Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydrogen Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solution excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing. HGR was measured for an actual-waste Tank 38 sample. The HGR measurements at 80, 90, 100, and 110 °C were 1.7×10 -7 , 4.7×10 -7 , 5.9×10 -7 , and 2.6×10 -6 ft 3 hr -1 gal -1 , respectively. The Limit of Detection and Limit of Quantification for the HGR measurements were 2.6×10-8 ft3 hr-1 gal-1 and 5.1×10 -8 ft 3 hr -1 gal -1 , respectively. HGR was measured in a high boiling point (HBP) simulant with major known SRS Tank Farm organic compounds. Testing used fresh organics and did not simulate the long-term exposure of these organics already experienced in the waste. Hence, testing is expected to provide high bias to the hydrogen generation rates. The final HGR measurements at 75, 100, and 140 °C were 6.2×10 -7 , 3.0×10 -6 , and 8.1×10 -5 ft 3 hr -1 gal -1 , respectively. Decreases in the HGR were noted at isothermal conditions with steady gas tracer concentration, which clouds development of a temperature dependent correlation for generation rate. While the simulant contains high concentrations of major SRS organics tested at high temperatures found in the 3H Evaporator, this limited data set may not fully bound values under all possible operating conditions. The HGR measurement apparatus was successfully employed to replicate hydrogen production rate experiments. Simulant without deliberately added organic carbon was found to contain approximately 200 mg/L of organic carbon from tramp organics in the reagents used to prepare the solution. The tests using such simulant generated hydrogen at rates consistent with, but somewhat lower than, those predicted at equivalent carbon and aluminum loadings by methods used at the Hanford Site. Prior to identifying the organic contaminants, potential sources of hydrogen in simulants without deliberately added organic carbon were examined. Testing determined that this hydrogen is not due to caustic reaction of organic materials of construction within the reaction vessel, electrolysis due to current leak, anode/cathode reactions, corrosion, or the method of heating employed in the experiment. During the HBP and Tank 38 testing, a peak was identified at a retention time greater than the retention time of the inert tracer of krypton. This peak has been identified as methane, and the data have been reexamined to obtain methane concentrations. For the HBP testing, methane concentration was constant at the highest temperature studied (140 °C) and higher than hydrogen. At the lower temperatures (100 and 75 °C), methane and hydrogen tracked closely, with methane concentration generally lower than hydrogen. For Tank 38, methane concentration was approximately 1/3 of the hydrogen concentration during testing (100 and 110 °C). At lower temperatures for Tank 38 testing (90, 80, and 27 °C), methane fell below the quantification range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Slow-Release Substrate Stimulates Groundwater Microbial Communities for Long-Term in Situ Cr(VI) Reduction

Cr(VI) is a widespread environmental contaminant that is highly toxic and soluble. Previous work indicated that a one-time amendment of polylactate hydrogen-release compound (HRC) reduced groundwater Cr(VI) concentrations for >3.5 years at a contaminated aquifer; however, microbial communities responsible for Cr(VI) reduction are poorly understood. In this work, we hypothesized that HRC amendment would significantly change the composition and structure of groundwater microbial communities, and that the abundance of key functional genes involved in HRC degradation and electron acceptor reduction would increase long-term in response to this slowly degrading complex substrate. To test these hypotheses, groundwater microbial communities were monitored after HRC amendment for >1 year using a comprehensive functional gene microarray. The results showed that the overall functional composition and structure of groundwater microbial communities underwent sequential shifts after HRC amendment. Particularly, the abundance of functional genes involved in acetate oxidation, denitrification, dissimilatory nitrate reduction, metal reduction, and sulfate reduction significantly increased. The overall community dynamics was significantly correlated with changes in groundwater concentrations of microbial biomass, acetate, NO 3 - , Cr(VI), Fe(II) and SO 4 2- . In conclusion, our results suggest that HRC amendment primarily stimulated key functional processes associated with HRC degradation and reduction of multiple electron acceptors in the aquifer toward long-term Cr(VI) reduction.

54 ENVIRONMENTAL SCIENCES↗

Complete genome sequence of Pseudomonas stutzeri strain RCH2 isolated from a Hexavalent Chromium [Cr(VI)] contaminated site

Abstract Hexavalent Chromium [Cr(VI)] is a widespread contaminant found in soil, sediment, and ground water in several DOE sites, including Hanford 100 H area. In order to stimulate microbially mediated reduction of Cr(VI) at this site, a poly-lactate hydrogen release compound was injected into the chromium contaminated aquifer. Targeted enrichment of dominant nitrate-reducing bacteria post injection resulted in the isolation of Pseudomonas stutzeri strain RCH2. P. stutzeri strain RCH2 was isolated using acetate as the electron donor and is a complete denitrifier. Experiments with anaerobic washed cell suspension of strain RCH2 revealed it could reduce Cr(VI) and Fe(III). The genome of strain RCH2 was sequenced using a combination of Illumina and 454 sequencing technologies and contained a circular chromosome of 4.6 Mb and three plasmids. Global genome comparisons of strain RCH2 with six other fully sequenced P. stutzeri strains revealed most genomic regions are conserved, however strain RCH2 has an additional 244 genes, some of which are involved in chemotaxis, Flp pilus biogenesis and pyruvate/2-oxogluturate complex formation.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

Mearini, G. T.↗

Silicon Carbide Micro-devices for Combustion Gas Sensing under Harsh Conditions

A sensor based on the wide bandgap semiconductor, silicon carbide (SiC), has been developed for the detection of combustion products in power plant environments. The sensor is a catalytic gate field effect device, Pt/SiO{sub 2}/SiC that can detect hydrogen-containing species in chemically reactive, high temperature (600 C) environments. We demonstrate that the device can be used as a hydrogen monitor in syngas applications of common interferants as well as sulfur and water vapor. These measurements were made in the Catalyst Screening Unit at NETL, Morgantown under atmospheric conditions. The sensor response to hydrogen gas at 350 C is 240 mV/decade, this is significantly higher than the device response to room temperature gas or that predicted from vacuum chamber studies. The enhanced catalytic activity of the platinum sensing film under energy plant operating conditions was investigated via AFM, x-ray diffraction, TEM and x-ray photoelectron spectroscopy. Our characterization indicated that exposure to high temperature gases significantly modifies the morphology of the Pt catalytic film and the Pt/SiO{sub 2} interfacial region, which we tentatively attribute to the enhanced hydrogen sensitivity of the sensing film. A model for the hydrogen/oxygen response of the SiC device under atmospheric conditions was developed. It is based on two independent phenomena: a chemically induced shift in the metal-semiconductor work function difference and the passivation/creation of charged states at the SiO{sub 2}-SiC interface. The optimum operating set point for the SiC sensor with respect to response time and long term reliability was determined to be close to mid-gap. Ultrahigh vacuum (UHV) techniques were used to investigate the effects of sulfur contamination on the Pt gate. Exposure to hydrogen sulfide, even in the presence of hydrogen or oxygen at partial pressures of 20-600 times greater than the H2S level, rapidly coated the gate with a monolayer of sulfur. Although hydrogen exposure could not remove the adsorbed sulfur, oxygen was effective at removing sulfur with no evidence of irreversible changes in device behavior. The role of oxygen in the functioning of the SiC sensors was also investigated. All of the results are consistent with oxygen acting through its surface reactions with hydrogen, including the need for oxygen to reset the device to a fully hydrogen-depleted state and competition between hydrogen oxidation and hydrogen diffusion to metal/oxide interface sites. A strong sensor response to the unsaturated linear hydrocarbon propene (C{sub 3}H{sub 6}) was observed.

08 HYDROGEN↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

A Reduced-Temperature Process for Preparing Atomically Clean Si(100) and SiGe(100) Surfaces with Vapor HF

Silicon processing techniques such as atomic precision advanced manufacturing (APAM) and epitaxial growth require surface preparations that activate oxide desorption (typically >1000 °C) and promote surface reconstruction toward atomically clean, flat, and ordered Si(100)-2 × 1. Here, in this study, we compare the aqueous and vapor phase cleaning of Si and Si/SiGe surfaces to prepare APAM-ready and epitaxy-ready surfaces at lower temperatures. Angle resolved X-ray photoelectron spectroscopy (ARXPS) and Fourier transform infrared (FTIR) spectroscopy indicate that vapor hydrogen fluoride (VHF) cleans dramatically reduce carbon surface contamination and allow the chemically prepared surface to reconstruct at lower temperatures, 600 °C for Si and 580 °C for a Si/Si 0.7 Ge 0.3 heterostructure, into an ordered atomic terrace structure indicated by scanning tunneling microscopy (STM). After thermal treatment and vacuum hydrogen termination, we demonstrate STM hydrogen desorption lithography (HDL) on VHF-treated Si samples, creating reactive zones that enable area-selective chemistry by using a thermal budget similar to CMOS process flows. We anticipate that these results will establish new pathways to integrate APAM with Si foundry processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Promotion of Hydrogen Release from Ammonia Borane with Mechanically Activated Hexagonal Boron Nitride

We present the activation of hydrogen release from AB by the presence of mechanically activated h–BN. Hydrogen is released at lower temperatures and the dehydrogenation is less exothermic than neat AB. This approach provides all the benefits of a light-weight scaffold without additional foreign contamination that might complicate AB recycling. Several beneficial effects that pertain to the hydrogen desorption properties of the mixtures of AB:nano-BN are notable, such as the decrease of hydrogen desorption temperature, the decrease in NH3 formation as well as the decrease of the exothermicity of hydrogen desorption with increasing the nano-BN concentration. The lower exothermicity of H2 release from AB in the mesoporous silica and the nano-BN may be due physical and chemical interactions between the PAB oligomers and the interface of the silica scaffold or BN support. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

08 HYDROGEN↗

Fluidized-Bed Gasification of Coal-Biomass-Plastics for Hydrogen Production

Coal is one of the most abundant fossil energy resources in the United States and in the world. The recoverable reserves in the United States are estimated to be about 252 billion tons – more than 350 years of supply at current rates of usage. However, the share of coal in total primary energy consumption in the US has been declining over the years. The decline of coal is mainly attributed to cheap natural gas and precipitous declines in the cost of electricity production from renewable technologies such as wind and solar. Coal can potentially be used if it is coupled with carbon-neutral feedstock such as biomass-agricultural residues, forest biomass, and forest residues. Co-gasification of coal and biomass can become a negative carbon emission technology if the carbon dioxide (CO 2 ) is captured and sequestered. Although the biomass gasification process has a lot of similarities to coal gasification, the large-scale adaptation of power production sourced from biomass has not come to fruition. The main reason is that the power production from biomass is still expensive when compared with natural gas or coal power technologies. To address the feedstock cost, one approach is to use low-cost feedstocks, such as municipal solid wastes (MSW) or plastics, for gasification. Gasification involves the partial oxidation of coal and/or biomass feedstocks to produce a combustible fuel called synthesis gas (syngas) which is composed of carbon monoxide (CO), hydrogen (H 2 ), CO 2 , methane (CH 4 ), nitrogen (N 2 ), water (H 2 O), and other compounds that might be considered as contaminants. Raw syngas from gasification must go through multiple steps to produce high-purity hydrogen. The specific steps depend upon the quality (gas composition, contaminants, and their concentration) and condition (pressure and temperature) of syngas. The long-term goal of the project was to utilize coal and plastics together with biomass to produce energy and fuels using a gasification platform while reducing greenhouse gas emissions. The main objective of this research was to examine gasification performance in a laboratory-scale fluidized-bed gasifier for hydrogen production. The specific objectives of the research were to: (i) study coal-plastic-biomass mixture flowability for consistent feeding in the gasifier; (ii) understand the gasification behavior of the mixture in steam and oxygen environments; (iii) perform thermal property characterization of ash and slag from the mixture feedstock and refractory-ash interface of the mixture under gasification conditions; and (iv) develop process models to determine the technology needed for syngas cleanup and contaminants. The study found that there was no apparent segregation when biomass, coal, and waste plastics were mixed together during feeding. Although there were differences in hydrogen production when individual feedstock were fed, the hydrogen concentration remained almost constant with various blends. Therefore, blending waste plastics with biomass and coal, which are all abundant, is a better approach for energy production. Results of the techno-economic analysis suggested that integration of advanced gasification (GTI’s R-GAS™) and syngas cleanup and conditioning technologies (RTI’s WDP and AFWGS) for clean hydrogen production resulted in substantial benefits, including significant capital cost and operating cost reductions. Advanced technologies resulted in 16% reduction in the hydrogen production cost (COH) from 2.94 $\$$/kg to 2.47 $\$$/g, with further scope for optimization and cost reduction. These advanced technologies also result in lower emissions, and improved energy efficiency.

01 COAL, LIGNITE, AND PEAT↗

First-principles studies of H 2 S adsorption and dissociation on metal surfaces

Density functional theory calculations were employed to investigate the molecular and dissociative adsorption of H 2 S On the closed packed surfaces of a number of important noble metals (Ag(111), Au(111) and Cu(111)) and transition metals (Ir(111), Ni(111), Pd(111) and Pt(111)). Energy Minima Corresponding to adsorbed states were identified with H 2 S binding preferentially at the top sites. The adsorption of other S moieties (SH and S) was also examined. SH and S were found to prefer bridge sites and hollow sites, respectively. The binding of H 2 S and its Scontaining dissociated species is stronger on the transition metals. The elementary reactions of abstraction of H from H 2 S to form a surface SH intermediate and abstraction of H from SH to form a surface S intermediate as model pathways for the dissociation of H 2 S were examined. Our results suggest that H 2 S decomposition on the aforementioned transition metal Surfaces is more facile, both thermodynamically and kinetically.

36 MATERIALS SCIENCE↗

Near Quantitative Removal of Selenate and Sulfate Anions from Wastewaters by Cocrystallization with Chelating Hydrogen-Bonding Guanidinium Ligands

Selenium (Se) has become an environmental contaminant of aquatic ecosystems as a result of human activities, particularly mining, fossil fuel combustion, and agricultural activities. By leveraging the high sulfate concentrations relative to Se oxyanions (i.e., SeO n 2– , n = 3, 4) present in some wastewaters, we have developed an efficient approach to Se-oxyanion removal by cocrystallization with bisiminoguanidinium (BIG) ligands that form crystalline sulfate/selenate solid solutions. The crystallization of the sulfate, selenate and selenite, oxyanions and of sulfate/selenate mixtures with five candidate BIG ligands are reported along with the thermodynamics of crystallization and aqueous solubilities. Oxyanion removal experiments with the top two performing candidate ligands show a near quantitative removal (>99%) of sulfate or selenate from solution. When both sulfate and selenate are present, there is near quantitative removal (>99%) of selenate, down to sub-ppb Se levels, with no discrimination between the two oxyanions during cocrystallization. Reducing the selenate concentrations by 3 orders of magnitude or more relative to sulfate, as found in many wastewaters, led to no measurable loss in Se removal efficiencies. This work offers a simple and effective alternative to selective separation of trace amounts of highly toxic selenate oxyanions from wastewaters, to meet stringent regulatory discharge limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Use of Vaporous Hydrogen Peroxide for Building Decontamination Final Report CRADA No. TC-2053-02

This was a collaborative effort between LLNL and STE to investigate the use of vaporized hydrogen peroxide (VHP®) to decontaminate spore-contaminated heating, ventilation, and cooling (HV AC) systems in a trailer sized room. LLNL's effort under this CRADA was funded by DOE's Chemical and Biological National Security Program (CBNP), which later became part of Department of Homeland Security in 2004.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved melt model for power flow

Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.

43 PARTICLE ACCELERATORS↗

continuum and emission lines in eta Lyrae

Integral photometric characteristics of beta Lyrae were redetermined using its brightest visual companion, the star HD 174664. It was attempted to separate the fluxes coming from the two components. The flux distributions are badly contaminated by the radiation of the circumstellar hydrogen. Peculiarities seem to be present in both components; in particular, the secondary star cannot be represented by an atmosphere with a unique effective temperature, and best represented by a thick disk.

Plavec, M. J.↗

Evidence for processed material in the atmospheres of Large Magellanic Cloud B supergiants

We present a high-dispersion study of the optical spectra of 11 LMC B-type supergiants. These stars had been shown previously to have a wide range in nitrogen absorption line strengths, despite having very similar temperatures and luminosities. The current study shows that the relatively rare nitrogen-weak stars also have weaker photospheric helium lines and stronger photospheric oxygen lines than the more spectroscopically typical supergiants. This pattern suggests that the vast majority of LMC B-type supergiants have had their surfaces contaminated by material from their original hydrogen-burning cores - with a resultant enhancement of surface nitrogen and helium and a depletion in oxygen - while the spectroscopically nitrogen-weak stars are more likely to have retained their main-sequence surface abundances.

Fitzpatrick, Edward L.↗