Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid disturbance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Calculating Critical Inertia of a Power System

The increasing integration of renewable energy sources in modern power systems has led to a decline in system inertia, raising concerns about frequency stability following large disturbances. Determining critical inertia is essential to prevent excessive frequency decline and ensure grid stability. This paper evaluates four different methods for calculating critical inertia, using the Electric Reliability Council of Texas (ERCOT) system as a test case. The results highlight the importance of employing multiple methodologies to capture the full spectrum of inertia requirements.

Hakim sneha, Fariha [University of Tennessee, Knox↗

Application of a multi-level grid method to transonic flow calculations

A multi-level grid method has been studied as a possible means of accelerating convergence in relaxation calculations for transonic flows. The method employs a hierarchy of grids, ranging from very coarse (e.g., 8 x 2 mesh cells) to fine (e.g., 128 x 32); the coarser grids are used to diminish the magnitude of the smooth part of the residuals, hopefully with far less total work than would be required with, say, optimal SLOR iterations on the finest grid. The method was applied to the solution of the transonic small-disturbance equation for the velocity potential in the conservation form. Nonlifting transonic flow past a parabolic-arc airfoil is the example studied, with meshes of both constant and variable step size.

South, J. C., Jr.↗

Numerical simulation of the effect of spatial disturbances on vortex asymmetry

The steady asymmetric vortex pattern observed on slender bodies of revolution at large angle of attack was investigated using fine-grid Navier-Stokes computations. The computed results demonstrate the marked asymmetry which has been observed in experiments. To obtain asymmetry, it was found essential to introduce a space-fixed time-invariant perturbation into the computation. The computational results suggest that vortex asymmetry is forced by amplification of small disturbances, such as those due to surface roughness, occurring within the body viscous boundary layer.

Degani, David↗

Detection of Northern Hemisphere Transient Baroclinic Eddies in REMS Pressure Data at Gale Crater Mars

Wintertime transient baroclinic eddies in the northern midlatitudes of Mars were identified in Viking Lander 2 (VL2, 48.3N, 134.0E) surface pressure data back in the early 1980s. Here we report the results of an analysis of REMS surface pressure data acquired by the Curiosity Rover in Gale Crater (4.5S, 137.4E) that suggests the meridional scale of these eddies is so large that the disturbances in the surface pressure fields they create extend across the equator and into the southern hemisphere. A power spectrum analysis of the seasonally detrended REMS pressure data from Ls=240-280 shows dominant periods of ~ 6 sols and ~2.2 sols (though with greatly reduced power) which are close the dominant periods of the transient eddies observed by VL2 at this season. Analysis of the surface pressure fields from the Ames Mars GCM for the same season also shows dominant periods at the grid points closest to VL2 and Gale Crater similar to those observed. In the model, the disturbances responsible for these oscillations are eastward traveling baroclinic eddies whose amplitudes are greatest at northern mid latitudes at this season, but whose meridional extent does indeed extend into the low latitudes of the southern hemisphere. REMS appears to be seeing the signature of these eddies, not only for this season but for the early fall and late winter seasons as well. While orbital images of the so called “flushing storms”, which more closely correspond to the shorter period waves, show dust-lifting frontal systems that cross the equator, REMS data - even though acquired at a longitude of comparatively weak storm activity - provide the first in-situ evidence that northern hemisphere transient eddies can be detected at the surface in low latitudes of the southern hemisphere.

REMS Data↗

A Kinetic Monte Carlo Approach for Simulating Cascading Transmission Line Failure

In this work, cascading transmission line failures are studied through a dynamical model of the power system operating under fixed conditions. The power grid is modeled as a stochastic dynamical system where first-principles electromechanical dynamics are excited by small Gaussian disturbances in demand and generation around a specified operating point. In this context, a single line failure is interpreted in a large deviation context as a first escape event across a surface in phase space defined by line security constraints. The resulting system of stochastic differential equations admits a transverse decomposition of the drift, which leads to considerable simplification in evaluating the quasipotential (rate function) and, consequently, computation of exit rates. Tractable expressions for the rate of transmission line failure in a restricted network are derived from large deviation theory arguments and validated against numerical simulations. Extensions to realistic settings are considered, and individual line failure models are aggregated into a Markov model of cascading failure inspired by chemical kinetics. Cascades are generated by traversing a graph composed of weighted edges representing transitions to degraded network topologies. Numerical results indicate that the Markov model can produce cascades with qualitative power-law properties similar to those observed in empirical cascades.

Kinetic Monte Carlo, rare events, Cascading Failur↗

Calculation of unsteady linearized Euler flows in cascades using harmonically deforming grids

A method for calculating unsteady, inviscid, compressible flows in cascades is presented. Using the linearized Euler technique, the flow is decomposed into a steady or mean flow plus a harmonically varying small disturbance flow. The equations that describe the small disturbance flow are linear variable coefficient equations, and are solved using a pseudo-time time marching Lax-Wendroff technique. Unlike previous linearized methods, however, the solution is computed on a harmonically deforming computational grid that conforms to the motion of the vibrating airfoils. The mean flow and perturbation flow solutions are defined in the deforming coordinate system rather than in a coordinate system fixed in space. Hence, no extrapolation terms are required to implement the upwash boundary conditions at the airfoil surfaces, significantly improving the accuracy of the method. For transonic flow calculations, unsteady shock motions are modelled using shock capturing. The unsteady loads due to the shock motion are then seen as pressure impulses. Representative computational results are presented for transonic channel flows and subsonic and transonic cascade flows.

Hall, Kenneth C.↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

A three-dimensional simulation of transition and early turbulence in a time-developing mixing layer

The physics of the transition and early turbulence regimes in the time developing mixing layer was investigated. The sensitivity of the mixing layer to the disturbance field of the initial condition is considered. The growth of the momentum thickness, the mean velocity profile, the turbulence kinetic energy, the Reynolds stresses, the anisotropy tensor, and particle track pictures of computations are all examined in an effort to better understand the physics of these regimes. The amplitude, spectrum shape, and random phases of the initial disturbance field were varied. A scheme of generating discrete orthogonal function expansions on some nonuniform grids was developed. All cases address the early or near field of the mixing layer. The most significant result shows that the secondary instability of the mixing layer is produced by spanwise variations in the straining field of the primary vortex structures.

Cain, A. B.↗

Extending a transonic small disturbance code to treat swept vertical surfaces

A flexible-swept vertical surface capability has been developed and implemented within the CAP-TSD transonic small disturbance (TSD) code. The new capability required a modification to the TSD equation and a grid transformation for swept vertical surfaces. Modifications to the vertical surface boundary conditions allow it to be treated as a flexible surface. The new capability extends the range of problems which the code can treat. In order to assess the accuracy of the modifications, calculations were performed for a rectangular T-tail configuration and an AGARD T-tail configuration. Unsteady forces and moments are presented for the rectangular T-tail oscillating in yaw for a range of reduced frequencies. Comparisons are presented with linear theory and experiment. Steady and unsteady surface pressures are presented for the AGARD T-tail along with generalized aerodynamic forces. Comparisons are made with linear theory. The comparisons demonstrate the accuracy of the vertical surface modifications.

Gibbons, Michael D.↗

Phase-averaged measurements of perturbations introduced into boundary layers

Large-scale structures in turbulent and transitional wall-bounded flows make a significant contribution to the Reynolds stress and turbulent energy. The behavior of these structures is examined. Small perturbations are introduced into a laminar and a turbulent boundary layer to trigger the formation of large-scale features. Both flows use the same inlet unit Reynolds number, and they experience the same pressure gradient history, i.e. a favorable pressure gradient (FPG) followed by an adverse pressure gradient (APG). The perturbation consists of a small short duration flow repetitively introduced through a hole in the wall located at the C(sub p) minimum. Hot-wire data are averaged on the basis of the phase of the disturbance, and automation of the experiment was used to obtain measurements on large spatially dense grids. In the turbulent boundary, the perturbation evolves into a vortex loop which retains its identity for a considerable streamwise distance. In the laminar layer, the perturbation decays to a very small magnitude before growing rapidly and triggering the transition process in the APG. The 'time-like' animations of the phase-averaged data are used to gain insight into the naturally occurring physical mechanisms in each flow.

Watmuff, Jonathan H.↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

Nonreflecting boundary conditions for the complete unsteady transonic small-disturbance equation

Nonreflecting far-field boundary conditions that are consistent with the complete transonic small-disturbance (TSD) equations are derived. They are implemented in a new code for solving the complete TSD equation and are tested for a harmonically oscillating NACA 64A010 airfoil in transonic flow and for a flat-plate airfoil with a pulse in the angle of attack. Using the new boundary conditions on a relatively small grid, solutions for the airfoil that are obtained that agree with large-grid calculations, resulting in a 44 percent savings in computer time. Frequency responses for the flat plate show that most of the disturbances incident on the computational boundaries are absorbed by the boundary conditions.

Whitlow, W., Jr.↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗

Correlation between Generator Trips and Locational Marginal Prices (LMPs)

Generally, disturbances in an interconnected network have an influence the stability and the economy of the power grid. Some phenomenon such as load shedding have proven to have a huge impact on real time electricity prices. Generation trip is considered one of the most common events in a power grid that may change the wholesale electricity market. In this paper, a locational marginal price (LMP) measure is used to notice how the electricity prices change with generator trip events at different locations of U.S. power grid. The study results help to find whether there is a clear correlation between generator trips and the changes in the electricity real-time market.

Alharbi, Abdulelah↗