Thermal-Hydraulic Investigations of a Horizontal Dry Cask Simulator.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Idealized large-eddy simulation (LES) is a basic tool for studying three-dimensional turbulence in the planetary boundary layer. LES is capable of providing benchmark solutions for parameterization development efforts. However, real small-scale atmospheric flows develop in heterogeneous and transient environments with locally varying vertical motions inherent to open multiscale interactive dynamical systems. These variations are often too subtle to detect them by state-of-the-art remote and in situ measurements, and are typically excluded from idealized simulations. The present study addresses the impact of weak [i.e., O(10-6) s-1] short-lived low-level large-scale convergence/divergence perturbations on continental shallow convection. The results show a strong response of shallow nonprecipitating convection to the applied weak large-scale dynamical forcing. Evolutions of CAPE, mean liquid water path, and cloud-top heights are significantly affected by the imposed convergence/divergence. In contrast, evolving cloud-base properties, such as the area coverage and mass flux, are only weakly affected. To contrast those impacts with microphysical sensitivity, the baseline simulations are perturbed assuming different observationally based cloud droplet number concentrations and thus different rainfall. For the tested range of microphysical perturbations, the imposed convergence/divergence provides significantly larger impact than changes in the cloud microphysics. Simulation results presented here provide a stringent test for convection parameterizations, especially important for large-scale models progressing toward resolving some nonhydrostatic effects.
Transient, synoptic-scale vortices produce a large fraction of total rainfall in most monsoon regions and are often associated with extreme precipitation. However, the mechanism of their amplification remains a topic of active research. For monsoon depressions, which are the most prominent synoptic-scale vortex in the Asian–Australian monsoon, recent work has suggested that meridional gradients in zonal wind in the vortex environment may produce growth through barotropic instability, while meridional gradients in environmental humidity have also been proposed to cause amplification through coupling with precipitating convection. Here, a two-dimensional shallow water model on a sphere with parameterized precipitation is used to examine the relative role played by these two environmental gradients. By systematically varying the meridional moisture gradient and meridional wind shear for both weak, quasi-linear waves and finite-amplitude isolated vortices, we show that rotational winds in the initial vortex are amplified most strongly by meridional shear of the environmental zonal wind, while vortex precipitation rates are most sensitive to environmental moisture gradients. The growth rate in the presence of both gradients is less than the sum of growth rates in the presence of isolated gradients, as the phase relation between moisture and vorticity anomalies becomes distorted with increasing shear. In conclusion, these results suggest that background meridional gradients in both zonal wind and environmental humidity can contribute to the amplification of vortices to monsoon depression strength, but with some degree of decoupling of the dry rotational flow and the moist convection.
Monthlong simulations targeting four Madden–Julian oscillation events made with several global model configurations are verified against observations to assess the roles of grid spacing and convective parameterization on the representation of tropical convection and midlatitude forecast skill. Specifically, the performance of a global convection-permitting model (CPM) configuration with a uniform 3-km mesh is compared to that of a global 15-km mesh with and without convective parameterization, and of a variable-resolution “channel” simulation using 3-km grid spacing only in the tropics with a scale-aware convection scheme. It is shown that global 3-km simulations produce realistic tropical precipitation statistics, except for an overall wet bias and delayed diurnal cycle. The channel simulation performs similarly, although with an unrealistically higher frequency of heavy rain. The 15-km simulations with and without cumulus schemes produce too much light and heavy tropical precipitation, respectively. Without convection parameterization, the 15-km global model produces unrealistically abundant, short-lived, and intense convection throughout the tropics. Only the global CPM configuration is able to capture eastward-propagating Madden–Julian oscillation events, and the 15-km runs favor stationary or westward-propagating convection organized at the planetary scale. The global 3-km CPM exhibits the highest extratropical forecast skill aloft and at the surface, particularly during week 3 of each hindcast. Although more cases are needed to confirm these results, this study highlights many potential benefits of using global CPMs for subseasonal forecasting. Furthermore, results show that alternatives to global convection-permitting resolution—using coarser or spatially variable resolution—feature compromises that may reduce their predictive performance.
Data used in JGR Solid Earth manuscript.
The best performance of niobium SRF accelerating cavities is obtained with surfaces smoothed with electropolishing chemical finishing. Jefferson Lab has recently specified, procured, installed, and commissioned a new versatile production electropolishing (EP) tool. Experience with EP research and operations at JLab as well as vendor interactions and experience guided development of the system specification. Detailed design and fabrication was awarded by contract to Semiconductor Process Equipment Corporation (SPEC). The delivered system was integrated into the JLab chemroom infrastructure and commissioned in 2020. The new EP tool provides much improved heat exchange from the circulating H₂SO₄/HF electrolyte and also the cavity via variable temperature external cooling water flow, resulting in quite uniform cavity wall temperature control and thus improved removal uniformity. With the JLab infrastructure, stabilized process temperature as low as 5 C is available. We describe the system and illustrate operational modes in this contribution.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The Inner Triplet (IT) quadrupoles are the magnetic system for reaching low beta functions around the Interaction Point (IP). The triplet is made of three optical elements: Q1, Q2, and Q3. The upgrade of the Inner Triplets in the high luminosity insertions is the cornerstone of the LHC upgrade. The decision for HL-LHC heavily relies on the success of the advanced Nb 3 Sn technology that provides access to magnetic fields well beyond 9 T, allowing the maximization of the aperture of the IT quadrupoles. A 15-year-long study led by the DOE in the US under the auspices of the U.S. LARP program, and lately by other EU programs, has shown the feasibility of Nb 3 Sn accelerator magnets. The HL-LHC is expected to be the first application of accelerator-quality Nb 3 Sn magnet technology in an operating particle accelerator.
The Muon Campus g-2 experiment requires stable helium supply at 5 K to the superconducting magnet. After a short period of operations, the pressure drop across the magnet’s flow supply valve increases due to impurities, resulting in reduced excess capacity concurrently with drop in refrigerator expander efficiency. This requires periodic powering down of the magnet to allow for helium valve “flush” to remove accumulated contamination at the valve as well as warming up the refrigerator expander above 80 K to release contamination. A “mobile” purifier is used for this periodic process but only at 10% of total refrigerator flow such that the purification process is extended. After long duration of running, this purification procedure is required almost every two weeks to restore proper liquid helium supply to the magnet. This shows requirement for full flow purifier which can purify impurities from entire Muon Campus refrigerator system and mitigate existing impurities issue and associated experiment downtime.
Abstract not provided.
Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.
In late 2023 and early 2024, testing was done at the Weapons Engineering Tritium Facility (WETF) rooftop exhaust duct to verify that the stack sample location was in compliance with the ANSI standard for stack sampling, ANSI N13.1-1999. This ANSI standard is called out by the Clean Air Act rules for airborne radionuclide emissions from DOE facilities, 40 CFR 61 Subpart H. This sample location is designated 16020504, indicating Technical Area 16, Building 0205. The rooftop duct formerly discharged to Exhaust Stack 04, but in 2007 it was re-routed to exhaust out Building 0450, Exhaust Stack 05. For continuity, we have kept the 16020504 designation to represent this duct sample location.