Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Probing the effect of magnetic field on charge order in the quasi-two-dimensional Mott insulator κ - (ET) 2 Hg(SCN) 2 Cl

Molecular-based quasi-two-dimensional charge-ordered Mott insulators can possess both spin S = 1/2 and an electric dipole degree of freedom residing on each (BEDT - TTF) 2 lattice site. There exists a theoretical proposal for a magnetoelectric effect in such a material, which can manifest itself as a sensitivity of charge distribution on (BEDT - TTF) 2 dimers to the magnetic field. Here in this work, we used Raman scattering spectroscopy in the magnetic field up to 31 T applied perpendicular to the two-dimensional triangular lattice planes to probe a magnetoelectric effect in $\kappa$ - (ET) 2 H g (SCN) 2 Cl. This is a model compound, which shows charge order and antiferromagnetic correlations at temperatures below 30 K. We discuss possible reasons for the absence of an observable magnetoelectric effect in the probed temperature and magnetic field ranges.

36 MATERIALS SCIENCE↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Schiff Moment of 129 Xe and 199 Hg [Slides]

Using Chicoma in 2025, we advanced DFT-based calculations needed to connect fundamental T violating interactions to measurable Schiff moments in heavy nuclei. We implemented DFT for polarized odd nuclear systems, a first step toward treating the time-reversal-breaking mean fields required for Schiff moment calculations. As a validation test, we computed polarizabilities using a perturbation with the dipole operator (see figure to the right) for the odd systems shown in Table 1; while no odd-system effect is expected for polarizabilities, this capability is essential for Schiff moments. Initial mean-field solutions for 129 Xe Schiff moment calculations were also generated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗