Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Instrumentation development for the EUVE

The prototype mirror was successfully replated with a thick layer of nickel and diamond turned again. Optimization of the sensitivity of the instruments was studied with emphasis on the filter material, and on the available telemetry. The JHU Preliminary Project Definition Document was critically analyzed. Further studies of the electron cloud distribution produced by a channel plate were performed, and a wedge and strip anode with 17 quartets per inch was shown to image with better than 0.5% linearity. Half the microchannel plates being used in the lifetest completed initial processing and are in the lifetest vacuum chamber.

Finley, D.↗

A Novel Ultrasonic Method for Characterizing Microstructural Gradients in Tubular Structures

Ultrasonic velocity and time-of-flight (TOF) imaging that uses back surface reflections to gage volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse echo ultrasonic velocity and TOF imaging is that the image shows the effects of thickness as well as microstructural variations, unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse echo TOF based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples which, eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material in plate like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex shaped structures- those having (hollow) tubular or curved geometry. The experimental inspection technique and results are described as applied to a polymer matrix composite "proof of concept" tube that contains machined patches of various depths and an as manufactured monolithic silicon nitride ceramic tube that might be used in "real world" applications.

Roth, Don J.↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

Readout techniques for photon-counting microchannel image systems

A comparative evaluation is made of such readout methods for the microchannel plates that are commonly used in EUV, FUV, and X-ray low light level image systems as the (1) phosphor-video, (2) phosphor and binary-mask encoder, (3) direct discrete-position encoder, (4) direct analog amplitude position-encoder systems, and (5) delay-line encoders. Relative advantages and limitations are discussed in the context of low light level space-based astronomy applications. The delay-line technique offers great promise for high-resolution applications where oversampling is mandatory, as in spectroscopy.

Lampton, Michael↗

Scaling up the Single Transducer Thickness-Independent Ultrasonic Imaging Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.

Roth, Don J.↗

Laser ranging system with 1-cm resolution.

A laser ranging system has been developed in which an image converter tube equipped with deflection plates is used to make a precise measurement of the fractional amount by which the time of flight of the ranging pulse exceeds an integral multiple N of the period of a stable oscillator. The value of N is determined in an auxiliary measurement. In short-range tests with a laboratory breadboard version of the system, time-of-flight uncertainties of about 45 psec were observed. The corresponding uncertainty in a range measurement is smaller than 7 mm.

Golden, K. E.↗

Measuring Flow With Laser-Speckle Velocimetry

Spatial resolution sufficient for calculation of vorticity.In laser-speckle velocimetry, pulsed or chopped laser beam expanded in one dimension by cylindrical lens to illuminate thin, fan-shaped region of flow measured. Flow seeded by small particles. Lens with optical axis perpendicular to illuminating beam forms image of illuminated particles on photographic plate. Speckle pattern of laser-illuminiated, seeded flow recorded in multiple-exposure photographs and processed to extract data on velocity field. Technique suited for study of vortical flows like those about helicopter rotor blades or airplane wings at high angles of attack.

Smith, C. A.↗

Charge coupled devices vs. microchannel plates in the extreme and far ultraviolet - A comparison based on the latest laboratory measurements

While microchannel plates (MCPs) have been established as imaging photon counters in the EUV and FUV for some years, CCDs are associated with low light level sensing at visible and near-IR wavelengths. Attention is presently given to recent proposals for CCDs' use as EUV and FUV detectors with quantum efficiencies sometimes exceeding those of MCPs; quantum resolution, format size, dynamic range, and long-term stability are also used as bases of comparison, for the cases of both space-based astronomical and spectroscopic applications.

Vallerga, J.↗

Stripping of gas and dust from the elliptical galaxy M86

Past observations of the x ray morphology of M86 have revealed that the galaxy is experiencing ram-pressure stripping due to its large velocity (1500 km s(-1)) relative to the intracluster medium of Virgo (Forman et al. 1979, Fabian, Schwartz, and Forman 1980). Observations indicate that the x ray emitting gas in the plume of M86 is still being produced from the continual heating of gas and dust stripped from nearer the galaxy's center. Researchers obtained two-dimensional Infrared Astronomy Satellite (IRAS) images of M86 which have revealed that there are two spatially separated regions of emission, one at 60 microns and the other at 100 microns of the IRAS wavebands. The 100 microns emission, presumably from cool dust (at approximately 20 K), appears to be located near the center of the galaxy together with HI (detected by Bregman, Roberts and Giovanelli 1988), while the 60 microns emission appears to lie more than 3 arcminutes away from the optical center in a direction slightly south of the center of the plume. Optical images produced by scanning U.K. Schmidt plates, reveal asymmetric isophotal contours along the major axis of the galaxy (first reported by Nulsen and Carter in 1987, which they propose as excess emission due to star formation). This excess optical emission is co-incident with the direction of the 60 micron infra-red emission.

White, D. A.↗

An infrared/optical investigation of 100 micron 'cirrus'

IRAS Skyflux images, in conjunction with ESO/SRC photographic plates, are presently used to study a sample of 151 compact cyrrus sources. IR colors entail at least two dust components; a simple two-temperature dust model yields a mean physical temperature of 22.5 + or - 0.3 K for the warm dust, and 173 + or - 8 K for the hot dust, which constitutes 15-42 percent of total IR luminosity. A variable proportion of cold dust may contribute significantly to the optical brightness in two isolated cloud complexes.

Paley, Elizabeth S.↗

Microbial Responses to Radiation at the Single-Cell Level

Exploring the biological effects of deep space radiation is crucial for developing protective protocols for humans traveling beyond Earth’s magnetosphere. Saccharomyces cerevisiae, or budding yeast, is an ideal model organism to study the effects of radiation on eukaryotes as it shares several pathways with humans, including DNA repair mechanisms. Here, we used time-lapse imaging of colony growth on agar plates to monitor the effects of radiation exposure on individual yeast cells and their progeny.

Paola J. Maldonado Martinez↗

Stokes parameters modulator for birefringent filters

The Solar Birefringent Filter (Filter Polarisiant Solaire Selectif FPSS) of Meudon Observatory is presently located at the focus of a solar refractor with a 28 cm lens directly pointed at the Sun. It produces a diffraction limited image without instrumental polarization and with a spectral resolution of 46,000 in a field of 6 arc min. diameter. The instrument is calibrated for absolute Doppler velocity measurements and is presently used for quantitative imagery of the radial velocity motions in the photosphere. The short period oscillations are recorded. Work of adapting the instrument for the imagery of the solar surface in the Stokes parameters is discussed. The first polarizer of the birefringent filter, with a reference position angle 0 deg, is associated with a fixed quarter wave plate at +45 deg. A rotating quarter wave plate is set at 0 deg and can be turned by incremented steps of exactly +45 deg. Another quarter wave plate also initially set at 0 deg is simultaneously incremented by -45 deg but only on each even step of the first plate. A complete cycle of increments produces images for each of the 6 parameters I + or - Q, I + or - U and I + or - V. These images are then subtracted by pairs to produce a full image in the three Stokes parameters Q, U and V. With proper retardation tolerance and positioning accuracy of the quarter wave plates, the cross talk between the Stokes parameters was calculated and checked to be minimal.

Dollfus, A.↗

Directional emittance surface measurement system and process

Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

Puram, Chith K.↗

Remote measurement of in-plane diffusivity components in plates

A method of determining thermal diffusivity in thin plates is presented. The method, using infrared images of evolving thermal patterns previously injected with a laser, is noncontacting, one-sided, and remote. It does not require independent estimates of either the emissivity of the sample or the sample thickness. With a line-segment pattern for thermal input, it yields the inplane components of the diffusivity tensor in anisotropic materials and also the rate of heat loss to the environment of the plate. Two methods of data analysis are presented, one corresponding to a heating line of general cross section and the other considering a Gaussian cross section, thereby saving considerable computer time. Both methods produce a statistical evaluation of measurement quality as well as estimates of diffusivity and loss rate. Results are shown for plates of metals and graphite-epoxy composite materials. Principal components and orientation for the diffusivity tensor are obtained in the anisotropic graphite-epoxy sample.

Welch, Christopher S.↗

Various Types of Defects Detection in Flat and Curved Laminated Composite Plates using Nonintrusive Lamb Wave System

Composite materials are widely used in aerospace industries due to their light weight, strength, and various other desired properties. However, they are susceptible to various defects occurring during the manufacturing process or in service. Typical defects include porosity, wrinkles, and delamination. Nondestructive means of detection of the defects at any stage are of great importance to ensure quality and safety of composite structures. A nonintrusive removeable Lamb wave system and accompanied methodology that is not material-dependent is presented in this paper to detect various types of typical defects in laminated composite plates, flat or curved. Through multidimensional data acquisition and processing, abnormality in waves caused by defects is captured and presented in inspection images. The methodologies are demonstrated in 2 cases: flat plate with wrinkles, and curved plate with delamination. Overall the results show that Lamb waves using the piezoelectric transducer and laser vibrometer system can be used for various types of defects inspection in flat or curved composite plates.

composite structures↗

Rapid enumeration of viable bacteria by image analysis

A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.

Non-NASA Center↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Chiron: Evidence for historic cometary activity

The non-asteroidal brightening of (2060) Chiron, first noted by Tholen in 1988 is now ascribed to cometary activity. Photometry since 1988 has revealed a broad surge in brightness that peaked in 1989 about 1.0 mag above the brightness in the mid-1980s. The surge is evidently due to sporatic formation of dust coma, which is itself driven by the presence of extremely volatile ices at or near the surface. CN emission was recently reported. Since Chiron is now nearing perihelion, there is interest in determining whether it has exhibited anomalous brightening in the past, particularly at greater heliocentric distances. Photographic plates dating back to 1895 are known to contain images of Chiron. Using some of these archival material, the initial results are presented for a project to determine Chiron's brightness history over orbital timescales. A particularly homogeneous and high-quality set of plates taken prior to and around the time of Chiron's discovery in Oct. 1977 at the 1.2 m Oschin Schmidt telescope at Mt. Palomar Observatory were examined. Images of Chiron were identified and digitized using a PDS microdensitometer, and images of field stars around Chiron were both similarly digitized and photometrically calibrated using recently acquired B and V band CCD frames. As a result of the present work, eleven new data, including estimated errors, were added between 1969 and 1977. The implications that Chiron can be active at any heliocentric distance in its present orbit suggest that the active volatile is either N2, CH4, or CO, and that a substantial degree of mantling may have developed. Further historical data is presented, the error bars discussed, and possible mechanisms suggested for the observed activity.

Bus, Schelte J.↗