Method and system for a gas tube-based current source high voltage direct current transmission system

A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ferroelectric opening switch

A ferroelectric opening switch is enabled by controlled polarization switching via nucleation in a ferroelectric material, such as BaTiO3, Pb(Zr,Ti)O3, LiNbO3, LiTaO3, or variants thereof. For example, nucleation sites can be provided by mechanical seeding, grain boundaries, or optical illumination. The invention can be used as an opening switch in large scale pulsed-power systems. However, the switch can also be used in compact pulsed-power systems (e.g., as drivers for high power microwave systems), as passive fault limiters for high voltage dc (HVDC) systems, and/or in other high power applications.

30 DIRECT ENERGY CONVERSION↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

The oversized role of transmission in renewable integration and national security

This is a presentation for the June 1 Road to Resilience Week webinar focused on "Transmission: A National Security and Energy Resilience Imperative." Today’s electric grid cannot adequately address the national security threats it faces. Interregional HVDC transmission is a core solution to address these vulnerabilities. This webinar will focus on why we need to think about transmission as not only key for the clean energy transformation but as essential to strengthening the resilience of our electric grid. Emma Stewart, in her first speaking engagement as Chief Power Grid Scientist and Research Strategist for Idaho National Laboratory, will provide her perspective on how transmission plays an oversized role in enhancing national security and unlocking clean energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interregional Transmission Operational Coordination

This presentation will discuss challenges and opportunities on interregional coordination in the areas of interchange transaction, congestion management, reserve sharing and deliverability across multi-stage operational processes. It will then provide an overview of the interregional transmission operational coordination (IRTOC) project that currently focuses on congestion management, including Inter-regional transmission coordination in real time operations and operational planning, HVDC optimization (intra- and interregional), ancillary service deliverability (intra- and interregional). In addition, it will discuss the Sienna-Decomposition tool development to systematically study interregional coordination methods.

congestion management↗

Influence of the airflow speed along transmission lines on the DC corona discharge loss, using finite element approach

Corona discharge is of great interest from the physical point of view and due to its numerous practical applications in industry and especially one of the most important sources of loss in the high voltage transmission lines. This paper provides guidelines for the amount of electric loss caused by corona phenomenon occurred around a DC high voltage wire placed between two flat plates and influence of wind speed rate on the amount of corona loss using COMSOL Multiphysics. So electric potential distribution patterns and charge density diffusion around the wire are studied in this article.

42 ENGINEERING↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Automated qualification and analysis of protective spark gaps for DC accelerators

Protective spark gaps are used in the high voltage multiplier column of a 3 MeV DC Accelerator to prevent excessive voltage build-ups. Precise gap of 5 mm is maintained between the electrodes in these spark gaps for obtaining 120 kV± 5 kV in 6 kg/cm{sup 2} SF{sub 6} environment which is the dielectric medium. There are 74 such spark gaps used in the multiplier. Each spark gap has to be qualified for electrical performance before fitting in the accelerator to ensure reliable operation. As the breakdown voltage stabilizes after a large number of sparks between the electrodes, the qualification process becomes time consuming and cumbersome. For qualifying large number of spark gaps an automatic breakdown analysis setup has been developed. This setup operates in air, a dielectric medium. The setup consists of a flyback topology based high voltage power supply with maximum rating of 25 kV. This setup works in conjunction with spark detection and automated shutdown circuit. The breakdown voltage is sensed using a peak detector circuit. The voltage breakdown data is recorded and statistical distribution of the breakdown voltage has been analyzed. This paper describes details of the diagnostics and the spark gap qualification process based on the experimental data. (author)

43 PARTICLE ACCELERATORS↗

Optical signatures of discharges in parallel coupled DC accelerator

Parallel coupled voltage multiplier based accelerator topologies offer advantages of better regulation and ripple compared to their series coupled counterparts for Industrial electron beam accelerators. During conditioning and operation these systems undergoes various types of electrical discharges. The discharge can be a direct spark over from the high voltage terminal to ground through SF{sub 6} insulation, vacuum breakdown in the accelerating tube maintained in the order of 10{sup -7} mbar pressure, or local discharge between corona guards which are used to couple RF power to the multiplier. There could be discharges in between dynodes of the accelerating tube. As the inter electrode discharges do not reflect in load current, detection of these conditions becomes very difficult. Optical discharge detection methods can be used effectively in this situation. Photo multiplier based optical discharge detection has been deployed in a 3 MeV DC accelerator. Characteristics of the optical signal received during conditioning phase have been presented in this paper. (author)

43 PARTICLE ACCELERATORS↗

Doubly Fed Induction Generator in an Offshore Wind Power Plant Operated at Rated V/Hz: Preprint

This paper introduces the concept of constant Volt/Hz operation of offshore wind power plants. The deployment of offshore WPPs requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cables, there is a need to use High-Voltage Direct Current transmission, which is economical for transmission distances longer than 50 kilometers. In theconcept presented here, the onshore substation is operated at 60 Hz synced with the grid, and the offshore substation is operated at variable frequency and voltage, thus allowing the WPP to be operated at constant Volt/Hz.

17 WIND ENERGY↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Imbalance Mechanism and Balanced Control of Capacitor Voltage for a Hybrid Modular Multilevel Converter

Due to different charging and discharging characteristics of full-bridge submodules and half-bridge submodules in hybrid modular multilevel converters (MMC), capacitor voltage imbalance will occur under boosted ac voltage or reduced dc voltage conditions. To address this issue, the mechanism of capacitor voltage imbalance is carefully studied, with three main factors-modulation index, power angle, and hybridization ratio-summarized and their effect on capacitor voltage imbalance analyzed. Further, a control strategy based on fundamental frequency reactive circulating current injection is proposed to keep the capacitor voltage balanced in the hybrid MMC. The amplitude and phase angle of the injected circulating current are calculated and their influence on the energy fluctuation in the submodules' capacitors and the semiconductors' current stress is explored. Lastly, experimental results under boosted ac voltage and reduced dc voltage conditions demonstrate the feasibility and validity of the proposed scheme.

42 ENGINEERING↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnections Seam Study [Slides]

The Interconnections Seam Study analyzes the grid impacts of increased connections between the Eastern and Western Interconnections in North America.

17 WIND ENERGY↗

The Future Role of Hydropower in the Northeastern United States: May 2020-May 2022

This paper explores the future role of hydropower in the Northeastern US and beyond. The intent is to provide experience-based insights into how hydropower can best support the reliable and economic evolution of the New England power system and, more broadly, all US grids. Many of the challenges facing New England are driven by the potential integration of 10s of GWs of variable energy resources. Hydro can assist in remediating several issues, and the paper explores how Hydro might hit above its weight in a future low carbon New England system. Hydro can assist in handling periods of over generation, reduce the risk of curtailment of zero carbon resources, improve market efficiency, and provide valuable essential reliability services.

13 HYDRO ENERGY↗