Friction and Wear Characteristics of Candidate Foil Bearing Materials from 25 C to 800 C

The friction and wear behavior of unlubricated metal/metal sliding couples was investigated to screen potential candidates for high temperature foil bearings. The tribo-tests were run in an induction-heated high temperature pin-on-disk tribometer in an air atmosphere at a load of 4.9 N and at a sliding velocity of 1 m/s. The friction and wear properties of several nickel based alloys (Rene'41, Inconel X-750, Inconel 713C), iron based alloys (MA956 and Inconel 909) and a ceramic (Al2O3) were tested at 25, 500, and 800 C. In general, at elevated temperatures the alloys oxidized and formed a tenacious and lubricous oxide surface film or layer. At 800 C, Inconel X-750 versus Rene'41 had the lowest friction coefficient (0.27) and at 500 C, Inconel X-750 versus Inconel 909 the lowest pin wear (2.84 x 10(exp -6)cu mm/N-m). Gouging and severe wear of the softer material occurred whenever a significant difference in hardness existed between the pin and disk specimens.

DellaCorte, C.↗

Advanced fabrication techniques for cooled engine structures

An improved design for regeneratively cooled engine structures was identified. This design uses photochemically machined (PCM) coolant passages. It permits the braze joint to be placed in a relatively cool area, remote from the critical hot face sheet. The geometry of the passages at the face sheet also minimizes stress concentration and, therefore, enhances the low cycle fatigue performance. The two most promising alloys identified for this application are Inconel 617 and Nickel 201. Inconel 617 was selected because it has excellent creep rupture properties, while Nickel 201 was selected because of its predicted good performance under low cycle fatigue loading. The fabrication of the PCM coolant passages in both Inconel 617 and Nickel 201 was successfully developed. During fabrication of Inconel 617, undesirable characteristics were observed in the braze joints. A development program to resolve this condition was undertaken and led to definition of an isothermal solidification process for joining Inconel 617 panels. This process produced joints which approach parent metal strength and homogeneity.

Buchmann, O. A.↗

Tungsten wire-reinforced superalloys for 1093 C (2000 F) turbine blade applications

Various combinations of fiber and matrix materials were fabricated and evaluated for the purpose of selecting a specific combination that exhibited the best overall properties for a turbine blade application. A total of seven matrix alloys, including Hastelloy X, Nimonic 80A, Inconel 600, Inconel 625, IN-102, FeCrA1Y, were investigated reinforced with either 218CS tungsten, or W-Hf-C fibers. Based on preliminary screening studies, FeCrA1Y, Inconel 600 and Inconel 625 matrix composites systems were selected for extended thermal cycle tests and for property evaluations which included stress rupture, impact, and oxidation resistance. Of those investigated, the FeCrA1Y matrix composite system exhibited the best overall properties required for a turbine blade application. The W-Hf-C/FeCrA1Y system was selected for further property evaluation. Tensile strength values of up to 724 MPa (105,000 psi) were obtained for this material at 982 C and 607 MPa at 1093 C.

Friedman, G. I.↗

Post-test examination of a pool boiler receiver

A subscale pool boiler test apparatus to evaluate boiling stability developed a leak after being operated with boiling NaK for 791.4 hr at temperatures from 700 to 750 C. The boiler was constructed using Inconel 625 with a type 304L stainless steel wick for the boiler and type 316 stainless steel for the condenser. The boiler assembly was metallurgically evaluated to determine the cause of the leak and to assess the effects of the NaK on the materials. It was found that the leak was caused by insufficient (about 30 pct.) joint penetration in a butt joint. There was no general corrosion of the construction materials, but the room temperature ductility of the Inconel 625 was only about 6.5 pct. A crack in the heat affected zone of the Inconel 625 near the Inconel 625 to type 316 stainless steel butt joint was probably caused by excessive heat input. The crack was observed to have a zone depleted of iron at the crack surface and porosity below that zone. The mechanism of the iron depletion was not conclusively determined.

Dreshfield, Robert L.↗

Cryogenic Brush Seal Test Results

Brush seals are compliant, contact seals that have long-life, low-leakage characteristics desirable for use in rocket engine turbopumps. 50.8-mm (2.0 inch) diameter brush seals with a nominal initial radial interference of 0.127-mm (0.005 inch) were tested in liquid nitrogen at shaft speeds up to 35,000 rpm and differential pressure loads up to 1.21 MPa (175 psi) per brush. The measured leakage rate of a single brush was 2-3 times less than that measured for a 12-tooth, 0.127-mm (0.005 inch) radial clearance labyrinth seal used as a baseline. Stage effects were studied and it was found that two brush seals with a large separation distance leaked less than two brushes tightly packed together. The maximum measured groove depth on the Inconel 718 rotor was 25.4 (mu)m (0.001 inch) after 4.31 hours of shaft rotation. The Haynes-25 bristles wore approximately 25.4-76.2 (mu)m (0.001-0.003 inch) under the same conditions. Three seal runner coatings, chromium carbide, Teflon impregnated chromium, and zirconium oxide, were tested in liquid hydrogen at 35,000 and 65,000 rpm with separate 50.8 mm diameter brush seals made of Haynes-25 bristles and having a nominal initial radial interference of 129 rpm. Two bare Inconel-718 rotors were also tested as a baseline. The test results revealed significant differences between the wear characteristics of the uncoated and coated seal runners. At both speeds the brush seal with the bare Inconel-718 seal runner exhibited significant bristle wear with excessive material transferring to the runner surface. In contrast, the coated seal runners inhibited the transfer and deposit of bristle material. The chromium carbide coating showed only small quantities of bristle material transferring to its surface. The Teflon impregnated chromium coating also inhibited material transfer and provided some lubrication. This coating, however, is self-sacrificing. The Teflon remained present on the low speed runner, but it was completely removed from the high speed brush seal, which was tested considerably longer. The tests of the Teflon coating revealed the importance of using a lubricating and low friction coating for brush seals to reduce bristle and seal runner wear. The zirconium oxide coating exhibited the greatest amount of coating wear, while the brushes incurred only slight wear. Further testing of ceramics is recommended before making a final judgement on the viability of ceramic coatings for brush seals because of the contrast between the results reported by Carlile and the results presented herein. Strictly based on the results presented hereinabove, the chromium carbide and Teflon impregnated chromium coatings were considered preferable to the uncoated Inconel-718 and zirconium oxide coatings because of their good wear resistance and characteristics to inhibit bristle material wear and transfer to the seal runner.

Proctor, Margaret P.↗

Improved Seals for High Temperature Airframe Applications

Current thermal barrier seals, such as those used on the Space Shuttle, are insufficient to fully meet the demands of future hypersonic vehicles and reentry spacecraft. Previous investigations have demonstrated limited usage temperatures, as evidenced by a decreased ability to maintain sealing effectiveness at high temperatures (i.e., inadequate resiliency). In order to improve resiliency at elevated temperatures, Rene 41 (Allvac) was substituted for Inconel X-750 (Special Metals Corp.) as the spring tube material in the existing seal design. A seal construction incorporating the Rene 41 spring tube was fabricated and tested against the baseline Inconel X-750 spring tube seal. Although resiliency improvements were not as dramatic as in previous tests with the spring tubes alone, seals incorporating the Rene 41 spring tube exhibited an average 20 percent resiliency enhancement up to 1750 F when compared to seals containing the Inconel spring tube. In addition, the seals with the Rene 41 spring tubes showed less reduction in resiliency as temperatures increased above 1200 F. Results also indicated the Saffil (Saffil Ltd.) insulation in the core of the seal contributed more to resiliency than previously thought. Leakage data did not demonstrate an improvement with the seal containing the Rene 41 spring tube. However, based upon resiliency results, one could reasonably expect the Rene 41 version of the seal to track gap openings over a wider range. Therefore it would exhibit lower leakage than the Inconel X-750 version as the seal gap opens during a typical mission.

DeMange, Jeffrey J.↗

Ignition of Metals in Heated Supersonic Particle Impact with Inert Particulate

The conventional understanding of particle impact ignition characteristic elements relies on the following principles: 1) flammable particulate (except in the case of titanium and aluminum target materials); 2) gas velocity greater than 100 ft/s; 3) Impact point ranging from 45° to perpendicular to the path of the particle [1]; 4) flammable target material. To test assumptions about particulate flammability being necessary for particle impact ignition of less reactive target materials, such as Inconel 718, testing was performed with inert particulate. Supersonic particle impact testing was conducted with heated gas and 1500-µm sapphire particulate on various target materials: 304 stainless steel, wrought and selective laser melted Inconel 718, and Monel 400. Posttest characterization of impact craters was performed on each type of metallic target sample, including surface characterization performed by light optical microscopy and scanning electron microscopy with energy dispersive spectroscopy. Full consumption of the stainless steel and wrought Inconel 718 targets were noted to occur with sequential impacts. The results of testing will be discussed in detail, as well as recommendations for updating the understanding of the particle impact ignition mechanism.

Particle Impact↗

LUBRICATING PROPERTIES OF CERAMIC-BONDED CALCIUM FLUORIDE COATINGS ON NICKEL-BASE ALLOYS FROM 75 DEG TO 1900 DEG F

The endurance life and the friction coefficient of ceramic-bonded calcium fluoride (CaF2) coatings on nickel-base alloys were determined at temperatures from 75° to 1900° F. The specimen configuration consisted of a hemispherical rider (3/16-in. rad.) sliding against the flat surface of a rotating disk. Increasing the ambient temperature (up to 1500° F) or the sliding velocity generally reduced the friction coefficient and improved coating life. Base-metal selection was critical above 1500° F. For instance, cast Inconel sliding against coated Inconel X was lubricated effectively to 1500° F, but at 1600° F severe blistering of the coatings occurred. However, good lubrication and adherence were obtained for René 41 sliding against coated René 41 at temperatures up to 1900° F; no blisters developed, coating wear life was fairly good, and the rider wear rate was significantly lower than for the unlubricated metals . Friction coefficients were 0.12 at 1500° F, 0.15 at 1700° F, and 0.17 at 1800° and 1900° F. Because of its ready availability, Inconel X appears to be the preferred substrate alloy for applications in which the temperature does not exceed 1500° F. René 41 would have to be used in applications involving higher temperatures. Improved coating life was derived by either preoxidizing the substrate metals prior to the coating application or by applying a very thin (<0.0002 in.) burnished and sintered overlay to the surface of the coating. Preoxidation did not affect the friction coefficient. The overlay generally resulted i n a higher friction coefficient than that obtained without the overlay. The combination of both modifications resulted in longer coating life and in friction coefficients intermediate between those obtained with either modification alone.

Nickel alloy↗

Electron emission from nickel-alloy surfaces in cesium vapor

An experimental apparatus and measurement techniques are described for measuring the thermionic emission from cesium-activated materials having adequate high-temperature properties such as creep strength and corrosion resistance, which might ultimately reduce the cost of thermionic converters. The electron emission characteristics are measured for nickel, Inconel 600, and Hastelloy X probes with a 412 K cesium reservoir. It is found that the nickel alloys exhibit a peak electron emission 1.4 to 2.1 times greater than pure nickel. Both the Inconel and the Hastelloy samples have work functions of 1.64 eV at peak emission. The minimum cesiated work functions are estimated to be 1.37 eV for Inconel at a probe temperature of 750 K and 1.4 eV for Hastelloy at a probe temperature of 665 K. The bare work functions for both alloys is estimated to be about the same as for pure nickel, 4.8 eV.

Manda, M.↗

Electron emission from nickel-alloy surfaces in cesium vapor

The cesiated electron emission was measured for three candidate electrodes for use as collectors in thermionic converters. Nickel, Inconel 600 and Hastelloy were tested with a 412 K cesium reservoir. Peak emission from the alloys was found to be comparable to that from pure nickel. Both the Inconel and the Hastelloy samples had work functions of 1.64 eV at peak emission. The minimum work functions were estimated to be 1.37 eV at a probe temperature of 750 K for Inconel and 1.40 eV for Hastelloy at 665 K. The bare work function for both alloys is estimated to be approximately the same as for pure nickel, 4.8 eV.

Manda, M.↗

Ceramic-to-metal bonding for pressure transducers

A solid-state diffusion technique involving the placement of a gold foil between INCONEL X-750 and a machinable glass-ceramic "MACOR" was shown to be successful in bonding these two materials. This technique was selected after an exhaustive literature search on ceramic-metal bonding methods. Small expansion mismatch between the Inconel and the MACOR resulted in fracture of the MACOR when the bonded body was subjected to tensile stress of 535 psi. The bonded parts were submitted to a cyclic loading test in an air atmosphere at 1 Hz from 0 to 60 KPa. Failure was observed after 700,000 cycles at 650 C. Ceramic-Inconel bonding was not achieved with this method for boron nitride and silica glass.

Mackenzie, J. D.↗

Spray automated balancing of rotors: Methods and materials

The work described consists of two parts. In the first part, a survey is performed to assess the state of the art in rotor balancing technology as it applies to Army gas turbine engines and associated power transmission hardware. The second part evaluates thermal spray processes for balancing weight addition in an automated balancing procedure. The industry survey reveals that: (1) computerized balancing equipment is valuable to reduce errors, improve balance quality, and provide documentation; (2) slow-speed balancing is used exclusively, with no forseeable need for production high-speed balancing; (3) automated procedures are desired; and (4) thermal spray balancing is viewed with cautious optimism whereas laser balancing is viewed with concern for flight propulsion hardware. The FARE method (Fuel/Air Repetitive Explosion) was selected for experimental evaluation of bond strength and fatigue strength. Material combinations tested were tungsten carbide on stainless steel (17-4), Inconel 718 on Inconel 718, and Triballoy 800 on Inconel 718. Bond strengths were entirely adequate for use in balancing. Material combinations have been identified for use in hot and cold sections of an engine, with fatigue strengths equivalent to those for hand-ground materials.

Smalley, Anthony J.↗

Study of metal corrosion using ac impedance techniques in the STS launch environment

AC impedance measurements were performed to investigate the corrosion resistance of 19 alloys under conditions similar to the STS launch environment. The alloys were: Zirconium 702, Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, Inconel 600, 7Mo + N, Ferralium 255, Inco Alloy G-3, 20Cb-3, SS 904L, Inconel 825, SS 304LN, SS 316L, SS 317L, ES 2205, SS 304L, Hastelloy B-2, and Monel 400. AC impedance data were gathered for each alloy after one hour immersion time in each of the following three electrolyte solutions: 3.55 percent NaCl, 3.55 percent NaCl-0.1N HCl, and 3.55 percent NaCl-1.0N HCl. The data were analyzed qualitatively using the Nyquist plot and quantitatively using the Bode plot. Polarization resistance, Rp, values were obtained using the Bode plot. Zirconium 702 was the most corrosion resistant alloy in the three electrolytes. The ordering of the other alloys according the their resistance to corrosion varied as the concentration of hydrochloric acid in the electrolyte increased. The corrosion resistance of Zirconium 702 and Ferralium 255 increased as the concentration of hydrochloric acid in the electrolyte increased. The corrosion resistance of the other 17 alloys decreased as the concentration of the hyrdochloric acid in the electrolyte increased.

Calle, Luz M.↗

Properties data for opening the Galileo's partially unfurled main antenna

An investigation was conducted into the friction and wear behavior of both unlubricated and dry-film-lubricated (Tiolube 460) titanium alloy (Ti-6Al-4V) in contact with an uncoated high-nickel-content superalloy (Inconel 718) both in vacuum and in air. The acquisition of friction and wear data for this sliding couple was motivated by the need for input data for the 'antenna stuck ribs model' effort to free Galileo's High Gain Antenna. The results of the investigation indicate that galling occurred in the unlubricated system in vacuum and that the coefficient of friction increased to 1.2. The abnormally high friction (1.45) was observed when relatively large wear debris clogged at the sliding interface. The coefficient of friction for the dry-film-lubricated system in vacuum is 0.04, while the value in air is 0.13. The endurance life of the dry-film lubricant is about three orders of magnitude greater in vacuum than in air. The worn surfaces of the dry-film-lubricated Ti-6Al-4V pin and Inconel 718 disk first run in humid air and then rerun in vacuum was completely different from that of the pin and disk run only in vacuum. When galling occurred in the humid-air and vacuum contact, coefficient of friction rose to 0.32 when sliding in humid air and to 1.4 when sliding in vacuum. The galling was accompanied by severe surface damage and extensive transfer of the Ti-6Al-4V to the Inconel 718, or vice versa. When spalling occurred in the dry-film-lubricated Ti-6Al-4V pin run only in vacuum, the coefficient of friction rose to 0.36 or greater. The wear damage caused by spalling can self-heal when rerun in vacuum - the coefficient of friction decreased to 0.05. The friction and wear data obtained can be used for the 'antenna stuck ribs model' effort to free Galileo's high gain antenna.

Miyoshi, Kazuhisa↗

Rupture Strength of Several Nickel-base Alloys in Sheet Form

The 100-hour rupture strengths of Inconel X, Inconel 700, Incoloy 901, Refractaloy 26, and R-235 at 1200 and 1350 F. in both the annealed and heat-treated conditions were determined. Inconel 700 had the highest rupture strength at both temperatures; Incoloy 901 was second strongest at 1200 F, and R-235 second strongest at 1350 F. With the exception of Incoloy 901, ductility was low. Photomicrographs show that fractures are through the grain boundaries. Results are compared with published data for other sheet alloys and bar stock.

ALLOYS, HEAT-RESISTING↗

Lubricating Properties of Ceramic-Bonded Calcium Fluoride Coatings on Nickel-Base Alloys from 75 to 1900 deg F

The endurance life and the friction coefficient of ceramic-bonded calcium fluoride (CaF2) coatings on nickel-base alloys were determined at temperatures from 75 F to 1900 F. The specimen configuration consisted of a hemispherical rider (3/16-in. rad.) sliding against the flat surface of a rotating disk. Increasing the ambient temperature (up to 1500 F) or the sliding velocity generally reduced the friction coefficient and improved coating life. Base-metal selection was critical above 1500 F. For instance, cast Inconel sliding against coated Inconel X was lubricated effectively to 1500 F, but at 1600 F severe blistering of the coatings occurred. However, good lubrication and adherence were obtained for Rene 41 sliding against coated Rene 41 at temperatures up to 1900 F; no blisters developed, coating wear life was fairly good, and the rider wear rate was significantly lower than for the unlubricated metals. Friction coefficients were 0.12 at 1500 F, 0.15 at 1700 F, and 0.17 at 1800 F and 1900 F. Because of its ready availability, Inconel X appears to be the preferred substrate alloy for applications in which the temperature does not exceed 1500 F. Rene 41 would have to be used in applications involving higher temperatures. Improved coating life was derived by either preoxidizing the substrate metals prior to the coating application or by applying a very thin (less than 0.0002 in.) burnished and sintered overlay to the surface of the coating. Preoxidation did not affect the friction coefficient. The overlay generally resulted in a higher friction coefficient than that obtained without the overlay. The combination of both modifications resulted in longer coating life and in friction coefficients intermediate between those obtained with either modification alone.

Sliney, Harold E.↗

Optimum Design of Insulated Compression Plates Subjected to Aerodynamic Heating

A method to determine the optimum thicknesses of insulation and load-carrying structure has been applied to insulated compression plates subjected to aerodynamic heating. The optimum design results in the lowest combined weight of insulation and load-carrying plate. Load parameters which included the imposed load, insulation conductivity and density, and flight time were found for design strength criteria of compressive yield, compressive buckling, and postbuckling failure. Charts of optimum total weight were prepared for 2024-T3 aluminum alloy, HK3lA magnesium alloy, 17-7 PH stainless steel, and Inconel X for each design criterion. The results show that 17-7 PH stainless steel and Inconel X are most efficient for compressive yield stress and that HK3lA magnesium is most efficient for buckling. HK31A magnesium is also most efficient for the postbuckling failure criterion except under conditions of light loading and long flight periods; under such conditions uninsulated Inconel X may be superior for environmental temperature less than 1,200 F. Insulated magnesium is more efficient than insulated aluminum because the lower density of magnesium permits the use of thick plates with large heat capacity. When more than one failure mode was applied to a design, it was found that the minimum weight structure was one in which all modes of failure occurred at the design load.

Davidson, John R.↗

Permeability of Candidate Stirling Heater Head Materials Measured

Researchers at the NASA Glenn Research Center are evaluating high-temperature materials for Stirling heater heads for second- and third-generation Stirling radioisotope power systems that would help to increase the system efficiency to 30 to 35 percent and the system specific power to 8 to 10+ W/kg. Ceramic materials could make it possible for the convertor hot-end temperature to be increased to 1050 to 1200 C, in comparison to the current 650 C with an Inconel 718 heater head. A hermetically sealed Stirling heater head must retain a constant internal pressure of nearly 400-psi helium (He) throughout its useful life (120,000 hr) at the design operating temperature. Therefore, He permeability was measured for eight potential materials and compared with the permeability of the current heater head material, Inconel 718. The eight materials included silicon nitride (Si3N4), silicon dioxide (SiO2), both sintered and chemical vapor deposited (CVD) silicon carbide (SiC), alumina (Al2O3), two types of melt-infiltrated (MI) SiC/SiC composites, and a carbon/SiC composite (C/SiC). Glenn submitted samples of each material to Porous Materials, Inc., Ithaca, New York, for permeability analysis. At room temperature and 30-psi He, four materials--Si3N4, Al2O3, SiO2, and sintered SiC--demonstrated lower permeability than Inconel 718. The CVD SiC and all the composite materials were significantly more permeable to He than the baseline material.