Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Real-Time ANPC Inverter Digital Twin with Integrated Design-For-Trust

The demand for renewable energy has increased over the last few years, and so has the demand for greater expectations within the energy market. This increasing trend has been accompanied by more significant usage of internet-connected devices (IoT), leading to critical electrical infrastructure being connected to the internet. Implementing internet connectivity with such devices and systems provides benefits such as improving the system's performance, facilitating irregularity and anomaly mitigation, and providing additional situational awareness for enhanced decision-making. However, enhancing the connected system with IoT introduces a drawback – a greater vulnerability to cyber-attacks. Cyber-attacks targeting critical infrastructure in the electrical sector have occurred in the United States and Ukraine. These cyber-attacks highlight and expose vulnerabilities that a system inherits when connecting to the internet. These attacks left thousands of customers without electricity for hours until operators could regain control of the electric utility grid. Therefore, to address the vulnerabilities of an internet-connected power electronic device, this work focused on the hardware layer of the system. Implementing a cyber-control system inside the hardware layer can significantly reduce the possibility of an attacker patching malicious controller firmware into a photovoltaic grid-connected inverter, thus mitigating the likelihood that the inverter becomes inactive a cyber-attack scenario. With this mitigation technique, if a cyberattack is successful and an attacker gains control of the network, a cyber-defense technique is in place to mitigate the impact of the cyber-attack. This additional protection layer was developed based on an innovative concept known as Digital Twin (DT). A DT, in this case, replicates an Active-Neutral Point Clamped (ANPC) inverter and was designed using a hardware language known as VHDL (Very High-Speed Integrated Circuit Hardware Description Language) and applied to Field-Programmable-GateArray (FPGA). The DT is embedded within the FPGA and contained in a controller board, the UCB (Unified Controller Board), developed by the University of Arkansas electrical engineering team. This UCB also contains two Digital Signal Processors (DSPs) responsible for generating associated signals to control an authentic physical inverter. These DSP signals are received and processed by the FPGA that implements the DT of an ANPC; in other words, it simulates in realtime the expected output of an actual ANPC inverter using the signals from the DSP. When a new firmware is ready to be patched, the DT provides output signals simulating behavior that a real ANPC inverter would generate with the new firmware. The new firmware is tested to check if it meets all the operational requirements established using a Design-For-Trust technique (DFTr). If the new firmware fails in at least one of the DFT tests, it is considered malicious and must be rejected. This work is divided into sections, such as Background, which explains the pieces that were used and the strategy behind this work; Process and Procedure, which explains the methodology that was adopted to prove the reliability and effectiveness of this work; Results and Discussion, where the simulations and results are described and explained; followed by Conclusion and Future work section, which concludes this work and adds possible future projects to continue this work further.

do Amaral Custodio, Paulo Vitor↗

Microgrid Black Start Challenges: The Role of Grid-Forming Inverters

Grid-forming (GFM) inverters are becoming increasingly important for future power systems, particularly in establishing and restarting microgrids after blackouts. The use of GFM inverters enables microgrids to operate independently of utility power and provide key advantages over synchronous generators in black start scenarios, including rapid startup and stable voltage and frequency support for critical loads. However, inverter-driven black start introduces unique challenges and operational considerations. This article examines key challenges and solutions, emphasizing inverter design, control strategies, and microgrid system requirements. Drawing on analysis, simulation, and experimental results, this article highlights the central role of GFM inverters in ensuring reliable and resilient microgrid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating Multi-Microgrid Black Start Methods Using Grid-Forming Inverters

This paper examines state-of-the-art microgrid (MG) black-start technologies with grid-forming (GFM) inverter-based resources (IBRs) and proposes black start and interconnection methods for 100% inverter-based MGs. A multiple-MG approach is proposed and compared to the existing methods in a 4-bus, 12-GFM inverter simulation test setup. This investigation involves intelligent synchronization units that enable the autonomous synchronization of multiple MGs based on their terminal measurements. MGs in this setup are held at different loading levels and comprise averaged models of GFM inverters. The results of the black-start techniques are compared, and conclusions are drawn to better prepare MG planners and distribution system operators for next-generation, multi-MG, GFM inverter-based, black-start procedures.

black start↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Evaluation of the DC bus link capacitors and power transistor modules in the qualification testing of PV inverters

To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.

14 SOLAR ENERGY↗

Efficient and reversible electron bifurcation with either normal or inverted potentials at the bifurcating cofactor

A longstanding mystery surrounding electron bifurcation is the significance of inverted (or “crossed”) reduction potentials of the two-electron bifurcating cofactor. Using a many-electron open-system kinetic model, we show that reversible and efficient electron bifurcation is possible without inverted reduction potentials at the bifurcating site if the absolute value of the difference between first and second reduction potentials of the bifurcating species is sufficiently large (on the scale of the redox-potential span of the high- and low-potential branches). Surprisingly, the case with strong, normally ordered potentials at the bifurcating cofactor can produce electron bifurcation that is just as effective as the case with strongly inverted potentials. Lastly, this finding amplifies the puzzle surrounding the recruitment of inverted potentials in the few well-characterized bifurcating systems of nature and suggests that electron bifurcating cofactors without strongly inverted potentials may yet be discovered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Small-Signal Stability Impacts of Load and Network Dynamics on Grid-Forming Inverters

This paper presents several stability analyses for grid-forming inverters and synchronous generators considering the dynamics of transmission lines and different load models. Load models are usually of secondary importance compared to generation source models, but as the results show, they play a crucial role in stability studies with the introduction of inverter-based resources. Given inverter control time scales, the implications of considering or neglecting electromagnetic transients of the network are very relevant in the stability assessments. In this paper, we perform eigenvalue analyses for inverter-based resources and synchronous machines connected to a load and explore the effects of multiples models under different network representations. We explore maximum loadability of inverter-based resources and synchronous machines, while analyzing the effects of load and network dynamic models on small-signal stability. The results show that the network representation plays a fundamental role in the stability of the system of different load models. The resulting stability regions are significantly different depending on the source and load model considered.

grid forming inverters↗

A Compact 50kW High Power Density, Hybrid 3-Level Paralleled T-type Inverter for More Electric Aircraft Applications

The demand for high performing, lightweight, reliable inverters, increased the scope of wide bandgap and high-switching frequency based solutions. To achieve such high efficiency inverters, it is vital to focus on the system level design considerations to maximize the benefits of these advanced technologies. This paper presents an improved design based on considerations to further reap the benefits of choosing the right inverter topology; increased capabilities through paralleling devices, with reduced total number of switches; and designing a planarized inverter with PCB based busbar. Appropriate thermal analysis and heatsink design has aided in increased system power density along with the overall efficiency. Demonstration of a 50kW 3-phase 3-level paralleled T-type SiC inverter operating at 40kHz switching frequency for aircraft applications is shown to evaluate the benefits of proposed design methodology. Here, the prototype achieves a high power density of 11kW/L.

42 ENGINEERING↗

Self-Protective Inverters Against Malicious Setpoints Using Analytical Reference Models

This paper presents the concept of self-protective inverters using reference models. In the proposed method, incoming setpoints from the utility operator or third-party aggregators are inspected using analytical reference models before engaging the setpoints to the inverter’s local controller. When a malicious setpoint passes the existing security layers, a smart inverter can examine the integrity of an incoming setpoint in real-time. The efficacy of the developed method has been tested using a laboratory setup, including a three-phase 3kVA SiC-MOSFET inverter and a 12kW NHR 9410 regenerative grid emulator. Furthermore, the results verify that the developed analytical models can provide device-level protection for grid-interactive inverters by inspecting and preventing harmful setpoints from getting engaged to the local controller.

42 ENGINEERING↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Impact of Inverter Dead-Time in Single-Phase Wireless Power Transfer Systems

In this paper, the effect of the dead-time on a single-phase wireless power transfer system is studied in detail. In practice, the dead-time is always placed between the complementary switching pulses of the inverter phase-leg. At higher operating frequencies, the dead-time issues in the resonant inverter become critical, especially as the power level increases. The detailed analysis of the dead-time on a wireless power transfer system is discussed for different operating conditions of the inverter duty-cycle and power factor. The switching characteristics of the wireless power transfer system inverter are analyzed, and the notch phenomenon that appears at the output of the inverter is also discussed. A notch equation based on the observations is derived to predict the notch occurrence during the system operation. Furthermore, the mathematical expressions are presented for different notch conditions. Subsequently, the effect of the notches on the sensitivity and the power transfer of the series-series compensated wireless power transfer system is analyzed. Finally, the approach is verified experimentally on an 8 kW wireless power transfer system prototype, and the results are compared with the theoretical analysis.

42 ENGINEERING↗

Reliability Improvement by Fault-Tolerant Operation of NPC Inverter for Motor Driving

The high-reliability operation of three-level inverters is crucial to prevent equipment damage, process downtime, and economic losses. This article investigates a three-level neutral-point-clamped inverter under all possible combinations of open-circuit and short-circuit faults and proposes a new postfault operation method without adding extra hardware. This method provides comprehensive solution for operations after single and multiple-device failures, increasing the inverter reliability by 24%. This article classified postfault modulations and uncovered previously unknown fault scenarios that can be addressed using the proposed control method. A new postfault modulation based on space vector modulation with virtual vectors is proposed. The feasibility of the proposed control method is verified by simulation and an experiment for one fault scenario in a three-level neutral-point-clamped inverter with a 3.73 kW motor load. Furthermore, this article contributes to improving the reliability of three-level inverters.

42 ENGINEERING↗

A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters

This article presents a space vector pulsewidth modulation (SVPWM) technique for wide bandgap (WBG) device-based three-level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this article, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures dc bus capacitor voltage balancing and minimizes circulating current. Here, the SVPWM technique is experimentally verified using a GaN-based 3L six-phase active neutral point clamped (ANPC) inverter prototype, and the results are presented in this article.

42 ENGINEERING↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗