Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Indoor environmental”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Monitoring and Enhancing Plant Productivity

Researchers at Los Alamos National Laboratory are developing extensive capabilities to improve plant drought tolerance; water and nutrient use efficiency and reduce greenhouse gas emissions from agriculture and natural systems. By monitoring plant function, stress responses, water and nutrient use, greenhouse gas emissions, and analyzing rhizosphere and plant microbiomes, results have shown improved plant performance and stress tolerance, production of plant pro- and prebiotics, and ability to control greenhouse gas emissions from indoor and outdoor agricultural systems. We seek a commercialization partner to fund precision agriculture specific research & development (R&D) through a Cooperative Research and Development Agreement (CRADA). Our goal is to further research and develop our laboratory scale capabilities with a collaborative partner to achieve two goals: 1) reduce the use of water and fertilization in agricultural systems; and 2) create carbon neutral food and energy technologies to support precision agriculture at commercial scale.

54 ENVIRONMENTAL SCIENCES↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying mean, variability, and uncertainty in indoor radon exposure in Pennsylvania using random forest and quantile regression forest models

Radon is a naturally occurring radioactive gas that poses a serious health risk as the primary cause of lung cancer in non-smokers. Despite the well-known adverse association with health outcomes, current radon exposure assessments are limited to county-level or average-level estimates, which fail to capture regional variability. This study uses Machine Learning models, including Random Forest (RF) and Quantile Regression Forest (QRF), to estimate the indoor radon concentrations at the ZCTA (Zip code tabulation area)-level and characterize uncertainties in model estimates. Incorporating geological, meteorological, and building-specific data, the models aim to improve radon risk assessment by capturing mean exposure, variability, and extreme concentration levels. Processed radon test data (n = 718,111) were analyzed using average, variability, and quantile prediction methods. Models that estimate the average radon exposure at the ZCTA-level can yield promising model-fit results, but they do not capture the underlying variability of indoor radon exposure within a ZCTA. We utilize volatility analyses to identify characteristics indicative of high variability of indoor radon exposure. We also show that a QRF model can be used to estimate upper quantiles of residential radon exposure, thereby uncovering localized areas of elevated exposure that were not apparent in mean estimates. The results highlighted the need for a deep characterization of exposure risk and show that regions with moderate average exposure levels could still harbor extreme outliers with implications for evaluating health risks. Utilizing multiple radon exposure models allows for a deeper characterization of radon risk within a geographic area and can better identify high-risk areas. The results from this study provide a foundation for developing mitigation strategies and examining associations between radon exposure and health outcomes at fine scales. Future research should extend the geographic scope and incorporate additional environmental risk factors to establish a comprehensive framework for risk assessment.

Lee, Heechan [ORNL]↗

Ten year environmental test of glass fiber/epoxy pressure vessels

By the beginning of the 1970's composite pressure vessels had received a significant amount of development effort, and applications were beginning to be investigated. One of the first applications grew out of NASA Johnson Space Center efforts to develop a superior emergency breathing system for firemen. While the new breathing system provided improved wearer comfort and an improved mask and regulator, the primary feature was low weight which was achieved by using a glass fiber reinforced aluminum pressure vessel. Part of the development effort was to evaluate the long term performance of the pressure vessel and as a consequence, some 30 bottles for a test program were procured. These bottles were then provided to NASA Lewis Research Center where they were maintained in an outdoor environment in a pressurized condition for a period of up to 10 yr. During this period, bottles were periodically subjected to cyclic and burst testing. There was no protective coating applied to the fiberglass/epoxy composite, and significant loss in strength did occur as a result of the environment. Similar bottles stored indoors showed little, if any, degradation. This report contains a description of the pressure vessels, a discussion of the test program, data for each bottle, and appropriate plots, comparisons, and conclusions.

Faddoul, J. R.↗

Ten year environmental test of glass fiber/epoxy pressure vessels

By the beginning of the 1970's composite pressure vessels had received a significant amount of development effort, and applications were beginning to be investigated. One of the first applications grew out of NASA Johnson Space Center efforts to develop a superior emergency breathing system for firemen. While the new breathing system provided improved wearer comfort and an improved mask and regulator, the primary feature was low weight which was achieved by using a glass fiber reinforced aluminum pressure vessel. Part of the development effort was to evaluate the long term performance of the pressure vessel and as a consequence, some 30 bottles for a test program were procured. These bottles were then provided to NASA Lewis Research Center where they were maintained in an outdoor environment in a pressurized condition for a period of up to 10 yr. During this period, bottles were periodically subjected to cyclic and burst testing. There was no protective coating applied to the fiberglass/epoxy composite, and significant loss in strength did occur as a result of the environment. Similar bottles stored indoors showed little, if any, degradation. This report contains a description of the pressure vessels, a discussion of the test program, data for each bottle, and appropriate plots, comparisons, and conclusions.

Faddoul, J. R.↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

National Virtual Biotechnology Laboratory: Report on Rapid R&D Solutions to the COVID-19 Crisis

With funding from the CARES Act, the U.S Department of Energy (DOE) established the National Virtual Biotechnology Laboratory (NVBL) in March 2020 to address key challenges associated with the COVID-19 crisis. NVBL brought together the broad scientific and technical expertise and resources of DOE’s 17 national laboratories to help tackle medical supply short ages, discover potential drugs to fight the virus, develop and validate COVID-19 testing methods, model disease spread and impact across the nation, and understand virus transport in buildings and the environment. National laboratory resources leveraged for this effort include a suite of world-leading user facilities broadly available to the research community, such as light and neutron sources, nanoscale science research centers, sequencing and biocharacterization facilities, and high-performance computing facilities. Within months, NVBL teams produced innovations in materials and advanced manufacturing that mitigated shortages in test kits and personal protective equipment (PPE), creating nearly 1,000 new jobs. They used DOE’s high-performance computers and light and neutron sources to identify promising candidates for antibodies and antivirals that universities and drug companies are now evaluating. NVBL researchers also developed new diagnostic targets and sample collection approaches, and supported U.S. Food and Drug Administration (FDA), Centers for Disease Control and Prevention (CDC), and U.S. Department of Defense (DoD) efforts to establish national guidelines used in administering millions of tests. Researchers used artificial intelligence and high-performance computing to produce near-real-time data analysis to forecast disease transmission, stress on public health infrastructure, and economic impact, which supported decision-makers at the local, state, and national levels. NVBL teams also studied how to control indoor virus movement to minimize uptake and protect human health. NVBL’s accomplishments demonstrate not only the powerful resource represented by DOE’s national laboratories working together to meet national needs, but also the effectiveness of the integrated NVBL framework for rapidly responding to emergencies with research and development (R&D) solutions. As the fight against COVID continues, sustained efforts are needed to confront this pandemic as well as future threats. Examples include: 1) Establishing “supply chains on demand” to meet emergency production needs by leveraging the materials and manufacturing expertise of DOE national laboratories and developing advances in electronics, sensing, robotics, and automation capabilities; 2) Improving the speed and robustness of drug discovery by integrating experimental platforms with DOE’s computational and experimental user facilities, which provide unique resources to support the discovery of high-potential therapeutic agents; 3) Protecting public, environmental, and animal health by developing new testing protocols and instrumentation adaptable to diverse sample types (both physiological and environmental) to quickly detect a wide range of pathogens and monitor other biorisks; 4) Supporting near-real-time data needs of decision-makers at the local, regional, state, and national levels by advancing data curation, analysis, and modeling using artificial intelligence and new data science tools for managing and evaluating large diverse datasets; 5) Harnessing DOE’s expertise in environmental modeling to design rooms and air handling for offices, classrooms, restaurants, and other structures to minimize biorisk transmissions. Going forward, NVBL is poised to apply the unique capabilities and expertise of the national laboratory complex to future national and international emergencies, both natural and engineered. Through this framework, the Office of Science will continue to be an integral component of agency wide efforts to prepare for and respond to biorisks and other crises.

42 ENGINEERING↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Background and Validation Report on the Residential Water Inhalation Risk Calculator Presented in the Risk Assessment Information System

Indoor air quality (IAQ) is critical for human health. Poor IAQ is linked to respiratory issues, cardiovascular diseases, and cancer. Indoor pollutants are emitted by typical household items such as cleaning products, personal care items, building materials, and tap water - an understudied volatile organic compound (VOC) source. This document presents the Residential Water Inhalation Risk Calculator (RWIRC), which estimates daily VOC exposure concentrations from various household water uses, such as showering and dishwashing, to assess exposure risks for the most vulnerable occupant. Integrated into the Risk Assessment Information System (RAIS) and sponsored by the US Department of Energy (DOE), the calculator divides a house into three compartments: shower, bathroom, and other spaces, accounting for daily water usage patterns and calculating VOC concentrations. Exposure data generated using the calculator can assist health assessors in estimating excess lifetime cancer risk (ELCR) and hazard index (HI) from VOC inhalation. Unlike traditional exposure models that utilize Andelman’s constant, the RWIRC continuously assesses variability in VOC concentrations and environmental conditions using differential equations to track VOC concentrations and air exchange between compartments. The calculator also provides unique volatilization fractions for each chemical and appliance, enhancing accuracy of the exposure concentration estimation. The RWIRC is accessible online and allows users to customize parameters (i.e., number of bathrooms, water temperature, and exhaust fan conditions) and input VOC characteristics (i.e., tap water and ambient air concentrations). This document provides a step-by-step guide on implementing the calculator. It also provides comparisons with the ATSDR-SHOWER calculator, using eight VOCs with varying physicochemical properties to reveal differences in algorithms and output concentrations. Simulations also assess how bathroom door positions and exhaust fan usage affect VOC exposure. The calculator results can enhance EPA risk screening levels for inhalation exposure to VOCs from tap water, offering a sophisticated tool for assessing inhalation risks and improving public health protection.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Characterization of Microorganisms in the Spacecraft Environment

Spacecraft such as the International Space Station (ISS) and the space shuttles are enclosed environments where crewmembers may spend long periods of time. Currently, crewmembers spend approximately a period of 6 months in the ISS. It is known that these prolonged stays in space may result in weakening of the immune system. Therefore, exposure to opportunistic pathogens or high concentrations of environmental microorganisms may compromise the health of the crew. The detection of biocontaminants in spacecraft environments utilizes culture-based methodology, omitting greater than 90% of all microorganisms including pathogens such as Legionella and Cryptosporidium. Culturable bacteria and fungi have been the only allergens studied; the more potent allergens, such as those from dust mites, have never been tested for in spacecraft environments. In addition, no attempts have been made to monitor microbial toxins in spacecrafts. The present study utilized quantitative polymerase chain reaction (QPCR) as a novel approach for monitoring microorganisms in the spacecraft environment. QPCR is a molecular biology technique that does not rely on the physiological state of the organisms for identification, thereby enabling detection of both culturable and non-culturable organisms. In this project, specific molecular primers and probes were utilized for the detection and quantitation of two fungi of concern in indoor environments, Aspergillus fumigatus and Stachybotrys chartarum. These organisms were selected because of the availability of PCR primers and probes, and to establish the sample processing and analysis methodology that may be employed with additional organisms. Purification methods and QPCR assays were optimized for the detection of these organisms in air, surface, and water; and sample processing and analysis protocols were developed. Preliminary validation of these protocols was conducted in the laboratory with air, surface, and water samples seeded with known concentrations of the target organisms. Additional studies were conducted with bulk materials (HEPA filter pleats and particulate found on the filter screen) obtained from the ISS.

Cruz, Patricia↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Time course of sleep inertia dissipation in human performance and alertness

Alertness and performance on a wide variety of tasks are impaired immediately upon waking from sleep due to sleep inertia, which has been found to dissipate in an asymptotic manner following waketime. It has been suggested that behavioural or environmental factors, as well as sleep stage at awakening, may affect the severity of sleep inertia. In order to determine the time course of sleep inertia dissipation under normal entrained conditions, subjective alertness and cognitive throughput were measured during the first 4 h after habitual waketime from a full 8-h sleep episode on 3 consecutive days. We investigated whether this time course was affected by either sleep stage at awakening or behavioural/environmental factors. Sleep inertia dissipated in an asymptotic manner and took 2-4 h to near the asymptote. Saturating exponential functions fitted the sleep inertia data well, with time constants of 0.67 h for subjective alertness and 1.17 h for cognitive performance. Most awakenings occurred out of stage rapid eye movement (REM), 2 or 1 sleep, and no effect of sleep stage at awakening on either the severity of sleep inertia or the time course of its dissipation could be detected. Subjective alertness and cognitive throughput were significantly impaired upon awakening regardless of whether subjects got out of bed, ate breakfast, showered and were exposed to ordinary indoor room light (approximately 150 lux) or whether subjects participated in a constant routine (CR) protocol in which they remained in bed, ate small hourly snacks and were exposed to very dim light (10-15 lux). These findings allow for the refinement of models of alertness and performance, and have important implications for the scheduling of work immediately upon awakening in many occupational settings.

Non-NASA Center↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daytime urban heat stress in North America reduced by irrigation

There is considerable uncertainty regarding the impact of irrigation on heat stress, partly stemming from the choice of heat stress index. Moreover, existing simulations are at scales that cannot appropriately resolve population centres or clouds and thus the potential for human impacts. Using multi-year convection-permitting and urban-resolving regional climate simulations, we demonstrate that irrigation alleviates summertime heat stress across more than 1,600 urban clusters in North America. This holds true for most physiologically relevant heat stress indices. The impact of irrigation varies by climate zone, with more notable irrigation signals seen for arid urban clusters that are situated near heavily irrigated fields. Through a component attribution framework, we show that irrigation-induced changes in wet-bulb temperature, often used as a moist heat stress proxy in the geosciences, exhibit an opposite sign to the corresponding changes in wet bulb globe temperature—a more complete index for assessing both indoor and outdoor heat risk—across climate zones. In contrast, the local changes in both wet-bulb and wet bulb globe temperature due to urbanization have the same sign. Here, our results demonstrate a complex relationship between irrigation and heat stress, highlighting the importance of using appropriate heat stress indices when assessing the potential for population-scale human impacts.

54 ENVIRONMENTAL SCIENCES↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗