Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

OpenStudio®-MCP [SWR-26-035]

OpenStudio®-MCP is a Model Context Protocol (MCP) server that lets AI assistants perform building energy modeling through natural language. Rather than requiring users to learn the OpenStudio® SDK, EnergyPlus® scripting, or Ruby/Python automation, the server translates conversational requests into sequences of tool calls that create models, design HVAC systems, run simulations, and extract results — all within a single chat session. The server's 124 tools are organized into a skills architecture where each skill encapsulates a domain of building energy modeling (envelope, HVAC, loads, weather, simulation, results) behind typed, LLM-friendly interfaces. High-leverage operations like applying ASHRAE 90.1 baseline systems or generating standards-compliant typical buildings are exposed as single tool calls that internally wire dozens of OpenStudio® objects. Bundled measures from ComStock™ and Openstudio® -common-measures-gem are wrapped with dedicated tools and typed arguments rather than exposed through a generic measure interface, so AI models get consistent, error-resistant recipes without needing to discover measure arguments at runtime. A key design decision is structured results extraction: six SQL-based tools return surgical ~300–1,000 token responses (end-use breakdowns, envelope summaries, HVAC sizing, timeseries data) instead of requiring the AI to parse ~100K-token raw HTML reports, making iterative design exploration practical within context window limits. The codebase is designed as a reference implementation — explicit, well-commented, and modular — so that other simulation engines (EnergyPlus® standalone, TRNSYS, DOE-2) can use it as a template for building their own MCP servers.

Ball, Brian [National Laboratory of the Rockies (N↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Bringing Fault Detection and Diagnostics (FDD) Tools into the Mainstream: Retro Commissioning and Continuous Commissioning of HVAC and Refrigeration Systems

HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Park Service Bus Electrification Study: 2020 Report

This report summarizes important considerations for implementing BEBs in the three national park fleets, detailing information about current buses at each fleet, electric bus demonstration vehicles, as well as performance evaluations of BEBs in Zion, Bryce, and Yosemite. Results include in-use data collection results reporting metrics such as average bus speed, energy usage per trip, and daily distance traveled, as well as effects of high heating, ventilation, and air conditioning (HVAC) system use to both heat and cool the buses, emissions estimations before and after use of electric buses, operating costs, electric vehicle infrastructure, maintenance, and bus driver user experience survey information. Analysis results from this project will help the NPS understand how BEBs and future expansion of BEBs could assist in meeting their bottom line and operational goals and assist NPS in choosing appropriate locations for future BEB deployments.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity Analysis of an Electrospray Dehumidification System

Electrically enhanced condensation achieved by an electrospray system can enhance dehumidification in HVAC applications if successfully scaled up. The first step towards scale-up is identifying critical design and operating parameters that significantly impact dehumidification for the electrospray system. Sensitivity analysis is one approach for identifying critical parameters. This paper presents a methodology that can efficiently perform quantitative sensitivity analysis on a computationally expensive high fidelity simulation model, which is a computational fluid dynamics (CFD) model of the electrospray system. The methodology employs surrogate modeling and Sobol sensitivity analysis. We estimate the main and total effect Sobol sensitivity indices of four operating parameters of the electrospray system. The results reveal that the most important parameter is the size of the sprayed droplets, followed by the volumetric flow rate of the bulk air and injected water in the system. The water injection velocity of the spray was found to have little to no impact on dehumidification.

Young, David↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate: Preprint

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Scheduling Framework using SP-ADMM for Residential Demand Response with Weather and Consumer Uncertainties

This paper presents a comprehensive scheduling framework for residential demand response (DR) programs considering both the day-ahead and real-time electricity markets. In the first stage, residential customers determine the operating status of their responsive devices such as heating, ventilation, and air conditioning (HVAC) systems and electric water heaters (EWHs), while the distribution system operator (DSO) computes the amount of electricity to be purchased in the day-ahead electricity market. In the second stage, the DSO purchases insufficient (or sells surplus) electricity in the real-time electricity market to maintain the supply-demand balance. Due to its computational complexity and data privacy issues, the proposed model cannot be directly solved in a centralized manner, especially with a large number of uncertain scenarios. Therefore, this paper proposes a combination of stochastic programming (SP) and the alternating direction method of multipliers (ADMM) algorithm, called SP-ADMM, to decompose the original model and then solve each sub-problem in a distributed manner while considering multiple uncertain scenarios. The simulation study is performed on the IEEE 33-bus system including 121 residential houses. Here, the results demonstrate the effectiveness of the proposed approach for large-scale residential DR applications under weather and consumer uncertainties.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Layered Thermal Insulation Systems for Industrial and Commercial Applications

From the high performance arena of cryogenic equipment, several different layered thermal insulation systems have been developed for industrial and commercial applications. In addition to the proven areas in cold-work applications for piping and tanks, the new Layered Composite Insulation for Extreme Environments (LCX) has potential for broader industrial use as well as for commercial applications. The LCX technology provides a unique combination of thermal, mechanical, and weathering performance capability that is both cost-effective and enabling. Industry applications may include, for example, liquid nitrogen (LN2) systems for food processing, liquefied natural gas (LNG) systems for transportation or power, and chilled water cooling facilities. Example commercial applications may include commercial residential building construction, hot water piping, HVAC systems, refrigerated trucks, cold chain shipping containers, and a various consumer products. The LCX system is highly tailorable to the end-use application and can be pre-fabricated or field assembled as needed. Product forms of LCX include rigid sheets, semi-flexible sheets, cylindrical clam-shells, removable covers, or flexible strips for wrapping. With increasing system control and reliability requirements as well as demands for higher energy efficiencies, thermal insulation in harsh environments is a growing challenge. The LCX technology grew out of solving problems in the insulation of mechanically complex cryogenic systems that must operate in outdoor, humid conditions. Insulation for cold work includes equipment for everything from liquid helium to chilled water. And in the middle are systems for LNG, LN2, liquid oxygen (LO2), liquid hydrogen (LH2) that must operate in the ambient environment. Different LCX systems have been demonstrated for sub-ambient conditions but are capable of moderately high temperature applications as well.

thermal conductivity↗