Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IODINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Advanced combined iodine dispenser and detector

A total weight of 1.23 kg (2.7 lb), a total volume of 1213 cu m (74 cu in), and an average power consumption of 5.5W was achieved in the advanced combined iodine dispenser/detector by integrating the detector with the iodine source, arranging all iodinator components within a compact package and lowering the parasitic power to the detector and electronics circuits. These achievements surpassed the design goals of 1.36 kg (3.0 lb), 1671 cu m (102 cu in) and 8W. The reliability and maintainability were improved by reducing the detector lamp power, using an interchangeable lamp concept, making the electronic circuit boards easily accessible, providing redundant water seals and improving the accessibility to the iodine accumulator for refilling. The system was designed to iodinate (to 5 ppm iodine) the fuel cell water generated during 27 seven-day orbiter missions (equivalent to 18,500 kg (40,700 lb) of water) before the unit must be recharged with iodine crystals.

Lantz, J. B.↗

Efficacy of copper and silver ions with iodine in the inactivation of Pseudomonas cepacia

Alternatives to chlorination of water have been sought for reasons which include trihalomethane formation, possible bacterial regrowth, the high concentrations of chlorine required in certain circumstances, and the taste, odour and bodily irritation in chlorine-treated water. Electrolytically generated Cu and Ag ions at low levels, in addition to very low chlorine concentrations, have been suggested as an alternative to routine chlorination. We have examined the combination of Cu and Ag ions with low levels of iodine. Pseudomonas cepacia was grown either in rich medium or under nutrient restriction prior to disinfection. Survival of the organism and its ability to regrow after treatment as well as the effects of varying buffers, metal ion and iodine concentrations were determined. Low concentrations of metal ions (100 ppb Cu and 11 ppb Ag) and iodine (200 ppb) were more effective than either metal ions or iodine alone against Ps. cepacia grown on rich agar or in low nutrient buffer. After iodination, buffer-grown suspensions recovered to their original cell concentrations within 7 d. When Cu and Ag ions were used with or without iodine, regrowth was prevented. The results show that low concentrations of Cu and Ag in combination with iodine permit effective disinfection of bacteria after cultivation on either rich media or under nutrient restriction. These results, along with published data, suggest that the combination of these metals with halogenation may have applications in the disinfection of both recreational and potable water.

NASA Discipline Environmental Health↗

AGING AND IODINE LOADING OF SILVER-FUNCTIONALIZED AEROGELS

Engineered silver-functionalized silica aerogels are being investigated for their application in off-gas treatment at a used nuclear fuel reprocessing facility. Reprocessing will release several key volatile radionuclides, including iodine-129. To achieve regulatory compliance, iodine-129 must be removed from any off-gas stream prior to environmental discharge. Silver-functionalized aerogels have been demonstrated to have high iodine capture capacity, high porosity and potential for conversion into a waste form. Capture materials used in off-gas treatment may be exposed to a heated, high humidity, acidic gas stream for months. Extended exposure to this stream could affect sorbent performance. It was the aim of this study to evaluate what impacts might be observed when Ag0-functionalized aerogels prepared at Pacific Northwest National Laboratory were contacted with a dry air stream for up to 6 months and then used to adsorb iodine from a synthetic off-gas stream. Results demonstrate that there is some loss of iodine capture capacity caused by aging, but that this loss is not as marked as for aging of more traditional iodine sorbents, such as silver-impregnated mordenite. Specifically, aging silver-functionalized aerogel under a dry air stream for up to 6 months can decrease its iodine capacity from 41wt% to 32wt%.

Bruffey, Stephanie H↗

A Crosslinked Ionic Organic Framework for Efficient Iodine and Iodide Remediation in Water

Iodine is widely used as an antimicrobial reagent for water disinfection in the wilderness and outer space, but residual iodine and iodide need to be removed for health reasons. Currently, it is challenging to remove low concentrations of iodine and iodide in water (~5 ppm). Furthermore, the remediation of iodine and iodide across a broad temperature range (up to 90 °C) has not previously been investigated. In this work, we report a nitrate dimer-directed synthesis of a single-crystalline ionic hydrogen-bonded crosslinked organic framework (HCOF-7). HCOF-7 removes iodine and iodide species in water efficiently through halogen bonding and anion exchange, reducing the total iodine concentration to 0.22 ppm at room temperature. Packed HCOF-7 columns were employed for iodine/iodide breakthrough experiments between 23 and 90 °C, and large breakthrough volumes were recorded (≥18.3 L/g). Finally, the high iodine/iodide removal benchmarks recorded under practical conditions make HCOF-7 a promising adsorbent for water treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT

Purpose: Multidetector computed tomography (MDCT) is used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases. Tumor detection can be improved using rapid kV-switching dual-energy CT (rsDECT) and iodine maps. Our aim this study is to evaluate tumor conspicuity in PDAC cases using rsDECT and iodine maps. Methods: Ninety cases with PDAC were evaluated rsDECT. Tumor contrast (HU) differences, tumor size, CNR (contrast-noise ratio), and noise were measured at 70 keV, individual CNR-energy level, and 45 keV, respectively. Quantitative differences in contrast gain ∆70-CNR and ∆CNR-45 were compared. On iodine maps, the iodine concentration measured in the tumor and parenchyma was normalized to the aorta as normalized iodine concentration (NIC) and compared. Results: The median optimized viewing energy level was 51 keV. The mean ± SD tumor contrast values were 62 ± 20, 115 ± 48, and 152 ± 48 HU (p < 0.001); the largest axial diameters were 36.6 ± 5.1, 37.9 ± 4.2, and 38.3 ± 3.7 mm (p = 0.015); the CNRs were 1.83 ± 0.72, 3.37 ± 0.93, and 2.36 ± 0.56; and the image noise levels were 23.7 ± 6.8, 39.3 ± 11.6, and 59.5 ± 17.2 (p < 0.001) (p < 0.001) for 70 keV, optimized energy level, and 45 keV, respectively. The mean ± SD contrast gain ∆70-CNR was 63 ± 12; and ∆CNR-45 was 31 ± 26 HU (p < 0.001). NIC{sub tumor} and NIC{sub parenchyma} values were 0.62 ± 0.03 and 1.36 ± 0.05 mg/mL, respectively (p = 0.004). Conclusion: The use of low energy levels on rsDECT and iodine maps improves tumor conspicuity. This situation may be help better detection of pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined effects of perchlorate, thiocyanate, and iodine on thyroid function in the National Health and Nutrition Examination Survey 2007–08

Perchlorate, thiocyanate, and low iodine intake can all decrease iodide intake into the thyroid gland. This can reduce thyroid hormone production since iodide is a key component of thyroid hormone. Previous research has suggested that each of these factors alone may decrease thyroid hormone levels, but effect sizes are small. We hypothesized that people who have all three factors at the same time have substantially lower thyroid hormone levels than people who do not, and the effect of this combined exposure is substantially larger than the effects seen in analyses focused on only one factor at a time. Using data from the 2007–2008 National Health and Nutrition Examination Survey, subjects were categorized into exposure groups based on their urinary perchlorate, iodine, and thiocyanate concentrations, and mean serum thyroxine concentrations were compared between groups. Subjects with high perchlorate (n=1939) had thyroxine concentrations that were 5.0% lower (mean difference=0.40 μg/dl, 95% confidence interval=0.14–0.65) than subjects with low perchlorate (n=2084). The individual effects of iodine and thiocyanate were even smaller. Subjects with high perchlorate, high thiocyanate, and low iodine combined (n=62) had thyroxine concentrations 12.9% lower (mean difference=1.07 μg/dl, 95% confidence interval=0.55–1.59) than subjects with low perchlorate, low thiocyanate, and adequate iodine (n=376). Potential confounders had little impact on results. Overall, these results suggest that concomitant exposure to perchlorate, thiocyanate, and low iodine markedly reduces thyroxine production. This highlights the potential importance of examining the combined effects of multiple agents when evaluating the toxicity of thyroid-disrupting agents. -- Highlights: ► Recent data suggest that essentially everyone in the US is exposed to perchlorate. ► Perchlorate exposure may be associated with lower thyroid hormone levels. ► Some groups may be more susceptible to perchlorate than others.

60 APPLIED LIFE SCIENCES↗

Silver-Loaded Xerogel Nanostructures for Iodine Capture: A Comparison of Thiolated versus Unthiolated Sorbents

Here this paper describes the development and provides comparisons of thiolated (-SH) and unthiolated Ag-Al-Si-O xerogels for iodine gas capture. These xerogels were produced from alkoxides and then heat-treated at 350 °C to provide mechanical strength for subsequent processing steps. Then, a portion of the xerogels was thiolated using (3-mercaptopropyl)trimethoxysilane. Next, thiolated and unthiolated batches were ion-exchanged in AgNO 3 solutions where Ag + replaced Na + in the gel network on a near 1:1 molar basis. Subsamples of the Ag-exchanged xerogels were subjected to a reduction step in H 2 /Ar to convert Ag + to Ag 0 where the rest of the Ag-exchanged (Ag + ) were not reduced. X-ray diffraction, X-ray photoelectron spectroscopy, and transmission electron microscopy revealed nanoscale Ag 0 in the Ag + samples despite no active reduction where actively reduced samples had bimodal Ag 0 distribution of ~2-3 nm hexagonal and ~6-7 nm cubic crystallites. Synchrotron X-ray absorption spectroscopy was used to assess the oxidization states of Ag, S, and I within the different xerogel samples. The specific surface areas of the base xerogels decreased as subsequent treatments were performed on the as-made samples, albeit the decreases were smaller than aerogel equivalents of these samples from a previous study. All iodine-loaded Ag-based samples showed a mixture of β-AgI and γ-AgI. Comparisons of iodine-loading results with other Ag-based iodine sorbents show that the thiolated Ag 0 -xerogels in this work have one of the highest iodine-loading capacities (q e ) reported to date in saturated conditions with the thiolated Ag 0 -xerogel showing 522 mg iodine per g of the sorbent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine Capture with Metal-Functionalized Polyacrylonitrile Composite Beads Containing Ag 0 , Bi 0 , Cu 0 , or Sn 0 Particles

The capture of radioiodine from nuclear processes and the mitigation of environmental release are important topic areas of research. Some of the more commonly employed chemisorption-type iodine scavengers reported in the literature are based on metal-exchanged porous sorbents such as Ag-zeolites or metal-functionalized aerogels and xerogels. However, another option is to use zero-valent metals directly that have known high affinities for iodine gas [i.e., I2(g)]. In this study, fine metal particles of Ag0, Bi0, Cu0, and Sn0 were embedded in porous polyacrylonitrile (PAN) substrates at 75 mass% metal loadings within the form of ellipsoidal beads with maximum diameters of ~2–3 mm. These composite beads showed extremely high iodine loadings that are directly related to the metal particle loadings. The X-ray diffraction (XRD) analyses of Ag0, Bi0, Cu0, and Sn0 particles as well as metal-PAN composite beads reacted with iodine gas at 120 ± 1 °C showed phases of AgI, BiI3, CuI, and SnI4, respectively. For the Ag-PAN, Cu-PAN, and Sn-PAN beads, no other crystalline peaks were observed in XRD for unreacted metal or oxidized metals after 48 h in saturated I2(g) at 120 ± 1 °C, whereas unreacted metallic Bi0 was observed within the Bi-PAN composites. However, after a 72 h exposure at 120 ± 1 °C, both the Bi0 particles and the Bi-PAN composites showed full conversion from Bi0 to BiI3 with XRD. Comparisons between mass uptake data and X-ray absorption spectroscopy were used to better understand the phase distribution of the Bi phases present in the Bi-PAN+I composites. The iodine loadings (mg iodine per g sorbent, or qe) for these materials were 1120 (Ag-Particle), 1382 (Bi-Particle-72h), 1033 (Cu-Particle), 3000 (Sn-Particle), 753 (Ag-PAN), 1012 (Bi-PAN-72h), 1457 (Cu-PAN), and 1669 (Sn-PAN). It is possible that inexpensive sorbents such as these could be deployed to help limit or prevent release of radioiodine to the environment.

36 MATERIALS SCIENCE↗

Evaluating the Physisorption and Chemisorption of Iodine on Bismuth-Functionalized Carbon Foams

Bismuth-containing carbon materials have been shown to be highly promising sorbents for the capture of radioiodine. However, there is still a need to understand the effects of carbon and bismuth on the iodine sorption mechanism. In this study, we show the relationship between the physical and chemical sorption of iodine under different bismuth loading conditions. Here, highly porous and non-friable conductive carbon foams were prepared and bismuth was electrodeposited to provide strong iodine binding sites. For pure carbon foams, equal ratios of physisorbed and chemisorbed iodine-carbon phases were detected before desorption. As the concentration of bismuth increased, the chemisorption between bismuth and iodine dominated the total capture mechanism and physisorption was almost completely eliminated. Additionally, chemisorption of iodine depended upon the size and specific surface area of the bismuth particles present within the framework of the foam.

36 MATERIALS SCIENCE↗

An age-specific biokinetic model for iodine

This study reviews age-specific biokinetic data for iodine in humans and extends to pre-adult ages the baseline parameter values of the author’s previously published model for systemic iodine in adult humans. Compared with the ICRP’s current age-specific model for iodine introduced in Publication 56 (1989), the present model provides a more detailed description of the behavior of iodine in the human body; predicts greater cumulative (integrated) activity in the thyroid for short-lived isotopes of iodine; predicts similar cumulative activity in the thyroid for isotopes with half-time greater than a few hours; and, for most iodine isotopes, predicts much greater cumulative activity in salivary glands, stomach wall, liver, and kidneys.

61 RADIATION PROTECTION AND DOSIMETRY↗

A method to evaluate the dose increase in CT with iodinated contrast medium

Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols employ multiple scans at different circulatory phases after administration of contrast medium, such a method can be useful to evaluate the total dose to the patient, also in view of potential clinical protocol optimizations.

60 APPLIED LIFE SCIENCES↗

SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-12: The Effect of Iterative Reconstruction and CT Tube Voltage On Hounsfield Unit Values of Iodinated Contrast

Purpose: To investigate the effects of changing iterative reconstruction strength and tube voltage on Hounsfield Unit (HU) values of varying concentrations of Iodinated contrast medium in a phantom. Method: Iodinated contrast (Omnipaque 300, GE Healthcare, Princeton NJ) was diluted with distilled water to concentrations of 0.6, 0.9, 1.8, 3.6, 7.2, and 10.8 mg/mL of Iodine. The solutions were scanned in a patient equivalent water phantom on two MDCT scanners: VCT 64 slice (GE Medical Systems, Waukesha, WI) and an Aquilion One 320 slice scanner (Toshiba America Medical Systems, Tustin CA). The phantom was scanned at 80, 100, 120, 140 kV using 400, 255, 180, and 130 mAs, respectively, for the VCT scanner, and 80, 100, 120, and 135 kV using 400, 250, 200, and 150 mAs, respectively, on the Aquilion One. Images were reconstructed at 2.5 mm (VCT) and 0.5 mm (Aquilion One). The VCT images were reconstructed using Advanced Statistical Iterative Reconstruction (ASIR) at 6 different strengths: 0%, 20%, 40%, 60%, 80%, and 100%. Aquilion One images were reconstructed using Adaptive Iterative Dose Reduction (AIDR) at 4 strengths: no AIDR, Weak AIDR, Standard AIDR, and Strong AIDR. Regions of interest (ROIs) were drawn on the images to measure the HU values and standard deviations of the diluted contrast. Second order polynomials were used to fit the HU values as a function of Iodine concentration. Results: For both scanners, there was no significant effect of changing the iterative reconstruction strength. The polynomial fits yielded goodness-of-fit (R2) values averaging 0.997. Conclusion: Changing the strength of the iterative reconstruction has no significant effect on the HU values of Iodinated contrast in a tissue-equivalent phantom. Fit values of HU vs Iodine concentration are useful in quantitative imaging protocols such as the determination of cardiac output from time-density curves in the main pulmonary artery.

60 APPLIED LIFE SCIENCES↗

Microbial Influence on Iodine Speciation at the 200 West Hanford Site - 16549

A waste product from nuclear fission, the radioisotope iodine-129 ({sup 129}I) is of environmental concern due to its long half-life (∼16 million years), mobility, and hazardous potential to humans through bioaccumulation in the thyroid gland. The Hanford Site in Richland, Washington, contains two separate {sup 129}I contaminant plumes over 1,500 acres with concentrations of ∼3.5 pCi/L in groundwater samples, exceeding the federal drinking water standard of <1 pCi/L. Consequently, understanding the mechanisms and contributors to iodine speciation is important in order to develop appropriate remediation strategies for iodine in non-aqueous environments such as the vadose zone, the subsurface environment located directly above groundwater. A lack of current remedial techniques is due to the complexity of microbial influence and presence of dissolved organics that impact the transport and speciation of {sup 129}I. Although, iodide (I{sup -}) is thermodynamically favored in the geological support material, based on current pH and Eh ranges at the Hanford Site, groundwater sampling of monitoring wells within the 200 West Area have found the dominant species to be iodate (IO{sub 3}{sup -}) (70.6%) while organo-iodine (25.8%) and iodide (3.6%) were found in far lower quantities. Enrichments of Lower Ringgold sediment from the 200 West Hanford site allowed the isolation of microbial species metabolically involved in the speciation of iodine. Through a series of batch studies and spectrophotometric assays, isolates were found to couple nitrate (NO{sub 3}) reduction with iodate (IO{sub 3}), where iodate reduction was not observed in the absence of nitrate. Additionally, isolates able to oxidize iodide were also identified. Currently, analytical techniques are being developed to further understand the kinetics and enzymatic activity for both of these redox reactions. Ongoing research involves these isolates and their influence on iodine speciation in the presence of organics such as humic acid or lignocellulose. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Importance of Microbial Activity On Groundwater Iodate and Organo-Iodine Speciation and Mobility At Two DOE Sites

Iodine (I) occurs in multiple oxidation states in aquatic systems in the form of organic and inorganic species (iodide and iodate). This fact leads to complex biogeochemical cycling of Iodine and its long-lived isotope, 129 I, a major by-product of nuclear fission. Results from our newly developed, sensitive and rapid method for speciated isotopic ratios ( 129 I/ 127 I) via GC-MS, which compare favorably with Accelerator Mass Spectroscopy, demonstrate that the mobility of 129 I species greatly depends on the type of I species and its concentration, pH, and sediment redox state. At ambient concentrations (~10 7 M), I- and IO -3 are significantly retarded by sorption to mineral surfaces and covalent binding to aromatic moieties in natural organic matter (NOM), even when NOM is present at low concentrations such as occur at Hanford. At concentrations traditionally examined in sorption studies (≥ 10 -4 M), I- travels along with the water. Iodate removal can also occur through incorporation into CaCO 3 crystal lattice, e.g., at the Hanford Site. Removal of iodine from the groundwater through interaction with NOM is complicated by the release of mobile organo-I species, as was observed at SRS and Hanford. A small fraction of NOM that is bound to iodine can behave as a mobile organo-I source, a process that we were able to numerically simulate. Field and laboratory studies evaluating the cause for steady increases in 129 I concentrations (up to 1000 pCi L-1) emanating from radiological basins at SRS indicate that an increase of 0.7 pH units in groundwater over 17 years can account for the observed increased groundwater 129 I concentrations. Bacteria from a 129 I-contaminated aerobic aquifer at the F-area of SRS can accumulate I- at environmentally relevant concentrations (10 -7 M), and enzymatically oxidize I-, which together with microbially produced MnO 2 and superoxide or organic acids can significantly contribute to organo-iodine formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Iodine Immobilization Technologies: Cermets, Polycermets, and Polyhalmets

The work in this report documents the efforts conducted to assess the feasibility of some of the ideas documented in Pacific Northwest National Laboratory invention disclosure reports (IDRs) including: 1) Iodine capture in polyacrylonitrile (PAN)-containing composite sorbents (32451-E). In this work, the composites evaluated included Ag0, Bi0, Cu0, Bi2S3, and Cu2S embedded in PAN. 2) Metal iodide removal from these sorbents through dissolution in dimethyl sulfoxide (DMSO) (32729-E). In this work, PAN dissolution was evaluated for multiple types of sorbents including Ag-Pan, Bi-PAN, Cu-PAN, Bi2S3-PAN, and Cu2S-PAN. 3) Using metal-sulfide sorbents for iodine capture (32647-E). In this work, the composites evaluated under this IDR included Ag2S, Bi2S3, and Cu2S embedded in PAN. 4) Using low-melting metals to immobilize (encapsulate) iodine-loaded and polymer-containing sorbents into polymer-ceramic-metal (called polycermet) or polymer-halide-metal (called polyhalmet) composite waste forms (32625-E). In this work, the iodine-loaded PAN composites included AgI-PAN, BiI-PAN, and CuI-PAN. 5) Ceramic-metal composite waste form synthesis of polymer-containing materials using low-melting metals like bismuth, tin, or bismuth-tin alloys (32537-E). In this work, the metals evaluated included Bi, 58Bi-42Sn eutectic. 6) Cermets for immobilizing commercial sorbents loaded with radioiodine (32806-E). In this work, AgIX (iodine-loaded silver faujasite zeolite) was evaluated in cermet form.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Review of recent developments in iodine wasteform production

Radioiodine capture and immobilization is not only important to consider during the operation of reactors (i.e., I-131), during nuclear accidents (i.e., I-131 and I-129) or nuclear fuel reprocessing (i.e., I-131 and I-129), but also during disposal of nuclear wastes (i.e., I-129). Most disposal plans for I-129-containing waste forms (including spent nuclear fuel) propose to store them in underground repositories. Here, iodine can be highly mobile and, given its radiotoxicity, needs to be carefully managed to minimize long-term environmental impacts arising from disposal. Typically, any process that has been used to capture iodine from reprocessing or in a reactor is not suitable for direct disposal, rather conversion into a wasteform for disposal is required. The objectives of these materials are to use either chemical immobilization or physical encapsulation to reduce the leaching of iodine by groundwaters. Some of the more recent ideas have been to design capture materials that better align with disposal concepts, making the industrial processing requirements easier. Research on iodine capture materials and wasteforms has been extensive. This review will act as both an update on the state of the research since the last time it was comprehensively summarized, and an evaluation of the industrial techniques required to create the proposed iodine wasteforms in terms of resulting material chemistry and applicability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗