MARSAME Radiological Release Report for Metal Items from TA 53, Set 18

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-036 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 19

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-036 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 28

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item in Attachment 1). Process knowledge indicates that items were released from radiological areas, including radiation areas, prior to the implementation of the 2000 metals moratorium. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in depth showed no identifiable gamma radiation from beam activation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Background simulations for DANCE, FP-14 considering the Mark IV spallation target

With the installation of the Mark-IV target at LANSCE in 2022 significant changes of the beam-related backgrounds at DANCE are observed. DANCE is located at flight path 14 (FP-14) in the experimental area 2 (ER-2) at LANSCE. This new background is so severe that the array is not operational for several microseconds after the protons hit the spallation target (Figures 1 - 3).

43 PARTICLE ACCELERATORS↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 22

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever bein direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

36 MATERIALS SCIENCE↗

LAMP Emittance Budget Rev. 2

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

LAMP Operational Concepts

This brief report describes the major operational changes resulting from accelerator design and implementation of the LAMP scope. Improvements in operational performance are discussed, along with implications for integration with the existing LANSCE accelerator complex. Potential impacts to the present LANSCE operational modes and integration with the existing personnel and machine protection systems are also discussed.

43 PARTICLE ACCELERATORS↗

Beamline Device Designators

LAMP is to replace the front-end of LANSCE. Therefore, the device designators for LAMP needs approval from LANSCE. This document defines the agreed upon device designator names to be used in LAMP and in the prototype beamline LAMP in ADEF Tunnel (LAT).

43 PARTICLE ACCELERATORS↗

On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.

47 OTHER INSTRUMENTATION↗

Micronuclei Induction in Human Fibroblasts Exposed In Vitro to Los Alamos High-Energy Neutrons

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility#s ICE House 30L beamline is known to generate neutrons that simulate the secondary neutron spectra of earth#s atmosphere. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and International Space Station (ISS). To evaluate the biological damage, we exposed human fibroblasts in vitro to the LANSCE neutron beams without degrader at an entrance dose rate of 25 mGy/hr and analyzed the micronuclei (MN) induction. The cells were also placed behind a 9.9 cm water column to study effect of shielding in the protection of neutron induced damages. It was found that the dose response in the MN frequency was linear for the samples with and without shielding and the slope of the MN yield behind the shielding was reduced by a factor of 3.5. Compared to the MN induction in human fibroblasts exposed to a gamma source at a low dose rate, the RBE was found to be 16.7 and 10.0 for the neutrons without and with 9.9 cm water shielding, respectively.

Gersey, Brad↗

M-BAND Analysis of Chromosome Aberration In Human Epithelial Cells exposed to Gamma-ray and Secondary Neutrons of Low Dose Rate

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.

Hada, M.↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Six-dimensional matching of intense beam with linear accelerating structure

Beam matching is a common technique that is routinely employed in accelerator design with the aim of minimizing beam losses and preservation of beam brightness. Despite being widely used, a full theoretical understanding of beam matching in 6D remains elusive. In this work, we present an analytical treatment of 6D beam matching of a high-intensity beam onto an RF structure. We begin our analysis within the framework of a linear model, and apply the averaging method to a set of 3D beam envelope equations. Accordingly, we obtain a matched solution that is comprised of smoothed envelopes and periodic terms, describing envelope oscillations with the period of the focusing structure. We then consider the nonlinear regime, where the beam size is comparable with the separatrix size. Stating with a Hamiltonian analysis in 6D phase space, we attain a self-consistent beam profile and show that it is significantly different from the commonly used ellipsoidal shape. Subsequently, we analyze the special case of an equilibrium with equal space charge depression between all degrees of freedom. Comparison of beam dynamics for equipartitioned, equal space charge depression, and equal emittances beams is given. Finally, we present experimental results on beam matching in the LANSCE linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture of UO 2 targets prepared by spin-coating assisted combustion synthesis

Two uranium dioxide (UO 2 ) targets of (414 ± 23) nm and (1092 ± 93) nm thicknesses were prepared on 6061 aluminum alloy and puratronic grade aluminum backing materials. The targets were deposited with a novel method combining spin coating and solution combustion synthesis (SCS). The target layers consisted of small (3–7 nm) UO 2 grains and uniformly distributed ultra-small (1–3 nm) pores. The prepared targets were tested at the Los Alamos National Laboratory’s LANSCE facility for neutron irradiation damage and suitability for neutron capture experiments. The samples showed no signs of target material loss after the irradiation. However, irradiation caused a significant increase in the grain size (4–10 nm), as well as upward mass diffusion and coalescence of the pores due to the thermal spikes. The magnesium in the aluminum 6061 alloy backing also diffused into the UO 2 layer during neutron irradiation. The structural changes in the target after the irradiation do not affect the data from neutron capture. As a result, the new method can be used more broadly to prepare other actinide targets for nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrospraying deposition and characterization of potassium chloride targets for nuclear science measurements

Natural and isotopically enriched KCl targets were prepared using specially formulated KCl solutions, deposited by electrospraying on thin (1.5 μm) gold backings, followed by a short annealing in a preheated (350-450 °C) furnace. Various techniques, such as X-ray fluorescence (XRF), scanning electron microscopy (SEM) imaging, and energy-dispersive X-ray spectroscopy (EDS), were used to characterize the produced targets. A white neutron beam at the Los Alamos Neutron Science Center (LANSCE) facility was also used to verify the estimated atomic percentages of the enriched 40 KCl targets. KCl was deposited relatively uniformly as large particles rather than films on the gold surface. As a result, this method can be broadly extended to make stable targets that are difficult to produce with other methods and more exotic radioactive targets required for research in fundamental sciences and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking fast-neutron response of 7 Li-enriched C 7 LYC scintillators: Simulations and experiment

New insights into the fast neutron response of 7 Li-enriched C 7 LYC scintillators have been obtained through detailed Geant4 simulations of 35 Cl(n,p) and 35 Cl(n, α) reactions that are primarily responsible for the fast neutron response of C 7 LYC. The light output of a 1” x1” C 7 LYC detector was simulated using the Birks equation for light quenching in scintillators. The simulations were benchmarked against neutron scattering data from a 12 C target obtained with a white neutron beam at the Los Alamos LANSCE facility and fourteen 1”x1” C 7 LYC detectors. Incident neutron energies extracted from time-of-flight measurements, and appropriate recoil corrections for the different detector angles were used to map the response of C 7 LYC to mono-energetic neutrons. Resonances in the 35 Cl(n,p) reaction cross-section below 3 MeV incident neutron energy were directly observed in C 7 LYC. The experimental data and simulations are compared with ENDF databases, as well as recent direct cross-section measurements of neutrons scattered from a 35 Cl target. In conclusion, the results suggest a scrutiny of the 35 Cl(n,p) and 35 Cl(n, α) cross sections at low energy in the ENDF library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.