Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1.4 mSv was measured, respectively. Using kilovoltage or megavoltage radiation to obtain cone beam computed tomography scans led to an additional dose of 8-46 mSv. For treatment verification images performed once per week using double exposure technique, an additional effective dose of up to 18 mSv was measured. Conclusions: Daily setup imaging using kilovoltage planar images or TomoTherapy megavoltage fan beam CT imaging can be used as a standard procedure in clinical routine. Daily kilovoltage and megavoltage cone beam computed tomography setup imaging should be applied on an individual or indication based protocol. Depending on the imaging scheme applied, image-guided radiation therapy can be administered without increasing the dose outside of the treated volume compared to therapies without image guidance.

60 APPLIED LIFE SCIENCES↗

Calculation method using Clarkson integration for the physical dose at the center of the spread-out Bragg peak in carbon-ion radiotherapy

Purpose: In broad-beam carbon-ion radiotherapy performed using the heavy-ion medical accelerator in Chiba, the number of monitor units is determined by measuring the physical dose at the center of the spread-out Bragg peak (SOBP) for the treatment beam. The total measurement time increases as the number of treatment beams increases, which hinders the treatment of an increased number of patients. Hence, Kusano et al.[Jpn. J. Med. Phys. 23(Suppl. 2), 65-68 (2003)] proposed a method to calculate the physical dose at the center of the SOBP for a treatment beam. Based on a recent study, the authors here propose a more accurate calculation method.Methods: The authors measured the physical dose at the center of the SOBP while varying the circular field size and range-shifter thickness. The authors obtained the physical dose at the center of the SOBP for an irregularly shaped beam using Clarkson integration based on these measurements.Results: The difference between the calculated and measured physical doses at the center of the SOBP varied with a change in the central angle of the sector segment. The differences between the calculated and measured physical doses at the center of the SOBP were within {+-}1% for all irregularly shaped beams that were used to validate the calculation method.Conclusions: The accuracy of the proposed method depends on both the number of angular intervals used for Clarkson integration and the fineness of the basic data used for calculations: sampling numbers for the field size and thickness of the range shifter. If those parameters are properly chosen, the authors can obtain a calculated monitor unit number with high accuracy sufficient for clinical applications.

60 APPLIED LIFE SCIENCES↗

Optimizing Long-term Monitoring of Radiation Air Dose Rates - 19169

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (NPP) have been steadily decreasing over the past seven years since the accident in March 2011. After seven years, the radiation monitoring program is expected to transition from short-term emergency responses to long-term monitoring. The objectives of long-term monitoring are often different from early emergency responses, since extensive data accumulation has led to an understanding of contaminant distributions and mobility. The main long-term monitoring objectives are (1) to confirm system stability and the continuing reduction of contaminant and hazard levels, (2) to provide assurance for the public, (3) to accumulate the basic datasets for scientific knowledge and future preparation, and (4) to detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the sampling locations of radiation air dose-rate monitoring. Three steps are taken in order to determine sampling locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations across the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air dose rates across the domain. In the second step, we use a Gaussian mixture model to identify the representative locations in multiple environmental variables, such as elevation and land-cover types. In the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air dose rates across the domain. We use the integrated dose-rate map from the Bayesian geostatistical method as the reference map and distribute the sampling in such a way as to capture the heterogeneity of the reference map. Although we assume hypothetical sets of measurement locations to evaluate the performance of the methodology and algorithms, we have demonstrated this approach using real, spatially extensive datasets, including the integrated air-dose-rate map of 2016. Our results have shown that this approach allows us to add sampling locations in a systematic manner. Increasing the number of sampling locations can better capture the heterogeneity of dose rates, although the estimation error does not decrease further after a certain number of samples. We have also found that when there are restrictions such as pre-existing monitoring locations or the ones along roads, the spatial estimation becomes poor even with the same number of monitoring locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extension of PENELOPE to protons: Simulation of nuclear reactions and benchmark with Geant4

Purpose: Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4.Methods: PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac–Hartree–Fock–Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer–Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for {sup 1}H and ICRU 63 data for {sup 12}C, {sup 14}N, {sup 16}O, {sup 31}P, and {sup 40}Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth–dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth–dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone.Results: For simulations with EM collisions only, integral depth–dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth–dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth–dose distributions). The agreement is much better with FLUKA, with deviations within 3%/3 mm. When nuclear interactions were turned on, agreement (within 6% before the Bragg-peak) between PENH and Geant4 was consistent with uncertainties on nuclear models and cross sections, whatever the material simulated (water, muscle, or bone).Conclusions: A detailed and flexible description of nuclear reactions has been implemented in the PENH extension of PENELOPE to protons, which utilizes a mixed-simulation scheme for both elastic and inelastic EM collisions, analogous to the well-established algorithm for electrons/positrons. PENH is compatible with all current main programs that use PENELOPE as the MC engine. The nuclear model of PENH is realistic enough to give dose distributions in fair agreement with those computed by Geant4.

61 RADIATION PROTECTION AND DOSIMETRY↗

A multiscale Bayesian data integration approach for mapping air dose rates around the Fukushima Daiichi Nuclear Power Plant

This paper presents a multiscale data integration method to estimate the spatial distribution of air dose rates in the regional scale around the Fukushima Daiichi Nuclear Power Plant. We integrate various types of datasets, such as ground-based walk and car surveys, and airborne surveys, all of which have different scales, resolutions, spatial coverage, and accuracy. This method is based on geostatistics to represent spatial heterogeneous structures, and also on Bayesian hierarchical models to integrate multiscale, multi-type datasets in a consistent manner. The Bayesian method allows us to quantify the uncertainty in the estimates, and to provide the confidence intervals that are critical for robust decision-making. Although this approach is primarily data-driven, it has great flexibility to include mechanistic models for representing radiation transport or other complex correlations. Here, we demonstrate our approach using three types of datasets collected at the same time over Fukushima City in Japan: (1) coarse-resolution airborne surveys covering the entire area, (2) car surveys along major roads, and (3) walk surveys in multiple neighborhoods. Results show that the method can successfully integrate three types of datasets and create an integrated map (including the confidence intervals) of air dose rates over the domain in high resolution. Moreover, this study provides us with various insights into the characteristics of each dataset, as well as radiocaesium distribution. In particular, the urban areas show high heterogeneity in the contaminant distribution due to human activities as well as large discrepancy among different surveys due to such heterogeneity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Multiscale Bayesian Data Integration Approach for Mapping Air Dose Rates around the Fukushima Daiichi Nuclear Power Plant - 17166

This paper presents a multiscale data integration method to estimate the spatial distribution of air dose rates in the regional scale around the Fukushima Daiichi Nuclear Power Plant. We integrate various types of datasets, such as ground-based walk and car surveys, and airborne surveys, all of which have different scales, resolutions, spatial coverage, and accuracy. This method is based on geo-statistics to represent spatial heterogeneous structures, and also on Bayesian hierarchical models to integrate multiscale, multi-type datasets in a consistent manner. The Bayesian method allows us to quantify the uncertainty in the estimates, and to provide the confidence intervals that are critical for robust decision-making. Although this approach is primarily data-driven, it has great flexibility to include mechanistic models for representing radiation transport or other complex correlations. We demonstrate our approach using three types of datasets collected at the same time over Fukushima City, Japan: (1) coarse-resolution airborne surveys covering the entire area, (2) car surveys along major roads, and (3) walk surveys in multiple neighborhoods. Results show that the method can successfully integrate three types of datasets in a consistent manner, and create an integrated map (including the confidence intervals) of air dose rates over the domain in high resolution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of a Focused, Pulsed X-ray Beam for Total Ionizing Dose Testing of Bipolar Linear Integrated Circuits

Here, we demonstrate the utility of focused, pulsed X-rays for investigating localized total ionizing dose effects in bipolar analog integrated circuits. Using the LM139 comparator as a test vehicle, we show how the technique can be used to identify the sources of degradation as a result of irradiating different transistors of the device and how this impacts the input bias current, input offset voltage, and output voltage. The 2-D mapping of the sensitive regions of transistors is presented, where the results of localized irradiation impact the monitored operational parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing long-term monitoring of radiation air-dose rates after the Fukushima Daiichi Nuclear Power Plant

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (FDNPP) have been steadily decreasing over the past eight years since the release of radioactive elements in March 2011. Currently, the radiation monitoring program is expected to transition to long-term monitoring after most of the remediation activities are completed. The main long-term monitoring objectives are to (1) confirm the continuing reduction of contaminant and hazard levels, (2) provide assurance for the public, (3) accumulate the basic datasets for scientific knowledge and future preparation, and (4) detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the monitoring locations of radiation air dose-rate monitoring. Our approach consists of three steps in order to determine monitoring locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations that cover the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air-dose rates across the domain. Therefore, for the second step, we use a Gaussian mixture model to identify the representative locations among multiple environmental variables, such as elevation and land-cover types. For the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air-dose rates across the domain. Employing an integrated dose-rate map derived from Bayesian geostatistical methods as a reference map, we distribute the monitoring locations in such a way as to capture the heterogeneity of the reference map. Our results have shown that this approach allows us to select monitoring locations in a systematic manner such that the heterogeneity of air dose rates is captured by the minimal number of monitoring locations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-155: Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy

Purpose: Compare proton pencil beam scanning dose measurements to GATE/GEANT4 (GMC) and RayStation™ Monte Carlo (RMC) simulations. Methods: Proton pencil beam models of the IBA gantry at the Seattle Proton Therapy Center were developed in the GMC code system and a research build of the RMC. For RMC, a preliminary beam model that does not account for upstream halo was used. Depth dose and lateral profiles are compared for the RMC, GMC and a RayStation™ pencil beam dose (RPB) model for three spread out Bragg peaks (SOBPs) in homogenous water phantom. SOBP comparisons were also made among the three models for a phantom with a (i) 2 cm bone and a (ii) 0.5 cm titanium insert. Results: Measurements and GMC estimates of R80 range agree to within 1 mm, and the mean point-to-point dose difference is within 1.2% for all integrated depth dose (IDD) profiles. The dose differences at the peak are 1 to 2%. All of the simulated spot sigmas are within 0.15 mm of the measured values. For the three SOBPs considered, the maximum R80 deviation from measurement for GMC was −0.35 mm, RMC 0.5 mm, and RPB −0.1 mm. The minimum gamma pass using the 3%/3mm criterion for all the profiles was 94%. The dose comparison for heterogeneous inserts in low dose gradient regions showed dose differences greater than 10% at the distal edge of interface between RPB and GMC. The RMC showed improvement and agreed with GMC to within 7%. Conclusion: The RPB dosimetry show clinically significant differences (> 10%) from GMC and RMC estimates. The RMC algorithm is superior to the RPB dosimetry in heterogeneous media. We suspect modelling of the beam’s halo may be responsible for a portion of the remaining discrepancy and that RayStation will reduce this discrepancy as they finalize the release. Erik Traneus is employed as a Research Scientist at RaySearch Laboratories. The research build of the RayStation TPS used in the study was made available to the SCCA free of charge. RaySearch did not provide any monetary support other than a license to use the research build of the TPS.

60 APPLIED LIFE SCIENCES↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

Solar Modulation of Inner Trapped Belt Radiation Flux as a Function of Atmospheric Density

No simple algorithm seems to exist for calculating proton fluxes and lifetimes in the Earth's inner, trapped radiation belt throughout the solar cycle. Most models of the inner trapped belt in use depend upon AP8 which only describes the radiation environment at solar maximum and solar minimum in Cycle 20. One exception is NOAAPRO which incorporates flight data from the TIROS/NOAA polar orbiting spacecraft. The present study discloses yet another, simple formulation for approximating proton fluxes at any time in a given solar cycle, in particular between solar maximum and solar minimum. It is derived from AP8 using a regression algorithm technique from nuclear physics. From flux and its time integral fluence, one can then approximate dose rate and its time integral dose.

Lodhi, M. A. K.↗

Simplified Solar Modulation Model of Inner Trapped Belt Proton Flux As a Function of Atmospheric Density

No simple algorithm seems to exist for calculating proton fluxes and lifetimes in the Earth's inner, trapped radiation belt throughout the solar cycle. Most models of the inner trapped belt in use depend upon AP8 which only describes the radiation environment at solar maximum and solar minimum in Cycle 20. One exception is NOAAPRO which incorporates flight data from the TIROS/NOAA polar orbiting spacecraft. The present study discloses yet another, simple formulation for approximating proton fluxes at any time in a given solar cycle, in particular between solar maximum and solar minimum. It is derived from AP8 using a regression algorithm technique from nuclear physics. From flux and its time integral fluence, one can then approximate dose rate and its time integral dose. It has already been published in this journal that the absorbed dose rate, D, in the trapped belts exhibits a power law relationship, D = A(rho)(sup -n), where A is a constant, rho is the atmospheric density, and the index n is weakly dependent upon shielding. However, that method does not work for flux and fluence. Instead, we extend this idea by showing that the power law approximation for flux J is actually bivariant in energy E as well as density rho. The resulting relation is J(E,rho)approx.(sum of)A(E(sup n))rho(sup -n), with A itself a power law in E. This provides another method for calculating approximate proton flux and lifetime at any time in the solar cycle. These in turn can be used to predict the associated dose and dose rate.

Wilson, Thomas L.↗

Esophageal Cancer Dose Escalation Using a Simultaneous Integrated Boost Technique

Purpose: We previously showed that 75% of radiation therapy (RT) failures in patients with unresectable esophageal cancer are in the gross tumor volume (GTV). We performed a planning study to evaluate if a simultaneous integrated boost (SIB) technique could selectively deliver a boost dose of radiation to the GTV in patients with esophageal cancer. Methods and Materials: Treatment plans were generated using four different approaches (two-dimensional conformal radiotherapy [2D-CRT] to 50.4 Gy, 2D-CRT to 64.8 Gy, intensity-modulated RT [IMRT] to 50.4 Gy, and SIB-IMRT to 64.8 Gy) and optimized for 10 patients with distal esophageal cancer. All plans were constructed to deliver the target dose in 28 fractions using heterogeneity corrections. Isodose distributions were evaluated for target coverage and normal tissue exposure. Results: The 50.4 Gy IMRT plan was associated with significant reductions in mean cardiac, pulmonary, and hepatic doses relative to the 50.4 Gy 2D-CRT plan. The 64.8 Gy SIB-IMRT plan produced a 28% increase in GTV dose and comparable normal tissue doses as the 50.4 Gy IMRT plan; compared with the 50.4 Gy 2D-CRT plan, the 64.8 Gy SIB-IMRT produced significant dose reductions to all critical structures (heart, lung, liver, and spinal cord). Conclusions: The use of SIB-IMRT allowed us to selectively increase the dose to the GTV, the area at highest risk of failure, while simultaneously reducing the dose to the normal heart, lung, and liver. Clinical implications warrant systematic evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster - 31: Predicting IQ and hearing loss following radiotherapy in pediatric brain tumors: proton vs photon

Purpose: The increased sparing of normal tissues in intensity modulated proton therapy (IMPT) in pediatric brain tumor treatments should translate into improved neurocognitive outcomes. Models were used to estimate the intelligence quotient (IQ) and the risk of hearing loss 5 years post radiotherapy and to compare outcomes of proton against photon in pediatric brain tumors. Methods: Patients who had received intensity modulated radiotherapy (IMRT) were randomly selected from our retrospective database. The existing planning CT and contours were used to generate IMPT plans. The RBE-corrected dose was calculated for both IMPT and IMRT. For each patient, the IQ was estimated via a Monte Carlo technique, whereas the reported incidence of hearing loss as a function of cochlear dose was used to estimate the probability of occurrence. Results: The integrated brain dose was reduced in all IMPT plans, translating into a gain of 2 IQ points on average for protons for the whole cohort at 5 years post-treatment. In terms of specific diseases, the gains in IQ ranged from 0.8 points for medulloblastoma, to 2.7 points for craniopharyngioma. Hearing loss probability was evaluated on a per-ear-basis and was found to be systematically less for proton versus photon: overall 2.9% versus 7.2%. Conclusions: A method was developed to predict IQ and hearing outcomes in pediatric brain tumor patients on a case-by-case basis. A modest gain was systematically observed for proton in all patients. Given the uncertainties within the model used and our reinterpretation, these gains may be underestimated.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-04: Beam Modeling and Validation with Triple and Double Gaussian Dose Kernel for Spot Scanning Proton Beams

Purpose: To present the validity of our beam modeling with double and triple Gaussian dose kernels for spot scanning proton beams in Nagoya Proton Therapy Center. This study investigates the conformance between the measurements and calculation results in absolute dose with two types of beam kernel. Methods: A dose kernel is one of the important input data required for the treatment planning software. The dose kernel is the 3D dose distribution of an infinitesimal pencil beam of protons in water and consists of integral depth doses and lateral distributions. We have adopted double and triple Gaussian model as lateral distribution in order to take account of the large angle scattering due to nuclear reaction by fitting simulated inwater lateral dose profile for needle proton beam at various depths. The fitted parameters were interpolated as a function of depth in water and were stored as a separate look-up table for the each beam energy. The process of beam modeling is based on the method of MDACC [X.R.Zhu 2013]. Results: From the comparison results between the absolute doses calculated by double Gaussian model and those measured at the center of SOBP, the difference is increased up to 3.5% in the high-energy region because the large angle scattering due to nuclear reaction is not sufficiently considered at intermediate depths in the double Gaussian model. In case of employing triple Gaussian dose kernels, the measured absolute dose at the center of SOBP agrees with calculation within ±1% regardless of the SOBP width and maximum range. Conclusion: We have demonstrated the beam modeling results of dose distribution employing double and triple Gaussian dose kernel. Treatment planning system with the triple Gaussian dose kernel has been successfully verified and applied to the patient treatment with a spot scanning technique in Nagoya Proton Therapy Center.

07 ISOTOPE AND RADIATION SOURCES↗