SEARCH · Engineering Papers
Results for “Krypton”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Summary of FY-11 Krypton Capture Activities at the Idaho National Laboratory
Dissolution and voloxidation steps performed in the nuclear fuel reprocessing cycle result in the production of radioactive fission products in their respective off-gas streams. Various isotopes of Kr and Xe are included in the composition of the off-gas radioactive constituents. Depending on the fuel cooling times, Kr-85, with a half-life of 10.7 years may need to be captured per EPA regulations for radioactive emissions. This report includes the results of the ongoing investigations into the solid phase adsorption of Kr, specifically using thermal swing operation, as part of the Off-Gas Sigma Team effort. Experimental results produced from sorbent capacity evaluations have been included. Additionally, Kr adsorption isotherms were produced at two test temperatures to assist with modeling efforts. A final task was to define a strategy for legacy samples obtained from historical Kr immobilization experiments performed in the late ‘70’s at the INL. The results reported herein will be included in a compiled final report describing the work completed by the Off-Gas Sigma team members in FY-11.
Cost-Benefit Assessment of Krypton and Xenon Recovery from Aqueous Reprocessing
The purpose of this paper is to provide an understanding of the cost-benefit of capturing Kr and Xe from the existing process of aqueous reprocessing of UNF. The study accomplishes this with a market assessment of Xe prices and volumes today, coupled with a cost estimate of Kr and Xe capture out of cryogenic distillation within aqueous reprocessing. The market assessment shows that the average price of Xe is about $\$ $60/L while the average price of Kr is about $\$ $1/L. The assessment also shows that the market structure for Xe is one of oligopoly, in other words, very few suppliers to the Xe market. The assessment shows growing demand for Xe, particularly in medical applications like anesthesia. The cost assessment finds the unit cost of Xe to range from $\$ $71.50/L to $\$ $131.13/L. This range is only slightly above the current range of market prices today, and with growing demand for Xe, prices could reach the range it would take to support extraction of Xe from aqueous reprocessing. On the other hand, the estimated cost range for Kr is $\$ $830.15/L up to $\$ $1,522.52/L, which far exceeds the range of market prices for Kr. However, as the text notes, Kr capture is already part of aqueous reprocessing so these costs are sunk costs (already incurred) whereas the cost estimates for Xe are marginal cost (if Xe is desired, then the cost estimate would result from the Xe capture).
Krypton-85 chronometry of spent nuclear fuel
We describe the use of the radionuclide 85 Kr, which is produced by nuclear fission and has a half-life of 10.76 years, to determine the age of spent nuclear fuel. The method is based on mass-spectrometric measurement of the relative abundance of fissiogenic Kr isotopes extracted from a fuel sample, and we show that it can be applied to micron-scale particles of spent fuel that are analogous to particles that have been released into the environment from various nuclear facilities in the past. 85 Kr chronometry is potentially valuable for identifying and attributing nuclear materials, grouping samples into collections of common origin that can be used to reconstruct the origin and irradiation history of the material, and verifying declared nuclear activities in the context of international monitoring programs.
Excitation cross section for some of the doubly ionized states of argon, neon, and krypton by fast electrons.
Excitation cross section for double ionized states of Ar, Ne and Kr due to fast electron impingement on neutral atom
Transport coefficients of partially ionized krypton and xenon.
Partially ionized Kr and Xe transport coefficients for various pressures and at high temperatures computed on basis of charged particle cross sections
Experimental investigation of momentum exchange between argon and krypton beams incident on clean gold surfaces
Electromagnetic torsion balance measurement of forces exerted on clean Au surfaces by monoenergetic steady state Ar and Kr beams, calculating thermal accommodation coefficients
Multistate impact-parameter calculation of atom-atom excitation cross sections - Excitation of atomic hydrogen by neon, argon, and krypton
Hydrogen and inert gas atoms collisional excitation cross sections calculated by multistate impact parameter approximation
Gas chromatographic determination of hydrogen, nitrogen, oxygen, methane, krypton, and carbon dioxide at room temperature
Hydrogen, N, O, Kr methane and carbon dioxide gas chromatographic examination, discussing life detection device for Mars landing
Born wave cross section calculations for the excitation of He/1 super 1 S/ to He/N super 1 L/ by helium, neon, argon and krypton
He excitation by He, Ne, Ar and Kr collisions, calculating first Born wave cross section
New CW ion laser transitions in argon, krypton, and xenon
CW ion laser transitions in Ar, Kr and Xe, tabulating threshold data
Isotopic composition of xenon and krypton in the lunar soil and in the solar wind
Xe and Kr isotopes gas extraction and mass spectrometer analyses of Apollo 11 lunar soil, Murray carbonaceous chondrite and atmospheric Xe
Shock tube investigation of bromine dissociation rates in the presence of helium, neon, argon, krypton, and xenon
Bromine dissociation rates in presence of He, Ne, Ar, Kr and Xe, determining rate constant expressions from light absorption measurements behind incident shock waves
Relative transition probabilities for krypton.
First experimental line strength data for the visible Kr II lines and for several of the more prominent Kr I lines are given. The spectroscopic light source used is the thermal plasma behind the reflected shock wave in a gas-driven shock tube. A 3/4-m spectrograph and a 1-m spectrograph were employed simultaneously to provide redundant photometry. The data are compared with other measurements and with theoretical calculations.
Krypton and xenon in lunar fines
Data from grain-size separates, stepwise-heated fractions, and bulk analyses of 20 samples of fines and breccias from five lunar sites are used to define three-isotope and ordinate intercept correlations in an attempt to resolve the lunar heavy rare gas system in a statistically valid approach. Tables of concentrations and isotope compositions are given.
Krypton and xenon in some lunar samples and the age of North Ray Crater
Explore the source record for details and available documents.
Role of autoionization in the near-threshold photoionization of argon and krypton metastable atoms
Explore the source record for details and available documents.