Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOUSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Isolation and characterization of a respirable particle fraction from residential house-dust

Highlights: • House dust is an important environmental matrix to monitor. • A method for the isolation of dust particles in the respirable size range was developed. • The study presents a comprehensive characterization of house dust in the respirable size range. • This method may be a valuable for risk assessment following an inhalation exposure to house dust. Indoor air pollution has caused increasing concern in recent years. As we spend most of our lives indoors, it is crucial to understand the health effects caused by indoor air pollution. Household dust serve as good proxy for accessing indoor air pollution, especially smaller dust particles that can pass into the lungs are of interest. In this study we present an efficient method for the isolation of dust particles in the respirable size range. The respirable fraction was recovered from vacuum cleaner bags, separated by stepwise sieving, followed by characterization for size, morphology, surface area, organic content and elemental composition. The respirable fraction was obtained in a yield of 0.6% with a specific surface area of 2.5 m{sup 2}/g and a Mass Median Aerodynamic Diameter of 3.73 ± 0.15 µm. Aluminum and zink were the dominating metals measured in the dust, whereas the major mineral components were found to be silicon dioxide and calcium carbonate. The fraction of organic matter in the dust was measured to be 69 ± 1%. The organic matrix contained bacterial and fungi and a presence of skin fragments. We present here an efficient and fast method for the isolation of dust particles in the respirable size range. That is of considerable value due to the need for large quantities of respirable particle fractions to conduct toxicological studies and risk assessment work.

54 ENVIRONMENTAL SCIENCES↗

Canadian House Dust Study: Lead Bioaccessibility and Speciation

Vacuum samples were collected from 1025 randomly selected urban Canadian homes to investigate bioaccessible Pb (Pb{sub S}) concentrations in settled house dust. Results indicate a polymodal frequency distribution, consisting of three lognormally distributed subpopulations defined as 'urban background' (geomean 58 {micro}g g{sup -1}), 'elevated' (geomean 447 {micro}g g{sup -1}), and 'anomalous' (geomean 1730 {micro}g g{sup -1}). Dust Pb{sub S} concentrations in 924 homes (90%) fall into the 'urban background' category. The elevated and anomalous subpopulations predominantly consist of older homes located in central core areas of cities. The influence of house age is evidenced by a moderate correlation between house age and dust Pb{sub S} content (R{sup 2} = 0.34; n = 1025; p < 0.01), but it is notable that more than 10% of homes in the elevated/anomalous category were built after 1980. Conversely, the benefit of home remediation is evidenced by the large number of homes (33%) in the background category that were built before 1960. The dominant dust Pb species determined using X-ray Absorption Spectroscopy were as follows: Pb carbonate, Pb hydroxyl carbonate, Pb sulfate, Pb chromate, Pb oxide, Pb citrate, Pb metal, Pb adsorbed to Fe- and Al-oxyhydroxides, and Pb adsorbed to humate. Pb bioaccessibility estimated from solid phase speciation predicts Pb bioaccessibility measured using a simulated gastric extraction (R{sup 2} = 0.85; n = 12; p < 0.0001). The trend toward increased Pb bioaccessibility in the elevated and anomalous subpopulations (75% {+-} 18% and 81% {+-} 8%, respectively) compared to background (63% {+-} 18%) is explained by the higher proportion of bioaccessible compounds used as pigments in older paints (Pb carbonate and Pb hydroxyl carbonate). This population-based study provides a nationally representative urban baseline for applications in human health risk assessment and risk management.

54 ENVIRONMENTAL SCIENCES↗

Application of Synchrotron Microprobe Methods to Solid-Phase Speciation of Metals and Metalloids in House Dust

Determination of the source and form of metals in house dust is important to those working to understand human and particularly childhood exposure to metals in residential environments. We report the development of a synchrotron microprobe technique for characterization of multiple metal hosts in house dust. We have applied X-ray fluorescence for chemical characterization and X-ray diffraction for crystal structure identification using microfocused synchrotron X-rays at a less than 10 {micro}m spot size. The technique has been evaluated by application to archived house dust samples containing elevated concentrations of Pb, Zn, and Ba in bedroom dust, and Pb and As in living room dust. The technique was also applied to a sample of soil from the corresponding garden to identify linkages between indoor and outdoor sources of metals. Paint pigments including white lead (hydrocerussite) and lithopone (wurtzite and barite) are the primary source of Pb, Zn, and Ba in bedroom dust, probably related to renovation activity in the home at the time of sampling. The much lower Pb content in the living room dust shows a relationship to the exterior soil and no specific evidence of Pb and Zn from the bedroom paint pigments. The technique was also successful at confirming the presence of chromated copper arsenate treated wood as a source of As in the living room dust. The results of the study have confirmed the utility of this approach in identifying specific metal forms within the dust.

09 BIOMASS FUELS↗

SU-F-T-518: Development and Characterization of a Gated Treatment System Implemented with An In-House Optical Tracking System and the Elekta Response Interface

Purpose: To report the development and characterization of the first in-house gating system implemented with an optical tracking system (OTS) and the Elekta Response™ interface. Methods: The Response™ connects a patient tracking system with a linac, enabling the tracking system to control radiation delivery. The developed system uses an in-house OTS to monitor patient breathing. The OTS consists of two infrared-based cameras, tracking markers affixed on patient. It achieves gated or breath-held (BH) treatment by calling beam ON/OFF functions in the Response™ dynamic-link library (DLL). A 4D motion phantom was used to evaluate its dosimetric and time delay characteristics. Two FF- and two FFF-IMRT beams were delivered in non-gated, BH and gated mode. The sinusoidal gating signal had a 6 sec period and 15 mm amplitude. The duty cycle included 10%, 20%, 30% and 50%. The BH signal was adapted from the sinusoidal wave by inserting 15 sec BHs. Each delivery was measured with a 2D diode array (MapCHECK™) and compared with the non-gated delivery using gamma analysis (3%). The beam ON/OFF time was captured using the service graphing utility of the linac. Results: The gated treatments were successfully delivered except the 10% duty cycle. The BH delivery had perfect agreement (100%) with non-gated delivery; the agreement of gated delivery decreased from 99% to 88% as duty cycle reduced from 50% to 20%. The beam on/off delay was on average 0.25/0.06 sec. The delivery time for the 50%, 30% and 20% duty cycle increased by 29%, 71% and 139%, respectively. No dosimetric or time delay difference was noticed between FF- and FFF-IMRT beams. Conclusion: The in-house gating system was successfully developed with dosimetric and time delay characteristics in line with published results for commercial systems. It will be an important platform for further research and clinical development of gated treatment.

43 PARTICLE ACCELERATORS↗

Comparing extracting and recirculating residential kitchen range hoods for the use in high energy efficient housing

Residential cooking can be a significant indoor source of odour, pollutants and particulate matter. Conventionally, range hoods expel the air into the ambient. A number of studies have investigated their contaminant capture performance. However, for highly energy efficient houses the installation of extracting range hoods can pose certain challenges, e.g. high ventilation losses, additional thermal bridges and potential air leakage sites. Therefore, the use of recirculation range hoods has become standard for highly energy efficient housing with mechanical ventilation with heat recovery in Central Europe. Open questions remain regarding their capture and filtration efficiency as a function of filter age, especially for particles and odours. But also, the actual energy savings potential when using recirculating instead of extracting devices in a highly energy efficient housing had not been documented yet. This paper addresses these questions with a literature review and an energetic comparison. The review identified a good number of studies which have investigated the capture performance of extracting range hoods with a focus on pollutants resulting from gas combustion and/or the cooking generated particles. These studies show that capture efficiency, in particular for front burner use, can vary drastically for different designs and that particle capture does not necessarily match capture efficiency for gaseous contaminants. No scientific study investigating the performance of recirculating range hoods was found. Tests for consumer magazines as well as surveys indicate notably lower performance compared to extracting hoods. In summary one can say that performance tests are urgently needed to quantify the capture and filter efficiency for particles and (odorous) organic compounds as a function of filter age.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peoria Housing Authority(PHA) Weatherization Training Project

The DOE Weatherization Training Project's goal is to obtain a solid foundation of administrative and technical knowledge so the Peoria Housing Authority (PHA) can establish and implement a successful Weatherization Program by 2011. The DOE weatherization Training Project's two objectives are to (1) build PHA's capabilities by (2) developing its staff members capacities via the acquisition of weatherization skills and competencies. The impacts from this project include: (a) the improvement and expansion of PHA staff skills, (b) the overall enhancement of the quality of the PHA workforce, which will (c) foster employment, (d) the ability to properly weatherize PHA housing stock, tribal buildings, and tribal members houses, which will (e) result in reduced energy use, and (f) improved tribal and household economies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commissioning of the Fresno, California, Retrofit Unoccupied Test House

Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House -- A Cold Climate Challenge Home

Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut (Fact Sheet)

By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet)

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. The City of Wyandotte, Michigan, started a construction program in 2010 to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal of the program was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a U.S. Department of Energy Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ?6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chicagoland Single-Family Housing Characterization

In this report, the PARR team identifies housing characteristics and energy use for fifteen housing types in the Chicagoland (Cook County, Illinois) region and specifies measure packages that provide an optimum level of energy savings based on a BEopt analysis. The analysis is based on assessor data and actual energy consumption data on 432,605 houses representing approximately 30% of the population.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commissioning of the Fresno, California, Retrofit Unoccupied Test House

Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Performance House—A Cold Climate Challenge Home

Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft 2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the "Performance House" were not cutting-edge, but simply "best practices practiced". The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations, Inc.: Partnering To Build Net-Zero Energy Houses in Massachusetts

Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ("Devens"), The Homes at Easthampton Meadow ("Easthampton") and Phase II of the Coppersmith Way Development ("Townsend"). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductless air source heat pump systems ("mini-splits"); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Monitoring Results for Advanced New Construction Test House—Roseville, California

A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft 2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Housing Rehabilitation Process Improvements

Rea Ventures Group, LLC, (Rea Ventures) partnered with Southface Energy Institute (Southface) on the rehabilitation of 418 low-income rental multifamily apartments located at 14 different properties in Georgia (Climate Zones 2-4). These 22-year old, individually-metered units were arranged in rowhouse or townhouse style units. Rehabilitation plans were developed using a process prescribed by the US Department of Agriculture (USDA) Rural Development program, who partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide. In 2012, over $100 million was allocated in grants and loans. Due to the unique financing mechanism as well as long-term ownership requirements, property owners are especially motivated to invest in upgrades that will increase durability and tenant retention. These buildings represent a large stock of rural affordable housing that have the potential for significant energy and cost savings for property owners and tenants. Southface analyzed the energy upgrade potential of one stereotypical property in the Rea Ventures portfolio. This study will provide insight into the most cost-effective, implementable energy efficiency and durability upgrades for this age multifamily housing, having an enormous impact not only on the portfolio of Rea Ventures but on the vast USDA and larger Federal portfolio. Additionally, Southface will identify gaps in the current capital needs assessment process, examine available audit and simulation tools and protocols, and evaluate additional auditor training or certification needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ('Devens'), The Homes at Easthampton Meadow ('Easthampton') andPhase II of the Coppersmith Way Development ('Townsend'). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductlessair source heat pump systems ('mini-splits'); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unlocking Solar for Low- and Moderate-Income Residents: A Matrix of Financing Options by Resident, Provider, and Housing Type

Historically the low and moderate income (LMI) market has been underserved by solar photovoltaics (PV), in part due to the unique barriers LMI residents face to participation in the PV market. The intent of this report is to identify the most promising strategies state policymakers might consider to finance PV for LMI customers across three housing types: single family, multi-family, and manufactured housing. The result is a financing matrix that documents the first and second tier financing options states may consider for each housing type. The first tier options were selected based upon their potential impact on LMI PV deployment. Second tier financing approaches could also be used to achieve state policy goals, but may not have as much effect on the relevant LMI market segment. Nevertheless, each financing option comes with tradeoffs that state policymakers may wish to consider when they make decisions about which financing approaches are best suited to achieve their LMI PV deployment goals.

14 SOLAR ENERGY↗