Carbon Dioxide Observational Platform System (CO-OPS), feasibility study

The Carbon Dioxide Observational Platform System (CO-OPS) is a near-space, geostationary, multi-user, unmanned microwave powered monitoring platform system. This systems engineering feasibility study addressed identified existing requirements such as: carbon dioxide observational data requirements, communications requirements, and eye-in-the-sky requirements of other groups like the Defense Department, the Forestry Service, and the Coast Guard. In addition, potential applications in: earth system science, space system sciences, and test and verification (satellite sensors and data management techniques) were considered. The eleven month effort is summarized. Past work and methods of gathering the required observational data were assessed and rough-order-of magnitude cost estimates have shown the CO-OPS system to be most cost effective (less than $30 million within a 10 year lifetime). It was also concluded that there are no technical, schedule, or obstacles that would prevent achieving the objectives of the total 5-year CO-OPS program.

Bouquet, D. L.↗

Minimum weight design of rotorcraft blades with multiple frequency and stress constraints

Minimum weight designs of helicopter rotor blades with constraints on multiple coupled flap-lag natural frequencies are studied. Constraints are imposed on the minimum value of the blade autorotational inertia to ensure sufficient rotary inertia to autorotate in case of engine failure and on stresses to guard against structural failure due to blade centrifugal forces. Design variables include blade taper ratio, dimensions of the box beam located inside the airfoil and magnitudes of nonstructural weights. The program CAMRAD is used for the blade modal analysis; the program CONMIN is used for the optimization. A linear approximation involving Taylor series expansion is used to reduce the analysis effort. The procedure contains a sensitivity analysis consisting of analytical derivatives for objective function and constraints on autorotational inertia and stresses. Central finite difference derivatives are used for frequency constraints. Optimal designs are obtained for both rectangular and tapered blades. Using this method, it is possible to design a rotor blade with reduced weight, when compared to a baseline blade, while satisfying all the imposed design requirements.

Chattopadhyay, Aditi↗

Method of evaporation

Liquids, such as juices, milk, molten metal and the like are concentrated by forming uniformly-sized, small droplets in a precision droplet forming assembly and deploying the droplets in free fall downwardly as a central column within an evacuated column with cool walls. A portion of the solvent evaporates. The vapor flows to the wall, condenses, and usually flows down the wall as a film to condensate collector and drain. The vertical column of freely falling droplets enters the splash guard. The condensate can be collected, sent to other towers or recycled.

Dufresne, Eugene R.↗

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

Single-event upset (SEU) in a DRAM with on-chip error correction

Results are given of SEU measurements on 256K dynamic RAMs with on-chip error correction. They are claimed to be the first ever reported. A (12/8) Hamming error-correcting code was incorporated in the layout. Physical separation of the bits in each code word was used to guard against multiple bits being disrupted in any given word. Significant reduction in observed errors is reported.

Zoutendyk, J. A.↗

An integrated approach to the synthesis of geometrically non-linear structures

An integrated approach to the minimum weight design of geometrically nonlinear three-dimensional truss structures with geometric imperfections, subject to inequality constraints on static displacements, stresses, local buckling and cross sectional areas, is investigated. The integrated structural synthesis problem involves design and response quantities as independent variables and equilibrium equations, describing the finite element model, as equality constraints. The nonlinear structural analysis and the optimization are thus merged together into a single process. A computer program developed to compute the constraint values and analytical gradients is coupled with a generalized reduced gradient algorithm to solve the integrated problem. Numerical results for a geometrically nonlinear shallow dome example problem are presented for various types of imperfections. Furthermore, it is found that the algorithm is capable of detecting and guarding against system as well as element elastic instability using equilibrium information only, that is, without imposing system and local buckling inequality constraints.

Smaoui, H.↗

Utilization of spray on foam insulation for manned and unmanned spacecraft and structures

The idea of using spray-on foam insulation as a passive thermal and micrometeorite protection system is explored. The benefits of applying an exterior coating of foam insulation can be: (1) the foam can provide a thermally stable shield that can assist in reducing the strain on traditional space radiator systems and can also act as a passive thermal guard, allowing a greater fault tolerance if the standard system should fail; (2) the foam can act as an ablative shell diminishing the effects of natural and manmade debris striking the structure; (3) the foam is lightweight - about 1/2 ounce per sq ft; (4) the foam is low cost and easy to maintain; and (5) the foam is a stable material that does not react when exposed to earth or lunar environments.

Hancock, Thomas M., III↗

The Instrument Test Dewar (ITD): Testing satellite instruments at 1.5 K

The Instrument Test Dewar (ITD) is a cryogenic facility designed and built to test Cosmic Background Explorer (COBE) satellite instruments at 1.5 K. The facility provides a high vacuum and thermal environment with payload thermal, electrical and optical interfaces. There are two concentric vacuum spaces which are not hermitically sealed. The instrument vacuum space is 81.28 cm by 243.84 cm and is cooled by an LHe shroud. The guard vacuum space surrounds an LN2 shroud. There are two separate cryosorption pumping systems and a mechanical LHe pumping system. The data acquisition systems provide payload and housekeeping data. There have been various problems with the facility, and changes and improvements have been made to assure optimum test conditions. COBE instrument testing has been completed on structural, thermal model hardware and the protoflight units.

Milam, Laura J.↗

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

Theft of information in the take-grant protection model

Questions of information flow are in many ways more important than questions of access control, because the goal of many security policies is to thwart the unauthorized release of information, not merely the illicit obtaining of access rights to that information. The Take-Grant Protection Model is a theoretical tool for examining such issues because conditions necessary and sufficient for information to flow between two objects, and for rights to objects to be obtained or stolen, are known. These results are extended by examining the question of information flow from an object the owner of which is unwilling to release that information. Necessary and sufficient conditions for such theft of information to occur are derived, and bounds on the number of subjects that must take action for the theft to occur are presented. To emphasize the usefulness of these results, the security policies of complete isolation, transfer of rights with the cooperation of an owner, and transfer of information (but not rights) with the cooperation of the owner are presented; the last is used to model a simple reference monitor guarding a resource.

Bishop, Matt↗

Si/IrSi3 Schottky-Barrier Infrared Detectors

Si/IrSi or Si/IrSi3 Schottky-barrier detector fabricated by stoichiometric codeposition of Ir and Si on p Si substrate. Includes p+ substrate contact, silicide electrode, and n Si guard ring, which suppresses leakage around periphery of silicide electrode. Part of continuing effort to develop imaging arrays of Schottky-barrier detectors operating at far-infrared wavelengths.

Lin, True-Lon↗

VIPER project

The VIPER project has so far produced a formal specification of a 32 bit RISC microprocessor, an implementation of that chip in radiation-hard SOS technology, a partial proof of correctness of the implementation which is still being extended, and a large body of supporting software. The time has now come to consider what has been achieved and what directions should be pursued in the future. The most obvious lesson from the VIPER project was the time and effort needed to use formal methods properly. Most of the problems arose in the interfaces between different formalisms, e.g., between the (informal) English description and the HOL spec, between the block-level spec in HOL and the equivalent in ELLA needed by the low-level CAD tools. These interfaces need to be made rigorous or (better) eliminated. VIPER 1A (the latest chip) is designed to operate in pairs, to give protection against breakdowns in service as well as design faults. We have come to regard redundancy and formal design methods as complementary, the one to guard against normal component failures and the other to provide insurance against the risk of the common-cause failures which bedevil reliability predictions. Any future VIPER chips will certainly need improved performance to keep up with increasingly demanding applications. We have a prototype design (not yet specified formally) which includes 32 and 64 bit multiply, instruction pre-fetch, more efficient interface timing, and a new instruction to allow a quick response to peripheral requests. Work is under way to specify this device in MIRANDA, and then to refine the spec into a block-level design by top-down transformations. When the refinement is complete, a relatively simple proof checker should be able to demonstrate its correctness. This paper is presented in viewgraph form.

Kershaw, John↗

Rise-time response of nickel-foil-on-Kapton-substrate, hot-film, shear-stress sensors

An existing nickel-foil-on-Kapton-substrate sensor design was modified by including two heated elements in an attempt to minimize or reduce substrate conduction effects. The rise-time responses of the original and modified sensors were then investigated in unsteady flows of 0.5-1-s duration, consistent with flows encountered in wind-energy applications. The results obtained indicate a measurable degradation in transient performance due to the activation of the dynamic guard heater. Transient heat conduction within the substrate remains the limiting factor in such applications.

Reda, Daniel C.↗

Linear arrays of InGaAs/InP avalanche photodiodes for 1.0-1.7 micron

Separate absorption and multiplication InGaAs/InP avalanche photodiodes (SAM-APDs) with a floating guard ring structure that is well-suited to array applications have been successfully demonstrated. Individual APDs have breakdown voltages greater than 80 V, multiplications over 40 at 100 nA dark current, and uniform spatial gain profiles. Uniform I-V characteristics and gains have been measured over linear dimensions as large as 1.2 cm. Gains over 10 at low multiplied dark currents were measured on 21 consecutive devices at the wafer level.

Ackley, D. E.↗

Hubble Space Telescope: Faint object spectrograph instrument handbook. Version 1.1

The Faint Object Spectrograph (FOS) has undergone substantial rework since the 1985 FOS Instrument Handbook was published, and we are now more knowledgeable regarding the spacecraft and instrument operations requirements and constraints. The formal system for observation specification has also evolved considerably, as the GTO programs were defined in detail. This supplement to the FOS Instrument Handbook addresses the important aspects of these changes, to facilitate proper selection and specification of FOS observing programs. Since the Handbook was published, the FOS red detector has been replaced twice, first with the best available spare in 1985 (which proved to have a poor, and steadily degrading red response), and later with a newly developed Digicon, which exhibits a high, stable efficiency and a dark-count rate less than half that of its predecessors. Also, the FOS optical train was realigned in 1987-88 to eliminate considerable beam-vignetting losses, and the collimators were both removed and recoated for greater reflectivity. Following the optics and detector rework, the FOS was carefully recalibrated (although only ambient measurements were possible, so the far-UV characteristics could not be re-evaluated directly). The resulting efficiency curves, including improved estimates of the telescope throughput, are shown. A number of changes in the observing-mode specifications and addition of several optional parameters resulted as the Proposal Instructions were honed during the last year. Target-brightness limitations, which have only recently been formulated carefully, are described. Although these restrictions are very conservative, it is imperative that the detector safety be guarded closely, especially during the initial stages of flight operations. Restrictions on the use of the internal calibration lamps and aperture-illumination sources (TA LEDs), also resulting from detector safety considerations, are outlined. Finally, many changes have been made to the instructions for target acquisition specification.

Ford, Holland C.↗

Helium jet dispersion to atmosphere

On the event of loss of vacuum guard of superinsulated helium dewar, high rate of heat transfer into the tank occurs. The rapid boiling of liquid helium causes the burst disk to rupture at four atmospheres and consequently the helium passes to the atmosphere through vent lines. The gaseous helium forms a vertical buoyant jet as it exits the vent line into a stagnant environment. Characterization of the gaseous jet is achieved by detailed analysis of the axial and radial dependence of the flow parameters.

Khan, Hasna J.↗

GPS orbit determination at the National Geodetic Survey

The National Geodetic Survey (NGS) independently generates precise ephemerides for all available Global Positioning System (GPS) satellites. Beginning in 1991, these ephemerides were produced from double-differenced phase observations solely from the Cooperative International GPS Network (CIGNET) tracking sites. The double-difference technique combines simultaneous observations of two satellites from two ground stations effectively eliminating satellite and ground receiver clock errors, and the Selective Availability (S/A) signal degradation currently in effect. CIGNET is a global GPS tracking network whose primary purpose is to provide data for orbit production. The CIGNET data are collected daily at NGS and are available to the public. Each ephemeris covers a single week and is available within one month after the data were taken. Verification is by baseline repeatability and direct comparison with other ephemerides. Typically, an ephemeris is accurate at a few parts in 10(exp 7). This corresponds to a 10 meter error in the reported satellite positions. NGS is actively investigating methods to improve the accuracy of its orbits, the ultimate goal being one part in 10(exp 8) or better. The ephemerides are generally available to the public through the Coast Guard GPS Information Center or directly from NGS through the Geodetic Information Service. An overview of the techniques and software used in orbit generation will be given, the current status of CIGNET will be described, and a summary of the ephemeris verification results will be presented.

M. S. Schenewerk↗

LORAN-C data reduction at the US Naval Observatory

As part of its mission and in cooperation with the U.S. Coast Guard, the U.S. Naval Observatory (USNO) monitors and reports the timing of the LORAN-C chains. The procedures for monitoring and processing the reported values have evolved with advances in monitoring equipment, computer interfaces and PCs. This paper discusses the current standardized procedures used by USNO to sort the raw data according to Group Repetition Interval (GRI) rate, to fit and smooth the data points, and, for chains remotely monitored, to tie the values to the USNO Master Clock. The results of these procedures are the LORAN time of transmission values, as references to UTC(USNO) (Universal Coordinated Time) for all LORAN chains. This information is available to users via USNO publications and the USNO Automated Data Service (ADS).

Harold Chadsey↗