m 1 Eu, the J π =0 - state at 46 keV, β decays to excited states in 152 Gd and 152 Sm. Also, the half-life of this state was measured to be 9.39(7) h using five γ-ray transitions.

36 MATERIALS SCIENCE↗

Neutron rich matter in the laboratory and in the heavens after GW170817

The historic observations of the neutron star merger GW170817 advanced our understanding of r-process nucleosynthesis and the equation of state (EOS) of neutron rich matter. Simple neutrino physics suggests that supernovae are not the site of the main r-process. Instead, the very red color of the kilonova associated with GW170817 shows that neutron star (NS) mergers are an important r-process site. We now need to measure the masses and beta decay half-lives of very neutron rich heavy nuclei so that we can more accurately predict the abundances of heavy elements that are produced. This can be done with new radioactive beam accelerators such as the Facility for Rare Isotope Beams (FRIB). GW170817 provided information on the deformability of NS and the equation of state of dense matter. The PREX II experiment will measure the neutron skin of {sup 208}Pb and help constrain the low density EOS. As the sensitivity of gravitational wave detectors improve, we expect to observe many more events. We look forward to exciting advances and surprises!.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-nanosecond Half-life Measurement of the Yrast I{sup π}=5{sup −} State in the N=78 Nucleus {sup 136}{sub 58}Ce using Fast-timing Coincident Gamma-ray Spectroscopy

We report on the measurement of the half-life of the yrast I{sup π}=5{sup −} state in the transitional nucleus {sup 136}Ce using a combined HPGe-LaBr3(Ce) scintillator gamma-ray detection array. The measured value for the E1 decay is approximately half a nanosecond, which corresponds to an E1 decay strength of approximately 2×10{sup −6} Wu. This value is in line with single-particle type E1 decays in this mass region and suggests no sign of additional K-hindrance associated with axially symmetric quadrupole deformations observed for lighter cerium isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The aluminium-26 distribution in a cosmological simulation of a Milky Way-type Galaxy

Context . The 1.8 MeV γ -rays corresponding to the decay of the radioactive isotope 26 Al (with a half-life of 0.72 Myr ) have been observed by the SPI detector on the INTEGRAL spacecraft and extensively used as a tracer of star formation and current nucleosynthetic activity in the Milky Way Galaxy. Further information is encoded in the observation related to the higher 26 Al content found in regions of the Galaxy with the highest line-of-sight (LoS) velocity relative to an observer located in the Solar System. However, this feature remains unexplained. Aims . We ran a cosmological “zoom-in” chemodynamical simulation of a Milky Way-type galaxy, including the production and decays of radioactive nuclei in a fully self-consistent way. We then analyzed the results to follow the evolution of 26 Al throughout the lifetime of the simulated galaxy to provide a new method for interpreting the 26 Al observations. Methods . We included the massive star sources of 26 Al in the Galaxy and its radioactive decay into a state-of-the-art galactic chemical evolution model, coupled with cosmological growth and hydrodynamics. This approach allowed us to follow the spatial and temporal evolution of the 26 Al content in the simulated galaxy. Results . Our results are in agreement with the observations with respect to the fact that gas particles in the simulation with relatively higher 26 Al content also have the highest LoS velocities. On the other hand, gas particles with relatively lower 26 Al content (i.e., not bright enough to be observed) generally display the lowest LoS velocities. However, this result is not conclusive because the overall rotational velocity of our simulated galaxy is higher than that observed for cold CO gas in the Milky Way Galaxy. Furthermore, we found no significant correlation between gas temperature, rotational velocity, and 26 Al content at any given radius. We also found the presence of transient 26 Al-rich spots at low LoS velocities and we show that one such spot had been captured by the INTEGRAL/SPI data. Based on our model, we present a prediction for the detection of 1.8 MeV γ -rays by the future COSI mission. We find that according to our model, the new instrument will be able to observe similar 26 Al-emission patterns to those seen by INTEGRAL/SPI.

Wehmeyer, B. (ORCID:0009000254149292)↗

Geant4 Monte-Carlo (GEMC) A database-driven simulation program

GEMC[1] is an application that harnesses the power of databases to execute Geant4 Monte-Carlo simulations. The databases (MYSQL, CSQL, TEXT) define the geometry, materials, digitization algorithms, readout electronics and output formats. Implemented in C++, GEMC also boasts a user-friendly Python API that facilitates detector construction and database population. GEMC can handle real-life scenarios such as geometry variations and the run number-dependent calibration constants and digitization parameters. This abstract provides an overview of GEMC, accompanied by examples that showcase its versatility. We delve into the practical application of GEMC within the the CLAS12 experimental program at Jefferson Lab.

Ungaro, Maurizio↗

Recent searches for double-electron capture of nuclei to excited states

Double electron capture has been of interest of many theoretical and experimental works as a possible extension of double beta-decay investigations. The neutrinoless double-electron capture, similarly as the neutrinoless double beta-decay may help to clarify if neutrinos are Majorana or Dirac particles. Results obtained in several double electron capture experiments are reviewed and new experiments to be carried out in deep underground laboratories using enriched sources and multidimensional HPGe-HPGe gamma-ray spectrometry with a few years of counting time are proposed, which should be able to improve half-lives limits by at least an order of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feasibility of creating a specialized reactimeter based on the inverse solution to kinetics equation with a current-mode neutron detector

The file-evaluation results of a reactimeter based on the inverse solution to the kinetics equation (ISKE) are presented, which were obtained using an operating hardware-measuring complex with a KNK-4 neutron detector working in the current mode. The processing of power-recording files of the BR-1M, BR-K1, and VIR-2M reactors of the Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, which was performed with the use of Excel simulation of the ISKE formalism, demonstrated the feasibility of implementation of the reactivity monitoring (during the operation of these reactors at stationary power) beginning from the level of ~5 × 10{sup –4}β{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A high voltage power converter for space astronomy applications

A dc-dc low-power, high-voltage converter for use in space is described which furnishes a commandable, low-noise dc output in the range of 0 to -7500 V. The converter is suitable for biasing of detectors commonly employed in space astronomy, microchannel plates, photomultipliers, and gas discharge detectors. The converter's reliability has been demonstrated by accelerated life testing under thermal vacuum. The electrical and mechanical design, packaging, layout and fabrication techniques, and tests employed are described.

Ray, David C.↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Design and Flight Testing of an Inflatable Sunshield for the NGST

The Next Generation Space Telescope (NGST) mission is scheduled to launch in 2007 and be stationed at L2 for a mission life of ten years. The large aperture mirror and optical detectors aboard NGST require shielding from the constant solar energy seen at this orbit. The government reference NGST design, called the Yardstick, baselined a sunshield using an inflation deployment system. During the formulation phase, NGST is spending approximately 25% of the overall budget to foster the development of new technology. The goal is to develop and demonstrate enabling or enhancing technology and provide innovative solutions for the design of the NGST observatory. Inflatable technology falls in the category of enhancing technology due to its advantages in weight, stowed volume and cost. The Inflatable Sunshield in Space (ISIS) flight experiment will provide a realistic space flight demonstration of an inflatable sunshield. The supporting technology development program will provide an information base for the design, manufacture, assembly and testing of large thin membranes and inflatable structural elements for space structures. The ISIS experiment will demonstrate the feasibility of using inflatable technology to passively cool optical systems for NGST and provide correlation between analytical predictions and on orbit results. The experiment will be performed on a Hitchhiker/Space Shuttle mission in late 2001. The ISIS mission is an effort to address several major technical challenges of the NGST inflatable sunshield, namely controlled inflation deployment, plenarity and separation of large stretched membranes, space rigidization of inflatable booms, and dynamic modeling and simulation. This paper will describe the design of the flight experiment and the testing to be performed on-orbit.

Adams, Michael L.↗

Optical Detection of Organic Chemical Biosignatures at Hydrothermal Vents

We have developed a non-contact, optical life detection instrument that can detect organic chemical biosignatures in a number of different environments, including dry land, shallow aqueous, deep marine or in ice. Hence, the instrument is appropriate as a biosignature survey tool both for Mars exploration or in situ experiments in an ice-covered ocean such as one might wish to explore on Europa. Here, we report the results we obtained on an expedition aboard the Russian oceanographic vessel Akademik Mstislav Keldysh to hydrothermal vent sites in the Pacific Ocean using our life detection instrument MCDUVE, a multichannel, deep ultraviolet excitation fluorescence detector. MCDUVE detected organic material distribution on rocks near the vent, as well as direct detection of organisms, both microbial and microscopic. We also were able to detect organic material issuing directly from vent chimneys, measure the organic signature of the water column as we ascended, and passively observe the emission of light directly from some vents.

Conrad, P. G.↗

Lipid Decontamination Procedures for Life Detection Missions

Molecular biosignatures are key targets for current, proposed, and future life detection missions. With the high accuracy and low limit of detection (LOD) that new and future instruments will require, decontamination of life detection hardware is necessary to prevent false positives. Lipids are a molecular biosignature of interest, as they are ubiquitous to all life as we know it, can survive unaltered in the geologic record for longer than any other biomolecule (i.e. billions of years), and form through both biotic and abiotic processes. Lipids display origin-diagnostic molecular patterns that can reveal biotic or abiotic synthesis, so finding them and ascertaining their molecular features is important for potentially detecting evidence of life elsewhere. Traditional methods of decontamination, or contamination control (CC), primarily clean hardware through fabrication in sterile (cleanroom) environments, killing microbes, and removing/flushing contaminants off instrument and spacecraft components. However, research suggests that some standard cleaning methods are either unlikely to remove lipid contaminants or are incompatible with life detection instrument materials. To solve this problem, I propose to find, test, and verify a decontamination method that thoroughly cleans instruments by destroying lipid molecules, but is simultaneously compatible with major materials used in these instruments. I will study the effects of traditional CC methods (including Dry Heat Microbial Reduction and Vapor phase Hydrogen Peroxide) and experimental CC methods (Electron Beam Irradiation) on lipid molecules for application to life detection instrumentation. I will then develop a CC plan for a novel lipid detector (ExCALiBR, Extractor for Chemical Analysis of Lipid Biomarkers in Regolith) searching for lipids in either soil or icy world scenarios. This plan will uphold planetary protection regulation requirements and validate experimental analyses of in-situ life detection tests.

Decontamination↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evolution of the Data Quality Monitoring and Prompt Processing System in the proto DUNE-SP experiment

The DUNE Collaboration currently operates an experimental program based at CERN which includes a beam test and an extended cosmic ray run of two large-scale prototypes of the massive Liquid Argon Time Projection Chamber (LArTPC) for the DUNE Far Detector. The volume of data collected by the single-phase prototype (protoDUNE-SP) amounts to 3PB and the sustained rate of data sent to mass storage is O(100) MB/s. Data Quality Monitoring was implemented by directing a fraction of the data stream to the protoDUNE prompt processing system (p3s) which is optimized for continuous low-latency calculation of the vital detector metrics and various graphics including event displays. It served a crucial role throughout the life cycle of the experiment. We present our experience in leveraging the CERN computing environment and operating the system over an extended period of time, while adapting to evolving requirements and computing platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of pixel-cell detector technology for Advanced Neutron Beam Monitors

Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors with a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.

36 MATERIALS SCIENCE↗